Loading...
HomeMy WebLinkAboutPolyglass FL5259-R29 with EvalWiir2020 Florida Building Code Online Professional . t A dbpr aQs Home lap In User Registration HotTopics Submit surcharge stats a Facts Publications Contact Us acts site Map Unks search 0Product Approval e USER:Prod Public User ®ProduR Aoorpval Menu > Product or Application search > Application Ust > Applloeon Detell FL # FL5259-R29 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext 242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)802-8017 uspolyglasstechniwl@polyglaw.com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888) 410-1375 Category Roofing Subcategory Underlayments Compliance Method Eva ua on abort from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report ASTM D226 Florida Ucense PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE 2011 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 https:/Avww.floridabuilding.org/pripr�_app GEVXOwtDgvbSgAaZp3Crk2vS%2feg01ipmaCfgJXCANGg3CNQhK30Sg%3d%3d 1/2 3/11/2020 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Florida Building Code Online FM 4474 FRSA/TRI April 2012 UL 1897 Method 1 Option D 10/15/2019 10/16/2019 10/20/2019 12/10/2019 2011 2012 2012 summary or Products FL # Modal, Number or Name Description 5259.1 Polyglass Roof Roofing undedayments Underlayments Limits of Use Installation Instructions Approved for use In HVHZ: Na FL5259 R29 II 2019 SO FINAL ER POLYGLASS UNDERLAYMENTS F 2 R29.plif Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE -59166 Design Pressure: +N/A/ -622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular ELS259 R29 E5AE 2019 10 FINAL R POLYGLASS UNDERLAYMENTS FL5259- B28.Rdf underlayment system (over concrete deck) for use under foam -on the systems (where the Created by Independent Third Party: Yes undenayment forms part of the load -path). Refer to ER Section 5.6.1 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. 0a® Contact Us :: 2801 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Codwraht 2007-2013 State of FlaHaa :: PHvacv Statement :: Acrel Statement :: Refund Statement Under Florida law, small addresses are pudic records, If you do not want your e -mall address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to section 455.275(1), Florida Statutes, effective October 1, 2012, licensees Ilcemsed under Chapter 455, F.S. must provide the Dep irtnem with an small address If they have one. The emails Provided may be used for official communication wttn Me licensee. However small addresses are public record. If you do not wish to supply a personal address, please Provide the Department with an email address which can be made available to the public. To determine If you are a licensee under chapter 455, RS., please dick here . Product Approval Accepta: IM W1 ® Fiq Credit Card Sate https:ltwww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01ipmaCfgJXCANGg3CNQhK3OSg%3da/a3d 2i2 NEMO I etc. CeKy7cote ofAuthonzotion #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-1125 1111 West Newport Center Drive FL5259-R29 Deerfield Beach, FL 33442 (954)233-1230 Date of issuance: 02/24/2009 Revision 25:10/14/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DEscRIPnON: Polyglass Roof Underlayments LAaEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEmON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 16 Prepared by: �&...:; Robert J.M. Nieminen, P.E. a;�••.+ _r5,.f-_-; Florida Registration No. 59166, Florida DCA ANE1983 CERTIFICATION OF INDEPENDENCE: The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/14/2019. This does not serve as an electronically signed document, 1. NEMO Ietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOIetc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC NNEMOletc. 