Loading...
HomeMy WebLinkAboutNettles Island #7 BathHse - AppAll APPLICABLE I FO MU T BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: O Permit Number: i Building Permit Application Planning and Development Services Building and Code Regulation Division 1300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential PERMIT APPLICATION FOR: Address: Legal Description: Property Tax ID #: Lot No. Slte Plan Name: A_)1:ff(Le_S ( Block No. Project Name: Setbacks Front Back: Right Side: Left Side: Additional work o bepe Orme under tis permit -Check all thatappy: _Mechanical _Gas Tank _Gas Piping _Shutters _Windows/Doors _Electric _Plumbing _Sprinklers _ Generator ✓Roof "2 i' Pitch Total Sq. Ft of Construction: ) Sq. Ft. of First Floor: Cost of Construction: $ o.00Utilities: —Sewer —Septic Building Height: t, Name Name: T. (' Address: 4 O , �,Vj � _ ompany: �/I,4 5 City: -SP S� _z c-4 State. �'-Address: G —�— �7 Zip Code: Fax: City: _ State: _ Phone No. Zip Code: '3314-7 \ Fax: E -Mail: Phone No -7 23 -5--`f5- 1 i� Fill in fee simple Title Holder on next page ( if different E -Mail J,2.4c- rc�G ?Shfcr,4_4. , C 47729 from the Owner listed above) State or County License C if value of construction Is 2500 or more, a RECORDED Notice of Commencement is required. DESIGNER ENGINEER: _ Not Applicable MORTGAGE COMPANY: Not Applicable Name: Name: _ Address: Address: City: State: City: State: Zip: Phone Zip: Phone: /g /g FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Applicable Name: Name: _Not Address: Address: Type of Identification City: City: Produced Zip: Phone: Zip: Phone: REVIEWS FRONT ZONING SUPERVISOR v av iv¢ny wry I n 461 Un Arnuvt I; Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that Is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recordine vour Notice nf CnmmanrPm Pnt ✓✓ �. Signature caner/ Lessee/Contractor as or_Diiliner Signature of ontractor/License Holder STATE OF FLORIDA /IAA COUNTY O STATE OF FLORIDA COUNTYOF The forgoing instrugiant was acknowledged before me this � day off /J4/� 26_J© The forgoing instrument was acknowledged before me � by this day of /Yl 2� by /g /g (Name of pers n acknow edging) (Name of pe on cknowiedging ) (Signature of Notary Public- State of Florida) at a of Notary Public- State of Florida ) Personally Known I/ OR Produced Identification Personally Known i- OR Produced Identification Type of Identification Type of Identification Produced Produced Commission No. (Seal) Commission No. (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Fe_v77n14 aJYya,,, SCOTT L DOBBS `a„w:'dm,, SCOTT L DOBBS �: State of Florida -Notary Public F11 .-N tar Public My Commission Expires =: a,,,�1,r°� My Commission Expires September 13, 2022 September 13, 2022 Chief Building Official May 6, 2020 St Lucie County Building Department 2300 Virginia Avenue Ft Pierce, FL 34982 Reference: Nettles Island HOA Bath House 47 9801 S Ocean Drive Jensen Beach, FL 34957 Subject: New Roof Material — Pool Building The roofer may install Dynamic Metals 1" nail strip, 0.032aluminum panels on the existing one story pool bldg. per the attached FL- 21082-R2 Florida Test Report. #10X1" pancake head fasteners, spaced @ 6" from each end and 6" o/c/ field are to be installed in all zones. The required applied uplifts in their appropriate zones for a mean roof height of < 15 feet, in exposure "D" during a 170 mphuit,132 mph ad wind event are as follows: Zone #1 (45 psf) Zone #2 (-75 psf) Zone #3 (413 psf) The product, installed per the aforementioned pattern / spacing, has been tested to provide a maximum total uplift design pressure of 168.5 psf psf, clearly exceeding the requirements for all three zones If you have any questions, please call me at your convenience. Thank v� Dr. Ernest A. Kuonen, PE 022920 President, The Erring Corporation CA -8327 228 Moccasin Trail West Jupiter, FL 33458