RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include:
This checklist
A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (one page) and an input summary checklist that can
be used for field verification (usually fourpages/may be greater).
Energy Performance Level (EPL) Display Card (one page)
,C5-- ;HVAC ystem sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
Mandatory Requirements (five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report (usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
b...
REVIEWED FOR
CODE COMPLIANCE
ST" _LICIf�
E�C/+
2OUNTY
3117020 10:14:30 AM EnergyGauge® USA 6.0.04 (Rev. 1) - RaRes2017 FBC 6th Edition (2017�)ompliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: RENARBERMUDA 1686
Builder Name: RENAR HOMES
Street:
Permit Offloe: FTPIERCE
City, State, Zip: FT PIERCE, FL.
Permit Number:
Owner. FERRUCCI
Jurisdiction: 661100
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1532.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Inl Insul, Exterior
R=4.2 680.00 ft-
b. Concrete Block - Int Insul, Exterior
R=13.0 612.00 ft
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=11.0 240.00 ft'
4. Number of Bedrooms 4
d. NIA
R= ft'
10. Ceiling Types (1686.0 sqft.)
Insulation Area
5. Is this a worst rase? No
a. Under Attic (Vented)
R=30.0 1686.00 ft
6. Conditioned floor area above grade (ft') 1686
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
cDucct
R _ .
11
R ft'
7. Windows(182.5 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 131
a. U-Factor. Sgl, U=0.49 99.89 ft'
SHGC: SHGC=0.24
b. U-Factor. Sgl, U=0.58 53.33 ft'
12. Cooling systems
kBtu/hr Efficiency
. SHGC: SHGC=0.25
a. Central Unit
34.2 SEER:14.50
c. U-Factor Sgl, U=0.55 22.39 ft'
SHGC: SHGC=0.22
13. Heating systems
kBtulhr Efficiency
d. U-Factor. other (see details) 6.85 ft-
a. Electric Heat Pump
33.8 HSPF:8.20
SHGC: other (see details)
Area Weighted Average Overhang Depth: 4.933 ft.
Area Weighted Average SHGC: 0.240
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types ( 1686.0 sgft.) Insulation Area
EF: 0.820
a. Slab -On -Grade Edge Insulation R=0.0 1686.00 ft-
b. Conservation features
b. NIA R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.108 Total Proposed Modified Loads: 52.57
PASS
Total Baseline Loads: 56.84
f�M�7
1 hereby certify that the plans and specifications cc ere d by
Review of the plans and
4g11E S?41 "
this calculation are in compliance ith the Florida ergy
specifications coveredby this
Code.
calculation indicates compliance
with the Florida Energy Code.�rrn,•••:
PREPARED BY-.
Before construction is completed
m
DATE:
this building will be Inspected for
compliance with Section 553.908
c�7 1j'• ,�
4m
, `�•' ° c
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Col m•
GOp WE•ci°
�1rm J-kBUILDING
OWNER/AGENT:_l
OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -seated in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
3/1712020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
PUT SUMMARY CHECKLIST REPORT
FOKM K4U5-2017
IN
PROJECT
Title:
RENAR BERMUDA 1686 Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 1686
Lot # 40
Owner Name:
FERRUCCI
Total Stories: 1
Block/Subdivision:
*# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
RENAR HOMES
Rotate Angle: 270
Street
County: St. Lucie
Permit Office:
FT PIERCE
Cross Ventilation:
Jurisdiction:
661100
Whole House Fan:
City, State, Zip: FT PIERCE ,
FL,
Family Type:
Single-family
New/E)dsting:
