Loading...
HomeMy WebLinkAboutEnergy Code2017 EPL DISPLAY CARD r n0 1. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD '060,P �o ESTIMATED ENERGY PERFORMANCE INDEX* = 94 01 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity76.7 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3641 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.277 c) Area 7c. 691.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 30.0 9c. 10A1. 10A2. 9.0 14. Heating system: Capacity 61.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other 10B1. 1062. 9.0 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. 2 Builder Signature:, 'd Date: O,2' JI-2i zO Address of New Home: 7683 PELICAN POINTE DRIVE City/FL Zip: PORT ST LUCIE. FL 1/28/2020 3:28:55 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ROAF RESIDENCE Builder Name: OAKMONT CUSTOM HOMES Street: 7683 PELICAN POINTE DRIVE Permit Office: ST LUCIE COUNTY City, Slate, Zip: PORT ST LUCIE, FL, Permit Number: Owner: WILLIAM AND ANGELA ROAF Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or epsting New (From Plans) 9. Wall Types (4165.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Polystyrene Bead Aggre2=9.0 3882.80 ft2 b. Concrete Block- Polystyrene Bead Aggrgy=9,0 282.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (3641.0 sgft.) Insulation Area 5. Is this a worst case?- No a. Under Attic (Vented) R=30.0 3641.00 112 6. Conditioned floor area above grade (ft2) 3641 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 G. N/A 11. Ducts R= ft2 R f12 7. Windows (691.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 150 a. U-Factor: Sill, U=0.65 366.67 ft2 b. Sup: Attic, Ret: Attic, AH: Garage 6 125 SHGC: SHGC=0.30 c. Sup: Attic, Ret: Attic, AH: Attic 6 140 b. U-Factor: Bill, U=0.65 324.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 35.2 SEER:16.00 b. Central Unit 17.7 SEER:16.00 c. U-Factor: N/A ft2 c. Central Unit 23.8 SEER:16.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. NIA ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 7.646 ft. c. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC: 0.277 14. Hot water systems a. Electric Cap: 85 gallons 8. Floor Types (3641.0 sgft.) Insulation Area EF: 0.980 a. Raised Floor R=30.0 3594.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 47.00 ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.190 Total Proposed Modified Loads: 123.88 PASS Total Baseline Loads: 132.01 I hereby certify that the plans and specifications covered by Review of the plans and ES this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: sz Before construction is completed DATE: 1-28-20 this building will be inspected for compliance with Section 553.908 1 yd I hereby certify that this building, as designedliance Florida Statutes. with the Florida Energy Code. i, �- `y OWNER/AGENT BUILDING OFFICIAL: DATE: �/��� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2). 