Loading...
HomeMy WebLinkAboutTrussR 0 F a' R E, 4451 ST. L-UCIE BLVD FORT PIERCE, FL 34946 PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com TRUSS ENGINEERING BUILDER: RENAR PROJECT. COUNTY: MORNINGSIDE ST LUCIE m m j� �_ LOT/BLK/MODEL: LOT:40 / MODEL:BERMUDA9-4�EEV:B/ GAR R 0 �m n o JOB#: 78706 n ® r o rn c 5 ® 3 MASTER#: WRMSBM1674BG � o m OPTIONS: EXTENDED GAR A-1 ROOF TRUSSES AFLOR OACORPORATTON RE: Job WRMSBM1674BG Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. Site Information: Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot%Block: Model: BERMUDA 1674 Address: MORNINGSIDE, FORT PIERCE Subdivision: City: County: St Lucie A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946 State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 37.0 psf Floor Load: 0.0 psf This package includes 30 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this Index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 2564 A01 215/20 13 2576 A14 215/20 25 2677 J3 2/5/20 2 2558 A02 2/5120 14 2614 A15 215/20 26 2701 J3A 2l5/20 3 2543 A03 215/20 15 2594 B01 215120 27 2527 J3GE 2/5/20 4 2629 A04 215120 16 2591 B02 215120 28 2680 J5 2/5/20 5 2617 A06 2/5/20 17 2608 B03 2J5120 29 2692 J7 215/20 6 2626 A07 2I5120 18 2601 C01 215/20 30 2689 J7C 215/20 7 2526 A08 215120 19 2605 CO2 215120 31 STDL01 STD. DETAIL 215/20 8 2623 A09 2/5120 20 2521 CJ1A 215120 32 STDL02 STD. DETAIL 215/20 9 2632 A10 215120 21 2523 CJ3A 2/5/20 33 STDL03 STD. DETAIL 2/5/20 10 2470 All 215/20 22 2707 HJ7S 215/20 34 STDL04 STD. DETAIL 215120 11 2513 Al2 2/5120 23 2683 A 215/20 35 STDL05 STD. DE 1215120 12 12710 1 A13 2/5/20 1 24 12674 Jt 12/5/2LJ 136 1 STDL06 STD. DETAIL 2/5120 The truss drawing(s)referenced have been prepared hyAlpine Engineered Products, Inc. undermydirectsupervlsion based on the parameters provided byA-1 Roof Trusses, Ltd. Truss Design Engineers Name: Manuel Martinez My license renewal date forthe state of Florida is February 28,2021. NOTE:Thesea] on these drawings Indicate acceptance of professional engineering responsibility soleyforthe truss components shown. The suitability and use of components forany particular building Is the responsibility of the building designer, perANSyr13I.1 Sec.2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also mfened to at times w'Soucturel Engineering Documents) provided by the Building Designerindirating the nature and characterof the work The design criteria therein have been bansfened to Manuel Martinez PE by [At Roof Trusses orspeci8c location]. These TDDs (also referred to attunes as'Stmatural Delegated' Englneedng Documents) are specialty structural component designs and maybe part of the projects defend orphaned submittals. As aTniss Design Engineer(I.e., Specialty Engineer), the seat here and on the Too represents an acceptance of professional engineering nsponsibirnyforthe design of the single Truss depicted on the Too only. The Building Designeris responsible forand shall coordinate and review the TDDs for compatibility with thelrwritten engineering requirements. Please review allTDDs and all related notes. Manuel01g1�'"Sgnetlt MMarti anuel nez n Date:2020.02.05 Martine,�r r" -05oo 1 Ho 04T502 *? ;t- t O R� SOUL Manuel Martinez, P.E. 4620 PadcYiew Dc St Cloud,FL34771 s ALO Page 1 of 2 (Zt. L_(e_ A-1 ROOF TRUSSES A FLORIDA CORPORATION RE: Job WRMSBM1674BG No. Seq # Truss Name Date 37 STDL07 STD. DETAIL 2/5/20 38 STDL08 STD. DETAIL 2/5/20 39 STDL09 STD. DETAIL 215/20 40 STDL10 STD. DETAIL 215/20 41 STDL11 STD. DETAIL 215120 42 STDL12 STD. DETAIL 215/20 43 STDL13 STD. DETAIL 215120 44 STDL14 STD. DETAIL 2/5/20 45 STDL15 STD. DETAIL 2/5120 46 STDL16 STD. DETAIL 215/20 Lumber design values are in accordance with ANSIIfPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. Page 2 of 2 Job 1674BG Truss Truss Type A01 I COMN Cry I Ply 102/0512020 2564 T T �e �L f 1P6.6 14'3.4 Ies SEAT PLATE SEATggJERMATPt TEREMATF. TEREQ. SE TPLATE REQ 11'43 47�i 11CC�4 6'4- 1/�� 1918.3 I 9'0.6 i 2'6.14 i 38' Loading Criteria (psrl Wind Criteria Code I Misc Criteria TCLL: 20.00 Wind Sld: ASCE 7-10 Code: FSC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) EXP: B Kzb NA Plate Type(s): Des Ld: 37.00 Mean Height: 15.00 it WAVE NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 MWFRS Parallel Dist: h2 to h C&C Dist a: 3.80 It Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T1 2x6 SP #2: :T2 2x4 SP M-30: Bot chord 2x4 SP #2 Webs 2x4 SP #3 :W3 2x4 SP #2: Bracing (a) Continuous lateral restraint equally spaced on member Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chard Spacing(in oc) Start(ft) End(ft) TIC 24 8.16 22.43 BC 75 0.15 15.91 BC 120 15.98 35.48 Apply pudins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. -WARNING - De81CSl Criteria PP Deflection in loc Udell L/# VERT(LL): 0.192 U 696 361 VERT(CL): 0.390 U 342 241 HORZ(LL): 0.131 U - - HORZ(TL): 0.260 U - - Creep Factor: 2.0 Max TC CSI: 0.825 Max BC CSI: 0.778 Max Web CSI: 0.787 Wgt: 201.6 Ibs VIEW Ver. 19.01.00A.0618.15 and 19'11.4 ♦ Maximum Reactions (Ibs), or `=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL A 264 /- /- /147 /104 /192 R 1151 /- /- /698 1542 /- P• 136 /- /- /58 1- /- N 651 /-144 1- 1267 /166 /- 1 828 /- I- /585 1260 !- Wind reactions based on MWFRS A Brg Width = 7.6 Min Req = 1.5 R Brg Width = 7.6 Min Req = 1.5 P Brg Width = 76.0 Min Req = - N Brg Width = 7.6 Min Req = 1.5 1 Brg Width = 7.6 Min Req = 1.5 Bearings A, R, P, N, & I are a rigid surface. Bearings A, R, P, N, & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 196 -229 F-G 496 -562 B - C 582 -258 G - H 480 -632 C - D 428 -165 H -1 644 -1200 D-E 383 -119 I-J 35 0 E-F 382 -119 Maximum Sot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - T 358 -403 N - M 469 -138 U-R 0 -56 M-L 469 -138 T-S 376 -374 L-K 1000 -460 S - Q 381 -377 K -1 1002 -459 P-O 785 -987 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp U-T 24 0 E-O 311 -454 C-S 201 -145 O-N 422 -133 P-Q 737 -998 N-F 214 -679 P-D 479 -960 F-L 448 -123 Q-R 858-1116 L-H 369 -609 D- O 503 -433 H- K 226 0 tam. nd breGng shall be Pe responsibility a rue BuIlding Designer and Conbaaer. All notes set out In me TDD and Ue pm0iws end =II Wbilshed by TPl and SBCA are referenced for general guWanm. TP idefines Meresponslbllitesmdddwerue Truss ass oNemise defined by a Contract named upon in wnfng by all padies imohed. The SpeCalty Engineer is NOT rue All capitalized tarts are as defined In TPI-1. N. N nmfmm. k ortYJNIM WtMdtlwwiMn m,m4sm MM1 RW TnaW.e. Job Truss WRMSBM1674BG A02 Truss Type COMN —}10'5'4 — a6X6 I111.5X3 City I Ply 102/O5/2020 N1.5X3 sx4X10sa3X6 111.5X3 r 2553 SEAT FLATS RED. SEAT PLATE RED. 38' —2'4'—r 1&0'2 -f 197'94 Loading Criteria (p ri Wind Criteria Code / Misc Criteria Deg/CSI Criteria • Maximum Reactions (Ibs) TCLL: 20.00 Wind Sid: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L#1 Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): 0.285 Q 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.541 Q 832 240 A 1456 /- !- /758 l373 /219 BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.193 K - - 1 1524 /- /- /897 /382 /- EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.367 K - - Wind reactions based on MWFRS Des Ld: 37.00 Mean Height: 15.00 ft WAVE Creep A B Width 7.6 Min Re 1.5 re q NCBCLL: 10.00 TCDL: 4.2 sf P Max TC CSI: 0.784 CSI::20. I Big Width = 7.6 Min Req = 1.8 Load Duration: 1.25 BCDL: 4.2 sf P 988 Max BC CSI: 0.744 Bearings A & I are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h/2 to It Bearings A & I require a seat plate. C&C a: ft Max Web CSI: 0.744 Maximum Top Chord Forces Per Ply (Ibs) from Loc. from endwall: not in 9.00 dwa Wgt: 259.0 lbs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A-B 406 -640 F-G 1015 -1982 Lumber B - C 1435 -3210 G - H 991 -2020 C - D 1237 -2654 H -1 1161 -2644 Top chord 2x4 SP #2 :T1 2x6 SP 24001-2.0E: D - E 1319 -2646 I - J 35 0 Bat chard 2x4 SP #2 :B1 2x4 SP M-30: E - F 1316 -2639 Webs 2x4 SP #3 Bracing Maximum Bat Chord Forces Per Ply (Ibs) (a) Continuous lateral restraint equally spaced on member. Chords Tens.Comp. Chards Tens. Comp. Trey Scabs) B-Q 3019-1120 M-L 2272 -903 Q-P 2299 -729 L-K 2272 -903 (2) 2x6x10-11.1 x SP 24001-2.0E scabs at left end. Attach one scab to each outer P - N 2300 -729 K - I 2274 -902 face of chord with: 0.131"x3", min. nails @ 8" oc, Plus additional nall clusters at: O - M 15 -5 BRG.: (4), heel: (5), tat panel point: (2). Purling Maximum Web Forces Per Ply (Ibs) In lieu of structural panels or rigid calling use purilns Webs Tens.Comp. Webs Tens. Comp. to laterally brace chords as follows: C - Q 527 -909 N - M 1953 -665 Chord Spacing(in oc) Start(ft) End(ft) D - Q 599 -191 N - F 1441 -510 TC 24 10.12 BC 1.1 16.16 D - N 450 -233 M - F 206 -578 BC 16.16 35..52 95 E - N 213 -286 M - H 370 -649 Apply purling to any chords above or below fillers N - O 47 0 H - K 268 0 at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. —WARNING- Please thoroughly review Me -A-1 ROOF TRUSSES ('SELLER'). GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER') ACKNOWLEDGMENT'faml. Verify design parameters and reed notes on this Truss Design Drawn, (TDD) and Me Spetlelty Engineer reform. sheet before use. Unless othervAse stated on Malmo, only Alpine a connector plates shell be used for the TDD to be valid. As a Tmss Design Engineering (i.e. Speclalty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responslbllM for tiro design of the single Truss depicted an the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss forany Buffing a the responsiblily of the Owner, the Owner's eutho,rsed agent orthe Bu ding Designer, in Me cbntetlnf the IRC, Me IBC, local building code and TPI-1. The aWrorel of the TDD and any field use of Me Truss, Including handling, storage, Installation and bredng shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the pactices and guiddinwofthe Budding Component SaletylMm tm(BSCI)WWIshedby TPIaMSBCAarerefere fwgenemlguidaiwa. TPI-ldefinesdamMnsiblkb"mddutiesof Ne Truss Designer, Specialty Engineer and Truss Manufacturer, unless aNervnse defined by a Contract agreed upon in