Now ,(From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO BEACH MUNI 39 90
70
76 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1688 13488
SPACES
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled- Heated
,Number
1
Main
1686 13488 Yes 8
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 162 ft 0
1686 ft'
-- 0 0 1
ROOF
Roof Gable Roof
Red
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
#
Type
Materials Area Area Color
Barr
1
Gable or shed Composition shingles 1826 ft' 350 ft' Light
N
0.96 No 0.9 No 0 22.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1686 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area, Framing Fran Truss Type
1
Under Attic (Vented)
Main 30 Blown
1686 ft' 0.11 Wood
3/17/202010:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar Below
Space
P
n
ArPP
R-1/21rre
F
u
1
N=>W Exterior
Concrete Block -Int Insul
Main
4.2 38
8
304.0 ft'
0
0.3
0
_ 2
E=>N Exterior
Concrete Block - Int Insul
Main
4.2 47
8
376.0 ft'
0
0.3
0
_ 3
S=>E Exterior
Concrete Block - Int Insul
Main
13 16
6
8
132.0 ft'
0
0
0.3
0-
-4
W=>S Exterior
Concrete Block - Int Insul
Main
13 60
8
480.0 ft'
0
0
0.3
0
_ 5
S=>E Garage
Frame - Wood
Main
11 19
8
152.0 ft2
0
0.5
0.3
0
6
W=>S Garage
Frame - Wood
Main
11 11
8
88.0 ft'
0
0.5
0.3
0
DOORS
# Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 E=>N Insulated
Main
None
.46
3
6 8
20 ft'
WINDOWS
Orientation shown is the entered orientation =>) changed to As Built rotated 270.degrees).g
Wall
Overhang
V
# Omt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
_
1 N=>W 1
Metal Single (Tinted)
Yes
0.58 0.25
N
53.3 ft-
14 ft 0 in
0 ft 1 in
None
None
2 N=>W 1
Metal Single (Tinted)
Yes
0.49 0.24
N
15.5 ft'
1 ft 4 in
0 ft 6 in
None
None
3 N=>W 1
Metal Single (Tinted)
Yes
0.49 0.24
N
15.5 ft'
1 ft 4 in
0 ft 6 In
None
None
4 E=>N 2
Metal Single (Tinted)
Yes
0.49 0.24
N
15.5 ft'
1 ft 4 in
0 ft 6In
None
None
5 E=>N 2
Metal Single (Tinted)
Yes
0.49 0.24
N
15.5 ft-
1 ft 4 in
0 ft 6 in
None
None
6 S=>E 3
Metal Single (Tinted)
Yes
0.47 0.24
N
2.9 ft'
4 ft 6 in
0 ft 1 in
None
None
7 S=>E 3
Metal Single (Tinted)
Yes
0.49 0.24
N
16.5 ft'
0 ft 8 in
5 ft 0 in
None
None
8 S=>E 3
Metal Single (Tinted)
Yes
0.49 0.24
N
11.2 ft'
0 ft 8 in
4 ft 6 in
None
None
9 S=>E 3
Metal Single (Tinted)
Yes
0.47 0.24
N
4.0 ft'
0 ft 8 in
4 ft 0 in
None
None
10 S=>E 3
Metal Single (Tinted)
Yes
0.49 0.24
N
11.2 ft'
0 ft 8 in
4 ft 6 in
None
None
11 W=>S 4
Metal Single (Tinted)
Yes
0.55 0.22
N
22.4 ft'
1 ft 4 in
2 ft 0 in
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 440 fN 440 ft'
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA
EgtA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1573.6 86.39
162.47
.1233
7
311712020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
uuw w r•v ^U=^ 71 ICT DCDf%DT
FORM R405-2017 lrvru 1 QUIVI M • yr Ia.v..�.v. •-
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
None Sing! HSPF:8.2 33.8.kBtulhr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency Capacity
Air Flow SHR
Block
Ducts
1 Central Unit(
None Singl SEER: 14.534.2 kBlufir
1026 cfm 0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location EF Cap Use
SelPnt Conservation
1 Electric None
Garage 0.92 40 gal 60 gal 120 deg
None
SOLAR HOT WATER SYSTEM.
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume.
FEF
None None
ft
DUCTS
— Supply—
— Return — Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location Area Leakage Type Handler
TOT OUT QN
RLF
Heat Cool
1 Attic 6 131 ft'
Attic 54 ft' Default Leakage Garage.
(Default) (Default)
1 1 _.
