HomeMy WebLinkAboutPolyglass FL5259-R29 with EvalWiir2020 Florida Building Code Online
Professional . t
A
dbpr
aQs Home lap In User Registration HotTopics Submit surcharge stats a Facts Publications Contact Us acts site Map Unks search
0Product Approval
e USER:Prod Public User
®ProduR Aoorpval Menu > Product or Application search > Application Ust > Applloeon Detell
FL # FL5259-R29
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext 242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechniwl@polyglaw.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888) 410-1375
Category Roofing
Subcategory Underlayments
Compliance Method Eva ua on abort from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
ASTM D226
Florida Ucense
PE -59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
10/21/2022
Validated By
John W. Knezevich, PE
2011
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4798
2011
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
https:/Avww.floridabuilding.org/pripr�_app GEVXOwtDgvbSgAaZp3Crk2vS%2feg01ipmaCfgJXCANGg3CNQhK30Sg%3d%3d 1/2
3/11/2020
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Florida Building Code Online
FM 4474
FRSA/TRI April 2012
UL 1897
Method 1 Option D
10/15/2019
10/16/2019
10/20/2019
12/10/2019
2011
2012
2012
summary or Products
FL # Modal, Number or Name
Description
5259.1 Polyglass Roof
Roofing undedayments
Underlayments
Limits of Use
Installation Instructions
Approved for use In HVHZ: Na
FL5259 R29 II 2019 SO FINAL ER POLYGLASS UNDERLAYMENTS F 2
R29.plif
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE -59166
Design Pressure: +N/A/ -622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular
ELS259 R29 E5AE 2019 10 FINAL R POLYGLASS UNDERLAYMENTS FL5259-
B28.Rdf
underlayment system (over concrete deck) for
use under foam -on the systems (where the
Created by Independent Third Party: Yes
undenayment forms part of the load -path).
Refer to ER Section 5.6.1 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
0a®
Contact Us :: 2801 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Codwraht 2007-2013 State of FlaHaa :: PHvacv Statement :: Acrel Statement :: Refund Statement
Under Florida law, small addresses are pudic records, If you do not want your e -mall address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees Ilcemsed under Chapter 455, F.S. must provide the Dep irtnem with an small address If they have one. The emails
Provided may be used for official communication wttn Me licensee. However small addresses are public record. If you do not wish to supply a personal address, please
Provide the Department with an email address which can be made available to the public. To determine If you are a licensee under chapter 455, RS., please dick here .
Product Approval Accepta:
IM W1 ® Fiq
Credit Card
Sate
https:ltwww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01ipmaCfgJXCANGg3CNQhK3OSg%3da/a3d 2i2
NEMO I etc.
CeKy7cote ofAuthonzotion #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-1125
1111 West Newport Center Drive FL5259-R29
Deerfield Beach, FL 33442
(954)233-1230
Date of issuance: 02/24/2009
Revision 25:10/14/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DEscRIPnON: Polyglass Roof Underlayments
LAaEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEmON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16
Prepared by:
�&...:;
Robert J.M. Nieminen, P.E.
a;�••.+ _r5,.f-_-;
Florida Registration No. 59166, Florida DCA ANE1983
CERTIFICATION OF INDEPENDENCE:
The facsimile seal appearing was authorized by Robert Nieminen, P.E. on
10/14/2019. This does not serve as an electronically signed document,
1. NEMO Ietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOIetc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
NNEMOletc.
