Loading...
HomeMy WebLinkAboutMorris Gulf Coast Metal _20200507161053Florida Building Code Online https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wG.., OF Professional Regulation rid BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I search gy 4 r �� Product Approval b -ff�... USER: Public User 01 Product Approval Menu > Product or Apolkation Search > Application Lis > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence FL11651-R3 Revision 2017 Approved Gulf Coast Supply & Manufacturing, LLC, 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352)498-0778 info@gulfcoastsupply.com Eng David info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352) 498-0778 david,eng@gulfcoastsupply.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Daniel S. Kuhn PE -75519 Keystone Certifications, Inc. 04/12/2024 Locke Bowden RE, Validation Checklist - Hardcopy Received FL11651_R3_CCI_CertofIndeRer!dence_2017-10-09.pdf Referenced Standard and Year (of Standard) Standard FM 4471 TAS 100 TAS 110 TAS 125 UL 1897 Year 1992 1995 2000 2003 2012 1 of 5 4/30/2020, 2:35 PM Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page 0 https://www.floridabuilding.org/pr/pr—app_dti.aspx?param=wG... UL 580 Method 1 Option D 10/10/2017 10/12/2017 10/17/2017 12/12/2017 2006 0 0 Page 1/ 2 0 0 FL # Model, Number or Description Name 0.032" Aluminum 5V 11651.1 Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Crimp Installation Instructions Limits of Use Approved for use in HVHZ: No FL11651_R3_II_FL11651_1_R3_Metal_Roof_Panel_Detail-signed.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-108.5PSF Evaluation Reports Other: -108.5 psf @ 12" o.c. Install FL11651_R3_AE_FL11651_S_R3_0325vCrimp_15-32Plywood_NonHVHZ- signed,pdf per manufacturers details, Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.2 0.032" Aluminum Gulf Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Lok Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_2_R3_Metal_Roof_Panel_Detail-signad,pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, RE, 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-116.OPSF Evaluation Reports Other: -52.5 psf @ 5 3/16" o.c. FL11651_R3_AE_FL11651_2_R3_032GulfLok_16_15-32Plywood_NonHVHZ- fastener spacing. -116,0 psf @ 5 3/16" signed,pdf o.c. fastener spacing, Install per Created by Independent Third Party: Yes manufacturers details. Not for use in HVHZ Zones. 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood 11651.3 1" 24ga. Gulf Snap Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_3_R3_Metal_Roof_Panel_Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/--131.OPS Evaluation Reports Other: -67.3 psf @ 24" o.c. clip FL11651_R3_AE_FL11.651_3_R3_1_24GulfSnap_17_15-32Plywood_HVHZ- signed.pdf spacing. -131 psf @ 6" o.c. clip spacing. Install per manufacturers details. For Created by Independent Third Party: Yes use in HVHZ Zones. i 11651.4 1" 24ga. VersaLoc 1" VersaLoc 24ga 16.5' Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_4_R3_Metal_Roof_Panel_Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-138.5PSF Evaluation Reports Other: -71 psf @ 24" o.c. clip spacing. F1.11651_ R3 AE FL11651 4 R3 24Versal-oc SR 16.5 15-32 Plywood HVHZ- -138.5 psf @ 6" o.c. clip spacing. Install signed,pdf per manufacturers details. For use in Created by Independent Third Party: Yes HVHZ Zones. 11651.5 1" VersaLoc .032" 1" VersaLoc min .032" Aluminum over 15/32" Plywood Aluminum 2 of 5 4/30/2020, 2:35 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG... Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_5_R3_Metal_ Roof Panel_Detail-signed.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-101.OPSF Evaluation Reports Other: -63.3 psf @ 24" o.c. clip FL11651_R3_AE_FL11651_5_R3_lin_032VersaLoc SR_16_15-32Plywood_HVHZ- spacing. -101.0 psf @ 6" ox. clip signed.pdf spacing. Install per manufacturers Created by Independent Third Party: Yes details. For use in HVHZ Zones. 