1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ROAF RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3641 Lot # Owner Name: WILLIAM AND ANGELA RDA Total Stories: 1 Block/Subdivlsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: OAKMONT CUSTOM HOME Rotate Angle: 0 Street: 7683 PELICAN POINTE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.6 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1743 17604.3 2 AHU 2 737 7443.7 3 AHU 3 1161 11475 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 M TOILET 41 414.1 No 0 1 No Yes Yes 2 M HALL 20 202 No 0 1 No Yes Yes 3 M WIC 2 56 565.6 No 0 1 No Yes Yes 4 M W IC 1 52 525.2 No 0 1 Yes Yes Yes 5 MASTER BEDROO 322 3252.2 No 0 1 1 Yes Yes Yes 6 M CLST 24 242.4 No 0 1 Yes Yes Yes 7 M BATH 222 2242.2 No 0 1 Yes Yes Yes 8 CLUB HALL 52 499.2 No 0 1 Yes Yes Yes 9 BEDROOM 3 198 1900.8 No 0 1 1 Yes Yes Yes 10 LINEN CLST 10 96 No 0 1 No Yes Yes 11 WIC 3 30 288 No 0 1 Yes Yes Yes 12 BATH 3 68 652.8 No 0 1 Yes Yes Yes 13 CLUB ROOM 549 5599.8 No 0 1 Yes Yes Yes 14 STAIRS UP 205 1968 No 0 1 Yes Yes Yes 15 ELEV. 3RD FLR 49 470.4 No 0 1 No Yes Yes 16 LIVINGIDINING 548 5534.8 No 0 1 Yes Yes Yes 17 GARAGE ELEV. 47 474.7 No 0 1 No Yes Yes 18 ELEV.2ND 49 494.9 No 0 1 No Yes Yes 19 UTILITY 108 1090.8 No 0 1 Yes Yes Yes 20 STORAGEWIC 50 505 No 0 1 Yes Yes Yes 1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 21 FOYER 72 727.2 No 0 1 Yes Yes Yes 22 PANTRY 128 1292.8 No 0 1 Yes Yes Yes 23 A/C CHASE 32 323.2 No 0 1 Yes Yes Yes 24 KITCHEN 369 3726.9 Yes 0 1 No Yes Yes 25 BEDROOM 2 162 1636.2 No 0 1 1 Yes Yes Yes 26 HALL 30 303 No 0 1 Yes Yes Yes 27 WIC 24 242.4 No 0 1 No Yes Yes 28 BATH 2 66 666.6 No 0 1 Yes Yes Yes 29 POWDER RM 58 585.8 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Raised Floor M TOILET -_ ____ 41 ft' 30 1 0 0 2 Raised Floor M HALL ___ ____ 20 ft2 30 1 0 0 3 Raised Floor M W IC 2 — _--- 56 ft' 30 1 0 0 4 Raised Floor M WIC 1 — ---- 52 ft2 30 1 0 0 5 Raised Floor MASTER BEDRO ____ ____ 322 ft2 30 1 0 0 6 Raised Floor M CLST ____ ___ 24 ft2 30 1 0 0 7 Raised Floor M BATH ____ — 222 ft2 30 1 0 0 8 Raised Floor CLUB HALL ____ ____ 52 ft' 30 1 0 0 9 Raised Floor BEDROOM 3 ____ ____ 198 ft2 30 1 0 0 10Raised Floor LINEN CLST ___ ____ 10 ft2 30 1 0 0 11Raised Floor WIC 3 ___ _--_ 30 ft2 30 1 0 0 12Raised Floor BATH 3 ____ ____ 68 f12 30 1 0 0 13Raised Floor CLUB ROOM ____ ___ 549 ft2 30 1 0 0 14Raised Floor STAIRS UP ____ ____ 205 ft2 30 1 0 0 16Raised Floor ELEV. 3RD FLR ---- ____ 49 ft2 30 1 0 0 16Raised Floor LIVING/DINING ____ ____ 548 ft2 30 1 0 0 17Slab-On-Grade Edge Insulation GARAGE ELEV. 1 ft 0 47 ft2 -___ 1 0 0 18Raised Floor ELEV. 2ND ____ __-_ 49 ft2 30 1 0 0 1 gRaised Floor UTILITY ____ ____ 108 ft2 30 1 0 0 2013aised Floor STORAGE WIC ____ ____ 50 ft2 30 1 0 0 1128f2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 21Raised Floor FOYER ___ — 72 ft2 30 1 0 0 22Raised Floor PANTRY -___ ____ 128 ft2 30 1 0 0 23Raised Floor A/C CHASE ____ -___ 32 ft2 30 1 0 0 24Raised Floor