HomeMy WebLinkAboutEnergy Code2017 EPL DISPLAY CARD
r
n0
1.
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD '060,P �o
ESTIMATED ENERGY PERFORMANCE INDEX* = 94 01
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location varies
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity76.7
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 3641 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.650
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.277
c) Area 7c. 691.0
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b. 30.0
9c.
10A1.
10A2. 9.0
14. Heating system: Capacity 61.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
0 Other
15. Water heating system
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
0 Heat recovery unit HeatRec%
g) Other
10B1.
1062. 9.0
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
2 Builder Signature:, 'd Date: O,2' JI-2i zO
Address of New Home: 7683 PELICAN POINTE DRIVE City/FL Zip: PORT ST LUCIE. FL
1/28/2020 3:28:55 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
- FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ROAF RESIDENCE
Builder Name: OAKMONT CUSTOM HOMES
Street: 7683 PELICAN POINTE DRIVE
Permit Office: ST LUCIE COUNTY
City, Slate, Zip: PORT ST LUCIE, FL,
Permit Number:
Owner: WILLIAM AND ANGELA ROAF
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or epsting New (From Plans)
9. Wall Types (4165.2 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Polystyrene Bead Aggre2=9.0 3882.80 ft2
b. Concrete Block- Polystyrene Bead Aggrgy=9,0 282.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (3641.0 sgft.)
Insulation Area
5. Is this a worst case?- No
a. Under Attic (Vented)
R=30.0 3641.00 112
6. Conditioned floor area above grade (ft2) 3641
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
G. N/A
11. Ducts
R= ft2
R f12
7. Windows (691.0 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 150
a. U-Factor: Sill, U=0.65 366.67 ft2
b. Sup: Attic, Ret: Attic, AH: Garage
6 125
SHGC: SHGC=0.30
c. Sup: Attic, Ret: Attic, AH: Attic
6 140
b. U-Factor: Bill, U=0.65 324.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
35.2 SEER:16.00
b. Central Unit
17.7 SEER:16.00
c. U-Factor: N/A ft2
c. Central Unit
23.8 SEER:16.00
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. NIA ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 7.646 ft.
c. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average SHGC: 0.277
14. Hot water systems
a. Electric
Cap: 85 gallons
8. Floor Types (3641.0 sgft.) Insulation Area
EF: 0.980
a. Raised Floor R=30.0 3594.00 ft2
b. Conservation features
b. Slab -On -Grade Edge Insulation R=0.0 47.00 ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.190 Total Proposed Modified Loads: 123.88
PASS
Total Baseline Loads: 132.01
I hereby certify that the plans and specifications covered by
Review of the plans and
ES
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: sz
Before construction is completed
DATE: 1-28-20
this building will be inspected for
compliance with Section 553.908
1 yd
I hereby certify that this building, as designedliance
Florida Statutes.
with the Florida Energy Code.
i, �- `y
OWNER/AGENT
BUILDING OFFICIAL:
DATE: �/���
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2).
1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
ROAF RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
3641
Lot #
Owner Name:
WILLIAM AND ANGELA RDA
Total Stories:
1
Block/Subdivlsion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
OAKMONT CUSTOM
HOME
Rotate Angle:
0
Street:
7683 PELICAN
POINTE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Single-family
FL,
New/Ebsting:
New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp
Heating
Design
Daily Temp
Design Location
TMY Site
97.6 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1743
17604.3
2
AHU 2
737
7443.7
3
AHU 3
1161
11475
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
M TOILET
41
414.1
No
0
1
No
Yes
Yes
2
M HALL
20
202
No
0
1
No
Yes
Yes
3
M WIC 2
56
565.6
No
0
1
No
Yes
Yes
4
M W IC 1
52
525.2
No
0
1
Yes
Yes
Yes
5
MASTER BEDROO
322
3252.2
No
0
1
1
Yes
Yes
Yes
6
M CLST
24
242.4
No
0
1
Yes
Yes
Yes
7
M BATH
222
2242.2
No
0
1
Yes
Yes
Yes
8
CLUB HALL
52
499.2
No
0
1
Yes
Yes
Yes
9
BEDROOM 3
198
1900.8
No
0
1
1
Yes
Yes
Yes
10
LINEN CLST
10
96
No
0
1
No
Yes
Yes
11
WIC 3
30
288
No
0
1
Yes
Yes
Yes
12
BATH 3
68
652.8
No
0
1
Yes
Yes
Yes
13
CLUB ROOM
549
5599.8
No
0
1
Yes
Yes
Yes
14
STAIRS UP
205
1968
No
0
1
Yes
Yes
Yes
15
ELEV. 3RD FLR
49
470.4
No
0
1
No
Yes
Yes
16
LIVINGIDINING
548
5534.8
No
0
1
Yes
Yes
Yes
17
GARAGE ELEV.