writing by all p riles Involved. The SpeciallyEnginew is NOT the B h1lhgDeslgnerwTmss System Enginearefanylawldh,g. Alcapltellredlennsaremilefinedin TPI-1. fiu,MaMO4111a A.faMTn,wa�aavM,vfimNlNahnumJ.lnnnvlmm_koMtiMMwXMeXwwlXnn mmlrwm NM1RMTn,xw. Job Truss Truss Type Dry Ply 02/05r2020 `�NRMSBM1674BG I A03 I COMN 11 11 2543 01.5X3 =7X8 IUX4 =7X8 os3X6 111.5X3 SEAT PLATE RED. 38, il4—f1 Loading Criteria(psp Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Load Duraflon: 1.25 BCDL: 4.2 psf Spacing: 24.0 ° MWFRS Parallel Dist: h/2 to It C&C Dist a: 3.80 ft Loc. from endwall: not in 9.00 GCpI: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2:T5 2x4 SP M-30: Bot chord 2x4 SP #2 Webs 2x4 SP #3 :W9 2x4 SP #2: SEAT PLATE RED. Code I Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udell L/# Gravity Non-Gravily TPI Std: 2014 VERT(LL): 0.262 G 999 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.495 G 915 240 B 1530 /- /- /868 1379 /269 FT/RT:10(0)/10(10) HORZ(LL): 0.160 M - - K 1530 /- /- /906 /381 (- Plate Type(s): HORZ(TL): 0.302 M - - Wind reacUons based on MWFRS WAVE, HS Creep Factor: 2.0 B Brg Width = 7.6 Min Req = 1.8 Max TC CSI: 0.834 K Brg Width = 7.6 Min Req = 1.8 Max BC CSI: 0.993 Beatings B 8 K are a rigid surface. Bearings B 8 K require a seat plate. Max Web CSI: 0.938 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 232.4 lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A- B 35 0 G - H 1208 .2516 B - C 1152 -2720 H -1 941 -1879 C - D 1439 -3433 I - J 909 -1894 D-E 1445-3338 J-K 1117 -26N E-F 1197-2608 K-L 35 0 F - G 1210 -2524 Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use puffins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 14.45 20.89 BC 103 0.15 10.89 BC 91 10.91 18.49 BC 94 18.49 37.85 Apply putting to any chords above or below fillers at 24° OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords. Tens. Comp. B-U 2360 -828 Q-O 18 -6 U-T 40 -13 O-N 2253 -856 S - R 3009 -972 N - M 2253 -856 R - P 2294 -648 M - K 2255 -855 Please thoroughly review the -A-1 ROOF TRUSSES ('SELLER'), GENERAL TERMS and CONDRIONS CUSTOMER Aers raw and mad notes on this Truss Design Ding (TDD) and the Specialty Engineer reference sheet before use. Unless othi II be used for the TDD to be valid. As a Truss Design Engineering Q.e. Specialty Engineer), the seal on any TDD represent design of the single Truss depicted on the TDD oNy, under TPI-1.Tho design assumptions, loading conditions, suitabiiby an, Xoner, the Owmets autlgrized agent or the Ending Designer, in the context of the IRC, the IBC. Insult building code and TPI. uding handing, storage, installation and leasing shall be the reeponvbili y oldie Building Designer and Contractor. Minutes Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-U 365 -820 G-P 75 -80 C-S 684 -153 P-Q 0 -34 U - S 2463 -864 P - O 2703 -824 S-T 71 0 P-H 2354 -683 S - E 897 -290 O.- H 538 -1760 E - R 500 -1071 O - J 424 -762 F-R 579 -248 J-M 307 0 F-P 391 -179 and Job Truss Tmss Type Qty Ply 02/05/2020 WRMSBM1674BG A04 Ci I I1 I 2629 T. l REQ. Loading Criteria (pan Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00It NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.80 It Loc. from endwall: not in 9.00 GCpI: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T5 2x4 SP M-30 Bat chord 2x4 SP #2 Webs 2x4 SP #3 li -S a Xli 101.SX3 SEAT PLATE REQ. 197"14 Code I Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udell L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.156 R 999 360 Loc R+ / R- I Rh / Rw I U / RL Rep Factors Used: Yes VERT(CL): 0.293 R 999 240 B 1527 /- /- /851 /441 /304 FT/RT:10(0)/10(10) HORZ(LL): 0.072 M - - K 1529 /- !- /889 /444 /- Plate Type(s): HORZ(TL): 0.136 M - - Wind reactions based on MWFRS WAVE Creep Factor. 2.0 B Big Width = 7.6 Min Req = 1.8 Max TC CSI: 0.841 K Erg Width = 7.6 Min Req = 1.8 Max BC CSI: 0.859 Bearings B & K are a rigid surface. Max Web CSI: 0.723 Bearings B & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 221.2 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A-B 35 0 G-H 914 -1925 B - C 1088 -2646 H - I 998 -2153 C-D 879-1947 I-J 9a2 -2163 D-E 908-1917 J-K 1074 -26N E- F 884 -1651 K- L 35 0 F - G 889 -1660 Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes (")1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purling In lieu of structural panels use puffins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. resign Drawng CMD) and Me Specially Engineer reference sheet Wand use. Unless oMeWw slated on is a Truss Design Engineedog (i.e. apecially Engineer), Ne seal on any TOO represents an acceptance c on the TDD only, under TPI4. The design assumpGans, loading cendidons, sullaWlity and use of Ws Tnu uor Ne guiding Designer, in Me coate,acfthe IRG the IBC, local building We end TPI-1. Theappmw and b2rinashall be the reslnnsibgiN at Me Buildina Dmianerand Conbactar. Allnolessetoulintbe'r Maximum Bat Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B-T 2275 -773 Q-O 36 -8 T-S 2273 -773 O-N 36 -8 S - R 2273 -773 N - M 2254 -833 R - P 1637 -452 M - K 2255 -833 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp T-C 292 -5 P-H 233 -300 C-R 385 -721 P-N 1899 -659 E-R 400 -146 H-N 150 -93 E - P 203 -190 N - J 249 -495 F-P 683 -361 J-M 219 -11 P-Q 100 -1 Job Truss Truss Type A07 ICOMN Qiy, Ply 1 I, 02/05/2020 2626 i 775 + Tril{— Loading Criteria s,q Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BOLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 it NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 ° MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.80 it Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Top chord 2x4 SP #2 :T1, T2 2x6 SP 2400f-2.OE: Bot chord 2x4 SP #2 :Bi 2x4 SP M30: Webs 2x4 SP 43 Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(OU10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Purllns In lieu of structural panels use pudins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes (2) 2x6x8-0-0 x SP 2400f-2.OE Top chord scabs centered 4-2-14 from left end. Attach one to each outer face of chord with (3) rows of 0.131 "x3", min. nails @ 12" oc, staggered 6". "WARNING" Please thoroughly review the -A-1 Vorify design pammetem and need notes on this Truss D, @5X6 a5m G H 3I,5X4 e6x8 sa3X6 a1.5X3 RED. 2' _( i 19'3'8 14� 9T Deg/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defi L/# Gravity Non -Gravity VERT(LL): 0.385 D 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.731 D 621 240 A 1444 /- /- 1773 /407 1287 HORZ(LL): 0.251 N - - L 1537 A /- 1891 /446 /- HORZ(TL): 0.476 N - - Wind reactions based on MWFRS Creep Factor. 2.0 A Brg Width = 7.6 Min Req = 1.5 Max TC CSI: 0.477 L Brg Width = 7.6 Min Req = 1.8 Max BC CSI: 0.702 Bearings A 8 L are arigid surface. Max Web CSI: 0.815 Bearings A & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 289.1 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.15 A-B 347 -633 G-H 964 -1915 B - C 363 -614 H -1 949 -1988 C - D 1668 -4000 I - J 1006 -2171 D - E 1283 -3002 J - K 991 -2240 E-F 1294-2955 K-L 1112 -2713 F-G 1026-2210 L-M 35 0 on Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp C-W 3860-1440 R-P 28 -9 W - V 3857 -1441 P - O 2346 -891 V - T 2559 -857 O - N 2346 -891 U-Q 18 -8 N-L 2348 -891 S-R 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp W-D 121 -1 Q-R ill -1 D-V 627-1391 Q-H 178 -183 V - F 591 -235 Q -1 232 - 304 F-T 400 -809 Q-P 1955 -695 G - T 699 -339 I - P 112 -100 T - U 42 -1 P - K 242 -479 T-Q 1819 -541 K-N 198 -3 T-H 649 -207 by a RonfTnicws. and Job Truss Truss Type Qty Ply 02/05/2020 2526 WRMSBM1674BG I A08 I COMN 11 1 I 1 T 1 V i 14.4• 6'8• 1r REQ. F2'4'8 -{- 13.1 %5X6(R) a3X4 -SX8 E F G Loading Criteria (psll Wind Criteria Code / Mist: Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: ll FT/RT:10(0v10(10) EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 25.00 it WAVE NCBCLL: 10.00 TCDL: 4.2 psi Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to It C&C Dist a: 3.80 It Loc. from endwall: not in 9.00 GCpl: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T1 2x6 SP 24001-2.0E: :T2 2x6 SP #2: :T5 2x4 SP M.30: Bot chord 2x4 SP #2:B1 2x4 SP M-30: Webs 2x4 SP #3 Filler 2x4 SP #2 Bracing (a) Continuous lateral restraint equally spaced on member. Tray Scab(s) (2) 2x6xl1-0-14 x SP 2400f-2.OE scabs at left end. Attach one scab to each outer face of chord with: 0.131"x3', min. nalls @ 8" oc, Plus additional nail clusters at: BRG.: (4), heel: (5), 1st panel point: (2). Purlins In lieu of structural panels or rigid ceiling use puffins to laterally brace chords as follows: Chord Spacing(In oc) Start($) End(fl) TC 24 11.96 18.63 BC 110 0.15 16.06 BC 87 16.11 35.48 Apply purling to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. 2x4 e6x8 a3x6111.5x3 DeflICSI Criteria PP Deflection in loc Udell L/# VERT(LL): 0.285 R 999 36 VERT(CL): 0.540 R 833 24 HORZ(LL): 0.211 L - - HORZ(TL): 0.400 L - - Creep Factor. 2.0 Max TC CSI: 0.644 Max BC CSI: 0.984 Max Web CSI: 0.916 Wgt: 273.7 Ibs VIEW Ver. 19.01.00A.0618.15 view the -A-1 ROOF TRUSSES ("SELLER'), GENERALTERMS and CONDITIONS CUSTOMER ('BL i this Tress Design Onowng (Too) and Me Specialty Engineer reference sheat before use. Unless othernis to be valid. As a Truss Design Engineering i1 e. Specialty Engineer), the seal on any TDD represents an ai ins depicted on the TOO only, under TPI-1, The design assumptions, loading condition, suitability and use horned agent orthe Building Designer, In the coned of the IRO, the IBC, local building code and TPI-1. T s. installation and bmcino shall be the resoonsibiliN of the Buildino Designer and Contractor. All notes set, I 1 SEATPLATEREe. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U I RL A 1456 /- /- /746 /434 I260 J 1524 /- /- /888 /446 /- Wind reactions based on MWFRS A Big Width =7.6 Min Req=1.5 J Brg Width =7.6 Min Req=1.8 Bearings A & J are a rigid surface. Bearings A & J require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 402 -640 F-G 1140 -2240 B - C 1349 -3154 G - H 949 -1773 C-D 1103-2377 H-1 932 -1890 D-E 1124-2366 1-J 1127 -2620 E- F 1058 -2049 J- K 35 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - S 2966 -1041 P - N 46 -16 S - R 2963 -1041 N - M 2246 -866 R - Q 2240 -686 M - L 2246 -866 Q-0 2198 -670 L-J 2249 -864 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp S-C 167 0 O-U 12 -24 C - R 528 -1059 O - N 2231 -694 E-R 710 -279 O-G 1714 -509 R-F 160 -366 U-P 0 -24 T-Q 50 0 N-G 370 -1179 T - U 47 -17 N -1 423 -759 F-O 249 -103 I-L 305 0 NA-1 Rnn Tn-. Job Truss 'WRMS8M1674BG A09 L r Truss Type COMN —� 10'8' — E6X6 111.5X3 e4X4 D E F Qty, I Ply 1 1 c6X6 G 02/05/2020 I11.5X3 m4X10 m3X6 111.5X3 2623 SEAT PLATE REQ. SEAT PLATE RED. 38' Loading Criteria (psp Wind Criteria Code I Misc Criteria TCLL: 20.00 Wind Still: ASCE 7.10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(1(1) EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 4.2 psi Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 ° MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.80 ft Loc. from endwall: not In 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :Ti 2x6 SP 2400f-2.OE: Bot chord 2x4 SP #2 :Bt 2x4 SP M-30: Webs 2x4 SP #3 Bracing (a) Continuous lateral restraint equally spaced on member Tray Scab(s) (2) 2x6x9-9-8 x SP 24001-2.0E scabs at left end. Attach one scab to each outer face of chord with: 0.131"x3", min. nails @ 8" oc, Plus additional nail clusters at: BRG.: (4), heel: (5), tat panel paint: (2). Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. DeflICSI Criteria PP Deflection in loc, L/defl L/# VERT(LL): 0.283 E 999 36( VERT(CL): 0.538 E 837 24( HORZ(LL): 0.185 L - - HORZ(TL): 0.351 L - - Creep Factor: 2.0 Max TC CSI: 0.693 Max BC CSI: 0.761 Max Web CSI: 0.971 Will: 266.0 lbs VIEW Ver. 19.01.00A.0618.15 t 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- ! Rh / Rw / U / RL A 1456 /- /- f777 1413 /230 J 1524 /- /- /884 /446 /- Wind reactions based on MWFRS A Brg Width = 7.6 Min Req = 1.5 J Brg Width = 7.6 Min Req = 1.8 Bearings A 8 J are a rigid surface. Bearings A 8 J require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chards Tens.Comp. Chords Tens. Camp. A-B 384 -640 F-G 1133 -2208 B - C 1507 -3417 G - H 994 -2007 C-D 1222-2W8 H-1 968 -2034 D - E 1277 -2606 I - J 1162 -2657 E- F 1272 -2596 J- K 35 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - S 3253 -1250 N - M 2287 -929 S - Q 2301 -784 M - L 2287 -929 R-O 50 -17 L-J 2289 -929 P-N 22 -8 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - S 550 -1079 F - O 444 -1165 D-S 534 -202 O-P 49 0 D-Q 477 -239 O-N 1791 -650 E-Q 115 -129 O-G 813 -314 Q-R 33 0 N-G 111 -173 Q-F 1051 -378 N-1 346 -642 Q-O 2456 -893 I-L 254 -4 Ne th. M MA-1 Rm Tnic-nx. All Ixe ofMo Tmss Job Truss Truss Type Illy I Ply 02/05/2020 WRMSBM1674BG A10 I HIPS 1 1 2642 i- 10'4" { 14'8" 13' 95X8 111.SX3 D E IF 12 6 F,;- ak3X6 m �1.5X3C GN@3X4 o_ D 2—3X6A(A1)8=5X8 1 ' 81 6a� N =3X8(A1) O M L K N 1.5X4 ee6X8 =3X6 W1.5X3 SEAT PLATE REQ. 1-4"} 18'4" 'fI gig" Loading Criteria gaq Wind Criteria TCLL: 20.00 Wind Sld: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 'TCDL: 4.2 pest Load Duration: 1.25 BCDL: 4.2 pest Spacing: 24.0 " MWFRS Parallel Dist: h/2 to IT C&C Dist a: 3.80 it Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2:T2 2x4 SP M-30: Bot chord 2x4 SP #2 :Bi 2x4 SP M-30: Webs2x4 SP #3 Code I Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT;10(0u10(10) Plate Type(s): WAVE Purling In lieu of structural panels use pudins to brace all flat TC Q 24" Do. Wind Wind loads based on MWFRS with additional C&C member design. "WARNING" SEAT PLATE REQ. I 1 DeB/CSI Criteria ♦ Maximum. Reactions (Ibs) PP Deflection in loc Udell L/# Gravity Non -Gravity VERT(LL): 0.199 E 999 360 Loc R+ I R- I Rh / Rw / U I RL VERT(CL): 0.376 E 999 240 B 1530 A A /850 /382 1203 HORZ(LL): 0.076 K - - I 1530 I- I- /889 /364 A HORZ(TL): 0.143 K - - Wind reactions based on MWFRS Creep Factor. 2.0 B Big Width = 7.6 Min Req = 1.8 Max TC CSI: 0.526 I Big Width = 7.6 Min Req = 1.8 Max BC CSI: 0.790 Bearings B & I are a rigid surface. Max Web CSI: 0.722 Bearings B & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 207.2 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A-B 35 0 F-G 1061 -2173 B - C 1249 -2730 G - H 1039 -2192 C - D 1131 .2418 H -1 1199 -2699 D- E 1347 -2723 I- J 35 0 E - F 1344 -2715 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B-0 2380 -951 M-L 2333 -971 Q-P 2106 -747 L-K 2333 -971 P - N 2108 -747 K - I 2335 -971 O-M 35 -14 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-0 225 -301 N-M 1894 -719 D-Q 378 -76 N-F 1057 -442 D-N 726 -351 M-F 120 -76 E-N 268 -482 M-H 292 -516 N-O 90 0 H-K 208 0 s depleted on Me TOD oNy, under TPI-1. no design assumptions, loading contlNons, swtabllity and use ni ed agent or We Bulidiig Designer, In Ne canted dike IRC, Me IBC, IOW building rode and TPI-1. T Inslalldlon and braded slall be We resconsibiEw of�e Bul ino OesioneraM Conaador. Ninalessett n—n dA-1 RerdT—. Job Truss Truss Type City Ply A13 HIPS I 1 I 1 02/05/2020 2710 280 1874 187N+ Im IM Vice 190IX 438p F--43.18 Y4- ZtY Y=-A=Y-}Y-ry--Y Z Y �8 TB•6� 1­--4'3.4 'I' 28'8• -I T� 12 8 a1.5X3 m4X8 H 87X8(R) T 1 SFATftATE REO. SEATRAIERFA. SfPTPIATERFA 1371 } 24'e'3 i 1117E i 114 i 1117E i98# i su i sd i gtle1 i 213IX 111IX 111# 98M am 98# 9efl bow Loading Criteria(Psq Wind Criteria TCLL: 20.00 Wind Sld: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category. II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 It NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 ° MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.79 It Loc. from endwall: not In 4.50 GCpi: 0.18 Wind Duration: 1.60 Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Varies by Ld F77RT:10(Ou10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection In Joe L/defl L/# VERT(LL): 0.244 R 999 361 ITtRT(CL): 0.454 R 648 241 HORZ(LL): 0.067 N - - HORZ(TL): 0.124 N - - Creep Factor. 2.0 Max TC CSI: 0.963 Max BC CSI: 0.857 Max Web CSI: 0.740 Wgt: 232.4 IDS VIEW Ver. 19.01.00A.0618.15 Lumber Wind Top chord 2x4 SP #2 :T2, T3 2x4 SP M-30: Wind loads and reactions based on MWFRS. Bot chord 2x4 SP M-30 :Bi 2x4 SP #2: Left bottom chord exposed to wind. Webs 2x4 SP #3 :W7, W 12 2x4 SP #2: :W8 2x4 SP M-30: Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads -(Lumber Dur.Fac=1.25 / Plate Dur.Fac =1.25) TC: From 62 plf at -1.40 to 62 pif at 4.27 TC: From 31 pif at 4.27 to 31 pif at 30.94 TC: From 62 pif at 30.94 to 62 plf at 39.27 BC: From 14 plf at 0.00 to 14 plf at 4.30 BC: From 7 plf at 4.30 to 7 plf at 30.65 BC: From 14 pif at 30.65 to 14 plf at 37.94 TC: 284lb Cone. Load at 4.30 TC: 187 lb Cone. Load at 6.33, 8.33,10.33,12.33 14.33 TC: 190 lb Cone. Load at 16.33,17.60,18.87,20.87 22.87,24.87,26.87,28.87 TC: 436 lb Conc. Load at 30.91 BC: 213 lb Conc. Load at 4.30 BC: 111 lb Conc. Load at 6.33, 8.33,10.33,12.33 14.33 BC: 98 lb Conc. Load at 16.33,17.60,18.87,20.87 22.87,24.87,26.87,28.87 BC: 605 Ib Conc. Load at 30.91 Plating Notes All plates are 3X4 except as noted. Purling In lieu of structural panels use purling to brace all flat TC @ 24° oc. '•WARNING'• Please thoroughly review the-A-1ROOF TRUSSES('SELLEW), GENERAL TERMS and 'gdfy design parameters and read notes on this Truss Design Drawing (iDD) and the Specialty Engineer reference .nnedor Dial.. shall be ..ad far Me TDD to be valid As a Truss Desl.n Enalneerin. It Snndallv Fnainanrl. the 7'3.8�14 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL AC 538 1- l- 1- 1218 A Z 4904 1- 1- 1- /2390 1- L 2010 A /- /- /789 /- Wind reactions based on MWFRS AC Big Width = 6.9 Min Req = 1.5 Z Brg Width = 7.6 Min Req = 5.8 L Brg Width = 7.6 Min Req = 2.4 Bearings AC, Z, 8 L are a rigid surface. Bearings AC, Z, 8 L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 37 -17 G-H 406 -862 B - C 227 -486 H -1 1534 -3466 C- D 723 -168 I-J 2017 -4675 D - E 3511 -1565 J - K 2172 -5244 E - F 405 -862 K - L 1480 .3722 F-G 406 -862 L-M 35 -16 Maximum Bat Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp AC -AB 6 0 U - T 3356 -1497 AS -AA 387 -183 T - S 3356 -1497 AA-Z 153 -331 S-R 4656 -2024 Z-X 35 -81 R-O 4781 -1973 Y- W 1482 -3334 O- P 0 0 X-V 0 0 P-N 106 -47 W-U 1516-3413 N-L 3263 -1294 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B-AC 240 -522 F-U 419 -647 B -AB 402 -194 U - H 1274 -2919 C -AB 292 -16 H - S 975 -320 C -AA 444 -1146 S -1 578 -1408 AA-D 1037 -398 I-R 161 0 AA-Y 32 -453 R-J 91 -123 D - Y 1580 -3278 O - P 640 -166 Y-Z 2213-4514 0-J 1632 -530 Y - E 1522 -3149 O - N 3278 -1293 E - U 4968 -2244 O - K 1455 -662 W-X 38 -84 N-K 474 -1050 form. n,MlNtn,l WlnnntlwwXMnm,mlulnndMl RmfTnrw TP11 defire.5et nd in the TDD antl Ne pradiras antl TPI-1 defines the salty Engineer and dudes of Ne Truss evolved. The S9eaelry Engineer is NOT the Job Truss Truss Type Qty, Ply 02/05/2020 . 25-a WRMSBM1674BG IA14 ICOMN I1 I1 11 �I b T " V L i 81616 i 4'8'^-9•10{ 9" '1 10'2• 1TTIS SEAT PLATE RED. SEAT PLATE REQ SEAT PLATE RED. SEAT 1^11'43 i- 611.10 i 19'8'3 Loading Criteria (psi Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: It EXP: B Kzb NA Des Ld: 37.00 Mean Height: 15.00 it NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.80 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :T1 2x6 SP #2: Bot chord 2x4 SP #2 35 2x4 SP M-30 Webs 2x4 SP #3 Plating Notes All plates are 1.5X3 except as noted. Code I Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0Y10(10) Plate Type(s): WAVE Purling In lieu of structural panels use puriins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS vnth additional C&C member design. Additional Notes Lanai/Porch Loading : 6.9 PLF wind pressure applied to the bottom chord of the truss from 11.67 ft to 18.33 ft, 38' Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L#t Gravity Non -Gravity VERT(LL): 0.064 X 999 360 Loc R+ / R- I Rh / Rw I U I RL VERT(CL): 0.115 X 999 240 A 190 I- A /142 /63 1188 HORZ(LL): 0.040 W - - U 1375 A I- 1898 /345 /- HORZ(TL): 0.072 W - - P 828 I-52 P /421 190 /- Creep Factor. 