Loading...
HomeMy WebLinkAboutMorris Roofnado FBC_20200507161159Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wG... Professional ' 1 BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge I Stats & Facts j Publications I Contact Us BCIS Site Map Links Search b' Product Approval r4 USER: Public User Product Approval Menu > Product or Apolication Search > Application Llst > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL21895-R2 Revision 2017 Approved Sentry Building Innovations 1209 Orange Street Wilmington New Castle, DE 19801 (604) 612-5289 mseth@sentrybuilding,com Marsha Hollandsworth Mhollandsworth@sentrybuilding.com Marsha Hollandsworth 1209 Orange Street Wilmington New Castle, DE 19801 (843) 735-1773 Mhollandsworth@sentrybuilding.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE -59166 QAI Laboratories 02/09/2022 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL21895_R2_COI_2018_01_COI_NIEMINEN,pdf Standard ASTM D1970 ASTM D226 (physicals) ASTM D4533 (tear) ASTM D4798 FRSA/TRI APRIL 2012 UL1897 Year 2015 2009 2015 2011 2012 2012 1 of 2 5/4/2020, 4:20 PM Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved of Products FL # I Model, Number or Name https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wG... Method 1 Option D 12/11/2018 12/17/2018 12/21/2018 02/19/2019 21895.1 Roofnado Synthetic Roofing Underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/ -97.5 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure herein pertains to one underlayment assembly, when used beneath foam -on tile roof systems. Refer to ER Section 5.6.3. Description Synthetic roofing underlayments Installation Instructions FL21895 R2_11 2018-12_FINAL SBI RDOFNADO FL21895_ R2. pd f Verified By: Robert Nieminen PE -59166 Created by Independent Third Party: Yes Evaluation Reports EL21895R2_AAE= 019,_1_2_FINAL_SBI_ROOFN_ADQ_FL21�95- R2. p -d f Created by Independent Third Party: Yes pods Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Pho.ne;B50,487-18ZA The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: PrIvacy�StaIe grit :: Ac*ussb*v Statement :: Retunl 5jaMm ht Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publlc-records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public, To determine if you are a licensee under Chapter 455, F.S., please click here-. Product rtAApproov�val Accepts: lel eCheck M Credit Card Safe 2 of 2 5/4/2020, 4:20 PM NEMO I etc. Certificate of Authorization 1132455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Sentry Building Innovations Evaluation Report 13925.02.17-1-R2 1209 Orange Street, Wilmington, FL21895-R2 New Castle, DE 19801 Date of Issuance: 02/16/2017 (843) 735-1773 Revision 2: 12/11/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6` Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: RoofnadOTM Synthetic Roofing Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: tit Yf 1 le Robert J.M. Nieminen, P.E. ti r;� i •;��;•:,hb;.^.�;�. The facsimile seal appearing was authorized by Robert •., Nieminen, P.E. on 12/11/2018. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 ''�+ ,;,° . ''- electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOletc, does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOI etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. MEMO I etc. ROOFING COMPONENT EVALUATION: 4.1 4.2 Name Description Specification Roofnado'M Synthetic polymer -based scrim -reinforced underlayment, FBC 1507.1.1 & AnchorDeckTM consisting of woven polyolefin base with a layer of nonwoven R905.1.1 polyolefin sheet and a polymer coating on the back side, (Exception) available in rolls 48 -inch x 250 -ft with a nominal unit weight of 2.25 lbs/square. RoofnadoTM Synthetic polymer -based scrim -reinforced underlayment, StormTreadTM consisting of woven polyolefin base with a layer of nonwoven polyolefin sheet and a polymer coating on the back side, available in rolls 48 -inch x 250 -ft with a nominal unit weight of 3.80 lbs/square. Manufacturing Location(s) Dadra, India FBC 1507.1.1 & Dadra, India R905.1.1 (Exception) NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2 Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2 Roofnado'" Synthetic Roofing Underlayments Revision 2: 12/11/2018 Page 2 of 5 SCOPE:1. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RoofnadOTM Synthetic Roofing Underlayments, as produced by Sentry Building Innovations, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Properties Standard Year 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D4533 2015 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D226 ACT-SC14110.05.17-2 05/24/2017 ERD(TST6049) ASTM D226 ACT-SC14110.05.17-3 05/24/2017 ERD(TST6049) ASTM D4533 ACT-SC16550.17 10/19/2017 ICC -ES (EVL2396) IBC/IRC compliance ESR -4055 03/01/2017 NEMO (TST6049) UL 1897 4L -ACT -18-002.07.18-2 07/05/2018 NEMO (TST6049) AC152 4S -ACT -18-001.10.18-1B 10/08/2018 NEMO (TST6049) FRSA/TRI April 2012 4S -ACT -18-001.11.18-2B 11/12/2018 QAI (TST9808) ASTM E108 RJ3502-1 09/29/2014 QAI (TST9808) ASTM E108 RJ3502-2 09/29/2014 QAI (TST9808) Physical Properties, AC188 RJ3502P-1 11/05/2014 QAI (TST9808) Physical Properties, AC188 RJ3502P-2 11/05/2014 CAI (TST9808) ASTM D1970 RJ5365P-3 04/26/2017 QAI (TST9808) ASTM D1970 (adhesion) RJ5365P-4 06/29/2017 QAI (QUA7628) Traceability/Inspections Service Confirmation, India 02/09/2017 QAI (QUA7628) Traceability/Inspections Service Confirmation, UAE 02/09/2017 4.1 4.2 Name Description Specification Roofnado'M Synthetic polymer -based scrim -reinforced underlayment, FBC 1507.1.1 & AnchorDeckTM consisting of woven polyolefin base with a layer of nonwoven R905.1.1 polyolefin sheet and a polymer coating on the back side, (Exception) available in rolls 48 -inch x 250 -ft with a nominal unit weight of 2.25 lbs/square. RoofnadoTM Synthetic polymer -based scrim -reinforced underlayment, StormTreadTM consisting of woven polyolefin base with a layer of nonwoven polyolefin sheet and a polymer coating on the back side, available in rolls 48 -inch x 250 -ft with a nominal unit weight of 3.80 lbs/square. Manufacturing Location(s) Dadra, India FBC 1507.1.1 & Dadra, India R905.1.1 (Exception) NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2 Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2 Roofnado'" Synthetic Roofing Underlayments Revision 2: 12/11/2018 Page 2 of 5 FName Description 4.3 RoofnadOT" Synthetic polymer -based scrim -reinforced underlayment, ShingleLockT" consisting of woven polyolefin base with a layer of nonwoven polyolefin sheet and a polymer coating on the back side, available in rolls 48 -inch x 250 -ft with a nominal unit weight of 3.80 lbs/square. 4.4 RoofnadoTM Self -adhering underlayment consisting of a synthetic top- LapLockTP1 PSU facer, polymer modified bitumen and a release liner, available in rolls 36 -inch x 67 -ft with a nominal 60 -mil thickness. *NEMO I etc. Specification Manufacturing Location(s) FBC 1507.1.1 & Dadra, India R905.1.1 (Exception) ASTM D1970 & United Arab FRSA/TRI April Emirates 2012 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification does not form part of this evaluation; refer to QAI Laboratories (www.gai.org) current Building Products Listing Directory for fire listings of this product. Note: ASTM E108 reports furnished by the applicant indicate RoofnadOTM Synthetic Roofing Underlayments may be used as a component of a classified roof assembly with a roof covering of Class A, B or C glass fiber mat asphalt - shingles complying with the 6th Edition (2017) Florida Building Code or in Class A roof assemblies with the roof coverings specified in the exceptions to FBC Section 1505.2, when installed report over minimum 3/8 -inch thick AC Exterior Grade plywood deck. 5.4 Roofnado'm Synthetic Roofing Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers: 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWA13LE TILE ,.HESIVE / UNDERLAYMENT COMBINATIONS' UNDERLAYMENT ADHESIVE FLORIDA PRODUCT APPROVAL LapLockT°" PSU ICP Adhesives Polyset® AH -160 FL6332 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2 Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2 RoofnadoT" Synthetic Roofing Underlayments Revision 2:12/11/2018 Page 3 of 5 TA13LE 1: ROOF COVEROPTIONS ASPHALT & WOOD SYNTHETIC FOAM -ON SHAKES & UNDERLAYMENT SHINGLES NAIL -ON TILE No TILE No METAL Yes SHINGLES Yes SLATE AnchorDeckTM Yes Yes Yes (residential only) Yes (primed cedar) Yes Yes StormTreadTM No No (primed cedar) ShingleLockT"" Yes No No Yes Yes Yes _ (primed cedar) Yes Yes LapLockT"" PSU Yes Yes Yes Yes (See 5.5.1) 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWA13LE TILE ,.HESIVE / UNDERLAYMENT COMBINATIONS' UNDERLAYMENT ADHESIVE FLORIDA PRODUCT APPROVAL LapLockT°" PSU ICP Adhesives Polyset® AH -160 FL6332 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2 Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2 RoofnadoT" Synthetic Roofing Underlayments Revision 2:12/11/2018 Page 3 of 5 ONEMOletc. 