HomeMy WebLinkAboutEngineeringForensic Engineering Consultants, Inc. Project Name Project Address Deck Substrate Configuration Category Exposure Condition Building Type Base Wind Speed Slope V WOOD SHAKE ATTACHMENT CALCULATIONS Bryn Mawr Ocean Towers - Clubhouse 5061 North A-1-A Ft. Pierce, FL - 34949 Wood Non -Insulated Steep Slope II D Enclosed 170 mph Uplift Pressures q= qZ KZ 65.097 1.030 Field P1 A Perimeter P2 W. Corner P3 ui,, Proposed System Product Approval No. Wood Shake Dimensions Fasteners 5.0 Slope H 0.00256 KZ Kr Kd V2 Report No.: ATRT-WS-20.001 Mean Roof Height 12.9 Feet Roof Area (Approx.) 3366 Sq.Ft. Roof Width 51.0 Feet Perimeter Width 5.1 Feet Parapet Height 0.0 Feet Sloped Roof Type 12.0 Slope Angle* 22.62 P = qZ (GCP - GCP1) Kn Kd V GCP GCPi 1.005 0.85 170 -0.90 0.18 Field -1.70 0.18 Perimeter -2.60 0.18 Corner -70.30 psf PI sod 42.18 psf -122.38 psf P2 sod -73.43 psf -180.97 psf P3 sod-108.58 psf Copper Ridge Shake & Shingle - Wood Shake (Hand Split Shakes) 17-0614.22 14" x 24" Panel Area 2.34 Sq. Ft. Stainless Steel Ring Shank Nails (2 per Shake) Field Perlmeter/Corner System Design Pressure psf psf Min. Fasteners per Shake 2 2 Min. Characteristic Resistance Force-170.00 Ibf (From NOA)-170.00 Ibf (From NOA) No. of Fasteners Required NF = (Wood Shake Area x PI) / MCRF Fastener Requirement RECOMMENDED WOOD SHAKE FASTENING Field Perimeter Corner 0.58 1.01 1.49 Field 2 Stainless Steel Ring Shank Nails per Wood Shake Perimeter 2 Stainless Steel Ring Shank Nails per Wood Shake Corner 2 Stainless Steel Ring Shank Nails per Wood Shake These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations, Ensure that roof system meets all the drainage, insulation and fire rating requirements of FBC, before installation, Sincerely Forensic Engineering Consultants, Inc. Ve.A.)l %o R. N. Sailapp an P.E. Principal Engineer Florida Registration No. 46696 Forensic Engineering Consultants, Inc. (CA #8265), P.O. Box 970034, Boca Raton, FL - 33497 Ph (561) 9018490 Fax (561) 218 3830