47
474.7
No
0
1
No
Yes
Yes
18
ELEV.2ND
49
494.9
No
0
1
No
Yes
Yes
19
UTILITY
108
1090.8
No
0
1
Yes
Yes
Yes
20
STORAGEWIC
50
505
No
0
1
Yes
Yes
Yes
1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number
Name
Area Volume
Kitchen Occupants
Bedrooms
Infil ID
Finished
Cooled
Heated
21
FOYER
72 727.2
No
0
1
Yes
Yes
Yes
22
PANTRY
128 1292.8
No
0
1
Yes
Yes
Yes
23
A/C CHASE
32 323.2
No
0
1
Yes
Yes
Yes
24
KITCHEN
369 3726.9
Yes
0
1
No
Yes
Yes
25
BEDROOM 2
162 1636.2
No
0
1
1
Yes
Yes
Yes
26
HALL
30 303
No
0
1
Yes
Yes
Yes
27
WIC
24 242.4
No
0
1
No
Yes
Yes
28
BATH 2
66 666.6
No
0
1
Yes
Yes
Yes
29
POWDER RM
58 585.8
No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpel
1 Raised Floor
M TOILET
-_ ____
41 ft'
30
1
0
0
2 Raised Floor
M HALL
___ ____
20 ft2
30
1
0
0
3 Raised Floor
M W IC 2
— _---
56 ft'
30
1
0
0
4 Raised Floor
M WIC 1
— ----
52 ft2
30
1
0
0
5 Raised Floor
MASTER BEDRO
____ ____
322 ft2
30
1
0
0
6 Raised Floor
M CLST
____ ___
24 ft2
30
1
0
0
7 Raised Floor
M BATH
____ —
222 ft2
30
1
0
0
8 Raised Floor
CLUB HALL
____ ____
52 ft'
30
1
0
0
9 Raised Floor
BEDROOM 3
____ ____
198 ft2
30
1
0
0
10Raised Floor
LINEN CLST
___ ____
10 ft2
30
1
0
0
11Raised Floor
WIC 3
___ _--_
30 ft2
30
1
0
0
12Raised Floor
BATH 3
____ ____
68 f12
30
1
0
0
13Raised Floor
CLUB ROOM
____ ___
549 ft2
30
1
0
0
14Raised Floor
STAIRS UP
____ ____
205 ft2
30
1
0
0
16Raised Floor
ELEV. 3RD FLR
---- ____
49 ft2
30
1
0
0
16Raised Floor
LIVING/DINING
____ ____
548 ft2
30
1
0
0
17Slab-On-Grade Edge Insulation
GARAGE ELEV.
1 ft 0
47 ft2
-___
1
0
0
18Raised Floor
ELEV. 2ND
____ __-_
49 ft2
30
1
0
0
1 gRaised Floor
UTILITY
____ ____
108 ft2
30
1
0
0
2013aised Floor
STORAGE WIC
____ ____
50 ft2
30
1
0
0
1128f2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
21Raised Floor
FOYER
___
—
72 ft2
30
1
0
0
22Raised Floor
PANTRY
-___
____
128 ft2
30
1
0
0
23Raised Floor
A/C CHASE
____
-___
32 ft2
30
1
0
0
24Raised Floor
KITCHEN
____
____
369 ft2
30
1
0
0
25Raised Floor
BEDROOM 2
____
___
162 ft2
30
1
0
0
26Raised Floor
HALL 2
____
____
30 ft2
30
1
0
0
27Raised Floor
WIC 2
____
____
24 ft2
30
1
0
0
28Raised Floor
BATH 2
-___
---_
66 ft2
30
1
0
0
29Raised Floor
POWDERRM
____
_--_
58 ft2
30
1
0
0
ROOF
Roof
Gable Roof
Rad
Solar
SA Emitt
Emitt
Deck
Pitch
V
# Type
Materials
Area
Area Color
Barr
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Flat file/slate 3837 ft2
0 ft2 Medium
N
0.3
No 0.9
No
0
18.4
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
3641 ft2
N
N
1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) MTOILET
30
Blown
41 ft2
0.1
Wood
2
Under Attic (Vented) MHALL
30
Blown
20 IF
0.1
Wood
3
Under Attic (Vented) M W IC 2
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) M WIC 1
30
Blown
52 ft'
0.1
Wood
5
Under Attic (Vented) MASTER BEDRO
30
Blown
322It'
0.1
Wood
_
6
Under Attic (Vented) M CLST
30
Blown
24 ft'
0.1
Wood
7
Under Attic (Vented) M BATH
30
Blown
222 ft'
0.1
Wood
_
8
Under Attic (Vented) CLUB HALL
30
Blown
52 ft'
0.1
Wood
9
Under Attic (Vented) BEDROOM
30
Blown
198 It,
0.1
Wood
10
Under Attic (Vented) LINEN CLST
30
Blown
10 ft2
0.1
Wood
_
11
Under Attic (Vented) WIC
30
Blown
30 It'
0.1
Wood
_
12
Under Attic (Vented) BATH 3
30
Blown
68 ft2
0.1
Wood
_
13
Under Attic (Vented) CLUB ROOM
30
Blown
549 ft2
0.1
Wood
_
14
Under Attic (Vented) STAIRS UP
30
Blown
205 ft2
0.1
Wood
15
Under Attic (Vented) ELEV. 3RD FUZZ
30
Blown
49 ft2
0.1
Wood
_
16
Under Attic (Vented) LIVING/DINING
30
Blown
548 ft2
0.1
Wood
_
17
Under Attic (Vented) GARAGE ELEV.