5.6 Allowable Substrates; Roofnado'' LapLock'" PSU: 5.6.1 Direct -Bond to Deck: ➢ New or existing untreated plywood; primed or primed with ASTM D41 primer. ➢ New or existing untreated OSB; primed or primed with ASTM D41 primer. 5.6.2 Bond to Mechanically Attached Base Sheet_: ➢ ASTM D226, II felt. 5.6.3 Wind Resistance for Underla ment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design. Pressure =-97.5Jpsf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: RoofnadoT"I LapLock'" PSU, self -adhered and back -nailed max. 12" o.c. 5.7 Exposure Limitations: Roofnado'"° AnchorDeck'", StormTreadT"I or ShingleLock'" shall not be left exposed for longer than 30 -days. Roofnado'"' LapLock'"' PSU shall not be left exposed for longer than 90 -days. 5.8 Tile Slippage Limitations f per FRSA/TRI April 2012(94-_121L 1211: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. INSTALLATION:6. 6.1 Roofnado'"' Synthetic Roofing Underlayments shall be installed in accordance with Sentry Building Innovations published installation instructions subject to the Limitations set forth in Section 5 herein and the guidelines noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Roofnado'"' AnchorDeck'', StormTread'"' or ShingleLock'"": 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width. NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2 Certificate afAuthorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2 Roofnado'" Synthetic Roofing Underlayments Revision 2: 12/11/2018 Page 4 of 5 NNEMO I etc. 6.3.2 Fasteners: ✓ If primary roof cover is installed within 24 -hours, fasteners may be corrosion resistant 3/8 -inch head x 1 -inch long roofing nails ✓ If primary roof cover is installed after 24 -hours, fasteners shall be plastic cap nails or metal cap nails with minimum 1 -inch diameter head. x Do not use staples. Ensure fasteners are installed at 90 degree angle to the deck with flush contact between the cap and the upper surface of the underlayment. Fasteners shall be of sufficient length to penetrate through the underside of plywood or OSB decks, or minimum 3/ -inch embedment into dimensional lumber / tongue -and -grove wood decks. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, V It, equals or exceeds 150 mph. 6.3.3 When required by the local building code or Authority Having Jurisdiction, install a leak barrier of ASTM D1970 or equal holding Florida Statewide Product Approval or Local Approval at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. 6.3.4 Single Layer, Slopes of 4:12 and more: End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 3 -inches. Ensure all vertical end -laps are staggered at least 3 -feet apart. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1, considering the wider sheet - width. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.5 Double Layer. Sloes between 2:12 and 4:12: Double layer application; begin by fastening a 25.5 -inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.4, but maintaining minimum 25.5 - inch side (horizontal) laps, resulting in a double -layer application and 6 -inch wide end (vertical) laps. Ensure all vertical end -laps are staggered at least 6 -feet apart. 6.3.6 Contact Sentry Building Innovations [(843) 735-1773] for exposure to high wind velocity areas. 6.4 EofnadoTm LapLockTM PSU: 6.4.1 Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, and Sentry Building Innovations published requirements. 6.4.2 Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Sentry Building Innovations published requirements. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Sentry Building Innovations published requirements for tile staging. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. QUALITY8. QAI Laboratories — QUA7628; (604) 527-8378, mianscfowne@qai.org - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2 Certificate ofAuthorizatlon #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2 Roofnado'm Synthetic Roofing Underlayments Revision 2: 12/11/2018 Page 5 of 5