1. SCOPe:
Sub -Category:
Underlayment
Compliance Statement:
Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated
compliance with the
following sections of the
61" Edition (2017) Florida Building Code through testing in accordance with the
following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Enft
2. STANDARDS:
Reference
Date
ERD (TST 6049)
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 /1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6163
2008
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1507.11.2
Physical Properties
ASTM D6509
2009
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entity
Examination
lReference
Daft
Enft
Examination
Reference
Date
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Tensile adhesion
P40390.04.15
04/03/2015
ERD (7317 6049)
Wind Uplift
11776.06.02
01/16/2003
ERDOV6049)
TA5103
P44360.30.14 -R1
05/18/2015
ERD (M 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Wind Uplift
PLYG-SC8905-05.16-1
05/17/2016
ERD (TST 6049)
ASTM D1970
P5110.04.07-1
04/11/2007
ERD (TST 6049)
ASTM D1970
PLYG-SC30130.06.16-1
06/27/2016
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD TST 6049)
Tensile adhesion
PLYG-5(10130.06.16-1
06/27/2016
ERD (TST 6049)
Wind Uplift
P30540.11.09 -RI
11/30/2009
ERD (TST 6049)
TAS 303
PLYG-5[30130.06.16-3
06/27/2016
ERD (TST 6049)
Tensile Adhesion
P11030.11.09-1
11/30/2009
ERD M 6049)
ASTM D1970/D4798
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
ERD (TST 6049)
ASTM D4977
P11030.11.09-3
11/30/2009
ERD (ri T 6049)
TAS 103
PLYG-SC33040.12.16
12/27/2016
ERD (TST 6049)
ASTM D1970
P33360.06.10
06/25/2010
ERD (TST 6049)
30/90 physicals
PLYG-SC31900.03.17
03/10/2017
ERD (TST 6049)
TAS 103
P33370.03.11
03/02/2011
ERD UST 6049)
TAS 103
PLYG-SC12115.08.17
08/08/2017
ERD OST 6049)
Tensile Adhesion
P33370.04.11
04/26/2011
ERD (TST 6049)
TA5103
PLYG-5[13035.08.17
10/31/2017
ERD (TST 6049)
ASTM D1970
P37300.30.11
10/19/2011
FM (1ST 1867)
Wind Uplift
3004091
01/12/2000
ERD (TST 6049)
TAS103
P40390.08.12-1
03/06/2012
WC -ES (EVIL 2396)
IBCCompliance
ESR -1697
04/01/2019
ERD (T57. 6049)
Tensile Adhesion
P40390.08.12-2
08/07/2012
M-D(CER 1592)
HVHZ Compliance
NOA 17-0614.22
07/06/2017
ERD OST 6049)
Tensile Adhesion
[41420.09.12-3
09/11/2012
MTI(TST 2508)
ASTM D4798
JX2OH7A
04/01/2008
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18
03/29/2018
ERD(TST 6049)
ASTM D1970
P45370.04.13
04/26/2013
NEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
01/11/2019
ERD(TST 6049)
Wind Uplift
P1738.02.U7-R2
04/29/2013
NEMO (TST 6049)
ASTM D6163
4S-PLYG38-002.01.19-A
01/24/2019
ERD (TST 6049)
Wind Uplift
11757.04.01.1.81
04/30/2013
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.05.19{
05/20/2019
ERD (TST 6049)
ASTM D6164
P37590.03.13 -3A
05/06/2013
NEMO(TST6049)
TA5103
4S-PLYG-18-M.10.19G
10/08/2019
ERD (TST 6049)
ASTM D6509
P37590.03.13 -1-R1
06/26/2013
NEMO (TST 6049)
TAS 103
4S-PLYG18-004.10.19-1
10/08/2019
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
NEMO (TST 6049)
TAS 103
4S.PLYG18-004.10.19-L
10/09/2019
ERD ITST 6049)
ASTM D4601
P45940.09.13
09/04/2013
NEMO (TST 6049)
TAS 103
41-PLYG-I9-SSUDL-01-A
10/10/2019
ERD ITST 6049)
Wind Uplift
P11751.05.03 -R3
11/26/2013
PRI (TST 5878)
Tensile Adhesion
PRIO1111
04/08/2002
ERD (TST 6049)
Wind Uplift
P11781.11.03 -R1
11/26/2013
PRI (TST 5878)
TAS 103
PUSA-018-02-01
07/14/2003
ERD (TST 6049)
30/90 physicals
P45270.05.14
05/12/2014
PRI (TST 5878)
TA$103
PUSA-035-02-01
09/29/2006
ERD DST 6049)
Tensile adhesion
6020.09.14-5
09/08/2014
PRI (TST 5878)
TA5103
PUSA-055-02-02
12/10/2007
ERD (TST 6049)
Tensile adhesion
6020.09.14-6
09/08/2014
PRI (TST 5878)
ASTM D6222
PUSA-061-02-02
01/28/2008
ERD (TST 6049)
Tensile adhesion
P46520.10.14
10/03/2014
PRI (TST 5878)
ASTM D6164
PUSA-OW-02-01
07/29/2009
ERD CM76049)
ASTM D1970/D4798
P43290.10.14
10/17/2014
Polyglass USA
PA Affidavit
Mule -Hide Cross Ltg
03/01/2008
NEMO ETC, LLC.