1. SCOPe: Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 61" Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Enft 2. STANDARDS: Reference Date ERD (TST 6049) Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 /1507.1.1 Physical Properties ASTM D226 2009 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination lReference Daft Enft Examination Reference Date ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Tensile adhesion P40390.04.15 04/03/2015 ERD (7317 6049) Wind Uplift 11776.06.02 01/16/2003 ERDOV6049) TA5103 P44360.30.14 -R1 05/18/2015 ERD (M 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Wind Uplift PLYG-SC8905-05.16-1 05/17/2016 ERD (TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 ERD (TST 6049) ASTM D1970 PLYG-SC30130.06.16-1 06/27/2016 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD TST 6049) Tensile adhesion PLYG-5(10130.06.16-1 06/27/2016 ERD (TST 6049) Wind Uplift P30540.11.09 -RI 11/30/2009 ERD (TST 6049) TAS 303 PLYG-5[30130.06.16-3 06/27/2016 ERD (TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD M 6049) ASTM D1970/D4798 PLYG-SC8080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) ASTM D4977 P11030.11.09-3 11/30/2009 ERD (ri T 6049) TAS 103 PLYG-SC33040.12.16 12/27/2016 ERD (TST 6049) ASTM D1970 P33360.06.10 06/25/2010 ERD (TST 6049) 30/90 physicals PLYG-SC31900.03.17 03/10/2017 ERD (TST 6049) TAS 103 P33370.03.11 03/02/2011 ERD UST 6049) TAS 103 PLYG-SC12115.08.17 08/08/2017 ERD OST 6049) Tensile Adhesion P33370.04.11 04/26/2011 ERD (TST 6049) TA5103 PLYG-5[13035.08.17 10/31/2017 ERD (TST 6049) ASTM D1970 P37300.30.11 10/19/2011 FM (1ST 1867) Wind Uplift 3004091 01/12/2000 ERD (TST 6049) TAS103 P40390.08.12-1 03/06/2012 WC -ES (EVIL 2396) IBCCompliance ESR -1697 04/01/2019 ERD (T57. 6049) Tensile Adhesion P40390.08.12-2 08/07/2012 M-D(CER 1592) HVHZ Compliance NOA 17-0614.22 07/06/2017 ERD OST 6049) Tensile Adhesion [41420.09.12-3 09/11/2012 MTI(TST 2508) ASTM D4798 JX2OH7A 04/01/2008 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO (TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018 ERD(TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO (TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019 ERD(TST 6049) Wind Uplift P1738.02.U7-R2 04/29/2013 NEMO (TST 6049) ASTM D6163 4S-PLYG38-002.01.19-A 01/24/2019 ERD (TST 6049) Wind Uplift 11757.04.01.1.81 04/30/2013 NEMO (TST 6049) ASTM D6222 4S-PLYG-18-002.05.19{ 05/20/2019 ERD (TST 6049) ASTM D6164 P37590.03.13 -3A 05/06/2013 NEMO(TST6049) TA5103 4S-PLYG-18-M.10.19G 10/08/2019 ERD (TST 6049) ASTM D6509 P37590.03.13 -1-R1 06/26/2013 NEMO (TST 6049) TAS 103 4S-PLYG18-004.10.19-1 10/08/2019 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO (TST 6049) TAS 103 4S.PLYG18-004.10.19-L 10/09/2019 ERD ITST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO (TST 6049) TAS 103 41-PLYG-I9-SSUDL-01-A 10/10/2019 ERD ITST 6049) Wind Uplift P11751.05.03 -R3 11/26/2013 PRI (TST 5878) Tensile Adhesion PRIO1111 04/08/2002 ERD (TST 6049) Wind Uplift P11781.11.03 -R1 11/26/2013 PRI (TST 5878) TAS 103 PUSA-018-02-01 07/14/2003 ERD (TST 6049) 30/90 physicals P45270.05.14 05/12/2014 PRI (TST 5878) TA$103 PUSA-035-02-01 09/29/2006 ERD DST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 PRI (TST 5878) TA5103 PUSA-055-02-02 12/10/2007 ERD (TST 6049) Tensile adhesion 6020.09.14-6 09/08/2014 PRI (TST 5878) ASTM D6222 PUSA-061-02-02 01/28/2008 ERD (TST 6049) Tensile adhesion P46520.10.14 10/03/2014 PRI (TST 5878) ASTM D6164 PUSA-OW-02-01 07/29/2009 ERD CM76049) ASTM D1970/D4798 P43290.10.14 10/17/2014 Polyglass USA PA Affidavit Mule -Hide Cross Ltg 03/01/2008 NEMO ETC, LLC. Evaluation Report P12060.02.09 -R25 CertiJkote OfAuthorhodon #32455 6- EDITION (2017) FRC NON-HVHZ EVALUATION FL5259-R29 PolWass Roof Underlayments, (954) 233-1230 Revision 25:10/14/2019 Page 2 of 16 Entity Examination ReferenceDate Entity ERD (TSr 6069) TAS 103 PLVG-SC7550.03.15 03/24/2015 Polyglass USA uL(QUA9625) 4. 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 ONEMOjetc. Examination Reference Date Materials Affidavit Polystick Compound 08/18/2011 Quality Control Service Confirmation 09/13/2018 PRmcr DESCRIPnON: Product Specification Plant(s) Description Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet Elastoflex G TU M -D 13-004 PA Polyester -reinforced, modified bitumen tile underlayment FRSA/TRI April 2012 composed of a sand -surfaced SBS modified bitumen back- side and granule -surfaced APP modified bitumen top -side Elastoflex S6 G ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI April 2012 Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI April 2012 Mule -Hide SA -APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 HydraGuard Dual Pro ASTM D1970 FL Nominal 60 -mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface HydraGuard Tile Pro ASTM D1970 FL Nominal 60 -mil thick dual -layer rubberized asphalt TAS 103 waterproofing membrane, fiberglass reinforced, with a FRSA/TRI April 2012 polyester fabric surface