11651.6 1 1.5" 24ga. Gulf Snap 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_6_R3_Metal_Roof_Panel_Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-116.OPSF Evaluation Reports Other: -86.0 psf @ 24" o.c. clip FL11651_R3_AE_FL11651_6_R3_1.5_24GulfSnap_16_15-32Plywood_HVHZ- signed.pdf spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip Created by Independent Third Party: Yes spacing. Install per manufacturers decals. For use in HVHZ Zones. 11651.7 1.5" 24ga. Versa Loc 1.5" Versa Loc min 24ga. 16" wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes_R�'_fiQta_RgQf?�S1_�I_I?eS�il- lgnedpff Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-123.5PSF Evaluation Reports Other: -59.75 psf @ 24" o.c. clip FL11651_R3_AE_FL11651_7_R3_1.5_24VersaLoc_16_15-32Plywood_HVHZ- spacing. -123.5 psf @ 12" o.c. clip signed,pdf spacing. Install per manufacturers Created by Independent Third Party: Yes details. For use in HVHZ Zones. 11651.8 2" 24ga. MegaLoc Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood Installation Instructions Limits of Use Approved for use in HVHZ: No FL11651_R3_II_FL11651_8_R3_Metal_Roof_Panel_Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-108.5PSF Evaluation Reports Other: -71.0 psf @ 24" o.c. clip FL11651_R3_AE_FL11651_8_R3_24VersaLoc_18_15-32Plywood_NonHVHZ- signed.pdf spacing. -108.5 psf @ 12" ox, clip spacing. Install per manufacturers Created by Independent Third Party: Yes details. Not for use in HVHZ Zones. 11651.9 24 Ga. Gulf Lok Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_9_R3_Metal_Roof_Panel_Detail-signed.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-96.7PSF Evaluation Reports Other: -81.75 psf @ 10-1/4" o.c, FL11651_R3_AE_FL11651_9_R3_24GulfLok_16_15-32Plywood_NonHVHZ- fastener spacing. -96.76 psf @ 5-1/8" signed.pdf o.c. fastener spacing. -121.75 psf @ Created by Independent Third Party: Yes 5-1/8" fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.10 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_10_R3_ Metal _ Roof_ Panel_Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-93.5PSF Evaluation Reports Other: -93.5 psf @ 18" o.c. Install per FL11651_R3_AE_FL11651_10_R3_24GulfSeam_16_1x4_15-32Plywood_NonHVHZ- signed.pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.11 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_ll_R3_Metal_Roof_Panel_Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-108.5PSF Evaluation Reports Other: -69.25 psf @ 24" o.c. clip FL11651_R3_AE_FL11651_11_R3_24Gulf5eam_18_15-32Plywood_NonHVHZ- 3 of 5 4/30/2020, 2:35 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr app_dtl.aspx?pararn=wG... spacing. -108.5 psf @ 12" ox, clip signed.pdf spacing. Install per manufacturers Created by Independent Third Party: Yes details. Not for use in HVHZ Zones. 11651.12 26 Ga. SV Crimp Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_12_R3_ Metal _ Roof_ Panel _Detail-signgd.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-156.5PSF Evaluation Reports Other: -108.5 psf @ 12" o.c. fastener FL11651_R3_AE_FL11651_12_R3_265vCrimp_15-32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes spacing, -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.13 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_13_R3_Metal_ Roof_ Panel_ Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-131,PSF Evaluation Reports Other: -94.25 psf @ 16" ox, fastener FL11651_R3_AE_FL11651_13_R3_265vCrimp_15-32PIywood_NonHVHZ- signed,pdf pattern. -131.0 psf @ 16" o.c. fastener pattern. Install per manufacturers Created by Independent Third Party: Yes details, Not for use in HVHZ Zones. 11651.14 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_14_R3_Meta l_Roof_Panel_Detai1-signod,pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-156.5PSF Evaluation Reports Other: -108.5 psf @ 12" o.c. fastener FL11651_R3_AE_FL11651_14_R3_265vCrimp_1x4_15-32Plywood_NonHVHZ- slgned,pdf spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers Created by Independent Third Party: Yes details. For use in HVHZ Zones. 