Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 .FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNIS THE VKINDSOR IMPACT Street:\ Builder Name: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City, Slate, Zip: T. PIERCE, L , Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. WA R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1783.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sgfL) Description Area a. Sup: Attic, Ret Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. WA ft2 SHGC: 13. Healing systems kBtu/hr .Efficiency d. U-Factor: N/A ft2 - a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. ' Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753:00 ft2 b. Conservation features EF: 0.970 b. NIA R= ft2 None c. NIA R= ft2 15. Credits Patel Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20 PASS Total Baseline Loads: 53.92 I hereby certify that the plans and specifications covered by Review of the plans and �TkiE57 this calculation are in compliance with the Florida Energy specifications covered by this N, Code. calculation indicates compliance with the Florida Energy Code. b. PREPARED BY: g��- �""` Before construction is completed T DATE: 1-9-2U this building will be inspected for compliance with Section 553.908 Yi r 9 y .. I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. CODWS ,Kg> OWNER/ �� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). sviEWED FOR LIANCE %ODLU IE COUNTY ST 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20 n ComplianBSGV Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/SubilMsion: # of Units: 1 Worst Case., Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County:. St. Lucie Jurisdiction: Whole House Fan: No City, State, Zlp: FT. PIERCE, Family Type: Single-family FL, New/EAsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume IGtchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDR00 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREATR 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes' Yes 9 BATH 50 400 No 0- 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' _ 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' — 0 1 0 3Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' 0 1 0 4SIab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 ft' — 0 1 0 5Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft- — 0 1 0 1/8/2020 4:43 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 -FORM R405-2017 INPUT -SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2, 12 ft 0 180 ft2 — 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 — 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 It 0 209 It' _ . 0 1 0 9 SIab-On-Grade Edge Insulat o BATH 5 ft 0 50 ft' _ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 _ 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 — 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 — 0 1 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Bart Absoc Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft' Light N 0.4 No 0.9 No 0 18.4 ATTIC. / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC - 1 Full attic Vented 150 1753 112 N N CEILING # Ceiling Type Space R-Value ' Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood _ 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood _ _ 4 Under Attic (Vented) M. BATH 3b Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2 30 Blown, 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209112 0.1 Wood _ 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood _ 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood _ 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 IF 0.1 Wood 13 Knee Wall (Vented) DININGIGREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Helght Sheathing Framing Solar Below _ 1 E Exterior Concrete Block- Int InsNASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 _ 2 W Exterior Concrete Block- Int Ins01ASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block- Int InSOEASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/8/2020 4'.43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY'CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below -4 E Exterior Concrete Block - Int InsNASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 -5 E Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 -6 E Exterior Concrete Block - Int InsHEDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.3 0 -7 S Exterior Concrete Block - Int Ins[iIINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 -8 W Exterior Concrete Block - Int Ins[IINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 _ 9 W Exterior Concrete Block - Int InsuIKITCHEN 4.1 11 0 8 0 88.0 fP 0 0 0.3 0 _ 10 E Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 112 0 0 0.3 0 11 N Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _ 12 N Exterior Concrete Block - Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _13 W Exterior Concrete Block - Int InsENEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 .0 _ 14 N Exterior Concrete Block - Int Ins1]EDR00M 3 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 15 N Garage Frame - Wood BEDROOM 3 11 26 - 8 208.0 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 '3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 S 3 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 E 5 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft2 1 ft 0In 1 ft 5 in None None _ 3 E 6 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft5 in None None _ 4 S 7 Metal Low-E Single Yes 1.04 0.29 N 39.8 V 1 ft 0 in 1 ft 51n None None _ 5 W 8 Metal Low-E Single Yes 1.11 0.27 N 40.0 112 8 ft 0 in 1 ft 5 in None None 6 W 13 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling. Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 808 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 • 1168.7 64.16 120.66 .0881 5 11812020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 -FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts _ 1 Electric Heat Pump/ Split Singi HSPF:8.5 34.8 kBtu1hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM - FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / — Supply — — Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre TJhermostar[t:'Y Ceiling Fans: Heating Jan Feb r(�X],� Mar [ ] L Jr �0 Jun ( ] Jul IX (i Aug lXI [ ] Sep [ j 11 lr�� Dec f0C'I Ventlng [) Jan [ 1 Feb L 1 l l !R) Mar Ixl lxJ [ May Jun [) Jul [ Aug [)Sep lxl Oct '[X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference - Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 -78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78" 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(B lbs/sq.ft. 0 ft' Oft 0.3 BEDROOM Default(8 lbs/sq.ft. fF It 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(81bs/sq.ft. it. ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' it 0.3 BATH Default(8 lbs/sq.ft. ft' d 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft' ft 0.3 ENTRY Default(S Ibs/sq.ft. ft' ft 0.3 LAUNDRY 1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 MASS 1 ' Mass Tvpe Area Thickness Furniture Fraction Soace 1 1/8/2020 4:43 PM EnergyGauge® USA6.0.02 (Rev.1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, Stale, Zip: FT. PIERCE, FL, Permit Number. U Owner. Jurisdiction: w Design Location: FL, Fort Pierce X COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains continuous air barrier, not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps In the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelopeinsulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,JcaAty a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the cravd Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut tofit, o Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the availabl spaces. Garage separation, Air sealing shall be provided between the garage and conditioned spac Bs. Recessed fighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed In the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.' Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninfing and wirlino. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be I sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sorinkler cc s and walls or ceilings, I a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGYPERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location $ insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation. No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based d c�compliia^nt features. Builder Signature: / - Date: Address of New Home: �V��\ City/FL Zip: FT. PIERCE, FL-S`kci S 1/8/2020 4:43:52 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1