Mule -Hide SA -APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet (FR) FRSA/TRI April 2012 Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened or adhered the roof systems Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet" In the `Two Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened tile roof systems Polyflex SA P ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 Polyflex SA P FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet Polystick IR -Xe ASTM D1970 FL, PA Nominal 60 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface Polystick MTS Plus TA5103 FL, PA, TX Nominal 60 -mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane, glass fiber reinforced, surfaced with polyclefinic film surface NEMO ETC, I.I.C. Evaluation Report P12060.02.09 -R25 Certificate of Authorization#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 3 of 16 a. 4.18 4. 4.20 4.21 NNEMOletc. PRODUCT DESCRIPTION: Product Specification Plant(s) Description Polystick MU -X ASTM D1970 FL, NV, PA Nominal 54 -mil thick dual -layer rubberized asphalt (See Section 5.8) Wood Shakes waterproofing membrane, fiberglass reinforced, with a Undedayment Asphalt Shingles Nail -On Tile polypropylene film surface Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60 -mil thick rubberized asphalt waterproofing Yes TAS 103 Yes membrane with a 190 g/m2 polyester fabric surface Yes FRSA/TRI April 2012 Polystick TU P TAS 103 TX Nominal 130 -mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 yes membrane, glass-fiber/polyester reinforced, with a Yes Yes Yes granular surface Polystick TU Plus ASTM D1970 FL, PA Nominal 80 -mil thick rubberized asphalt waterproofing TAS 103 membrane, glass fiber reinforced, with a polyester fabric No FRSA/TRI April 2012 Yes surface S. LJMITATIDNs: 5.1 This is a building code evaluation. Neither NEMC) ( etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: NEMO ETC, U.C. Evaluation Report P32060.02.09 -R25 Oraftate ofAuthodzudan x32455 6^' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259.RZ9 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 4 of 16 TABLE 1: ROOF COVER OPTIONS Wood Shakes Undedayment Asphalt Shingles Nail -On Tile Foam -0n Tile Mate) &Shingles Slate Elastobase Yes Yes Yes Yes Yes Yes (Base Sheet in 2 -Pty rystem) (Base Sheeting-,n,wswrn) Elastobase P yes Yes Yes Yes Yes Yes IBase Sheet In 2 -ply system) (Base Sheet in 2 -ply system) Polyglass Base No Yes Yes No No No (Base Shenin2-plynnem) lBase Sheet In 2 -ply system) Polyglass G2 Base No Yes Yes No No No (Base Sheet In 2 -Ply system) (Base Sheet in 2 -ply system) Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex $6G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex 56 G FR Yes Yes No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes HydmGuard Tile Pro Yes Yes Yes (See 55.1) Yes Yes Yes Mule -Hide SA -APP Cap Yes yes Yes (See5.5.1) No Yes Yes Sheet Mule -Hide SA -APP Cap Yes Yes Yes (See 5.5.1) No Yes Yes Sheet(FR) PolyflexG Yes Yes Yes (See 5.5.11 No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SA P Yes Yes Yes (See 5.5.1) No Yes Yes Palyflex SA P FR Yes Yes Yes (See 5.5.1) No Yes Yes Polystick IR -Xe Yes No No No Yes Yes NEMO ETC, U.C. Evaluation Report P32060.02.09 -R25 Oraftate ofAuthodzudan x32455 6^' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259.RZ9 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 4 of 16 9 ONEMO etc. 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHE9VE / UNDERLAYMENT COMBINATIONS' TA8LE 1: ROOF COVER OPTIONS Substrates (designed to meet wind loads for project) Adhesive Approval Underlayment AsphaltShlnglas Nall -On Tile Foam -On Tile Metal Wood Shakes &Shingles Slate Polystick MTS Plus Yes Yes No Yes Yes Yes Pol ck MU-% Yes No No Yes Yes Yes Poysdck Max No Yes Yes (5ee5.5.11 Yes No No Polystick TU P No Yes Yes (See 55.