Loading...
HomeMy WebLinkAboutMorris attic breeze FBC_20200507160956Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG... Business & Professional Regulation l*r SCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats & Facts I Publications I Contact Us r BCIS Site Map I Links I Search n Product Approval USER: Public User Product Approval Ment > Product or Applkatlon Search > Appjotk n t kt > Application Detail FL * FL13339-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Attic Breeze Address/Phone/Email 1370 FM 116 Gatesville, TX 76528 (254) 865-9999 travis.hipp@atticbreeze.net Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Travis Hipp Address/Phone/Email 1370 FM 116 Gatesville, TX 76528 (877)288-4234 travis.hipp@atticbreeze.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed James L. Buckner, P.E. @ CBUCK Engineering the Evaluation Report Florida License PE -31242 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/01/2029 Validated By Michael John Riemer, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL13339_R6_COI_COI CertOf Indep James Buckner.P.E, se.PDF Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 1 of 3 4/30/2020, 2:41 PM Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wG... Method 2 Option B 01/05/2018 01/05/2018 01/10/2018 04/10/2018 FL # Model, Number or Name Description 13339.1 01—Solar Attic Fan Models AB -201A, AB -202A, AB -251A, AB -252A, AB -2022A, AB -3022A & AB -4022A. Self -flashing, solar powered fan units, with solar panel directly attached to fan unit shroud/dome Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339_R6_II_1_7_Attic Breeze-SPAF Panel Direct to Flush Mount Unit_EvalReport,pdf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. Design Pressure: +115/-115 #31242 Other: Refer to evaluation report for limitations and Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339_R6_AE_11=7 Attic Breeze-SPAF Panel Direct to_FIWsh Mount Unit _EvalReport.pdf Created by Independent Third Party: Yes 13339.2 02—Solar Attic Fan Models AB -201D, AB -202D, AB -251D, AB -252D, AB -401, AB -402, AB -2022D, AB -3022D & AB -4022D. Self -flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using low profile mounting brackets Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339_R6_II_2_7_Attig Breeze-SPAF Panel Remote to Low Approved for use outside HVHZ: Yes Profile_EvalReport.pdf Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. Design Pressure: +115/-115 #31242 Other: Refer to evaluation report for limitations and Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339_R6_AE_2_7 Attic Breeze-SPAF Pg_nel.Rgrnote to Low Profile_EvalReport.pdf Created by Independent Third Party: Yes 13339.3 03_Solar Attic Fan Models AB -201D, AB -202D, AB -251D, AB -252D, AB -401, AB -402, AB -2022D, AB -3022D & AB -4022D. Self -flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using universal mounting bracket Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339_R6_II_3-7_Attic Breeze-SPAF Panel Remote Approved for use outside HVHZ: Yes Inclined_EvalReport.pdf Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. Design Pressure: +115/-115 #31242 Other: Refer to evaluation report for limitations and Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339_R6_AE_3-7 Attic BreQ PAF eaDelrRem_o�e Inclined _EvalReport.pdf Created by Independent Third Party: Yes 13339.4 04—Solar Attic Fan Models AB -601, AB -602 & AB -6022D. Self -flashing, solar powered fan units, with solar panel remotely attached from fan unit, using low profile mounting brackets Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339_R6_II_4-7_AtticSre $e-52AF__pjpneLR-mote.ta_Low Approved for use outside HVHZ: Yes Profile_EvalRepart.pdf Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. Design Pressure: +115/-115 #31242 Other: Refer to evaluation report for limitations and Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339_R6_AE_4=7_Attic Breeze-SPAF Panel Remote to Low Profile_EvalReport.pdf Created by Independent Third Party: Yes 13339.5 05 Solar Attic Fan Models AB -601, AB -602 & AB -6022D. Self -flashing, solar powered fan units, with solar panel remotely attached from fan unit, using universal mounting brackets 2 of 3 4/30/2020, 2:41 