KITCHEN ____ ____ 369 ft2 30 1 0 0 25Raised Floor BEDROOM 2 ____ ___ 162 ft2 30 1 0 0 26Raised Floor HALL 2 ____ ____ 30 ft2 30 1 0 0 27Raised Floor WIC 2 ____ ____ 24 ft2 30 1 0 0 28Raised Floor BATH 2 -___ ---_ 66 ft2 30 1 0 0 29Raised Floor POWDERRM ____ _--_ 58 ft2 30 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat file/slate 3837 ft2 0 ft2 Medium N 0.3 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 3641 ft2 N N 1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MTOILET 30 Blown 41 ft2 0.1 Wood 2 Under Attic (Vented) MHALL 30 Blown 20 IF 0.1 Wood 3 Under Attic (Vented) M W IC 2 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M WIC 1 30 Blown 52 ft' 0.1 Wood 5 Under Attic (Vented) MASTER BEDRO 30 Blown 322It' 0.1 Wood _ 6 Under Attic (Vented) M CLST 30 Blown 24 ft' 0.1 Wood 7 Under Attic (Vented) M BATH 30 Blown 222 ft' 0.1 Wood _ 8 Under Attic (Vented) CLUB HALL 30 Blown 52 ft' 0.1 Wood 9 Under Attic (Vented) BEDROOM 30 Blown 198 It, 0.1 Wood 10 Under Attic (Vented) LINEN CLST 30 Blown 10 ft2 0.1 Wood _ 11 Under Attic (Vented) WIC 30 Blown 30 It' 0.1 Wood _ 12 Under Attic (Vented) BATH 3 30 Blown 68 ft2 0.1 Wood _ 13 Under Attic (Vented) CLUB ROOM 30 Blown 549 ft2 0.1 Wood _ 14 Under Attic (Vented) STAIRS UP 30 Blown 205 ft2 0.1 Wood 15 Under Attic (Vented) ELEV. 3RD FUZZ 30 Blown 49 ft2 0.1 Wood _ 16 Under Attic (Vented) LIVING/DINING 30 Blown 548 ft2 0.1 Wood _ 17 Under Attic (Vented) GARAGE ELEV. 30 Blown 47 ft2 0.1 Wood _ 18 Under Attic (Vented) ELEV. 2ND 30 Blown 49 ft2 0.1 Wood 19 Under Attic (Vented) UTILITY 30 Blown 108 ft2 0.1 Wood _ 20 Under Attic (Vented) STORAGEWIC 30 Blown 50 ft2 0.1 Wood _ 21 Under Attic (Vented) FOYER 30 Blown 72 ft' 0.1 Wood 22 Under Attic (Vented) PANTRY 30 Blown 128 ft' 0.1 Wood _ 23 Under Attic (Vented) A/C CHASE 30 Blown 32 ft2 0.1 Wood _ 24 Under Attic (Vented) KITCHEN 30 Blown 369 ft' 0.1 Wood 25 Under Attic (Vented) BEDROOM 2 30 Blown 162 ft2 0.1 Wood _ 26 Under Attic (Vented) HALL 30 Blown 30 ft2 0.1 Wood _ 27 Under Attic (Vented) WIC 30 Blown 24 ft2 0.1 Wood 28 Under Attic (Vented) BATH 2 30 Blown 66 ft2 0.1 Wood 29 Under Attic (Vented) POWDER RM 30 Blown 58 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block - PolystyrerM WIC 1 9 13 0 10 1 131.1 ft2 0 0 0.3 0 _ 2 E Exterior Concrete Block - Polysty#dkSTER BE 9 17 0 10 1 171.4 ft' 0 0 0.3 0 _ 3 S Exterior Concrete Block - PolystyMOESTER BE 9 15 0 10 1 151.3 ft2 0 0 0.3 0 4 W Exterior Concrete Block - PolyslydAISTER BE 9 10 0 10 1 100.8 ft2 0 0 0.3 0 _ 5 E Exterior Concrete Block - Polystyrerfd CLST 9 6 0 10 1 60.5 It, 0 0 0.3 0 6 N Exterior Concrete Block - Polystyrerld BATH 9 16 0 10 1 161.3 ft' 0 0 0.3 0 _ 7 E Exterior Concrete Block - PolystyrerM BATH 9 15 0 10 1 151.3 ft2 0 0 0.3 0 _ 8 BE Exterior Concrete Block- Polystyr&WB HALL 9 4 3 9 7 40.7 IF 0 0 0.3 0 _ 9 E Exterior Concrete Block - PolystyBEDROOM 3 9 9 0 9 7 86.3 ft' 0 0 0.3 0 _ 10 S Exterior Concrete Block - PolystyREDR00M 