2.0 L 835 A /- 1564 /238 A Max TC CSI: 0.620 Wind reactions based on MWFRS Max BC CSI: 0.657 A Big Width = 7.6 Min Req = 1.5 Max Web CSI: 0.676 U Big Width = 7.6 Min Req = 1.6 P Brg Width = 7.6 Min Req = 1.5 Wgt: 218.4 lbs L Brg Width = 7.6 Min Req = 1.5 Bearings A, U, P, & L are a rigid surface. VIEW Ver. 19.01.00A.0618.15 Bearings A, U, P, & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 186 -206 G - H 293 .67 B-C 482 -211 H-1 296 -68 C-D 1146 -428 I-J 617 -658 D-E 1154 -433 J-K 512 -814 E-F 468 -177 K-L 640 -1193 F-G 469 .178 L-M 35 -15 Maximum got Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B-X 310 -336 R-Q 112 -257 X-V 20 -32 P-O 413 -167 W-U 0 -8 O-N 413 -167 V-T 21 -29 N-L 1008 -481 S-R 467 -853 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-X 267 -97 F-R 193 -456 C-S 547-1079 R-G 280 -2B4 X - S 294 -299 G - Q 483 -192 W-V 43 0 H-Q 145 -209 D-S 94 -148 Q-P 365 -193 S - T 716 -1373 P -1 301 -723 S - E 450 -749 I - N 402 -134 T-U 716-1359 N-J 172 -58 E - R 825 -363 N - K 269 -406 enm sheet before use. Unless otherwise slated on the TD 1, the seal on any TDD represents an acceplance of Ne pi s, loading conditions, sullabiny and use ofthis Toss for ai ie IBC, IOW building code eib TPI-1. The approval of Ne Designerand! Con radon All notes selout N the TDD and rgeneral guldance. TP14 derines the responsibilities ant w lfte by all portion Involved. The Speclalty Engineer is N Job Truss Truss Type Oty Ply 02/05/2020 `f�RMSBM1674BG A15 COMN 1 I1 I 2614 T T T a N TL- L i6'6'6--i we-^1 3-9-10---J--35'10-1� SEAT PLATE RED. SEAT PLATE RED. —11'4.3 --ice Loading Criteria (pi Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzl: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 - MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.80 ft Loc. from endwall: not in 4.50' GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 :Tl 2x6 SP #2 got chord 2x4 SP #2 Webs 2x4 SP #3 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Plating Notes All plates are 1.5X3 except as noted. (++) - This plate works for both joints covered. (•')1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purling In lieu of structural panels use purling to brace all flat TC @ 24- Do. Wind Wind loads based on MWFRS with additional C&C member design. Please thoroughly review Me-A-1ROOF TRUSSES (-SELLER'), GENERAL TERMS and amateur and reatl notes on this Truss Design Drev/ng (TED) and the Spedelry Engineer reference shall be used for the Too to be valid. As a Truss Design Engineering 0 e. S" alty Engineer), Me the design of the single Truss depicted on Me Too only, under TPl-1. The design assumpgons, loa SEAT PIATE RED. Defl/CSI Criteria PP Deflection In loc Udell L#f VERT(LL): 0.091 AK 999 3E €18RT(CL): 0.164 AK 812 24 1-10 L): 0.070 AC - HORZ(TL): 0.126 AC - Creep Factor: 2.0 Max TC CSI: 0.883 Max BC CSI: 0.917 Max Web CSI: 0.889 Wgl: 250.6lbs VIEW Ver. 19.01.00A.0618.15 use of . The SEAT PLATE RED. 19'8'3 ♦ Maximum Reactions (Ibs) A 354 /- /- 1167 /166 /201 AE 916 I- I- /574 /310 /- Y 985 1- 1- 1508 /310 /- S 829 /- 1• 1536 /352 /- Wind reactions based on MWFRS A Brg Width = 7.6 Min Req = 1.5 AE Brg Width = 7.6 Min Req = 1.5 Y Brg Width = 7.6 Min Req = 1.5 S Brg Width = 7.6 Min Req = 1.5 Bearings A, AE, Y, & S are a. rigid surface. Bearings A, AE, Y, & S require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 202 -219 K-L 270 -77 B - C 269 -333 L - M 266 -75 C-D 307 -282 M-N 266 -75 D - E 300 -272 N - O 403 -523 E-F 582 -221 O-P 402 -526 F-G 176 -96 P-O 551 -791 G-H 215 -87 O-R 556 -945 H-1 213 -87 R-S 671 -1251 1-1 165 -110 S-T 35 -15 J - K 336 -41 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B-AK 310 -77 AB -AA 293 -490 AK -AI 189 -336 AA-Z 12 -7 AJ-AE 9 -7 Z-X 12 -7 AI-AH 197 -341 Y-W 8 -12 AG-AF 278 -474 W-V 679 -307 AF-AD 277 -471 V - U 679 -307 AC -AB 293 -489 U - S 1068 -520 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-AL 117 -259 1-AU 142 -42 AL -AK 117 -251 AU-J 212 -215 AL -AM 30 -28 J-X 376 -966 AK -AM 682 -268 X-Y 370 -956 AN -AO 736 -302 K-AV 730 -226 AN-AH 69 -94 AV- W 739 -240 D-AO 74 -109 AV-AW 71 -38 AO -AP 773 -327 W-AW 459 -941 AJ-AI 42 0 AX-AY 262 -574 NLEDGMENr fin. au be Vie reslxIDa b iily of Me Building Designer and Gonl2dor. All notes ed by TPI and SBCAMe referenced forgenerelguidance. TPI-ldefines defined by a Contract agreed upon in wngng by all parties involved. The tennsere as def ed In TPI-1. -nmNN1M vft d..mmtiaaYmMt.1RmTn— and Truss Job 1674BG Truss Truss Type B01 IGABL i 5'10" Dry I Ply 02/05/2020 1 1 �- Sit 0" D=4X4 I- I ­r -I r- I r -7 Loading Criteria (pan Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: It EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 15.00 It NCSCLL: 10.00 TCDL: 4.2 psi Load Duration: 1.25 BCDL: 4.2 psi Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: Any GCpI: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 got chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 1.5X3 except as noted Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0v10(10) Plate Type(s): WAVE Loading Truss designed to support 2-0-0 top chord outlookers and Gadding load not to exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. "WARNING" Please Morouahly review Me -A-1 ROOF TRUSSES Deft/CSI Criteria PP Deflection in too L/defl L/# VERT(LL): -0.002 H 999 361 ktRT(CL): 0.004 H 999 241 HORZ(LL):-0.004 J - - HORZ(TL): 0.004 J - - Creep Factor. 2.0 Max TC CSI: 0.438 Max BC CSI: 0.095 Max Web CSI: 0.188 Wgt: 51.8 lbs VIEW Ver. 19.01.00A.0618.15 no Madng shall be Me responslbilly of Me Building Designer and Cone 3SCn pu dished by TPI and SECA ere referencetl forgenerel guidance ass othdwise der ed by s Contend agmed upon invnldng by all paNe All sepital¢ed terns are as defined In TPI-1. N.nmyfmm.4 rvMiiNtM W,Nu11Mw,nNn,mNavn NFIFMTnuraa 2594 ♦ Maximum Reactions (Ibs), or •=PLF Gravity Non -Gravity Loc R+ / R- / Rh I Rw / U / RL F• 181 /- /- /65 1116 /19 Wind reactions based on MWFRS F Brg Width = 140 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 75 0 D-E 354 -139 B-C 176 -159 E-F 157 -159 C-D 373 -139 F-G 75 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-J 256 -75 I-H 268 -78 J-1 268 -78 H-F 249 -81 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - J 637 -457 H - E 637 -457 D-1 8 -164 I CUSTOMER ('BUYER") ACKNOWLEDGMENT" fens. se. Unless pibewue s stated on the Too, only Alpine )D represents an acceptance of Me pmfasslonal engineer suitabirdyand use of this Truss for any Building Is Me oodeand TPl-1. Theapprovalofthe TDDandanyrld ido, M notes setWin Me TDD and Me practices end TPI-I defines the responsiblptles and dudes of Me Truss imeNed. The Specialty Engineer is NOT Me ion IWas INss Iype Uty I Fly U2/Ubr1U2U WRMSBM1674BG B02 COMN 5'10" 5'10" —� SEAT PLATE REQ. SEAT PLATE RED. 11'8" F— 1'4° 1'4" -' Loading Criteria (peg Wind Criteria Code / Misc Criteria De0/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: F13C 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.009 F 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.016 F 999 240 B 525 /- /- 1320 1132 1110 BCDL: 7.00 Risk Category: It FT/RT:10(0)/10(10) HORZ(LL): 0.004 F - - D 525 /- /- 1238 1132 /- Des Ld: 37.00 EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.008 F - - Wind reactions based on MWFRS Mean Height: 15.00 ft WAVE Creep Factor. 2.0 B Brg Width = 7.6 Min Req = 1.5 NCBCLL: 10.00 TCDL: 4.2 psf Max TC CSI: 0.407 D Brg Width = 7.6 Min Req = 1.5 Load 1.25 ° BCDL: 4.2 psi Max BC CSI: 0.307 Bearings B & D are a rigid surface. 24.Duration; Spacing: Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 Bearings B & D require a seat plate. C&C Dist a: ft Max Web CSI: 0.083 dwa Loc. from endwall: Any Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Wgt: 46.2 lbs Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A-B 35 0 C-D 526 -593 Lumber B-C 526 -593 D-E 35 0 Top chord 2x4 SP #2 got chord 2x4 SP #2 Maximum got Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. Wind S-F 469 -269 F-D 469 -269 Wind loads based on MWFRS with additional C&C member design. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C-F 218 -33 "WARNING" Please Vasty design parameters am form. mm�R dN I RMTm— rode and TPI-1. The al xor. MnmssetaAin TPIA defines the rear, Job Truss Truss Type Qty Ply 02/05/2020 WRMSBM1674BG B03 COMN I1 I1 zsoa t- 511 On i 5110" T 12 6 p in �-113X4(++)C io K33 A KL 1111.5X4 SEAT PLATE REQ. i �-- 1'4" --}- — 2710 --{� Loading Criteria (psq TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes (++) - This plate works for both Joints covered. Code I Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(Ov10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. E=3X6(++) J 1111.5X3 11'8" 6'4"12 DeflICSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.206 H 662 36i VERT(CL): 0.380 H 359 24, HORZ(LL): 0.188 H - - HORZ(TL): 0.347 H - - Creep Factor: 2.0 Max TC CSI: 0.468 Max BC CSI: 0.404 Max Web CSI: 0.825 Wgt. 51.8lbs VIEW Ver. 19.01.00A.0618.15 E SEAT PLATE REQ. 2710 --1 1'4" —{ ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ I R- I Rh / RW I U / RL B 525 /- !- /319 /131 /110 F 525 /- /- /319 /131 (- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req = 1.5 F Brg Width = 7.6 Min Req = 1.5 Bearings B 8 F are a rigid surface. Bearings B & F require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 35 0 D-E 368 -839 B-C 218 -393 E-F 231 -393 C- D 386 -839 F- G 35 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 223 -67 J - H 794 -228 K - J 794 -228 I - F 223 -79 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-K 95 0 H-1 56 -12 K-L 56 -10 H-E 95 -2 D-J 211 -39 I responsibllity ofthe Building Designer and Contador. All notes set out In the TDD and the pR land SBCAarenderenoedfargenealpWanoe. TPI-1 defines Neresismaltilitics and dales by a Contract agreed upon In uniting by all parties involved The apeclalty Engineer is NOT the a as defined In TPI.1. M WIL-1 Mxw ,nvmiwim.1A.1RMTn— Job WRMSBM1674BG Truss Truss Type C01 GABL 1ty 11y 102/05/2020 v •26T i for i 10• Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Sld: ASCE 7.10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 15.00 it NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 1.5X3 except as noted Code I Mlsc Criteria Code: FBC 2017 RES TPI Sld: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Loading Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed 8.00 PSF one face and 24.0° span opposite face. Top chord must not be cut or notched, unless specified otherwise. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. Defl/CSI Criteria PP Deflection In loc L/defl LI# VERT(LL). 0.002 1 999 360 �qAERT(CL): 0.004 1 999 240 HORZ(LL):-0.001 F - - HORZ(TL): 0.002 N - - Creep Factor: 2.0 Max TC CSI: 0.401 Max BC CSI: 0.078 Max Web CSI: 0.198 Wgt: 116.2 lbs VIEW Ver. 19.01.00A.0618.15 t 1 ♦ Maximum Reactions (Ibs), or •=PLF Gravity Non -Gravity Loc R+ / R. / Rh / Rw / U / RL L• 178 /- /- 160 /51 116 Wind reactions based on MWFRS L Brg Width = 240 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 75 0 G-H 343 0 B-C 51 -147 H-1 210 -30 C-D 140 .137 I-J 252 -131 D-E 252 -131 J-K 140 -137 E-F 210 -30 K-L 51 -147 F-G 343 0 L-M 75 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B-V 262 -83 R-Q 276 -87 V-U 271 -84 Q-P 276 -87 U-T 277 -87 P-O 277 -87 T-S 276 -87 O-N 271 -84 S - R 276 -87 N - L 262 -83 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp E - W 251 -256 R - Z 260 -224 W - X 243 -197 AA -AB 243 -197 Y-R 260 -224 AS-1 251 -256 G-R 0 -394 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp C-V 188 -207 Z-Q 455 -372 D - U 233 -298 H -AA 469 -405 T-W 29 -111 AB-P 29 -111 X - F 469 -405 O - J 233 -298 S-Y 455 -372 N-K 188 -2077 -WARNING" Please thoroughly remw Ne-A-1 ROOF TRUSSES ('SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER ( -BUYER') ACKNOWLEDGMENT- rem. 'erify design pemmetem and read notes on We Toss Design Drawing (Too) and One Specialty Engineer reference sheet before use. Unless othervAse stated on the TDD, only Alpine XI capitalized trams are as def ed in TPH. NN-0— Is omN1JIM uBiwn IM wi---LW MAA RW Tnrawa Job Truss Truss Type Qty Ply 02/05/2020 WRMSBM1674BG I CO2 I COMN 13 I 1 2605 Loading Criteria (csp TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bol chord 2x4 SP #2 Webs 2x4 SP #3 i 10 10, I 1 SEAT PLATE REo. SEAT PLATE MO. 20' I-1'4'-I Wind Criteria Wind Std: ASCE7-10 Speed: 160 mph Enclosure: Closed Risk Category. ll EXP: B Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 4.2 psi MWFRS Parallel Dist 0 to h2 C&C Dist a: 3.00 it Loc. from endwall: Any GCpl: 0.18 Wind Duration: 1.60 Code I Misc Criteria Code:FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(Ov1O(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. I-1'4'-I Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in lob Udell LN Gravity Non -Gravity VERT(LL): 0.038 H 999 360 Loc R+ / R- / Rh / Rw / U I RL B 843 /- A /491 1209 1165 VERT(CL): 0.071 H 999 240 HORZ(LL): 0.017 H - - F 843 A /- 1491 209 /- HORZ(fL): 0.031 H - - Wind reactions based on MWFRS Creep Factor. 2.0 B Brg Width = 7.6 Min Req = 1.5 Max TCCSI: 0.313 F Brg Width =7.6 Min Req=1.5 Max BC CSI: 0.862 Bearings B & F are a rigid surface. Max Web CSI: 0.206 Bearings B & F require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 85.4 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A-B 35 0 D-E 743 -918 8 - C 874 -1229 E - F 874 -1229 C-D 743 -918 F-G 35 0 Maximum But Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp. B-H 1040 -633 H-F 1040 -649 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - H 371 -337 H - E 370 -337 D - H 540 -384 N dsr u rmu.. Job Truss Tmss Type Qty I Ply WRMSBM1674BG I HRS I HIP 1 1 02/05/2020 0 ,,2747 Loading Criteria (,Q Wind Criteria TCLL: 20.00 Wnd Std: ASCE7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category. II EXP:B KzL, NA Des Ld: 37.00 Mean Height: 15.00 R NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psi Spacing: 24.0 MWFRS Parallel Dist: 0to h/2 C&C Dist a: 3.00 It Loc. from endwall: not in 4.50 GCpi: 0.18 Wmtl Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Special Loads -(Lumber Dur.Fac =1.25 / Plate Dur.Fac =1.25) TC: From 0 plf at -1.97 to 61 pit at 0.00 TC: From 2 plf at 0.00 to 2 plf at 5.98 BC: From 2 plf at 0.00 to 2 plf at 5.98 TC: 67 lb Conic. Load at 0.43 TC: -12 Ib Conc. Load at 1.29 TC: 174 lb Cona Load at 3.26 BC: 44 Ito Conc. Load at OA3 BC: 15lb Conc. Load at 1.29 BC: 116 lb Conc. Load at 3.26 Wind Wind loads and reactions based on MWFRS. Left bottom chord exposed to wind. M M c Td]d vu 11.WB TA HB SB'd 1 E D 1111.BX1 srw.rureBEo. I-rn•n - sav-�( } V1192 � i 5Y i I IW 1167 Code I Misc Criteria Code:FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FTIRT:10(Ov10(10) Plate Type(s): WAVE DeRICSI Criteria PP Deflection In loc Udefl L/# VERT(LL): -0.000 B 999 36( '15tRT(CL): 0.001 B 999 24( HORZ(LL): 0.000 B - - HORZ(TL): 0.000 B - - Creep Factor. 2.0 Max TC CSI: 0.732 Max BC CSI: 0.565 Max Web CSI: 0.039 Wgt 23.8lbs VIEW Ver. 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- I Rh I RW / U / RL E 317 P A /- /126 I- D 102 A 1- 15/- C 97 A I- A 144 /- Wind reactions based on MWFRS E Brg Width = 9.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Bearing E requires a seal plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 20 -9 B-C 34 -48 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. E-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B-E 131 -205 ('BUYER-)ACKNOWI.EDGME foes. R Tn- ln�d. is NOT Ne Job Truss Truss Type Oty Ply 02/0512020 WRMSiSM1674BG I J1 I HIP 1 1 1 2683 T -i8a 25M F- 1'5-8 --�- Z9'15 t 2-9-IS t 7a-11 ----i SEAT PLATE REQ. (-190'10 9110-1 Loading Criteria (w9 Wind Criteria TCLL: 20.00 Wind Std: ASCE7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category. It EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 it NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 MWFRS Parallel Dist 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Special Loads -(Lumber Dur.Fac =1.25 / Plate Dur.Fac=1.25) TC: From 61 plf at -1.89 to 61 plf at 9.84 BC: From 14 pit at 0.00 to 14 pit at 9.84 TC: -18lb Cone. Load at 1.46 TC: 134 lb Conc. Load at 4.29 TC: 258 Ib Conc. Load at 7.12 BC: 13 lb Conc. Load at 1.46 BC: 87 lb Conc. Load at 4.29 BC: 156 lb Conc. Load at 7.12 Wind Wind loads and reactions based on MWFRS. D t t j i i i e]» 13X 156# Code / Misc Criteria DeBICSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in Loc Udell L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.039 G 999 360 Lee R+ / R- / Rh / Rw / U / RL B 739 /_ /_ /_ 1319 Rep Factors Used: Varies by Ld C syERT(CL): 0.071 G 999 240 FT/RT:10(Ov10(10) HORZ(LL): 0.010 F - - E 494 /- !- P 1109 /- Plate Type(s): HORZ(TL): 0.018 F - - D 249 /- P /- /106 /- WAVE Creep Factor. 2.0 Wind reactions based on MWFRS Max TC CSI: 0.684 B Brg Width = 10.0 Min Req = 1.5 Max BC CSI: 0.590 E Erg Width = 1.5 Min Req = - Max Web CSI: 0.904 D Brg Width = 1.5 Min Req = - Beadng B is a rigid surface. Wgt: 44.8 lbs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A-B 37 -17 C-D 83 -115 B - C 477 -1454 Maximum Bat Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-G 1354 .423 F-E 0 0 G - F 1339 -425 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. G- C 247 0 C- F 444 -1397 Job l nlss WRMSBM1674BG J1 -Inks -type JACK Qty y 102105/2020 2 11 a s 2674 Loading Criteria tx4 Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: ll EXP: B Kri: NA Des Ld: 37.00 Mean Height 15.00 it NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 ° MWFRS Parallel Dist 0 to h12 C&C Dist a: 3.00 ft Loc. from endvrall: Any GCpl: 0.18 Wind Duration: 1.60 0 12 6 2X4(A1) B C SEAT PLATE REQ. �- 1'4" Code 1 Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(Oy10(10) Plate Type(s): WAVE Lumber Top chord 2x4 SP #2 But chord 2x4 SP #2 Wind Wind loads based on MWFRS with additional C&C member design. "WARNING - review Ih -A-1 ROOF TERMS end -F T M 0 CV DeflICSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection In too Well L14 Gravity Non -Gravity VERT(LL): NA Loc R+ / R. / Rh l Rw l U 1 RL VERT(CL): NA B 196 /- /- /170 168 133 HORZ(LL):-0.000 D - - D 6 /-10 1- /15 /15 1- HORZ(TL): 0.000 D - - C - 1-30 1- 128 /41 !- Creep Factor. 2.0 Wind reactions based on MWFRS Max TC CSI: 0.282 B Brg Width = 7.6 Min Req = 1.5 Max BC CSI: 0.037 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.000 C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 5.61bs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A-B 35 0 B-C 52 -28 Maximum got Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 loin. xwTmm System Engineerolenyb1dN. Mraplali]idtemuereasddmx NTFFl. A1aMTucwe-aM�men:e.Nlba Mn N.Narvlmm.bmMYMM udM�tlpwilLm rmnicinnMMI WnI Tn�uw. Job Truss Truss Type Qty Ply 0210512020 WRMSSM1674BG I J3 I JACK 12 11 I2677 13 1'4" SEAT PLATE REQ. Loading Criteria (psq Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(OY10(10) EXP: B Krt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 15.00 ft WAVE NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 ° MWFRS Parallel Dist 0 to h12 C&C Dist a: 3.00 it Loc. from endwall: Any GCpi: 0.18 Wind Duraflon: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Wind Wind loads based on MWFRS with additional C&C member design. Nease thoroughly neWew Ne-A-1 ROOF TRUSSES ('SELLER-), GENERAL TERMS and vs and road rotes on Nis Tross Design Dn wing (TDD) and me specialty Eylnessrere erce be used for to MD In be vaxL As a Truss Desion Enalreednw n.e. SosialN Eminawl. Ne C T CO C3 � N 1" 3' -� Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): NA LOG R+ / R- / Rh / Rw / U / RL B 221 A /_ 1168 /51 163 VERT(CL): NA HORZ(LL): 0.001 D - - D 44 /- !- /31 12 /- HORZ(TL): 0.001 D - - C 67 /- !- /29 129 /- Creep Factor. 2.0 Wind reactions based on MWFRS Max TC CSI: 0.322 B Erg Width = 7.6 Min Req = 1.5 Max BC CSI: 0.075 D Erg Width =1.5 Min Req = - Max Web CSI: 0.000 C Erg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 11.2 lbs Bearing B requires a seal plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A-S 35 0 B-C 30 -90 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 form. ig Deognerand Conbachs, All notes fcrgeneralpWance. TPi4dennes In writing by an padiee invdved. The rN41aWT.