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHE9VE / UNDERLAYMENT COMBINATIONS' Florida Product Substrates (designed to meet wind loads for project) Adhesive Approval Underlayments DAP Foam Touch'n Seal Storm Bond Type Primer Materials) Roof Tile Adhesive FL14506 Polystick TU Max or Polystick TU Plus Dow TIIeBondm FL22525 HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus Engineered Woods System" Panels HydraGuard Tile Pro, Elastoflex G TU, Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA -APP ICP Adhesives Polyset° AH -160 FL6332 Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polystick (all variations), Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus ASTM D41 Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA -APP Cap Sheet, Mule - ICP Adhesives Polyset° RTA -1 FL6276 Hide SA -APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, adhering Insulation Polystick TU Max, Polystick TU P or Polystick TU Plus 5.6 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Materials) HydraGuard Dual Pro, Deck / (Optional) ASTM D41 plywood, OSB, Southern Yellow Pine or Huber "21P Engineered Woods System" Panels HydraGuard Tile Pro, sheathing ASTM D41 structural concrete Polystick (all variations), ASTM D41 ASTM ASTM C1289 Type 11 Class 1 polyisocyanurate, ASTM Mule -Hide SA -APP Cap self- Sheet, Mule -Hide SA -APP adhering Insulation or WB -3000 C1289 Type V polyisocyanurate-composite, DensDeck Cap Sheet (FR), Polyflex Prime or SECUROCK Gypsum -Fiber Roof Board Base N/A ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide SA P or Polyflex SA P FR Sheet Nail Base Deck ASTM D41 structural concrete Elastoflex G TU, Elastoflex hot asphalt Insulation (Optional) ASTM D41 DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Base N/A ASTM D226 felt, Elastobase, Elastobase P, Mule -Hide Nail S6 G or Elastoflex S6 G FR Sheet Base or Polyglass G2 Base Deck ASTM D41 structural concrete Polyflex G or Polyflex G FR torch- Insulation (Optional' ASTM D41 DensDeck Prime or SECUROCK Gypsum -Fiber RoofBoard Base N/A I Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass applied Sheet G2 Base or Polyglass Base 'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09 -R25 Ce,V"e of AuthMzoNon#32455 6^' EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R29 Polyglass Roof Underlayments; 1954) 233-1230 Revision 25:10/14/2019 Page 5 of 16 ONEMOJetc. 5.6.1 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 3A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure =-52.5 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min. 4 -inch wide strips of Elastoflex SA -V over all OSBjoints Base Ply: Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #2 Maximum Desien Pressure=-9ODsf Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Pius, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #3 Maximum Desien Pressure= -97.5 psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x I%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -Inch o.c. 44 Maximum Design Pressure =-105 psf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB -3000 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1J!" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c. #5 Maximum Design Pressure =-135 psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Joints: Min. 4 -inch wide strips of Elastoflex SA -V over all plywood joints. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #6 Maximum Design Pressure =-315psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: HydraGuard Tile Pro, Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #7 Maximum Design Pressure =-622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, U.C. Evaluation Report P32060.02.09 -R25 Certifto e ofAothodzatlon #32455 6- EDITION 12017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 6 of 16 ONEMOletc. #8 Maximum Design Pressure =-30.0 osf': Deck: Min. 15/32 -inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -flim top surface) Fasteners: 11 ga. x 1.25 -Inch long x 1 -inch head diameter round metal cap nails Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #9 Maximum Design Pressure= -37.5 osf Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga, x 1.25 -inch long x 1 -Inch head diameter round metal cap nails Spacing: 64nch o.c. at the 3 -inch wide side laps and 6 -Inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #10 Maximum Design Pressure= -37.5 VW: Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt Fasteners: 11 ga. x 1.25 -inch long x 1 -Inch head diameter round metal cap nails Spacing: 6 -inch o.c at the 3 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #11 Maximum Design Pressure =-45 osf•: Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25 -Inch x 3/8 -Inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps Spacing: 4 -inch o.c. at the 2 -inch wide side laps and 4 -inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex G TU, applied In full mopping of hot asphalt. #12 Maximum Design Pressure =-45osf' Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps Spacing: 9 -inch o.c. at the 2 -Inch wide side laps and 9 -inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt. #13 Maximum Design Pressure= -45 osf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXI( Cap Fasteners Spacing: 9 -Inch o.c. at the 2 -inch wide side laps and 18 -inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Design Pressure =-45.