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr—app_dti.aspx?param=wG.., Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339_R6_II_5 7 Attic Breeze -$PAF Panel Remote Approved for use outside HVHZ: Yes Inclined_EvalReport.pdf Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. Design Pressure: +115/-115 #31242 Other: Refer to evaluation report for limitations and Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339_R6_AE_5-7_Attl�: Breeze -PAF Panel Remote Ind ined_EvalReport. pdf Created by Independent Third Party: Yes 13339.6 06—Cardinal Ventilation Models CV -2000 & CV -3000. Self -flashing, circular shaped solar powered fan units, with solar panel directly attached to fan unit hood/dome Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339_R6_II_6=77_AB-Cardinal.SPAF Panel Direct t4, FI_Vsh Approved for use outside HVHZ: Yes Mount Unit _EvalReport,pdf Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. Design Pressure: +115/-115 #31242 Other: Refer to evaluation report for limitations and Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide, FL13339_R6_AE_6-7 AB^Cardtnai_SPAF Panel direct to Flush Mount Unit _EvalReport.pdf Created by Independent Third Party: Yes 13339.7 Curb Mount Series Curb Profile vent fan base for attachment to roof curbs Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339_R6_II_77=7 Curb -SPA -CM -ER W 10.pdf Approved for use outside HVHZ: Yes Verified By: James L Buckner, P.E. @CBUCK, Inc P.E. # Impact Resistant: No 31242 Design Pressure: +115/-115 Created by Independent Third Party: Yes Other: Refer to evaluation report for limitations and Evaluation Reports conditions of use. FL13339_R6_AE_7_7_ur' -S A:M:9R_W1j,,pdf Created by Independent Third Party: Yes Sack next Contact Us :: iiz1LA3.4�r.S[unel3aad, Tallahassee Fl. 32399 The State of Florida is an AA/EEO employer, CQRYIJ9hLZ4Q71 9.13_5Cai€aLFlaSld;3.:: Fihacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mailto this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine T you are a licensee under Chapter 455, F.S., please click here. Product Approval Accepts: M C1 ® _ hxk 0 Credit Card Safe 3 of 3 4/30/2020, 2:41 PM CBUCK Engineering Spealalty Structural EnVneprinq CBUCK, Inc. Certificate of Authorization 118064 Evaluation Report "Solar Attic Fans" Self -Flashing Series with Shroud/Dome Mounted Solar Panel 20 Watts, 30 Watts & 40 Watts Solar Panels Manufacturer Attic Breeze, LLC. 1370 FM 116 Gatesville, Texas 76528 (877)288-4234 for Florida Product Approval # FL 13339.1 R6 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: Category: Sub - Category: Product Name: Product Description: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Report No. 18-101-SPAF-Dir-S4W-ER Date: 1/4/ 18 Contents: Evaluation Report Pages 1— 6 2-B Roofing Roofing Accessories that are an Integral Part of the Roofing System Solar Attic Fans Self -Flashing Series F cSIr IAtof digital copy signed b, m with Shroud/Doe Mounted Solar pes L. Buckner, P.E. Electronically signed and sealed documet comply with the provisions of FAC Rule 6 q'j�y1i11111rr,"J L. BUCt * No 31242 .�C).,A' STATE OF LU �� 'irC�'�jS" •. F'COR1D�'. �j���� rrr�iittt►�' CBUCK, Inc. -Palm Beach County, Florida 2018.01.04 15:00:37 -05'01 Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net CSUCK Engineering Specialty Structural Engineering Manufacturer: Attic Breeze, LLC. Product Name: Solar Attic Fans Product Category: Roofing FL #: FL 13339.1 R6 Date: 1/4/18 Report No.: 18-101-SPAF-Dir-S4W-ER Page 2 of 6 CBUCK, Inc. Certificate of Authorization #8064 Product Sub -Category Roofing Accessories that are an Integral part of the Roofing System Compliance Method: State Product Approval Rule 61G20-3.005 (2) (b) Product Description: The Solar Attic Fan is a roof mounted system powered by a solar panel. The unit consists of a 14 inch diameter fan, enclosed in a self -flashing fan house base vent, with corrosion resistant, zincalume alloy steel housing, including a thermal switch, and a rodent guard. The solar panel is attached directly to the fan house unit shroud/dome. Product Assembly as Self -flashing solar attic fan with shroud/dome mounted solar panel Evaluated: - Fan house base unit component mechanically attached