11651,15 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Installation Instructions Limits of Use Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_15_R3_ Metal _ Roof_ Panel_Detail-signed.pdf Verified By: Dan Kuhn, P.E. 75519 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-161.OPSF Evaluation Reports Other: -63.5 psf @ 5 3/16" o.c. FL11651_R3_AE_FL11651_15_R3_26GulfLok_16_15-32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes fastener spacing, -121.75 psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.16 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_16_R3_Metal_Roof_Panel_Detail-signed.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-63.5PSF Evaluation Reports Other: -63,5 psf @ 5 3/16" o.c. FL11651_R3_AE_FL11651_16_R3_26GulfLok_16_15-32Plywood_NonHVHZ- fastener spacing. -121.75 psf @ 5 3/16" signed.pdf fastener spacing. -161 psf @ 5 3/16" Created by Independent Third Party: Yes fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones, 11651,17 26 Ga. GulfPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R II FL11651 17 R3 Metal ,Roof Panej_D Y il=Si,gM0,pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-154.7PSF Evaluation Reports Other: -59.25 psf @ 24" o.c. fastener FL11651_R3_AE_FL11651_17_R3_26GulfPBR_15-32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes pattern. -154.75 psf @ 12" o.c. fastener pattern. Install per manufacturer details, Not for use in HVHZ 11651.18 26 Ga. GulfPBR Min 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood 4 of 5 4/30/2020, 2:35 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wG... Limits of Use I Installation Instructions Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_18_R3_Metal_ Roof_ Panel_Detail-signed.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-151,7PSF Evaluation Reports Other: -100.5 psf @ 24" o.c. fastener FL11651_R3_AE_FL11651_18_R3_26GulfPBR_1x4_15-32Plywood_HVHZ- spacing. -151.75 psf @ 12" fastener signed.pdf spacing. Install per manufacturer's Created by Independent Third Party: Yes details. For use in HVHZ Zones 111651.19 126 Ga. GUIfPBR I Min 26 Ga. GulfPBR over 15/32" Plywood I Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651_R3_II_FL11651_19_R3_Metal _Roof _Panel_Detail-signed.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-154.7PSF Evaluation Reports Other: -60.5 psf @ 24" o.c. fastener FL11651_R3_AE_FL11651_19_R3_26GulfPBR_15-32Plywood_HVHZ-signed.pdf spacing. -154.75 psf @ 12" o.c. fastener Created by Independent Third Party: Yes spacing. Install per manufacturer's details. For use in HVHZ Zones. 11651.20 1 26 Ga. GuIfPBR Min 26 Ga. GUIfPBR over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651_R3_II_FL11651_20_R3_Metal_ROOf_Panel _Detaii-signed.pdf Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-151.7PSF Evaluation Reports Other: -94.25 psf @ 24" o.c. fastener FL11651_R3_AE_FL11651_20_R3_26GulfPBR_1x4_15-32Plywcold _NonHVHZ- spacing. -151.75 psf @ 12" fastener signed.pdf spacing. Install per manufacturer's Created by Independent Third Party: Yes details. Not for use in HVHZ Zones Go to Page 0 Bade next 0 0 Page 1/ 20 0 Contact Us:: =L13181r5tone Road,.7ANaha5saa FL32329 Pknv 85AJ&Z_UZA The State of Florida is an AA/EEO employer. _C_Qpy_W9 t.2.QQ7-2Qx3 tat vi_EiQrxin.:: Privacy Statement :: accessbany Statement :; Refund Statement Under Florida law, email addresses are public records. IF you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487..1395, `Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ice. Product Approval Accepts: 0 fnImo; a�Llret N Credit Card Safe 5 of 5 4/30/2020, 2:35 PM Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC 24 Ga. GulfLokTM 16" Wide Roof Panel over 15132" Plywood Florida Product Approval #11651.9 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20 -3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL# 