30
Blown
47 ft2
0.1
Wood
_
18
Under Attic (Vented) ELEV. 2ND
30
Blown
49 ft2
0.1
Wood
19
Under Attic (Vented) UTILITY
30
Blown
108 ft2
0.1
Wood
_
20
Under Attic (Vented) STORAGEWIC
30
Blown
50 ft2
0.1
Wood
_
21
Under Attic (Vented) FOYER
30
Blown
72 ft'
0.1
Wood
22
Under Attic (Vented) PANTRY
30
Blown
128 ft'
0.1
Wood
_
23
Under Attic (Vented) A/C CHASE
30
Blown
32 ft2
0.1
Wood
_
24
Under Attic (Vented) KITCHEN
30
Blown
369 ft'
0.1
Wood
25
Under Attic (Vented) BEDROOM 2
30
Blown
162 ft2
0.1
Wood
_
26
Under Attic (Vented) HALL
30
Blown
30 ft2
0.1
Wood
_
27
Under Attic (Vented) WIC
30
Blown
24 ft2
0.1
Wood
28
Under Attic (Vented) BATH 2
30
Blown
66 ft2
0.1
Wood
29
Under Attic (Vented) POWDER RM
30
Blown
58 ft2
0.1
Wood
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing
Solar
Below
_ 1
E
Exterior Concrete Block - PolystyrerM WIC 1
9
13
0 10
1
131.1 ft2
0
0
0.3
0
_ 2
E
Exterior Concrete Block - Polysty#dkSTER BE
9
17
0 10
1
171.4 ft'
0
0
0.3
0
_ 3
S
Exterior Concrete Block - PolystyMOESTER BE
9
15
0 10
1
151.3 ft2
0
0
0.3
0
4
W
Exterior Concrete Block - PolyslydAISTER BE
9
10
0 10
1
100.8 ft2
0
0
0.3
0
_ 5
E
Exterior Concrete Block - Polystyrerfd CLST
9
6
0 10
1
60.5 It,
0
0
0.3
0
6
N
Exterior Concrete Block - Polystyrerld BATH
9
16
0 10
1
161.3 ft'
0
0
0.3
0
_ 7
E
Exterior Concrete Block - PolystyrerM BATH
9
15
0 10
1
151.3 ft2
0
0
0.3
0
_ 8
BE
Exterior Concrete Block- Polystyr&WB HALL
9
4
3 9
7
40.7 IF
0
0
0.3
0
_ 9
E
Exterior Concrete Block - PolystyBEDROOM 3
9
9
0 9
7
86.3 ft'
0
0
0.3
0
_ 10
S
Exterior Concrete Block - PolystyREDR00M 3
9
15
0 9
7
143.8 ft'
0
0
0.3
0
11
W
Exterior Concrete Block - PolysWDROOM 3
9
15
0 9
7
143.8 ft2
0
0
0.3
0
1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8
GnRne PAnr-9n17 INPl1T RUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
.Height
Sheathing
Framing
Solar
Bela w
Space
_ 12
W
Exterior
Concrete Block- Polystyren&NIC 3
9
5
0
9
7
47.9 ft2
0
0
0.3
0
_ 13
W
Exterior
Concrete Black - PolyslyrenBATH 3
9
6
0
9
7
57.5 ft2
0
0
0.3
0
_ 14
N
Exterior
Concrete Block - Polysty@htlB ROOM
9
24
0
10
2
244.0 ft2
0
0
0.3
0
_ 15
E
Exterior
Concrete Block - PolystyalbWB ROOM
9
19
0
10
2
193.2 ft2
0
0
0.3
0
_ 16
S
Exterior
Concrete Block - PolystyahBB ROOM
9
23
0
10
2
233.8 ft2
0
0
0.3
0
17
N
Exterior
Concrete Black - Polystyr@TeAIRS UP
9
17
0
9
7
162.9 ft2
0
0
0.3
0
_ 18
E
Exterior
Concrete Block - Polystyr@TGAIRS UP
9
12
0
9
7
115.0 ft2
0
0
0.3
0
_ 19
W
Exterior
Concrete Block - Polystyr&TGAIRS UP
9
17
0
9
7
162.9 ft2
0
0
0.3
0
20
S
Exterior
Concrete Block - PolystytWtNG/DININ
9
23
0
10
1
231.9 ft2
0
0
0.3
0
_ 21
N
Garage
Concrete Block - Polystyi@ WAGE EL
9
7
0
10
1
70.6 112
0
0
0.3
0
_ 22
W
Garage