to deck with wood screws. Model Numbers: No./Designation AB -201A AB -202A AB -251A AB -252A AB -2022A AB -3022A AB -4022A Fan Unit Base Support: Type: Wood Deck (Design of support system is outside the scope of this evaluation) Description: • 15/32" or greater Plywood, or • Wood plank deck (based on minimum density/specific gravity of 0.42) Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering. Performance: Allowable Wind Resistance: * Positive Design Pressure: + 115 PSF * Negative Design Pressure: -115 PSF * Allowable design pressures for allowable stress design (ASD). FL M FL 13339.1 R6 Date: 1/4/18 CBUCK Engineering Report No.: 18-101-SPAF-Dir-S4W-ER Page 3 of 6 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The following test protocol was performed to demonstrate compliance with the intent of the code as this product does not specifically addressed the performance standard in the code. • ASTM E330-02 — Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 6th Edition (2017), Section 1708.2. Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural wind load requirements of the Florida Building Code, as related to Florida Product Approval Rule 61G20-3.001. Limits of Use: The Solar Attic Fan including solar panel and electrical wiring shall be installed in compliance with Attic Breeze's installation instructions and in accordance with applicable Building Codes • Scope of "Limitations and Conditions of Use" for this evaluation: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61G20 -3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Refer to applicable building code section for ventilation requirements. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certification, Inc. (FBC Organization #: QUA 1824) CBUCK Engin erinq Specllalhy Structural Engineering Component(s) Solar Attic Fan Material Standards: - Nominal Dimensions Fan House Base: Fan House Shroud/ Dome: Solar Panel: Overall Height: FL #: FL 13339.1 R6 Date: 1/4/18 Report No.: 18-101-SPAF-Dir-S4W-ER Page 4 of 6 CBUCK, Inc. Certificate of Authorization #8064 28" x 28„ 21-1/2" x 21-1/2" 19-1/4" x 16-1/4" 12" - Fan House Base & Shroud/Dome Material: Material: Steel Thickness: 22 ga. Yield Strength: 33 ksi Minimum Corrosion Resistance: Galvalume or Zincalume per ASTM A792 AZ 50 or in compliance with the FBC, Section 1507.4.3. Fastener Type: Size: Standard: Corrosion Resistance: Pancake Head Wood Screw #10 x 1 in. Minimum Per ANSI/ASME 818.6.1 Per FBC Section 1506.6 Installation: Installation Method: (Refer to Pages 5 and 6 of this evaluation report.) "The Solar Attic fans" shall be installed in compliance with the installation method listed in this report. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Evaluated Referenced Data: 1. ASTM E330-02 — Uniform Static Air Pressure Difference Test By Certified Testing Laboratories, Inc. (FBC Organization IN TST 1577) Project #: CTLA 2002W, Dated: 11 / 20 / 09 2. Quality Assurance By Keystone Certification, Inc. (FBC Organization ID# QUA 1824) Attic Breeze, LLC. Licensee #740 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Engineering Analysis By CBUCK Engineering Report #C09-194, Dated: 12 / 1 / 09 Report #C16-164, Dated: 10 / 20 / 16 FL #: FL 13339.1 R6 Date: 1/4/18 CSUCK EngineL=ring Report No.: 18-101-SPAF-Dir-54W-ER Page 5 of 6 SpPclalhy Structural EnglnPL=rinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Attic Breeze, LLC. Solar Attic Fan Attachment Assembly Solar Panel Fan House Shroud 4-114' 1' Fan House Base 4-1/4' Assembly Front Section View — — Solar Panel Fan House Shroud Fan House 20" Diameter #10 x 1" Pancake -Head RW ood Deck Wood Screw Typical Opening 2-1/4" Assembly Side Section View 15132" Nin. 20 " Diarreter 4 #10 x 1" Fl h- lad Mod Screw Flyer DeckPlyuvuod Typical Opening Deck 15/32" Nin. Assembly Front Section View — — Solar Panel Fan House Shroud Fan House 20" Diameter #10 x 1" Pancake -Head RW ood Deck Wood Screw Typical Opening 2-1/4" Assembly Side Section View 15132" Nin. CBUCK Engineering FL #: FL 13339.1 R6 Date: 1/4/18 Report No.: 18-101-SPAF-Dir-S4W-ER Page 6 of 6 Speciafty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method Attic Breeze, LLC. Solar Attic Fan Attachment Assembly Assembly Top Plan View