11651.9 R3 • OCTOBER LLC.,......1"" IF ""IF V% C; E IV�� r � yk No, 7519 _ -0 TATE o %NAIL E,NC; t FLORIDA PRODUCT APPROVAL 11 G uliCoast SUPPLY & MANUFACTURING Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfLokTM, 7/8" Nailstrip Roof Panel, Minimum 24 Ga. Steel, Maximum 16" Coverage, Roof panel restrained with fasteners into minimum 15/3z" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 24 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.0235" Minimum Width: 16" Coverage Maximum Female Rib: 7/e" Tall Male Rib: 3/4" Tall Rib with Slotted Strip Panel Seam: Snap Lock Panel Clip: 24 Ga. Zinc Aluminum Coated Steel, 24" Long. Used at Corner Zones only, where required design pressures exceed -121.75 psf. Panel Fastener: Through Panel Slot: (1) #10-12x1 " Pancake Type A 1/4" Minimum Penetration through Plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design Uplift Pressures: Table "A" Maximum Design Pressures Roof Areas Assembly A Assembly B Assembly C Assembly D Maximum Design Pressures 81.75 psi 96.75 psf -121.75 psf -161 psf Fastener Spacing 10 1%" 0.C. S�/s" [3.0 5'/8" 0.0 5'/8" [7.0 Sealant No No Yes No Panel Clip j No No. No Yes *Design Pressure includes a Safety Factor = 2.0. FL# 11651.9 R3 • OCTOBER 5, 2017 14 1 A DUCT APPROVAL FLORID G 61 Cogs SUPPLY & MANUFACTURING Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 1 17-0089T-05 Dated 06/2005 2. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117 -0301T -10A -C, Dated 07/26/2013 3. TAS 125 Architectural Testing, Inc. (FBC Organization # TST-1527) Report No. B9000.01-450-18, Dated 12/12/2012 4. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. FL# 11651.9 R3 • OCTOBER 5, 2017 —.00 �.7!wra\ - Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including FL# 11651.9 R3 • OCTOBER 5, 2017 Section 1507.4.2 and in accordance with Manufacturers recommendations. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.9 R3 • OCTOBER 5, 2017 ENGINEER LOAD TABLE: 24 Ga. GulfLokTM 16" Wide Roof Panel over 15/32" Plywood Buildings having a Roof Mean Height < 20'-0"; Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category II, Enclosed Building, based on Florida Building Code 2017. SPACING. SEE UPLIFT TABLE 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE (1) #10-12 X 1' TYPE A PANCAKE SPACING: SEE UPLIFT TABLE ASSEMBLY D W/CLIP GuI1Lok'" CLIP 24 GA, T_ SPEED (MIN. Penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 (1) #10-120" CDX PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ZONE 2 (1) #10-120" CDX PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ZONE 3 (1) #10-12x1" CDX PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY B ASSEMBLY B ASSEMBLY C 1.) PANEL DESCRIPTION: GULFLOKTM, MIN. 24 GA, 7/8" RIB, 16" MAXIMUM COVERAGE, SNAP SEAM. 2.) PANEL FASTENER: (1) #10-12X1 " PANCAKE TYPE A, IN" MIN. PENETRATION THROUGH PLYWOOD. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 81,75 PSF AT 10'/4" O.C. ASSEMBLY A, 96.75 PSF AT 5'/a" O.C. ASSEMBLY B, -121.75 PSF AT 51/8" O.C, WITH SEALANT ASSEMBLY C, -161 PSF AT 5'/8" O.C. WITH CLIP ASSEMBLY D. PRESSURE BASED ON UL 580/UL 1897 TESTING BY FORCE ENGINEERING & TESTING. 4.) PLYWOOD DECKING: MIN.15/32" THICK, APA RATED PLYWOOD, GRADE C -D. MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE 2 HIP RODF a ZONE 3 � 4 RIDGE tZONE1 — EAVE ZONE 2 GABLE ROOF ial 'a i I I RIDGE I ti I t I ZONE 1 ZONE 3 EAVE FL# 11651,9 R3 • OCTOBER 5, 2017 Note: Dimension (a) is defined as 10% of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be a less than either 4% of the minimum width of the building or 3 feet. ASSEMBLY A/B y� 16" COVERAGE a a (1) # 10.12 X 1"TYPE A PANCAKE SPACING: SEE UPLIFT TABLE (1) #10.12 X 1"TYPE A PANCAKE SPACING. SEE UPLIFT TABLE ASSEMBLY C 1/4"-5/16" DIAMETER BEAD OF TITEBOND SEALANT (1) #10-12 X 1' TYPE A PANCAKE SPACING: SEE UPLIFT TABLE ASSEMBLY D W/CLIP GuI1Lok'" CLIP 24 GA, T_ (1) # 10.12 X 1"TYPE A PANCAKE SPACING: SEE UPLIFT TABLE