HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYi�Ip�E THE INDSORIMPACT
Street: ^.G. '/
Builder Name: WYNNE DEVELOPMENT
PermitOfBce: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number.,
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zane 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1432.0 sqft.)
Insulation , Area
2. Single family or multiple family Single-family
a.'Concrete Block- Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3., Number of units, if multiple family 1
c. N/A
R= ft2
4., Number of Bedrooms 3
d. WA
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1783.0 sgft.)
Insulation Area.
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned Floor area above grade (ft2) 1753
b. Knee. Wall (Vented)
R=19.0 30.o0 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(151 A sgft.) Description Area -
a: Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl,U=liO4 111.36ft2
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBlu/hr Efficiency
d. U-Factor. WA 112
a.. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1763.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None.
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed. Modified Loads: 52.20
PASS
Total Baseline Loads: 53.92
hereby certify that the plans and specifications covered by
Review of the plans and
O f"E52,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
'
with the Florida Energy Code.
OWNER/AG�IT: ���
BUILDING OFFICIAL:
DATE: `\
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factoryseale l in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
REVIEWED FOR
C®®RUC E iC® NTY
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Softwan OCCy Pagel of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP
Bedrooms: 3
Address Type:.
Street Address
Building Type: User
Conditioned Area: 1753
Lot#
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: -0
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree. Days Moisture
Range
FL, Fort Pierce FL_VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1753
14024
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished, Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M. BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREATR 588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209
1672 Yes
0'
1
Yes
Yes
Yes
9 BATH 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3 169
1352 . No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER
BEDRO 37 ft 0
224 ft'
_
0 1
0
2Slab-On-Grade Edge lnsulatio WIC 1 ft 0
63 ft'
__
0 1
0
3 Slab -On -Grade Edge lnsulatio MASTER BATH 8 ft 0
561N
0 .1
0
4 Slab -On -Grade Edgeinsulatio M. BATH 7 ft 0
61 ft'
_
0 1
0
SSiab-On-Grade Edge lnsulatio LAUDRY 1 ft 0
36 ft'
_
0 1
0
1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT. SUMMARY. CHECKLIST REPORT
FLOORS
# Floor Type
Space PerimeterPedmeterR-Value
Area
Joist R-Value
Tile Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft'
_
0 1
0
7SIab-On-Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft'
0 1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft'
0 1
0
9 Slab -On -Grade Edge Insulatio
BATH Sit
0
50 ft'
0 1
0
10Slab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft°
_
0 1
0
118Iab-On-Grade Edge Insulatio
FOYER 911
0
92 ft'
0 1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft'
__
0 1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emilt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1847 ft'
0 ft'
Light
N
0.4
No 0.9
No . 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft
N
N
CEILING
# Ceiling Type
Space
R-Value'
. Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft'
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft'
0.1
Wood
_
4 Under Attic (Vented)
M. BATH
3D
Blown
61 ft'
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft'
0.1
Wood
_ 6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft'
0.1
Wood
_ 7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft'
0.1
Wood
_ 8 Under Attic (Vented)
KITCHEN
30
Blown
209ft'
0.1
Wood
9 Under Attic(Vented)
BATH
30
Blown
50 ft'
0.1
Wood
la Under Attic (Vented)
HALL
30
Blown
25 ft'
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft'
0.1
Wood
_ 12 Under Attic (Vented)
BEDROOMS
30
Blown
169ft
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT'
19
.Blown
30 ft'
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
SheathingFraming Solar
Below
1 E -Exterior Concrete Block- Int lns01ASTER BE 4.1 16
0 8
0
128.0 ft'
0
0 0.3
0
_ 2 W Fxdedor Concrete Block-. Int Ins6JASTER BE 4.1 7
0 8
0
56.0 ft'
0
0 0.3
0
3 S Exterior Concrete Block- Int InsWASTER BE 4.1 14
0 a
0
112.0 fF
0
0 0.3
0
1/8/2020 4:43 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Coinpliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar Below
-4
E
Exterior
Concrete Block - Int InsNASTER BA
4.1 8
0
8 0
64.0 iN
0
0
0.3
0
5
E
Exterior
Concrete Block- Int Insul M. BATH
4.1 7
0
8 0
56.0 ft'
0
0
0.3
0
-6
E
Exterior
Concrete Block- Int InsBlEDROOM 2
4.1 12
0
8 0
96.0 ft'
0
0
0.3
0
_7
S
Exterior
Concrete Block- Int lnsllINING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
_ 8
W
Exterior
Concrete Block- Int InsGIINING/GRE
4.1 20
0
8 0
160.0 ft'
0
0
0.3
0
_ 9
W
Exterior
Concrete Block - Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.3
0
10
E
Exterior
Concrete Block- Int Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
_ 11
N
Exterior
Concrete Block - Int Insul FOYER
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
_ 12
N
Exterior
Concrete Block - Int Insul FOYER
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
_ 13
W
Exterior
Concrete Block- Int InsSEDROOM 3
4.1 13
0
8 0
104.0 ft'
0
0
0.3
0
_ 14
N
Exterior
Concrete Block- Int InsSEDR00M 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
15
N
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft'
023
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
-
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
_
1
S 3
Metal Low-E Single Yes
1.04 0.29
N
32.4 ft'
1 ft 0 in
1 ft 51n
Drapes/blinds
Exterior 5
2
E 5
Metal Low-E Single Yes
1.04 0.29
N
6.9 ft'
1 ft o In
1 ft 5 in
None
None
_
3
E 6
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft'
1 ft 0 in
1 ft 5 in
None
None
_
4
S 7
Metal Low-E Single Yes
1.04 0.29
N
39.8 ft'
1 ft 0 in
1 It 5 in
None
None
_
5
W 8
Metal Low-E Single Yes
1.11 0.27
N
40.0 ft'
8 It 0 in
1 It 5 in
None
None
6
W 13
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 It 0 in
1 ft 5In
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area ExposedWall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254 1168.7 64.16
120.66
.0881
5
1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 34.8 kStu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singi SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM -
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
-- Supply —
— Return — Air
CFM 25
CFM25
HVAC #
i/ # Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic 6 175 ft2
Attic
55 ft2 Default Leakage Attic
(Default) (Default)
1 1
TEMPERATURES
Programablfe'Thermostatt:']Y
Ceiling Fans:
r'
Heating Jan Feb [Xt Mar
[ ]
L JApr
May.IX IX
May Jrl un [ Jul [ Aug
IX
[ � Sep
[ ]
L.l
Dec
�00)
Venting [ ]Jan f ]Feb [x] Mar
l l I 1
lxl [
Jun f Jul [ Aug'
[ Sep
lxl OctX
Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6 7
8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78 78
78
80
80
80
80
PM 80
80 78
78 78 78 78
78
78
78
78
78
Cooling (WEH) AM 78.
78 78
78 78 78 78
78
78
78
78
78
PM 78
78 78
78 78 78 78
78
78
78
78
78
Healing (WD) AM 66
66 66
66 66 68 68
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
66
66
Heating(WEH) AM 66
66 66
66 66 68 68
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft 0.3
BEDROOM
Default(8 lbs/sq.fL
ft2
ft 0.3
WIC
Default(8lbs/sq.ft,
ft2
ft 0.3
M. BATH
-
Default(8 ibs/sq.ft.
112
ft 0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft 0.3
BATH
Default(81bs/sq.fL
ft2
i2 0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft 0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft 0.3
LAUNDRY
1/8/2020 4:43 PM. EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
MASS
1 Mass Tvoe Area Thickness Furniture Fraction Soars 1
118/2020 4:43 PM EnergyGauge® USA 6.0.02(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2617 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR.IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner. Jurisdiction:
w
2
Design Location: FL, Fort Pierce
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air harder in any dropped ceilinglsoffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
-Cavities within comers and headers of frame walls
The junction of the top plate and the lop of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
'
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be. installed at any exposed edge of
Floor framing cavity Insulation shall be Installed to
(including
insulation.
.maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be In contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, Insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts In narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation,
Air seating shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing In exterior walls, or Insulation that on
installation readily conforms to available space shall
extend behind ninino and WrIno.
Showerttub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barriershall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that Is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover niates and walls or ceilinas.
a. In aaanlon, inspection or log watts snail tie In accordance wim the provisions or ICC-400.
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12, Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts
R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system:
Capacity
34.8
a) Split system
SEER
15.0
5. is this a worst case? (yes/no)
5.
Yes
b) Single package
SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system:
Capacity
34.8
c) Area
7c.
151.4
a) Split system heat pump
HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance
COP
a) U-fector:(weighted average)
Be.
NA
d) Gas furnace, natural gas
AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG
AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior.
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.97
b), Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%a
g) Other
10B1.
11.0
10B2.
16. HVAC credits claimed (Performance. Method)
a) Ceiling fans
11a.
30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c..
19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: �� Date: \ `\
Address of New Home: (� \ City/FL Zip: FT. PIERCE. FL�_
1/8/2020 4:43:52 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1