Evaluation Report P12060.02.09 -R25
CertiJkote OfAuthorhodon #32455
6- EDITION (2017) FRC
NON-HVHZ EVALUATION
FL5259-R29
PolWass Roof Underlayments,
(954) 233-1230
Revision
25:10/14/2019
Page 2 of 16
Entity Examination ReferenceDate Entity
ERD (TSr 6069) TAS 103 PLVG-SC7550.03.15 03/24/2015 Polyglass USA
uL(QUA9625)
4.
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
ONEMOjetc.
Examination Reference Date
Materials Affidavit Polystick Compound 08/18/2011
Quality Control Service Confirmation 09/13/2018
PRmcr DESCRIPnON:
Product
Specification
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex G TU
M -D 13-004
PA
Polyester -reinforced, modified bitumen tile underlayment
FRSA/TRI April 2012
composed of a sand -surfaced SBS modified bitumen back-
side and granule -surfaced APP modified bitumen top -side
Elastoflex S6 G
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
Mule -Hide SA -APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60 -mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60 -mil thick dual -layer rubberized asphalt
TAS 103
waterproofing membrane, fiberglass reinforced, with a
FRSA/TRI April 2012
polyester fabric surface
Mule -Hide SA -APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRI April 2012
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet' in the
'Two Ply System" from FRSA/TRI April 2012 (0412)
beneath mechanically fastened or adhered the roof
systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet" In the
`Two Ply System" from FRSA/TRI April 2012 (0412)
beneath mechanically fastened tile roof systems
Polyflex SA P
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
Polyflex SA P FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
Polystick IR -Xe
ASTM D1970
FL, PA
Nominal 60 -mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
TA5103
FL, PA, TX
Nominal 60 -mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012
membrane, glass fiber reinforced, surfaced with
polyclefinic film surface
NEMO ETC, I.I.C. Evaluation Report P12060.02.09 -R25
Certificate of Authorization#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 3 of 16
a.
4.18
4.
4.20
4.21
NNEMOletc.
PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
Polystick MU -X
ASTM D1970
FL, NV, PA
Nominal 54 -mil thick dual -layer rubberized asphalt
(See Section 5.8)
Wood Shakes
waterproofing membrane, fiberglass reinforced, with a
Undedayment
Asphalt Shingles
Nail -On Tile
polypropylene film surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60 -mil thick rubberized asphalt waterproofing
Yes
TAS 103
Yes
membrane with a 190 g/m2 polyester fabric surface
Yes
FRSA/TRI April 2012
Polystick TU P
TAS 103
TX
Nominal 130 -mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012
yes
membrane, glass-fiber/polyester reinforced, with a
Yes
Yes
Yes
granular surface
Polystick TU Plus
ASTM D1970
FL, PA
Nominal 80 -mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
No
FRSA/TRI April 2012
Yes
surface
S. LJMITATIDNs:
5.1 This is a building code evaluation. Neither NEMC) ( etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
NEMO ETC, U.C. Evaluation Report P32060.02.09 -R25
Oraftate ofAuthodzudan x32455 6^' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259.RZ9
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 4 of 16
TABLE 1: ROOF COVER OPTIONS
Wood Shakes
Undedayment
Asphalt Shingles
Nail -On Tile
Foam -0n Tile
Mate)
&Shingles
Slate
Elastobase
Yes
Yes
Yes
Yes
Yes
Yes
(Base Sheet in 2 -Pty rystem)
(Base Sheeting-,n,wswrn)
Elastobase P
yes
Yes
Yes
Yes
Yes
Yes
IBase Sheet In 2 -ply system)
(Base Sheet in 2 -ply system)
Polyglass Base
No
Yes
Yes
No
No
No
(Base Shenin2-plynnem)
lBase Sheet In 2 -ply system)
Polyglass G2 Base
No
Yes
Yes
No
No
No
(Base Sheet In 2 -Ply system)
(Base Sheet in 2 -ply system)
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex $6G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex 56 G FR
Yes
Yes
No
No
Yes
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
Yes
HydmGuard Tile Pro
Yes
Yes
Yes (See 55.1)
Yes
Yes
Yes
Mule -Hide SA -APP Cap
Yes
yes
Yes (See5.5.1)
No
Yes
Yes
Sheet
Mule -Hide SA -APP Cap
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Sheet(FR)
PolyflexG
Yes
Yes
Yes (See 5.5.11
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SA P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Palyflex SA P FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick IR -Xe
Yes
No
No
No
Yes
Yes
NEMO ETC, U.C. Evaluation Report P32060.02.09 -R25
Oraftate ofAuthodzudan x32455 6^' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259.RZ9
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 4 of 16
9
ONEMO etc.