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, U.C. Evaluation Report P12060.02.09 -R25 frrtQkote ofAuthoroadon X32455 6'" EDITION (2017) FSC NON-HVHZ EVALUATION FLSZ59.1129 Polyglass Roof Underiaymems; (954) 2334230 Revision 25:10/14/2019 Page 7 of 16 ON EMo I etc. #15 Maximum Design Pressure =-45.0osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diametertin caps Spacing: 6 -inch D.C. at the 3 -Inch wide side laps and &Inch D.C. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #16 Maximum Desien Pressure =-45.0 Dsf Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #17 Maximum Design Pressure =-52.5 osf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch-applled rap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9 -Inch o.c. at the 2 -Inch wide side laps and 12 -inch D.C. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure =-52.5 osf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6 -Inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #19 Maximum Design Pressure= -52.5 osf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #20 Maximum Design Pressure= -60 osf: Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps Spacing: 8 -inch o.c. at the 4 -inch wide side laps and 8 -Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure =-60 osf: Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12 -inch o.c. at the 4 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, LLC. Evaluation Report P12060.02.09 -R25 Certificate of Authorization #32455 a EDITION (2017) FBC NON-HVHZ EVALUATION FLS259-RZ9 "less Roof Underlayments, (954) 233-1230 Revision 25: 10/14/2019 Page 9 of 16 #22 Maximum Design Pressure = -60.0 ad: ONEMOletc. Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8 -Inch o.c. at the 3 -inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #23 Maximum Deslgn Pressure = -60.0 Dsf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8 -Inch o.c. at the 3 -Inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt. #24 Maximum Design Pressure = -60.0 Dsf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8 -inch o.c. at the 3 -inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #25 Maximum Design Pressure =-67 5 Dsf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch-oppffed underloyment) Fasteners: 12 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -Inch diameter tin caps Spacing: 8 -inch o.c. at the 4 -inch wide side laps and 8 -inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #26 Maximum Design Pressure =-67 5 off: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12 -Inch o.c. at the 4 -inch wide side laps and 12 -Inch o.c. at two (2) equally spaced staggered center rows. Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #27 Maximum Design Pressure = -67.5 Dsf Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12 -inch o.c. at the 4 -inch wide side laps and 12 -Inch D.C. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt. NEMO ETC, LLC Evaluation Report P32060.02.09-1125 Certificate of Auftrization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 9 of 16 #28 Maximum Design Pressure= -67 5 osf: ONEMOletc. Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12 -inch o.c. at the 4 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #29 Maximum Design Pressure = -75 osf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: SO -inch o.c. at the 4 -Inch wide side laps and 10 -inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #30 Maximum Design Pressure = -90 osf Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6 -inch o.c. at the 2 -Inch wide side laps and 6 -Inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #31 Maximum Design Pressure =-90 ad: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied rap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6 -Inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #32 Maximum Desien Pressure = -90 osf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt. #33 Maximum Design Pressure= -90 osf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch-opplied underfayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9 -Inch o.c. at the 4 -inch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #34 Maximum Design Pressure= -900 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9 -Inch o.c. at the 2 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, U.C. Evaluation Report P12060.02.09 -R25 Certificate of Authorization #32455 6r` EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments, (954) 233-1230 Revision 25: 10/14/2019 Page 10 of 16 #35 Maximum Design Pressure =-90 0 osf: ONEMOletc. Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #36 Maximum Design Pressure =-90 0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners & Plates with two (2) screws per plate installed 180° Into the holes of the plate, parallel to the width-direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch-applied. #37 Maximum Design Pressure =-97 5 osf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base (poly-film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self-adhered. #38 Maximum Design Pressure =-97 5 nsf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base (poly-fllm top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self-adhered. #39 Maximum Design Pressure =-97 5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #40 Maximum Design Pressure = -97.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch-applied. #41 Maximum Design Pressure=-105 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch-applied. NEMO ETC, U.C. Evaluation Report P32060.02.09-1125 Cert/fkate ofauthorizatbn #32055 0 EDMON (2017) FBC NON-HVHZ EVALUATION FL5259-1129 Polyglass Roof Underlayments, (954) 233-1230 Revision 25:10/14/2019 Page 11 of 16 � ONEMOletc. 442 Maximum Design Pressure= -105.0 Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #43 Maximum Design Pressure =-105.Oosf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt. #44 Maximum Design Pressure =-105.Oosf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #45 Maximum Design Pressure = -112.5 tni: Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25 -inch x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows. Primer: PG1OO or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS Plus, self -adhered Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #46 Maximum Design Pressure= -120 osf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #47 Maximum Design Pressure= -120 osf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6 -Inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, U.C. Evaluation Report P12060.02.09 -R25 Certificate DfAuthonz,,Von #32455 6- EDITION (2017) FBC NON-HVH2 EVALUATION FL5299-R29 Polyglass Roof Underlayments, (954) 233-1230 Revision 25:10/14/2019 Page 12 of 16 ON EMO etc. #48 Maximum Design Pressure =-127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9 -inch o.c. at the 44nch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #49 Maximum Design Pressure= -127.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 94nch o.c. at the 4inch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows. Undedayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt. #50 Maximum Design Pressure =-127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9 -inch o.c. at the 4 -inch wide side laps and 9 -inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. 5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table SA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Maximum Exposure (days) Elastoflex G TU, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU 180 Max, Polystick TU P or Polystick TU Plus Polystick IR -Xe or Polystick MU -X 90 Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base 30 180 (for adhesive -set tile) Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR UNLIMITED (for mechanically fastened roof prepared roof covers) 5.8 Polystick MU -X has been found through comparative testing to have a lesser coefficient Of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. NEMO ETC, LLC. Evaluation Report P12060.02.09 -R25 Cern/ic#te ofAuthwization#32455 691 EDITION 120171 FBC NON-HVHZ EVALUATION FL5259-RZ9 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 13 of 16 ONEMOletc. 5.9 Tile Sliooaae Limitations (FRSA/TRI Aoril 2012 (04-121): When loading roof tiles on the underiayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Luse: 6.3.1 Non -Tile Aoolications Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule - Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Aoolications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April 2012 (0412) Installation Manual. NEMO ETC, LLC. Evaluation Report P12060.02.09-1125 Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5299-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 14 of 16 TABLE 2: TILE SUPPAGE LIMfTATIONs FOR DIRER -DECK TILE INSTALLATIONS Underlaymem Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10 -tile stack 7:12 Lugged 8 -tile stack (6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6 -tile stack (4 over 2) 4:12 HydraGuard Tile Pro Flat or Lugged 6 -tile stack (4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6 -tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6 -tile stack (4 over 2) 4:12 Polystick MTS Plus Flat 6 -tile stack (4 over 2) 5:12 Lugged 6 -tile stack (4 over 2) 4:12 Polystick TU Max Flat 6 -tile stack (4 over 2) or 10 -tile stack 7:12 Lugged 6 -tile stack (4 over 2) 7:12 Lugged 10 -tile stack 6:12 Polystick TU P Flat 6 -tile stack (4 over 2) 6:12 Lugged 6 -tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-uie stack (4 over 2) 7:12 Flat or Lugged SD -tile stack 6:12 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Luse: 6.3.1 Non -Tile Aoolications Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule - Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Aoolications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April 2012 (0412) Installation Manual. NEMO ETC, LLC. Evaluation Report P12060.02.09-1125 Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5299-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 14 of 16 ON EMO etc. 6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA -APP Cap Sheet, Mule -Hide SA -APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick IR -Xe, Polystick MTS Plus, Polystick MU -X, Polystick TU Max, Polystick TU P or Polystick TU Plus: 6.4.1 6.4.2 6.4.3 6.4.4 General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Vkm of Ovelep Seam of HydraGwrd Dual Pro and HydraGuard Tile Pro Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. rile Applications (excludes HydraGuard Dual Pro, Polystick IR -Xe and Polystick MU -X): Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI April 2012 (04-12) and Polyglass published requirements. For mechanically fastened tile roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04.12), Table 1. For adhesive -set tile applications, refer to Section 5.6.1 herein. Multi -Ply Underlavment Systems: Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU -X, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2 -ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2 -ply underlayment system is desired. 6.5 I Elastoflex G TU, Elastoflex 56 6 or Elastaflex 56 6 FR: 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" In the'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (0412) beneath mechanically fastened tile roof systems. NEMO ETC, LLC. Evaluation Report P12060.02.09-RZ5 Certificate of AuthonzWon #32455 6'"EDITION (2017)FOC NON-HVHZ EVALUATION FL5259.R29 Polyglass Roof Undedaymems, (954) 233.1230 Revision 25:10/14/2019 Page 15 of 16 . .. F ONEMO I etc. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Table 2. Side laps shall be minimum 3 -Inch and end -laps minimum 6 -inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8 -Inch beyond the lap edge. 6.6 Polyflex G or Polyllex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet' In the 'Two Ply System" from FRSA/TRI April 2012 (04- 12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options). 6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3 -inch and end -laps minimum 6 -inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8 -inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA(TRI April 2012 (0412) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C. 61620-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. 9. QUALITY ASSURANCE ENmr. UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC. Evaluation Report P12060.02.09-1125 Certffimte of Authorization#32455 6T" EDITION (2017) FEE NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 16 of 16