TEMPERATURES
Progmmabl(e Thermostar[t:'jY
Ceiling Fans:
r[7c�,]
Heating [X] Jan Feb Mar
IX� [ ]
Jun E) Jul EX) AuDec
g
�C��Api
�X] ]
E ]Sep L.1 Octi
NOV
fD0'
Dec
L><1
Venting [ Jan [[[ 1)11 Feb [((�XX])) Mar
L 1
[ May lxl Jun ) Jul ) Aug
) Sep lxl
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3 4 5 6 7
8 9 10
11
12
Cooling (IND) AM 78
78 78 78 78 78 78
78 78
78. 80 60
78 78 78
80
78
80
78
PM 80
80 78 78 78
Cooling (WEH) PM 78
78 78 78 78 78 78
78 78 78
78
78
Heating (WD)
66
68 68
68 68 68
68 68 68
66
66
PM 68
68 68 68 68
Healing (WEH) PM 68
68 66
68 68 68
68 68 68
66
66
68 68
MECHANICAL VENTILATION
Type Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
None 0
0 0 - 0 1 - Electric Heat Pump
0% 1 -Central Unit
MASS
Mass Type
Area Thickness Furniture Fraction Space
'
Default Bibs/s .ft.
0 ft2 Oft 0.3
Main
31171202010:14 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED,ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Retum ducts R
6.0
c) AHU location Garage
3. No. of units (if multipfe-family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
34.2
a) Split system SEER
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground(water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1686
d) Room unit/PTAC EER
e) Other
14.6
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.523
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.240
14. Heating system: Capacity
33.8
c) Area
7c. 182.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(wetghted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
0 Other
8.20
9. Floor type, insulation level:
'
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
go.
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior.
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
1 OA1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. varies
f) Heat recovery unit HeatReC%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 11.0
2. Masonry (Insulation R-value)
1OB2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
A) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Date:
Address of New Home:
City/FL Zip: FT PIERCE. FL
3/17/2020 10:14:32 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERf Metnoos
ADDRESS: Permit Number:
FT PIERCE, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
F
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed, and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelopeshallbe constructed to limit air leakage In accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveloyhe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation.The components of the building theme[ envelope as fisted in Table R402.4.1.1 shall be Installed in accordance
with the manufacturers instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall Inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through S. Testing shall be conducted in
accordance with ANSIIRESNE ACC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined In Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (1) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exteriorwindows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if Installed at the time of the lest, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doom on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air IeakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Uslm2), and swinging doors no more than 0.5 cfm per square foot (2.6 Uslm2), when tested according to NFRC 400 or
AAMAI WDMAICSA 101II.S.21A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
3/17/2020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY -REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope.. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated In accordance with Section R403. The combustion air duct shall be Insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cm (0.944 Vs) when tested in accordance with ASTM E283 a1 a.1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
1.
2.
SECTION R403 SYSTEMS
R403.1 Controls.
[-IR403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heal pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operationwhen the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct lightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNETIICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0. (g) or (I), Florida Statutes, to be °substantially leak free' In
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the lest. All registers shall be taped or otherwise sealed during the test.
2. Postconstructlon test: Total leakageshall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 406 of this code.
A written report of the results of the test shall be signed by the parry conducting the test and provided to the code official.
❑R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑R403.4 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41'C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping Insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shieldingfrom solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance.with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot waterwithin the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping In accordance
with the times when heated water is used in the occupancy.
3/17/2020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.6 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps. and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps. shall consist of either a commercially available heat Gap or a
downward and upward bend of at least 3'% inches (89 mm) in the hot water distribution line and cold water line located as close as possible
tothe storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60"C).
R403.5.6.1.2 Shut down. A separate switch or a clearly markedcircuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment Installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solarwater heaters shall meet the criteria of Section R403.5.6.2.1.
El R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
.Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system Is not operating.
❑ R403.6.1 Whole-housemechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans. shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings In ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
rrawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be'
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
Indoor units (if split system) shall be submitted along with thesensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shelf not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment. is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
3/17/2020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that Its total capacity Is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturers product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -lest value and shall not be used for equipment sizing. Manufacturers
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature forwater-source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be forthe Indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return ducts) Is Installed in an unconditioned space.
Exceptions:
1. Attached single. and multiple -family residential equipment sizing maybe selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design healing load is 1.15 times greaterthan the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building.
shall Include automatic controls capable of shutting off the system when the pavement temperature is above 50'F (10'C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker forthe
power to the healer. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
❑ the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
3/17/2020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters.. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Tablet, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory Is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatory0he energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-t 4.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). . Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
3117/2020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: RENAR BERMUDA 1686 Builder Name: RENAR HOMES
Street: Permit Office: FT PIERCE
City, State, Zip: FT PIERCE. FL, Permit Number.
U
m
Owner. FERRUCCI Jurisdiction: 661100
U
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION•CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable Insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceilinglsoffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed,
shall be aligned with the air baffler.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
Walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope insulation for framed.
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be Installed at any exposed edge. of
Floor framing cavity insulation shall be installed to
(including
Insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking; or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided Instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned spare shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
Narrow cavities
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed fighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterlorwalls, or insulation that on
installation readily conforms to available space shall
extend behind Diolno and wirind.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be Insulated.
Electricalfphone box or
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or callings
I
a. In addition, inspection of log walls shall be In accordance wan the provisions or IGG-4uu.
3/17/2020 10:14 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
qn17 Flnrida Building Code. Energy Conservation, 6th Edition
Jurisdiction: 661100
Permit*
1•yJ..
Y](Y
__ - 7 ,.-
Job,lnformatton r • '+
,
Builder: RENAR HOMES Community: Lot: NA
Address:
City: FT PIERCE State: FL Zip:
aAtrLeakageTestResults Passmgresultsmustme`eteYflierfhPerformance'Prescnphve orERlMefhodM�
777,
�SCRIPTNEMETHOD�fh'e,buildmgordwelling)unRshall bedestedand renfied as hav�mg�an_art }eakage rate of not exeeedmg7 au
„O�
etiangesryer'hotir aCa+pressure of 0 2 Inch'w g (50 Pascals) m Climate Zanes t4and�2 . <,,: � I x � . a
'.. ,t M ,
dvlling�umt tested and venfieas having an atr5leak%I^. ga;' rate ofnotexceedingn
r 03 P,ERFORMAN6E onERhMETHOD-Theibwldingcr shal;be
the selected�ACH(50)�value as sho mson FortnµR405�2017(PerFormariceoF;406-201,,7L(ERI) secbonrlabeled as?infiltratian;:suli=secbon ACHSOs
nrForm`�'RdOS E�01`i`Fr'iey Cafc�(Perlo}rmancej:or R40E20i7(ERI) .,. J000
sic.„',.�`�{+r'.9CH(�O)apld
x 60 + 13488 = Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
❑ PASS ® Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402A.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 Inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(0. (9), or (I) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers Including exhaust, Intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond Intended infiltration control
measures.
3. Interior doors, If Installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if Installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
3/1712020 10:14:35 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC sib Edition (2017) Compliant Software Page 1 of 1
Renar Homes Bermuda 1686
HVAC Load Calculations
for
Renar Homes
TXT7VAC, HV'AG Loans
Prepared By:
Preferred Air Conditioning & Mechanical
1643 Donna Road
West Palm Beach, FI. 33409
561-689-1093
Tuesday, February 04, 2020
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
rtnrac•nemaeenm augnc yommerc�arnvgv coats - Ehta$OfIVYa[e DeY010prRe0t,'Ipc:..
preferred'/Lr Condihor lhg & Mech enar Homes Bermutla 1686'lI
West PalniB�ech. PL'+33409' - _ - ,J.,.. _ -
I EauiDment Data - Svstem 9 - Ac - 1
Cooling
System Type:
Outdoor Model:
Indoor Model:
Tradename:
Outdoor Manufacturer:
AHRI Reference No.:
Capacity:
Efficiency:
Heating
System Type:
Model:
Tradename:
Manufacturer:
Description:
Capacity:
Efficiency:
Standard Air Conditioner
CA16NA036'0•`A•
FX4DN(B,F)049L
16 SEER AC
CARRIER
9199273
35,200
16 SEER
Electric Resistance
CARRIER AIR CONDITIONING
CARRIER AIR CONDITIONING
33,800
0%
This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain:
19,591 Btuh, Lat. gain: 13,352.Btuh, Sen. loss: 30,200 Btuh, Entering clg. coil DB: 79.7F, Entering clg. coil WB: 67.7F,
Entering htg, coil DB: 50.8F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 722 CFM, Req, htg. airflow. 307 CFM
C:1... \RENAR BURMUDA 1674.rh9 Tuesday, February 04, 2020, 3:00 PM
.. Elites SoiMare Development, Ina
Rhvac-Resrdentlal & LigM Commercial tiMA6ioads .. Rener Homes Bermuda 1686
Preferred ArrCohditioning BMech.:
,. .. ..
Page 3
West Palm Ilea FL 33409
System 9 Room Load SUMMafYclg.
Htg Nf1rF Run Rritl Clg Min
D�rct Duet Sens. �. Lest, .. Cig
Sys
:. •;.,... •
Room Flea �e�rs CFNF.
. , :.: Vei r .:: 9iuh .: Btuh CFM
CFM
No Name-,'.,.: :._..SF_:;:.
Htuh�. ,...-Size
-Zone 1-
P86 4,410 57
1-9 496 4,818 249 219
219
178
1 Family
2 Kitchen
288 2,054 27
1-8 510 3,912 1,380 178
3,211 249 146
146
3 Dining
169 4,943 64
4
1-7 547
1-4 147 281 249 13
13
4 Master Bath
98 307
228 3,044 40
1-8 528 4,052 691 184
184
5 Master Bedroom
35 1,173 15
1-4 185 355 208 16
16
6 Wic 1
7 Bedroom 2
130 3,767 49
1-7 455 2,674 408 122
208 46
122
46
8 Laundry
72 845 11
1-4 529 1,015
1-4 98 188 208 9
9
-9 Bath 2
56 230 3.
130 1,307 17
1-6 580 2,504 408 114
114
10 Bedroom 3
35 1,226 16
1-4 622 1,193 208 54
54
11 Wic2
25 646 8
1-4 131 252 208 11
11
12 Wic3
13. Master Commode
18 226 3
1-4 73 141 249 6
6
Ventilation
6,462
3,462 8,716
17
36
Duct Latent
85
251 9
_
Return Duct
System 1 total
1,572 30,725 314
28,308 14,048 1,119
1,119
System 1 Main Trunk Size:
12x18 in.
Velocity:.
839- ft./min-
_ 0 105 In wg
Loss per 100 ft.:
_
Coo-ietaStmam '�� -` �`•�.0 ,Y ti :" �s�� �,�` s» �i
PR,..vr'uv�P_o
'�i.�=`';��'•t-,,.`"'
^�, ex�s . .-.�iafeE?€r I r
'.. Sr'ne_�z- •'B{t�tFi•..,.. _
T-o',�al
Btuh
Net Required.
.
2.75 59%01.41%
_ .
19,591 13,352
32,943
Actual:
2.93• :Y5%'/•25°/a
26,400 8,800
35,200
Equipfftent`Aa"ta; ' - - -^„ £,� �� ,, ,, . _ •._ .::c �.:
�
Heating SVstem'
Cooling System
Type:
Electric Resistance
Standard Air Conditioner
Model:
CA16NA036*0'"jV
Indoor Model:
FX4DN(B,F)049L
Brand:
CARRIER AIR CONDITIONING 16SEER AC
Description:
Efficiency'.
0%
16 SEER
Sound:
0
0
Capacity:
33,800 Stuh
35,200 Btuh
Sensible Capacity:
We
26,400 Btuh
Latent Capacity:
n/a
8,800 Btuh
AHRI Reference No.:
n/a
9199273
This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWS: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDE: 70F, Sen.
gain:
28,308 Btuh, Let. gain: 14,048
Btuh, Sen. loss: 30,725 Btuh,
Entering clg. coil DB: 78.1 F, Entering cig. coil WB: 65.917,
Entering htg, coil DB: 51.217, CIg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1119 CFM, Req. htg. airflow: 314 CFM
CA -ARENAR BURMUDA 1674.rh9 Tuesday, February 04, 2020, 2:55 PM