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHE9VE / UNDERLAYMENT COMBINATIONS'
TA8LE 1: ROOF COVER OPTIONS
Substrates (designed to meet wind loads for project)
Adhesive
Approval
Underlayment
AsphaltShlnglas
Nall -On Tile Foam -On Tile
Metal
Wood Shakes
&Shingles
Slate
Polystick MTS Plus
Yes
Yes No
Yes
Yes
Yes
Pol ck MU-%
Yes
No No
Yes
Yes
Yes
Poysdck Max
No
Yes Yes (5ee5.5.11
Yes
No
No
Polystick TU P
No
Yes Yes (See 55.1)
No
No
No
Polystick TU Plus
Yes
Yes Yes (See 5.5.1)
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHE9VE / UNDERLAYMENT COMBINATIONS'
Florida Product
Substrates (designed to meet wind loads for project)
Adhesive
Approval
Underlayments
DAP Foam Touch'n Seal Storm Bond
Type Primer Materials)
Roof Tile Adhesive
FL14506
Polystick TU Max or Polystick TU Plus
Dow TIIeBondm
FL22525
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or
Polystick TU Plus
Engineered Woods System" Panels
HydraGuard Tile Pro,
Elastoflex G TU, Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA -APP
ICP Adhesives Polyset° AH -160
FL6332
Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex G, Polyflex SA P,
Polystick (all variations),
Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus
ASTM D41
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA -APP Cap Sheet, Mule -
ICP Adhesives Polyset° RTA -1
FL6276
Hide SA -APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR,
adhering
Insulation
Polystick TU Max, Polystick TU P or Polystick TU Plus
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type Primer Materials)
HydraGuard Dual Pro,
Deck /
(Optional) ASTM D41
plywood, OSB, Southern Yellow Pine or Huber
"21P
Engineered Woods System" Panels
HydraGuard Tile Pro,
sheathing
ASTM D41
structural concrete
Polystick (all variations),
ASTM D41
ASTM
ASTM C1289 Type 11 Class 1 polyisocyanurate, ASTM
Mule -Hide SA -APP Cap
self-
Sheet, Mule -Hide SA -APP
adhering
Insulation
or WB -3000
C1289 Type V polyisocyanurate-composite, DensDeck
Cap Sheet (FR), Polyflex
Prime or SECUROCK Gypsum -Fiber Roof Board
Base
N/A
ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide
SA P or Polyflex SA P FR
Sheet
Nail Base
Deck
ASTM D41
structural concrete
Elastoflex G TU, Elastoflex
hot asphalt
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Base
N/A
ASTM D226 felt, Elastobase, Elastobase P, Mule -Hide Nail
S6 G or Elastoflex S6 G FR
Sheet
Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Polyflex G or Polyflex G FR
torch-
Insulation
(Optional' ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber RoofBoard
Base
N/A
I
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
applied
Sheet
G2 Base or Polyglass Base
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09 -R25
Ce,V"e of AuthMzoNon#32455 6^' EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R29
Polyglass Roof Underlayments; 1954) 233-1230 Revision 25:10/14/2019
Page 5 of 16
ONEMOJetc.
5.6.1 Wind Resistance for Underlayment Systems in Foam -On Tile Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April
2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for
wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin
of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 3A or FBC 1609
for determination of design wind loads.