— .ad Truss Job Truss Truss Type Qty Ply 02/052020 WRMSBM1674BG I J3A I JACK 11 11 I " 1,270.1 T3 1'4" C SEAT PLATE REQ. 3' -{ T 0 LO N Loading Criteria (par) Wind Criteria Code / Misc Criteria DeflIC81 Criteria ♦ Maximum Reactions (Ibs), or •=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc LJdef) L1# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): NA Loc R+ ! R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA D' 74 /- /- 156 117 21 BCDL: 7.00 Risk Category. II FTIRT:10(Oy10(10) HORZ(LL): 0.001 D - - D 44 /- /- /31 12 /- EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.001 D - - C 67 /- !- 29 29 !- Des Ld: 37.00 Mean Height: 15.00It WAVE Creep Factor. 2.0 Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.2 psf Max TC CSI: 0.162 D Brg Width = 36.0 Min Req = - Duration: 1.25 BCDL: 4.2 psi Max BC CSI: 0.066 D Brg Width = 1.5 Min Req = - Sad Spacing: 24.0 ° p MWFRS Parallel Dist: h2 to h C Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 it Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: not in 9.00 Wgt: 11.2 Ibs Bearing B requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 I Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP #2 A - B 35 0 B - C 30 -64 Sot chord 2x4 SP #2 Maximum Sot Chord Forces Per Ply (Ibs) Plating Notes Chards Tens.Comp. All plates are 2X4(A1) except as noted. B - D 0 0 Wind Wind loads based on MWFRS with additional C&C member design "WARNING" Please thoroughlyreviewipe-A-1 ROOF TRUSSES(-SELLER'),GENERA TERMS and CONDITIONS CUSTOMER entry design parameters and read noses on N¢Truss Deal Dm ng(MD) and Me Specialty Enghwerrefeeence sheet before use. Unless oft av —&,Ie Tnave. Job Truss Truss Type City Ply 02/05/2020 4VRMSBM1674BG J5 I JACK 13 11 I 2680 T3 SEAT PLATE REQ. �-- 1-4e 1 5' Loading Criteria (psq Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: It EXP: B ": NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psi Spacing: 24.0 ° MWFRS Parallel Dist 0 to h2 C&C Dist a: 3.00 it Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RTAO(Ov10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. ^WARNING" Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LQ: NA Loc R+ / R- / Rh / Rw / U / RL B 288 /- /- /207 /58 /92 VERT(CL): NA HORZ(LL): 0.005 D - - D 78 /- /- /50 /4 /- HORZ(TL): 0.009 D - - C 129 /- /- 164 155 F Creep Factor. 2.0 Wind reactions based on MWFRS Max TCCSI: 0.318 B Brg Width =7.6 Min Req =1.5 Max BC CSI: 0.221 D Brg Width =1.5 Min Req = - Max Web CSI: 0.000 C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 18.2 IDS Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A-B 35 0 B-C 58 -109 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 and CONDITIONS CUSTOMER ('BUYER') ACKNOWLEDGMENP fmm. :nae sheet before use. Unless otherwise stated on the TOD, only Alpine the seal an any TDO represents an ecceptanca of fine proteslonal eigineen loading conditions, suitability and use of Nis Truss for any Building a to i IBC, local building code and M-1. Theappal"lofthe TDOandanyfold esignerand Comrador. Allnotasseloutinihe TDDandiheprac end Job Truss Truss Type Qty Ply 02/05/2020 WRMSBM1674BG I A06 COMN 113 I 1 I " 261' T b TL 1 SEAT PLATE REG. (-28'8—�13710 ®2X4 a4x10s3xe 38' 20.8 SEAT PLATE RE 1978 14�{ Loading Criteria (psq Wind Criteria Code / Misc Criteria De0/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code:FBC 2017 RES PP Deflection in loc Well L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): 0.210 T 999 360 Loc R+ ! R- / Rh ! Rw / U l RL SCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.399 T 999 240 A 1468 !- !- 1809 1346 1290 BCDL: 7.00 Risk Category. ll FT/RT:10(0y10(10) HORZ(LL): 0.135 L - • J 1513 /- /- /900 /373 /- EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.256 L - - Wind reactions based on MWFRS Des Ld: 37.00 Mean Height: 15.00 ft WAVE Creep Factor: 20. A Br Width = 7.6 Min Re 1.5 9 q = NCBCLL: 10.00 TCDL: 4.2 sf p Max TC CSI: 0.468 J Width=re Min =1.8 Load Duration: 1.25 ° BCDL: 4.2 Max BC CSI: 706 ing A 8 J are a rigid surface. . Spacing: 24.0 Parallel MWFRS Parallel Dist: h12 to h Bearings A 8 J require a seat plate. C8C Dist a: 3.80 it Max Web CSI: 0.750 Maximum Top Chord Forces Per Ply (Ibs) Lac. from not in 9.00 Wgt: 311.5lbs Chords Tens.Comp. Chords Tens. Comp. GCpl: 0.18 .18 i: Wind Duration: 1.60 VIEWVer. 19.01.00A.0618.15 A-B 366 -635 F-G 934 -2165 Lumber B•C 1309 -3270 G-H 927 -1965 C - D 1176 -2818 H -1 925 -2137 Top chord 2x4 SP #2 :T1 2x8 SP 2400f-1.8E: D-E 887-2007 I-J 1055 -2665 :T22x6 SP#2: Bot chord 2x4 SP#2:B1, B22x6 SP#2: E-F 993-2DO4 J-K 35 0 Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) Continuous lateral restraint equally spaced on member. B - V 3175 -1079 R - O 2474 -774 Plating Notes V-U 3166-1077 Q-N 32 -11 U - T 3166 -1077 N - M 2304 -831 All plates are 1.5X3 except as noted. T-R 2506 -78B M-L 2304 -831 (")1 plate(s) require special positioning. Refer to scaled plate plot details for S - P 32 -13 L - J 2306 -831 special positioning requirements Tray Scab(s) (2) 2x8x9-3-5 x SP 2400f-1.8E scabs at left end. Attach one scab to each outer face of chord with: 0.131'x3', min. nails @ 8' oc, Plus additional nail dusters at: BRG.: (4), heel: (6). 1st panel point: (2). Wind Wind loads based on MWFRS with additional C&C member design. "WARNING- Please 0arouchlv review8re'A-1 ROOF TDDN seal an anv TDD remesents an Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp V-C 76 -162 O-F 180 -108 C - T 336 -770 O - G 202 -150 D-T 449 -135 O-N 1970 -636 D-O 449 -904 P-Q 83 0 S-R 43 -5 G-N 129 -442 E-0 1362 -6B0 N-1 271 -536 O-P 113 0 1-L 217 0 Job Truss Truss Type Qty Ply 02/0512020 WRMSBM1674BG A11 HIPS 1 I1 I 2470 55X6 D E a3X6 m5X6 F G H ill 12 6 T1 �2X4C (a) o (a) Ie�2X4 b B a 6$X6 T QT A 1 1 —3X8 S J�3XK(At) O O N M L 84 03X6(R) N2X4 E464 m3X6 m3X8 E3X6 SEAT PLATE REG. SEAT PLATE REG. SEAT PLATE REG. 1371 i 24T'3 i Loading Criteria (psq Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category: II EXP: B K t: NA Des Ld: 37.00 Mean Height 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf . Spacing: 24.0' MWFRS Parallel Dist' h/2 to h C&C Dist a: 3.79 it Loc. from endwall: not in 9.00' GCpi: 0.18 Wind Duration: 1.60 Top chard 2x4 SP #2 :T1 2x4 SP 24001-2.0E: Bot chord 2x4 SP #2:84 2x4 SP 24001-2.0E: Webs 2x4 SP #3 Code I Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT1RT:10(0v10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes Al plates are 3X4 except as noted. Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 8.27 26.94 BC 75 0.00 37.79 Apply puffins to any chords above or below fillers at 24' OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. "WARNING" De0/CSI Criteria A Maximum Reactions (Ibs) PP Deflection In Ioc L/de8 I-1# Gravity Non -Gravity VERT(LL): 0.042 L 999 360 Loc R+ / R- / Rh I Rw / U / RL VERT(CL): 0.080 L 999 240 R 473 P /- /428 /159 /186 HORZ(LL): 0.012 L - - P 1737 P !- /971 /395 /- HORZ(TL): 0.022 L - - J 944 P !- /602 /234 !- Creep Factor. 2.0 Wind reactions based on MWFRS Max TC CSI: 0.805 R Brg Width = 6.9 Min Req = 1.5 Max BC CSI: 0.493 P Brg Width = 7.6 Min Req = 2.0 Max Web CSI: 0.924 J Brg Width = 7.6 Min Req = 1.5 Bearings R, P. & J are a rigid surface. Wgt: 250.6 Ibs Bearings R, P. & J require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A- B 37 0 F- G 488 -200 B - C 262 -491 G - H 396 -602 C-D 206 -197 H-1 507 -10W D-E 174 -117 I-J 637 -1440 E-F 48B -200 J-K 35 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp R - Q 636 -706 N - M 900 -180 Q - P 636 -706 M - L 900 -180 P-0 370 -218 L-J 1231 -449 O - N 370 -218 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B- R 363 -405 T - U 335 -267 B - S 379 -146 E - U 589 -7&4 R-S 694 -437 P-U 951 -1567 C - T 289 -307 U - G 620 -1215 S - Q 344 -464 U - N 822 -365 S-T 521 -432 G-N 267 -3 S-P 1090 -781 N-H 247 -407 D-T 164 -262 H-L 422 -67 T - E 608 -476 L - I 306 -375 TERMS and CONDITIONS CUSTOMER ('BUYER-) ACKNOWLEDGMENT' form. ear afaranoa sheet before use. UNasa ofM1anMae steted on Ne TOD, oNy Npne awinewl. the seal on anv TOD ranrasents an awentanm of the nmf—onA enninnnE &.1 R Tnmaa Ne Job Truss Truss Type City Ply 02/05/2020 WRMSBM1674BG Al2 I HIPS 11 11 I A 4.250 9' —� 12 %SX8 =-4X4 C D T6 I u1.5X4 o B J Ia T. -5X6 1T 1 6X6 W1.5X4 S R Q P Ka=3%6(A7 WI—l1 11 Z V X UTV-4X8=3X6 m M L m3X8 ®3Xm N1.SX4-3X6 e5X6 E F G H 8 1.5%4 -4X4 SEAT PLATE REQ. SEAT PLATE RED, SEAT PLATE REO. 13,311 i 24'8.3 14'5'6 11S 778 i 14»{ II Loading Criteria (,q Wind Criteria Code I Misc Criteria Deb/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Sld: ASCE 7-10 Code: FBC 2017 RES PP Deflection In foe L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.071 P 999 360 Loc R+ / R- / Rh ! Rw I U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.134 P 999 240 Z 463 /- /- 1426 1206 /149 BCDL: 7.00 Risk Category. If FT/RT:10(Ov10(10) HORZ(LL): 0.023 M - - X 1835 /- /- 1982 1406 /- Des Ld: 37.00 EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.044 M - - K 894 /- 1- 1559 1230 !- Mean Height: 15.00 It WAVE Creep Factor. 