Concrete Block - Polystyi@06?AGE EL
9
7
0
10
1
70.6 ft2
0
0
0.3
0
_ 23
S
Garage
Concrete Block - Polyslyi@dr£2AGE EL
9
7
0
10
1
70.6 ft2
0
0
0.3
0
24
E
Garage
Concrete Block - PolyslyiGYWAGE EL
9
7
0
10
1
70.6 ft2
0
0
0.3
0
25
N
Exterior
Concrete Block- PolystyrerWTILITY
9
11
0
10
1
110.9 ft2
0
0
0.3
0
26
W
Exterior
Concrete Block - PolystyrerldTILITY
9
8
0
10
1
80.7 ft2
0
0
0.3
0
27
W
Exterior
Concrete Block - Polysty&Ti@RAGE W
9
8
0
10
1
80.7 ft2
0
0
0.3
0
_ 28
N
Exterior
Concrete Block - PolystyrenEOYER
9
9
0
10
1
90.8 ft2
0
0
0.3
0
_ 29
N
Exterior
Concrete Block - PolystyrerR ANTRY
9
15
0
10
1
151.3 ft2
0
0
0.3
0
_ 30
E
Exterior
Concrete Block - PolystyreWNTRY
9
1
0
10
1
10.1 ft2
0
0
0.3
0
31
W
Exterior
Concrete Block - PolystyredSANTRY
9
1
0
10
1
10.1 ft2
0
0
0.3
0
_ 32
N
Exterior
Concrete Block - PolyslyrEd@ CHASE
9
4
0
10
1
40.3 ft2
0
0
0.3
0
_ 33
E
Exterior
Concrete Block - PolystyREmROOM 2
9
7
0
10
1
70.6 ft2
0
0
0.3
0
_ 34
S
Exterior
Concrete Block - PolystyREmROOM 2
9
14
0
10
1
141.2 ft2
0
0
0.3
0
_ 35
W
Exterior
Concrete Block - PolystyMDROOM 2
9
14
0
10
1
141.2 ft2
0
0
0.3
0
_ 36
SE
Exterior
Concrete Block - PolystyrenNALL 2
9
4
3
10
1
42.9 ft2
0
0
0.3
0
37
W
Exterior
Concrete Block - PolystyrenBATH 2
9
12
0
10
1
121.0 ft2
0
0
0.3
0
WINDOWS
Orientation shown
is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
_
1
E 1
Metal Low-E Single Yes
0.65
0.25
N
5.3 ft2
2 ft 0 in
1 ft 4 in
None
None
_
2
E 2
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
2 ft 0 in
1 It 4 in
None
None
3
S 3
Metal Low-E Single Yes
0.65
0.25
N
36.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
S 3
Metal Low-E Single Yes
0.65
0.25
N
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
5
W 4
Metal Low-E Single Yes
0.65
0.3
N
21.3 ft2
8 ft 0 in
1 ft 4 in
None
None
_
6
N 6
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
E 7
Metal Low-E Single Yes
0.65
0.25
N
5.0 ft2
2 ft 0 in
1 It 4 in
None
None
8
SE 8
Metal Low-E Single Yes
0.65
0.3
N
20.7 ft2
12 ft 0 in
1 ft 4 in
None
None
_
9
S 10
Metal Low-E Single Yes
0.65
0.25
N
45.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
10
W 13
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
11
N 14
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
12
E 15
Metal Low-E Single Yes
0.65
0.25
N
9.0 ft2
2 ft 0 in
1 It 4 in
None
None
13
S 16
Metal Low-E Single Yes
0.65
0.3
N
128.0 ft2
14 ft 0 in
1 ft 4 in
None
None
1/28/2020 3:28 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth Separation
Int Shade
Screening
_ 14
N 17 Metal
Low-E Single
Yes
0.65 0.25 N
18.0 T 2 ft 0 in 1 ft4 in
None
None
_ 15
W 19 Metal
Low-E Single
Yes
0.65 0.25 N
20.0 ft- 2 It 0 in 1 It 4 in
None
None
_ 16
S 20 Metal
Low-E Single