3 9 15 0 9 7 143.8 ft' 0 0 0.3 0 11 W Exterior Concrete Block - PolysWDROOM 3 9 15 0 9 7 143.8 ft2 0 0 0.3 0 1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 GnRne PAnr-9n17 INPl1T RUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width .Height Sheathing Framing Solar Bela w Space _ 12 W Exterior Concrete Block- Polystyren&NIC 3 9 5 0 9 7 47.9 ft2 0 0 0.3 0 _ 13 W Exterior Concrete Black - PolyslyrenBATH 3 9 6 0 9 7 57.5 ft2 0 0 0.3 0 _ 14 N Exterior Concrete Block - Polysty@htlB ROOM 9 24 0 10 2 244.0 ft2 0 0 0.3 0 _ 15 E Exterior Concrete Block - PolystyalbWB ROOM 9 19 0 10 2 193.2 ft2 0 0 0.3 0 _ 16 S Exterior Concrete Block - PolystyahBB ROOM 9 23 0 10 2 233.8 ft2 0 0 0.3 0 17 N Exterior Concrete Black - Polystyr@TeAIRS UP 9 17 0 9 7 162.9 ft2 0 0 0.3 0 _ 18 E Exterior Concrete Block - Polystyr@TGAIRS UP 9 12 0 9 7 115.0 ft2 0 0 0.3 0 _ 19 W Exterior Concrete Block - Polystyr&TGAIRS UP 9 17 0 9 7 162.9 ft2 0 0 0.3 0 20 S Exterior Concrete Block - PolystytWtNG/DININ 9 23 0 10 1 231.9 ft2 0 0 0.3 0 _ 21 N Garage Concrete Block - Polystyi@ WAGE EL 9 7 0 10 1 70.6 112 0 0 0.3 0 _ 22 W Garage Concrete Block - Polystyi@06?AGE EL 9 7 0 10 1 70.6 ft2 0 0 0.3 0 _ 23 S Garage Concrete Block - Polyslyi@dr£2AGE EL 9 7 0 10 1 70.6 ft2 0 0 0.3 0 24 E Garage Concrete Block - PolyslyiGYWAGE EL 9 7 0 10 1 70.6 ft2 0 0 0.3 0 25 N Exterior Concrete Block- PolystyrerWTILITY 9 11 0 10 1 110.9 ft2 0 0 0.3 0 26 W Exterior Concrete Block - PolystyrerldTILITY 9 8 0 10 1 80.7 ft2 0 0 0.3 0 27 W Exterior Concrete Block - Polysty&Ti@RAGE W 9 8 0 10 1 80.7 ft2 0 0 0.3 0 _ 28 N Exterior Concrete Block - PolystyrenEOYER 9 9 0 10 1 90.8 ft2 0 0 0.3 0 _ 29 N Exterior Concrete Block - PolystyrerR ANTRY 9 15 0 10 1 151.3 ft2 0 0 0.3 0 _ 30 E Exterior Concrete Block - PolystyreWNTRY 9 1 0 10 1 10.1 ft2 0 0 0.3 0 31 W Exterior Concrete Block - PolystyredSANTRY 9 1 0 10 1 10.1 ft2 0 0 0.3 0 _ 32 N Exterior Concrete Block - PolyslyrEd@ CHASE 9 4 0 10 1 40.3 ft2 0 0 0.3 0 _ 33 E Exterior Concrete Block - PolystyREmROOM 2 9 7 0 10 1 70.6 ft2 0 0 0.3 0 _ 34 S Exterior Concrete Block - PolystyREmROOM 2 9 14 0 10 1 141.2 ft2 0 0 0.3 0 _ 35 W Exterior Concrete Block - PolystyMDROOM 2 9 14 0 10 1 141.2 ft2 0 0 0.3 0 _ 36 SE Exterior Concrete Block - PolystyrenNALL 2 9 4 3 10 1 42.9 ft2 0 0 0.3 0 37 W Exterior Concrete Block - PolystyrenBATH 2 9 12 0 10 1 121.0 ft2 0 0 0.3 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 E 1 Metal Low-E Single Yes 0.65 0.25 N 5.3 ft2 2 ft 0 in 1 ft 4 in None None _ 2 E 2 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 It 4 in None None 3 S 3 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 3 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None _ 5 W 4 Metal Low-E Single Yes 0.65 0.3 N 21.3 ft2 8 ft 0 in 1 ft 4 in None None _ 6 N 6 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 7 E 7 Metal Low-E Single Yes 0.65 0.25 N 5.0 ft2 2 ft 0 in 1 It 4 in None None 8 SE 8 Metal Low-E Single Yes 