2.0 Wind reactions based on MWFRS NCBLoad TCDL: 4.2 psf Max TC CSI: 0.793 Z Brg Width = 6.9 Min Req = 1.5 Du: tion: Load Duration: 1.25 BCDL: 4.2 pst Max BC CSI: 0.804 X Brg Width = 7.6 Min Req = 2.2 Spacing: 24.0' MWFRS Parallel Dist: hl2lo h K Brg Width = 7.6 Min Req = 1.5 C&C Dist a: 3.79 ft Max Web CSI: 0.655 Bearings Z, X, & K are a rigid surface. Loc. from endwall: not in 9.00 Wgt: 231.0 Ibs Bearings Z, X, & K require a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP#2 A-B 37 0 G-H 583 -1095 Bot chord 2x4 SP #2 B - C 588 -352 H -1 850 -1611 Webs 2x4 SP#3 C-D 869 -297 I-J 765 -1641 D - E 281 -392 J - K 659 -1444 Bracing E-F 281 -392 K-L 35 0 (a) Continuous lateral restraint equally spaced on member. F - G 281 -392 Plating Notes All plates are 3X4 except as noted. Pudins In lieu of stmctural panels or rigid ceiling use pudins to laterally brace chords as follows: Chard Spacing(in oc) Start(ft) End(ft) TC 24 6.27 28.94 BC 75 0.00 30.29 BC 93 30.29 37.79 Apply pudins to any chords above or below fillers at 24' OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp Z-Y 173 -135 S-R 1083 -342 Y-X 42 -83 R-Q 1083 -342 W-U 504 -818 Q-N 1198 -417 X-V 9 -18 P-O 0 0 U-S 507 -835 O-M 38 -18 V- T 0 0 M- K 1249 -524 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B-Z 580 -425 E-S 155 -315 B-Y 225 -345 G-Q 241 -48 C-Y 229 -360 Q-H 87 -128 C - W 799 -1049 H - N 620 -347 Y-W 369 -360 N-O 75 -5 W-X 945-1733 N-1 171 -165 W-D 584-1240 N-M 1245 -519 D-S 1493 -644 N-J 182 -58 U-V 90 -42 M-J 161 -320 S-G 416 -860 CONDmONS CUSTOMER (-BUYER-) AC"OWLEDGMEM- form. sheetbe. use. UNess otheWw staW w the MD. w1v Alpine r_n Job Truss Truss Type City Ply 1015Q020 WRMSSM1674BG I CJ1A I JACK 11 11 I 2521 12 6 F7, C 1111.5MB I TA o HB T'7 v m 1113X6E D SEAT PLATE REQ. �— 1-4.12 ° Loading Criteria(peq Wind Criteria Code /Misc Criteria TCLL: 20.00 Wind Sld: ASCE 7-10 Code: FSC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 SCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 7.00 Risk Category: II FT/RT:10(Ov10(10) EXP: B Kzt: NA Plate Type(s): Des Ld: 37.00 Mean Height: 15.00 It WAVE NCBCLL: 10.00 TCDL: 4.2 psf Load Duration: 1.25 BCDL: 4.2 psf Spacing: 24.0 ° MWFRS Parallel Dist: 0 to h12 C&C Dist a: 3.00 it Loc, from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Sot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 11 0.00 0.91 Apply pudins to any chards above or below fillers at 24' OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design Please thoroughly mviewthe -A-1 DeBICSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.000 B 999 36( VERT(CL): 0.000 B 999 24( HORZ(LL): 0.000 B - - HORZ(TL): 0.000 B - - Creep Factor: 2.0 Max TC CSI: 0.180 Max BC CSI: 0.007 Max Web CSI: 0.094 Wgt: 8.4lbs VIEW Ver. 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ I R- I Rh I Rw / U / RL E 178 /- !- 1171 181 /- D 15 P /- 110 /- /- C - 1-32 P 146 160 133 Wind reactions based on MWFRS E Brg Width = 6.9 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 37 0 B-C 151 -59 Maximum Sot Chord Forces Per Ply (Ibs) Chords Tens.Comp. E-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B-E 317 -172 IS CUSTOMER (-BUYER-) ACKNIOWLEDGMENr from. use. Unless oMerwise stated on the Too, only Alpine by a Coned agreed upm in wriEng by all W a es detmed M TP41. N WnnpiMwNnnn i�Ln60.t anYTn¢su. Job Truss Truss Type DIN, Ply 02/052020 WRMSBM1674BG I CJ3A I JACK 11 11 I ,125 - C 12 iv A; O°HB 1'119 50 1 103X6E D SEAT PLATE REQ. P•i— 1'11'7 —� —1'4'12 —� j-- 22"'15 --{ Loading Criteria (F-A Wind Criteria Code I Mist: Criteria DefUCSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L#I Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.000 B 999 360 Loc R+ / R- / Rh / Rw I U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.000 B 999 240 E 193 !- I- 1169 NIS /- BCDL: 7.00 Risk Category. II FTlRT:10(Oy10(10) HORZ(LL): -0.000 B - - D 38 /- /- /23 /- /- EXP: B Kzt: NA Des Ld: 37.00 Plate Type(s): HORZ(TL): 0.000 B - - C 45 /- /- 138 115 /53 Mean Height: 15.00 ft WAVE Creep Factor. 2.0 Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.2 psf Max TC C51: 0.197 E Big Width = . Min Req = 1.5 Load Duration: 1.25 BCDL: 4.2 psi Max BC CSI: 0.050 D Big Width = 11.55 Min Req = - Spacing: 24.0' MWFRS Parallel Dist: 0 to h2 C Erg Width = 1.5 Min Req = - C&C oa: ft Max Web CSI: 0.091 Bearing E is a rigid surface. Loc. from m endwatlwall: not In 4.50 Wgt: 14.0 Ibs Bearing E requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP #2 A - B 37 0 B - C 156 -52 Sot chord 2x4 SP #2 Webs 2x4 SP #3 Maximum Bat Chord Farces Per Ply (Ibs) Chords Tens.Comp. Purlins In lieu of structural panels or rigid calling use pudins E- D 0 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) Maximum Web Forces Per Ply (Ibs) BC 27 0.00 2.24 Webs Tens.Comp. Apply puriins to any chords above or below fillers at 24' OC unless shown otherwise above. B - E 305 -178 Wind Wind loads based on MWFRS with additional C&C member design "WARNING— Please thoroughly reV.the -A-1 ROOF TRUSSES(°SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER ( -BUYER`) ACWOWLEDGMEN fora. 'edfy design parsoeaus and road evies on this Truss Design Drawing (MD) and the Sperlaly Engineorefee nm sheetbafore use. Unless oche Wse staled on the TOD, "Alpine by Conbaotal upon inviting by all part a as dermed in TPN. ,w4 Nw wtltu. � a L1 WaWTnea Job Truss WRMSBM1674BG I J3GE Truss Type JACK Cry Ply 1 I1 02/05M20 2527 1 i4" SEAT PLATE REQ. 27"11 D 1111.5X4 Loading Criteria (psq Wind Criteria Code / Misc Criteria DegICSI Criteria ♦ Maximum Reactions (Ibs), or•=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): NA Loc R+ / R- / Rh / Rw 1 U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA D' 106 /- /- f76 /13 115 BCDL: 7.00 Risk Category: II FT1RT:10(Ov10(10) HORZ(LL): 0.001 D - - Wind reactions based on MWFRS EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 15.00 it Plate Type(s): WAVE HORZ(TL): 0.001 D - - D Brg Width = 31.7 Min Req = - NCBCLL: 10.00 TCDL: 4.2 psf Creep Factor. 2.0 Bearing B is a rigid surface. Load Duration: 1.25 BCDL: 4.2 psi Max TC CSI: 0.186 Bearing B requires a seat plate. Spacing: 24.0MWFRS Parallel Dist: h to 2h Max SC CSI: 0.046 Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: 3.00 it Max Web CSI: 0.038 Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: not in 9.00 Wgl: 14.0 Ibs A - B 35 0 B - C 23 -53 GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 Maximum Bot Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Top chord 2x4 SP #2 B - D 155 -31 got chord 2x4 SP 42 Webs 2x4 SP #3 Maximum Web Forces Per Ply (Ibs) Purlins Webs Tens.Comp. In lieu of structural panels or rigid ceiling use pudins C - D 89 -54 to laterally brace chords as follows: Chord Spacing(n oc) Stari(ft) End(ft) SC 30 0.15 2.64 Apply pudins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. 'A-t ROOFTRUSSES ('SELLER-), GENERALTERMS and CONDMONS CUSTOMER ('BUYER') ACKNOWLEDGMENT' form. TDD in be valid. design RMToi The ei t out in Job Tmss WRMSBM1674BG R Truss Type EJAC 7 11y I 1120s12020 2692 0. T SEAT PLATE RED. �-- 1'4- —1- 7' Loading Criteria (pit Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 7.00 Risk Category. II EXP: B Kzt: NA Des Ld: 37.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 4.2 psi Load Duration: 1.25 BCDL: 4.2 psf Sparing: 24.0 ° MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpb 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Code I Misc Criteria Code: FBC 2017 RES TPI Sld: 2014 Rep Factors Used: Yes FTIRT:10(0y10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. 'RNARNING- PleasetMmugNyr .Ifire'A-I ROOF TRUSSES off, dwign para,.r. and rood rotes on ihis Truss Design Drawing (ME gnat! r plates shefi be used for Ne TDD to bawW. Asa buss Design E Defi/CSI Criteria PP Deflection in too Udefl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.015 D - - HORZ(TL): 0.027 D - - Creep Factor. 2.0 Max TC CSI: 0.711 Max BC CSI: 0.640 Max Web CSI: 0.000 Wgt: 23.8 Ibs VIEW Ver. 19.01.00A.0618.15 GENERAL TERMS and CONDITIONS C jalN EaoT. referenoa sheet before use. C ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- I Rh / Rw / U / RL B 361 /- A /328 /132 /182 D III /- 1- M42 167 /- C 187 P /- /95 /131 P Wind reactions based on MWFRS B Brg Width = 7.6 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width =1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 35 0 B-C 84 -140 Maxlmum Bat Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Wilding Designer and Conba .. An notes set out in the TOO and No pracOres and Inc W,enerelgukanoa. TP4l defines the respcnsibintleseM tlutles of Ne Truss upminwUNI,yanpaNesimolvad. The Spedalty EnSneeris NOTgre n Wn NM1 RMT— Job Truss WRMSRM1674BG I RC Truss Type EJAC Qty I Ply 8 1 02/052020 2689 SEAT PLATE REQ. A 1-4- T— 2'62 4 44'6 �I T i ij Loading Criteria (mit Wind Criteria Code / Misc Criteria DeIIICSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/de8 L#F Gravity Non -Gravity TCDL: 10.00 Speed: 160.mph TPI Sid: 2014 VERT(LL): 0.171 F 482 360 Loc R+ / R- / Rh / Rw / U / RL BOLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.316 F 260 240 B 361 1- /- 251 1132 1182 BCDL: 7.00 Risk Category II FTIRT:10(0v10(10) HORZ(LL): 0.081 G - - E 98 I- P /67 119 /- Des Ld: 37.00 EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.151 G - - D 190 /- /- /94 /132 P Mean Height: 25.00 It WAVE Creep Factor. 2.0 Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.2 psf MaX TC CSI: 0.786 B Brg Width = 7.6 Min Req = 1.5 Load Duration: 1.25 BCDL: 4.2 psf E Big Width =1.5 Min Req = - Spaclng:24.0' MWFRS Parallel Dist: 0 to h12 Max BC CSI: 0.348 D Big Width = 1.5 Min Req = - C&C Dist a: 3.00 itMax Web CSI: 0.279 Bearing B is a rigid surface. Loc. from endwall: not in 9.00 Wgt: 28.0 Ibs Bearing B requires a seat plate. Gatio 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 :1.6 VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. Lumber Top chord 2x4 SP#2 A-B 35 0 C-D 85 -118 But chord 2x4 SP#2 B-C 0 -197 Webs 2X4 SP #3 Plating Notes (++) - This plate works for both Joints covered. Wind Wind loads based on MWFRS with additional C&C member design. "WARNING^ Verify design pal TERMSaria CONOMONS CUSTOMER rer reference sheet we. use. UNeu oNi §gineerJ, Ne seal an anYTOD mpreseNa Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-H 84 -73 G-E 0 0 C-G 81 -36 H-F 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. G-H 72 -34 form. is by ell pelves Involved. The aWrn�eua set pal In the MDend fhe p.d aria the responslNlides and duties of Me Tmu ipe alty Eigireer N NOT Ne JUNE 20, 2019 I TYPICAL HIP / KING JACK CONNECTION I STDTLOI Y CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 Attach End Jack's w/ (4) 16d Toe Nails @ TC & (3) 16d Toe Nails @ BC 0 r Attach King Jack w/ (3) 16d Toe ,Nails @ TC & BC 3ch Corner Jack's (2) 16d Toe Nails � TC & BC (Typ) Attach Comer Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772-409.1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD I' - 3' MAX. DIAS. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 0 24' O.C. 2XG DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - IOd COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIND. PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. L9J1/1111 CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (131' X 3') NAILS SPACED 6' OZ. - FOR WINO SPEEDS GREATER 120 MPH (ASCE 7-99, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (131'X3') NAILS SPACED S' O.C. (2X4 STUDS MINIMUM). MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIOE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED \ STUDS ARE NOT ADDRESSED HERE STANDARD GABLE I TRUSS "^TURAL TRUSS STUD AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. 1. 12/23/19 PIGGY -BACK TRUSS STDTL04.1 A-1 ROOFTRUSSES :446i ST,LUCIE BLVD. FORT PIERCE, FL'34946 772409.1010: PIGGY -BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L = 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. "REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS" PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) 2'-0" MAX OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES -SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.S' X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO.3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) I0d BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION #1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24' O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. .• IMPORTANT NOTE •• THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED 1 STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-4094010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS DETAIL A GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3'X 0.131'= 10d 2. WOOD SCREW= 4.5SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A'. 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NOS -01. 7. VALLEY STUD SPACING NOT TO EXCEED 48'O.C. BASE TRUSSES P 112 VALLEYTRUSS GABLE END, COMMON (TYPICAL) TRUSS, OR GIRDER TRUSS BEL7SEETAYW ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO SIMPSON SDS25412 (1/4' X 4.5-) OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24' O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. FEBRUARY 5, 2018 I TRUSSED VALLEY SET DETAIL I STDTL06 GENERAL SPECIFICATIONS: �I 1. NAIL SIZE=3'X 0.131'=10C � 2. WOOD SCREW =3'SDS25300 SIMPSON OR EQUIVALENT. �i 3. INSTALL VALLEY TRUSSES (24.O.C. MAXIMUM) AND SECURE PER DETAIL �I 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN ' DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS-01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 46' O.C. FORT PIERCE, FL 34916 TRUSS, OR GIRDER 7 772-409-1010 TRUSS 1 SECURE W/( VALLEYTRUSS y II III I I II BASE TRUSSES II (TYPICAL) II II I DETAIL A (NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER VALLEY TRUSS TRUSS P 12 �\ (TYPICAL) SEE DETAIL'A' BELOW (NP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6112 CATERGORY II BUILDING EXPOSUREC WIND DURATION OF LOAD INCREASE 1.60 ATTACH 2X4 CONTINUOUS 92 MAX TOP CHORD TOTAL LOAD =50 PSF SYPTOTHEROOFW/TWO MAX SPACING= 24' O.C.(BASE AND VALLEY) SIMPSON SDS25300 (1/4' X 3') MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. JULY 17, 2017 11\LJJ%JLU VALLL_ 1 JL_ I UL_ 1!'LIL IGH WIND VE STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ATTA( WIND DESIGN PER ASCE 7-98. ASCE 7- WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT =30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24` O.C. (BASE AND VP SUPPORTING TRUSSES DIRECTLY UNU.n v.ILu in DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPFS SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON.BEVELED H I MAXIMUM 6/12 PITCH BOTTOM CHORD NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12112 PITCH) FEBRUARY 17, 2017 STANDARD GABLE END DETAIL STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS V/10d NAILS, 6' O.C. VER' STU[ SECTION B-B TRUSS GEOMETRY AN O CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. * DIAGONAL BRACING ** L - BRACING REFER REFER TO SECTION A -A TO SECTION B-B V 24' MAX. NOTE: 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE ENO TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT 4'-0' O.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 16d NAILS SPACED G' O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) IOd NAILS THROUGH 2X4 (REFER TO SECTION A -A) 7 GABLE STUD DEFLECTION MEETS OR EXCEEEOS L/240 VERTICALVSPACE 2X6 SP OR SPF STUD#2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED 6' O.C. (2) lOd NAILS INTO 2X62XE SP OR SPF #2 2X4 SP OR SPF 02L HORIZONTAL NAILED TO RTICALS SECTION A -A V/(4) - 10d NAILS PROVIDE 2X4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Bd NAILS MINIMUM, PLYWOOD SHEATHING TO 2X4 STD SPF BLOCK B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE 9. 00 NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0131'X3A' AND 0131'X35' COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE DG-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4SP>3ISTUD 121OZ. 3-8-10 5-6-11 6-6-11 11-113 2X4 SP 931 STUD 16'O.C. 3310 4.9-12 6-641 9-10-15 2X4SPA31STUD 24'O.C. 2-8­6 3-11-3 5-4-12 8-1-2 2X4SP#2 12.O.C. 3.10-15 5.6-11 6&11 11-8-14 2X4 SP s2 16. O.C. 3841 4-9-12 fi&11 10-H 2X45P12 24'O.C. 3-14 3.11-3 6.2-9 9313 j� DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS 6' D.C., WITH 3' MINIMUM ENO DISTANCE. BRACE MUST COVER 90'/. OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. ROOF SHEATHING (2) - 10d NAILS TRUSSES @ 24' O.C. '2X6 DIAGONAL BRACE SPACED 48. D.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d NAILS. HORIZONTAL BRACE (SEE SECTION A -A) END WALL ROOF HEIGHT =30 FEET BORC 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. OF LOAD INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS. FEBRUARY 17, 2017 I WITH 2X BRACE ONLY I STDTL09 NOTES: T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL T—BRACE / I —BRACE MUST COVER 90% OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 7'72.4D9.1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6- O.C. NOTE NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 20 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 1—BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X8 I —BRACE 2XB 2XB T—BRACE 2X8 I —BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS NAILS WEB M( NAILS WEB I -BRACE T-BRACE SECTION DETAILS � � y FEBRUARY17,2017 LATERAL BRACING RECOMMENDATIONS STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. .I NOTE 1: 2X6 STRONGSACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE ddwTOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4461 Si. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REOUIREMENTS FOR THE 772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE METAL FRAMING \�611'1' TCH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOQ TOPATTACHCHDRO AS (0 3131X 3)) \ NAILS - lad CAB `(0131.ITH 3X 3'). ATTACH NALS (0TO VERTICAL \ WEB WITH (3) - 10d BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0131' X 7) IN EACH CHORD ATTACH TO CHORD WITH (2) H12 X 3' WOOD SCREWS (MS' DIA1 USE METAL FRAMING J ATTACH TO VERTICAL ATTACH TO VERTICAL '-INSERT SCREW THROUGH ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 101 OUTSIDE FACE OF CHORD INTO TO BOTTOM CHORD NAILS (0131' X 3') NAILS (0131' X 3') EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) TRUSS 2X6 4' STRONGBACK (TYPICAL 0' WALL SPLICE) (BY OTHERS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM [IF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTLI1 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 o.135 93.5 85.6 74.2 72.6 63.4 J in .162 108.8 99.6 86.4 84.5 73.8 �i .128 74.2 67.9 58.9 57.6 50.3 z .131 75.9 69.5 60.3 59.0 51.1 J N .148 81.4 1 74.5 64.6 63.2 52.5 ri VALUES SHOWN ARE CAPACITY PER TOE -NAIL APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 115: 3 (NAILS) X 845 (LB/NAIL) X 115 (OOL) = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60' 45.00' ANGLE MAY VARY FROM 30' TO SD' THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (20) 2 NAILS NEAR SIDE FXF NEAR SIDE SIDE VIEW (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30' TO 60' 45.00° FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORTPIERCE, FL 34946 772-409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S LD .131 59 46 32 30 20 z J .135 60 48 33 30 20 Ln (7 .162 72 58 39 37 25 J 2 .128 54 42 28 27 19 F- LD Z Z OJ .131 55 43 29 28 19 LLI .148 62 48 34 31 21 J in J N Q M Z .120 51 39 27 26 17 Z .128 49 38 26 25 17 O .131 51 39 27 26 17 0 .148 57 44 31 28 20 M NOTES: L TOE -MAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 133 (DOL FOR WIND) = 14B LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF LED: 3 (NAILS) X 37 (LB/NAIL) X 1.60 IDOL FOR WINO) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. 000 USE (3) TOE -NAILS ON 2X4 BEARING WALL set USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S IE TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW END VIEW 5, 2016 1 TYP 2x2 NAILER ATTACHMENT I STDTL13 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-469-1010 0X4 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTL14 v A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES (4) 12d MAX 3011 (21-611) 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 % STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND FEBRUARY 17, 2017 1 DAMAGED OR MISSING CHORD SPLICE PLATES 1 STDTL15 AA ROOF TRUSSES 4451 ST. WCIE BLVD. FORT PIERCE, FL 3494 7I2-409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 3011 1697 2546 173E 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48' 3657 5485 3346 5019 2829 4243 2898 4347 • DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 39. STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C �- SMpT BREAK 2 'f d NAILS NEAR SIDE \01 \ +10d NAILS FAR SIDE4X' MIN �- 6' MIN TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. v 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. y FEBRUARY17,2017 SCAB APPLIED OVERHANGS STDTL16 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-4MI010 TRUSS CRITERIA: LOADING: 4D-ID-D-10 DURATION FACTOR: 115 SPACING: 24' D.C. TOP CHORD: 2X4 OR 2XG PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL ENO BEARING CONDITION NOTES: L ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF IDd COMMON WIRE NAILS (14B' DIA. X 3') SPACED 6' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES