Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street (1 Q �S Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, �"+ Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1432.0 sgft.) Insulation Area 2. Single family or multiple famTy Single-family a. Concrete Block- Irm Insul, Exterior R=4.1 1224.00 ft• b. Frame - Wood, Adjacent R=11.0 208.00 ft- 3. Number of units, if multiple family 1 c. WA R= ft' 4.. Number of Bedrooms 3 d. WA R= ft' S. Is this a worst case? Yes 10. Ceiling Types (1783.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft' 6. Conditioned floor area above grade (ft� 1753 b. Knee Wall (Vented) R=19.0 30.00 ft. Conditioned floor area below grade (ft2) 0 c. N/A R= ft' 11. Ducts - R ft' 7. Wndows(151 A sgfL) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=1.04 111.36 ft' SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: WA ft' SHGC: 13. Heating systems kBWMr Efficiency d. U-Factor. WA ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sgfL) Insulation Area a. Electric Cap: 40.gallons a. Slab -On -Grade Edge Insulation R=0.0 1753:00 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20 PASS Total Baseline Loads: 53.92 I hereby certify that the plans and specifications covered by Review of the plans and O�ZS1�87q� . this calculation are incompliance with the Florida Energy specifications covered by this ' = g� aA Code. calculation indicates compliance ��yy 'P r/H = with the Florida Energy Code. r,;n •, yj �'� n �O PREPARED BY: A10pa Before construction is completed ' DATE: 1-9-20 this building will be inspected for compliance with Section 553.908 hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/ASa13NT:� -�-- BUILDING OFFICIAL: DATE: ��ZZ \�� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402A.1.2). REVIEWED FOR CODE COItC�M^^PLIAN,1 CE 1/812020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th F�It7�i{2Ll gg�tgnl4SaMra'J NTY Page t- of 6 ee�� BOCC FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBool : Builder Name: WYNNE DEVELOPMENT Rotate Angle: .0 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New1E)dsting: New (From Plans) , Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen . Occupants Bedrooms InfiLID Rnlshed Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GRFATR 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0. 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL '26 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 3711 0 224 ft' ---- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' _ 0 .1 0 3SIab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' _ 0 1 0 '4SIab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 ft' — 0 1 0 5 Slab -On -Grade Edge Insulation LAUDRY i ft 0 36 ft' 0 1 0 1/8/2020 4:43 PM EnergyGaugeS, USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT. SUMMARY. CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade EdgeInsulatio BEDROOM 2 12 ft 0 180 ft' — 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' _ 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft ,0 209 tt' — 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' _ 0 1 0 10Slab-On-Grade.Edge Insulatio HALL 1 it 0 25 ft' — 0 1. 0 118lab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft' _ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft' — 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emift Emilt Deck Pilch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft' 0 ft' ,Light N 0.4 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented .150 1753 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Venterl) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood _ 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 3D Blown 61 ft' 0.1 , Wood. 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2 30 - Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) - DINING/GREAT 30 Blown 588 ft' 0.1 Wood _ 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0:1 Wood _ 9 Under Attic (Vented) BATH 30 Blown 50ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Atic(Vented) FOYER 30 Blown 92 ft' 0.1 Wood _ 12 Under Attic (Vented) BEDROOM 3 - 30 Blown 169 ft' 0.1 Wood' 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block - Int InsNASTER BE 4.1 16 0 8 10 128.0 ft' 0 0 0.3 0 —2 W Exterior Concrete Block - Int Ins01ASTER BE 4.1 7 0 81 0 56.0 ft' 0 0 0.3 0 3 S Exterior Concrete Block - Int InsNASTER BE 4,1 14' _ 0 8 0 112.0 ft' 0 0 0.3 0 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software' Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below -4 E Exterior Concrete Block - Int InseIASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 -5 E Exterior Concrete Block- Int Insul M. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 -6 E Exterior Concrete Block - Int Ins®EDROOM 2 4.1 12 '0 8 0 96.0 ft' 0 0 0.3 0 -7 S Exterior Concrete Block- Int InsiDINING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.3 0 -8 W Exterior Concrete Block- Int InsdINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 _ 9 W Exterior Concrete Block - Int Insu1KITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 _ 10 E Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 _ 11 N Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 12 N Exterior Concrete Block - Int Insul FOYER 4.1 1 0 8 0 8.0 ft" 0 0 0.3 0 _ 13 W Exterior Concrete Block - Int InsBEDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 _ 14 N Exterior Concrete Block - Int Ins®EDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0.3 0 15 N Garage Frame -Wood BEDROOM 11 26 8 208.0 ft' 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 a 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 S 3 Metal • Low-E Single Yes .1.04 0.29� N 32.4 ft' 1 It 0 in 1 ft 5In Drapes/blinds Exterior 5 2 E 5 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft' 1 ft 01n 1 ft 5 in None None _ 3 E 6 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft' 1 ft 0 in 1 ft 5 in None None _ 4 S 7 Metal Low-E Single Yes 1.04 0.29 N 39.8 fl' 1 ft 0In 1 ft 5 in None None _ 5 W 8 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in None None 6 W 13 Metal Low-E Single Yes 1.64 0.29 N 16.2 ft' 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall. Height Exposed Wall Insulation 1 806 ft° 806 ft' 26 ft 8 R 11 INFILTRATION # Scope Method • . SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.16 120.65 .0881 5 1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed EfficiencyCapacity Block Ducts 1 Electric Heat Pump/ Split Sing) HSPF:8.5. 34.8 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central UnIV Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage . 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Can # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS Supply Return —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft' Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablree Thermostat:Y Crreiling Fans:Cooling . Jan Feb Venting Feb Mr MX Mar Apr Ma r0( ID0' ITXI� May Jun �AugX� NovSe Octr00'rI' ctt Oct Dec [ ]Jan [ ] [ [ [ ] Jul [ ] Aug Sep [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78' 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 - 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 1 WIC Default(8 lbs/sq.ft. 112 ft 0.3 M. BATH Default(8 lbslsq.ft. ft2 ft 0.3 KITCHEN Default(8 lbslsq.ft. ft2 ft 0.3 BATH Default(B lbs/sq.ft.. ft2 H 0.3 BEDROOM 2 Default(8lbslsq.ft. ft2 ft 0.3 ENTRY Default(8 lbslsq.ft. ft2 ft 0.3 LAUNDRY 1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02�(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARYCHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs/s .ft. ft' _ It . 0.3 GREAT/DINING 118/2020 4:43 PM EnergyGauge® USA 6.0.02(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: cYi Owner. Jurisdiction: W x Design Location: FL, Fort Pierce o COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Alr-permeable Insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the Insulation and any gaps In the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame wails The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per Inch minimum. Exterior thermal envelope -insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity Insulation shall be installed to (Including Insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut tofit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation, Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.' Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or Insulation that on installation readily conforms to available space shall extend behind pining and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barriershall be installed behind electrical or communication exterior walls boxesor air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers: shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprink er cover plates and walls or ceilings. uywuw m ,,,y wanes m ion ue m aucumenuc wall me provisions or ll lr uu. 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes . b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor.(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c, a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c).Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (insulation'R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat - Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:_ Date: Address of New Home: - \ �. ` ! X� �"S City/FL Zip: FT. PIERCE. FL 1/8/2020 4:43:52 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1