#1 Maximum Design Pressure =-52.5 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4 -inch wide strips of Elastoflex SA -V over all OSBjoints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Desien Pressure=-9ODsf
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Pius, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Desien Pressure= -97.5 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x I%" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12 -Inch o.c.
44 Maximum Design Pressure =-105 psf:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB -3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1J!" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#5 Maximum Design Pressure =-135 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Joints: Min. 4 -inch wide strips of Elastoflex SA -V over all plywood joints.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#6 Maximum Design Pressure =-315psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#7 Maximum Design Pressure =-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P32060.02.09 -R25
Certifto e ofAothodzatlon #32455 6- EDITION 12017) FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 6 of 16
ONEMOletc.
#8 Maximum Design Pressure =-30.0 osf':
Deck: Min. 15/32 -inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -flim top surface)
Fasteners: 11 ga. x 1.25 -Inch long x 1 -inch head diameter round metal cap nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#9 Maximum Design Pressure= -37.5 osf
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga, x 1.25 -inch long x 1 -Inch head diameter round metal cap nails
Spacing: 64nch o.c. at the 3 -inch wide side laps and 6 -Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#10 Maximum Design Pressure= -37.5 VW:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25 -inch long x 1 -Inch head diameter round metal cap nails
Spacing: 6 -inch o.c at the 3 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure =-45 osf•:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25 -Inch x 3/8 -Inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 4 -inch o.c. at the 2 -inch wide side laps and 4 -inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU, applied In full mopping of hot asphalt.
#12 Maximum Design Pressure =-45osf'
Deck:
Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Two (2) layers ASTM D226, Type II felt
Fasteners:
11 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing:
9 -inch o.c. at the 2 -Inch wide side laps and 9 -inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#13 Maximum Design Pressure= -45 osf:
Deck:
Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXI( Cap Fasteners
Spacing:
9 -Inch o.c. at the 2 -inch wide side laps and 18 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment:
Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure =-45.0 osf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing:
6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, U.C. Evaluation Report P12060.02.09 -R25
frrtQkote ofAuthoroadon X32455 6'" EDITION (2017) FSC NON-HVHZ EVALUATION FLSZ59.1129
Polyglass Roof Underiaymems; (954) 2334230 Revision 25:10/14/2019
Page 7 of 16
ON EMo I etc.
#15 Maximum Design Pressure =-45.0osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diametertin caps
Spacing: 6 -inch D.C. at the 3 -Inch wide side laps and &Inch D.C. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#16 Maximum Desien Pressure =-45.0 Dsf
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#17 Maximum Design Pressure =-52.5 osf:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch-applled rap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9 -Inch o.c. at the 2 -Inch wide side laps and 12 -inch D.C. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure =-52.5 osf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6 -Inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#19 Maximum Design Pressure= -52.5 osf:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#20 Maximum Design Pressure= -60 osf:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 8 -inch o.c. at the 4 -inch wide side laps and 8 -Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure =-60 osf:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12 -inch o.c. at the 4 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, LLC. Evaluation Report P12060.02.09 -R25
Certificate of Authorization #32455 a EDITION (2017) FBC NON-HVHZ EVALUATION FLS259-RZ9
"less Roof Underlayments, (954) 233-1230 Revision 25: 10/14/2019
Page 9 of 16
#22 Maximum Design Pressure = -60.0 ad: ONEMOletc.
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8 -Inch o.c. at the 3 -inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#23 Maximum Deslgn Pressure = -60.0 Dsf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8 -Inch o.c. at the 3 -Inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#24 Maximum Design Pressure = -60.0 Dsf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8 -inch o.c. at the 3 -inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#25 Maximum Design Pressure =-67 5 Dsf:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch-oppffed underloyment)
Fasteners: 12 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -Inch diameter tin caps
Spacing: 8 -inch o.c. at the 4 -inch wide side laps and 8 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#26 Maximum Design Pressure =-67 5 off:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12 -Inch o.c. at the 4 -inch wide side laps and 12 -Inch o.c. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#27 Maximum Design Pressure = -67.5 Dsf
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12 -inch o.c. at the 4 -inch wide side laps and 12 -Inch D.C. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt.
NEMO ETC, LLC
Evaluation Report P32060.02.09-1125
Certificate of Auftrization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 9 of 16
#28 Maximum Design Pressure= -67 5 osf: ONEMOletc.
Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12 -inch o.c. at the 4 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#29 Maximum Design Pressure = -75 osf:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: SO -inch o.c. at the 4 -Inch wide side laps and 10 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#30 Maximum Design Pressure = -90 osf
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6 -inch o.c. at the 2 -Inch wide side laps and 6 -Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#31 Maximum Design Pressure =-90 ad:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied rap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6 -Inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#32 Maximum Desien Pressure = -90 osf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt.
#33 Maximum Design Pressure= -90 osf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch-opplied underfayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9 -Inch o.c. at the 4 -inch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#34 Maximum Design Pressure= -900 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9 -Inch o.c. at the 2 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, U.C. Evaluation Report P12060.02.09 -R25
Certificate of Authorization #32455 6r` EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments, (954) 233-1230 Revision 25: 10/14/2019
Page 10 of 16
#35 Maximum Design Pressure =-90 0 osf: ONEMOletc.
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width-direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#36 Maximum Design Pressure =-90 0 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners & Plates with two (2) screws per plate installed 180° Into the holes of the plate, parallel to
the width-direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch-applied.
#37 Maximum Design Pressure =-97 5 osf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base (poly-film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self-adhered.
#38 Maximum Design Pressure =-97 5 nsf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base (poly-fllm top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self-adhered.
#39 Maximum Design Pressure =-97 5 osf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#40 Maximum Design Pressure = -97.5 osf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch-applied.
#41 Maximum Design Pressure=-105 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch-applied.
NEMO ETC, U.C. Evaluation Report P32060.02.09-1125
Cert/fkate ofauthorizatbn #32055 0 EDMON (2017) FBC NON-HVHZ EVALUATION FL5259-1129
Polyglass Roof Underlayments, (954) 233-1230 Revision 25:10/14/2019
Page 11 of 16
� ONEMOletc.
442 Maximum Design Pressure= -105.0
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#43 Maximum Design Pressure =-105.Oosf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#44 Maximum Design Pressure =-105.Oosf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#45 Maximum Design Pressure = -112.5 tni:
Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25 -inch x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG1OO or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#46 Maximum Design Pressure= -120 osf:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#47 Maximum Design Pressure= -120 osf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6 -Inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P12060.02.09 -R25
Certificate DfAuthonz,,Von #32455 6- EDITION (2017) FBC NON-HVH2 EVALUATION FL5299-R29
Polyglass Roof Underlayments, (954) 233-1230 Revision 25:10/14/2019
Page 12 of 16
ON EMO etc.
#48 Maximum Design Pressure =-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9 -inch o.c. at the 44nch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#49 Maximum Design Pressure= -127.5 osf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 94nch o.c. at the 4inch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows.
Undedayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#50 Maximum Design Pressure =-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9 -inch o.c. at the 4 -inch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design
Pressure of -45 psf.
5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012 (04-12), Appendix A, Table SA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Maximum Exposure (days)
Elastoflex G TU, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU
180
Max, Polystick TU P or Polystick TU Plus
Polystick IR -Xe or Polystick MU -X
90
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
30
180
(for adhesive -set tile)
Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet
(FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
UNLIMITED
(for mechanically fastened roof
prepared roof covers)
5.8 Polystick MU -X has been found through comparative testing to have a lesser coefficient Of friction than ASTM D226 roofing
felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in
Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
NEMO ETC, LLC. Evaluation Report P12060.02.09 -R25
Cern/ic#te ofAuthwization#32455 691 EDITION 120171 FBC NON-HVHZ EVALUATION FL5259-RZ9
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 13 of 16
ONEMOletc.
5.9 Tile Sliooaae Limitations (FRSA/TRI Aoril 2012 (04-121):
When loading roof tiles on the underiayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using battens during loading of the roof tiles.
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Luse:
6.3.1 Non -Tile Aoolications
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -
Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot
asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer
underlayment, as set forth in Table 1.
6.3.2 Tile Aoolications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two Ply
System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April
2012 (0412) Installation Manual.