0.65 0.3 N 20.7 ft2 12 ft 0 in 1 ft 4 in None None _ 9 S 10 Metal Low-E Single Yes 0.65 0.25 N 45.0 ft2 2 ft 0 in 1 ft 4 in None None _ 10 W 13 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None _ 11 N 14 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None _ 12 E 15 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 It 4 in None None 13 S 16 Metal Low-E Single Yes 0.65 0.3 N 128.0 ft2 14 ft 0 in 1 ft 4 in None None 1/28/2020 3:28 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 14 N 17 Metal Low-E Single Yes 0.65 0.25 N 18.0 T 2 ft 0 in 1 ft4 in None None _ 15 W 19 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft- 2 It 0 in 1 It 4 in None None _ 16 S 20 Metal Low-E Single Yes 0.65 0.3 N 128.0 It- 14 It 0 in 1 ft 4 in None None 17 N 25 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 18 N 28 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 8 ft 0 in 1 ft 4In None None 19 N 29 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 fl0 in 1 ft 4In None None _ 20 S 34 Metal Low-E Single Yes 0.65 0.25 N 54.0 ft2 2 ft 0 in 1 ft 4 in None None 21 BE 36 Metal Low-E Single Yes 0.65 0.3 N 20.7 112 12 It 0 in 1 ft 4 in None None 22 W 37 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 It 0 in 1 ft 4 in None None 23 W 37 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2.110 in 1 It 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall insulation 1 2750 ft2 2750 ft2 28 ft a ft 9 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000446 4261 233.92 439.93 .1693 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts _ 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 _ 2 Electric Strip Heat/ None C0P:1 17 kBtu/hr 2 sys#2 3 Electric Strip Heat/ None COPA 17 kBtu/hr 3 sys#3 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 35.2 kBtu/hr 1056 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 17.7 kBtu/hr 531 cfm 0.8 2 sys#2 3 Central Unit/ Split Single SEER: 16 23.8 kBtu/hr 714 cfm 0.8 3 sys#3 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 85 gal 67.4 gal 120 deg None 1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 7 of 8 rnDnn Dnnr-,)n17 INN IT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply-- -- Return ---- Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heal Cool _ 1 Attic 6 150 ft2 Attic 15 ft' Default Leakage Garage (Default) c(Default) c 1 1 _ 2 Attic 6 125 ft2 Attic 13 1112 Default Leakage Garage (Default) c(Default) c 2 2 _ 3 Attic 6 140 ft2 Attic 14 ft2 Default Leakage All (Default) c(Default) c 3 3 TEMPERATURES Programable[Thermostat: Ceiling Fans:Cool f Heating r Jan pCl 111N [x� Feb Mar May Jun[X11 i Jun r 1 Jul j ] ri Aug [ 1 j[Xj� [xl Sep Oct Dec [[Xj] Venting [ 1 Jan [r Feb IXl Mar l l Apr ] May l Jun r I Jul r 1 Aug [ 1 Sep [XJ Nov [ J Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. 112 ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft2 ft 0.3 FOYERIGREAT RO 1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8