Yes
0.65 0.3 N
128.0 It- 14 It 0 in 1 ft 4 in
None
None
17
N 25 Metal
Low-E Single
Yes
0.65 0.25 N
20.0 ft2 2 ft 0 in 1 ft 4 in
None
None
18
N 28 Metal
Low-E Single
Yes
0.65 0.3 N
48.0 ft2 8 ft 0 in 1 ft 4In
None
None
19
N 29 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 2 fl0 in 1 ft 4In
None
None
_ 20
S 34 Metal
Low-E Single
Yes
0.65 0.25 N
54.0 ft2 2 ft 0 in 1 ft 4 in
None
None
21
BE 36 Metal
Low-E Single
Yes
0.65 0.3 N
20.7 112 12 It 0 in 1 ft 4 in
None
None
22
W 37 Metal
Low-E Single
Yes
0.65 0.25 N
8.0 ft2 2 It 0 in 1 ft 4 in
None
None
23
W 37 Metal
Low-E Single
Yes
0.65 0.25 N
8.0 ft2 2.110 in 1 It 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall insulation
1
2750 ft2
2750 ft2
28 ft
a ft
9
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000446
4261 233.92 439.93 .1693
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
_ 1
Electric Strip Heat/
None
COPA
27 kBtu/hr
1
sys#1
_ 2
Electric Strip Heat/
None
C0P:1
17 kBtu/hr
2
sys#2
3
Electric Strip Heat/
None
COPA
17 kBtu/hr
3
sys#3
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
35.2 kBtu/hr 1056 cfm
0.8 1
sys#1
2
Central Unit/
Split
Single SEER: 16
17.7 kBtu/hr 531 cfm
0.8 2
sys#2
3
Central Unit/
Split
Single SEER: 16
23.8 kBtu/hr 714 cfm
0.8 3
sys#3
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric
None
Garage
0.98 85 gal 67.4 gal 120 deg
None
1/28/2020 3:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 7 of 8
rnDnn Dnnr-,)n17 INN IT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/ ---- Supply--
-- Return ----
Air
CFM 25 CFM25
HVAC #
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT ON RLF
Heal Cool
_ 1 Attic
6 150 ft2
Attic
15 ft'
Default Leakage
Garage
(Default) c(Default) c
1 1
_ 2 Attic
6 125 ft2
Attic
13 1112
Default Leakage
Garage
(Default) c(Default) c
2 2
_ 3 Attic
6 140 ft2
Attic
14 ft2
Default Leakage
All
(Default) c(Default) c
3 3
TEMPERATURES
Programable[Thermostat:
Ceiling Fans:Cool
f
Heating r Jan pCl
111N [x�
Feb Mar
May
Jun[X11
i Jun r 1 Jul
j ]
ri Aug
[ 1 j[Xj�
[xl Sep Oct
Dec
[[Xj]
Venting [ 1 Jan [r
Feb IXl Mar
l l
Apr
] May
l Jun r I Jul
r 1 Aug
[ 1 Sep [XJ
Nov
[ J Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8 9 10
11
12
Cooling(WD)
AM 78
78
78
78
78 78
78
78 80 80
80
80
PM 80
80
80
80
78 78
78
78 78 78
78
78
Cooling (WEH)
AM 78
78
78
78
78 78
78
78 80 80
80
80
PM 80
80
80
80
78 78
78
78 78 78
78
78
Heating(WD)
AM 65
65
65
65
65 65
65
68 68 68
68
68
PM 68
68
68
68
68 68
68
68 68 68
68
68
Heating (WEH)
AM 65
65
65
65
65 65
65
68 68 68
68
68
PM 68
68
68
68
68 68
68
68 68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
112
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft2
ft
0.3
FOYERIGREAT RO