NEMO ETC, LLC. Evaluation Report P12060.02.09-1125
Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5299-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 14 of 16
TABLE 2: TILE SUPPAGE LIMfTATIONs FOR DIRER -DECK TILE INSTALLATIONS
Underlaymem
Tile Profile Staging Method Maximum Slope
Elastoflex G TU
Flat 10 -tile stack 7:12
Lugged 8 -tile stack (6 over 2) 6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged 6 -tile stack (4 over 2) 4:12
HydraGuard Tile Pro
Flat or Lugged 6 -tile stack (4 over 2) 7:12
Polyflex G or G FR
Flat or Lugged 6 -tile stack (4 over 2) 4:12
Polyflex SA P or SA P FR
Flat or Lugged 6 -tile stack (4 over 2) 4:12
Polystick MTS Plus
Flat 6 -tile stack (4 over 2) 5:12
Lugged 6 -tile stack (4 over 2) 4:12
Polystick TU Max
Flat 6 -tile stack (4 over 2) or 10 -tile stack 7:12
Lugged 6 -tile stack (4 over 2) 7:12
Lugged 10 -tile stack 6:12
Polystick TU P
Flat 6 -tile stack (4 over 2) 6:12
Lugged 6 -tile stack (4 over 2) 4:12
Polystick TU Plus
Flat or Lugged 6-uie stack (4 over 2) 7:12
Flat or Lugged SD -tile stack 6:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Luse:
6.3.1 Non -Tile Aoolications
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -
Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot
asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer
underlayment, as set forth in Table 1.
6.3.2 Tile Aoolications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two Ply
System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April
2012 (0412) Installation Manual.
NEMO ETC, LLC. Evaluation Report P12060.02.09-1125
Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5299-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 14 of 16
ON EMO etc.
6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR, Polystick IR -Xe, Polystick MTS Plus, Polystick MU -X, Polystick TU Max, Polystick TU P or Polystick TU Plus:
6.4.1
6.4.2
6.4.3
6.4.4
General:
All seal -lap seams (selvage laps) must be firmly rolled with a in
accordance with Polyglass requirements to ensure full contact
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile
Pro, align the edge of the top sheet to the end of the glue
pattern (the sheet will overlap the fabric).
Vkm of Ovelep Seam of HydraGwrd Dual Pro and HydraGuard Tile Pro
Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements.
rile Applications (excludes HydraGuard Dual Pro, Polystick IR -Xe and Polystick MU -X):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI April 2012 (04-12) and
Polyglass published requirements.
For mechanically fastened tile roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet
fastening shall be not less than FRSA/TRI April 2012 (04.12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.1 herein.
Multi -Ply Underlavment Systems:
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU -X, Polystick TU Max,
Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are
those associated with the top -layer material. This is not a requirement, but is allowable if a 2 -ply underlayment system is
desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2 -ply underlayment system is desired.
6.5 I Elastoflex G TU, Elastoflex 56 6 or Elastaflex 56 6 FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"
from FRSA/TRI April 2012 (0412) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
in the "Two Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened or adhered the roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"
from FRSA/TRI April 2012 (0412) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
In the'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap
Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened tile roof systems.
NEMO ETC, LLC. Evaluation Report P12060.02.09-RZ5
Certificate of AuthonzWon #32455 6'"EDITION (2017)FOC NON-HVHZ EVALUATION FL5259.R29
Polyglass Roof Undedaymems, (954) 233.1230 Revision 25:10/14/2019
Page 15 of 16
. .. F
ONEMO I etc.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates
noted in Table 2. Side laps shall be minimum 3 -Inch and end -laps minimum 6 -inch wide, off -set minimum 3 feet from course
to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8 -Inch beyond the lap edge.
6.6 Polyflex G or Polyllex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet' In the 'Two Ply System" from FRSA/TRI April 2012 (04-
12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3 -inch and
end -laps minimum 6 -inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8 -inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2
herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA(TRI April 2012 (0412) must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile
sliding and/or damage to the underlayment during the loading process.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. 61620-3 QA requirements. Refer to
Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENmr.
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC. Evaluation Report P12060.02.09-1125
Certffimte of Authorization#32455 6T" EDITION (2017) FEE NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 16 of 16