HomeMy WebLinkAboutMorris Roofnado FBC_20200507161159Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wG...
Professional ' 1
BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge I Stats & Facts j Publications I Contact Us BCIS Site Map Links Search
b'
Product Approval
r4 USER: Public User
Product Approval Menu > Product or Apolication Search > Application Llst > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL21895-R2
Revision
2017
Approved
Sentry Building Innovations
1209 Orange Street Wilmington
New Castle, DE 19801
(604) 612-5289
mseth@sentrybuilding,com
Marsha Hollandsworth
Mhollandsworth@sentrybuilding.com
Marsha Hollandsworth
1209 Orange Street Wilmington
New Castle, DE 19801
(843) 735-1773
Mhollandsworth@sentrybuilding.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE -59166
QAI Laboratories
02/09/2022
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL21895_R2_COI_2018_01_COI_NIEMINEN,pdf
Standard
ASTM D1970
ASTM D226 (physicals)
ASTM D4533 (tear)
ASTM D4798
FRSA/TRI APRIL 2012
UL1897
Year
2015
2009
2015
2011
2012
2012
1 of 2 5/4/2020, 4:20 PM
Florida Building Code Online
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of Products
FL # I Model, Number or Name
https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wG...
Method 1 Option D
12/11/2018
12/17/2018
12/21/2018
02/19/2019
21895.1 Roofnado Synthetic Roofing
Underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/ -97.5
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure herein pertains to one underlayment
assembly, when used beneath foam -on tile roof systems.
Refer to ER Section 5.6.3.
Description
Synthetic roofing underlayments
Installation Instructions
FL21895 R2_11 2018-12_FINAL SBI RDOFNADO FL21895_
R2. pd f
Verified By: Robert Nieminen PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
EL21895R2_AAE= 019,_1_2_FINAL_SBI_ROOFN_ADQ_FL21�95-
R2. p -d f
Created by Independent Third Party: Yes
pods Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Pho.ne;B50,487-18ZA
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: PrIvacy�StaIe grit :: Ac*ussb*v Statement :: Retunl 5jaMm ht
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publlc-records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public, To determine if you are a licensee under Chapter 455, F.S.,
please click here-.
Product rtAApproov�val Accepts:
lel eCheck M
Credit Card
Safe
2 of 2 5/4/2020, 4:20 PM
NEMO I etc.
Certificate of Authorization 1132455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Sentry Building Innovations Evaluation Report 13925.02.17-1-R2
1209 Orange Street, Wilmington, FL21895-R2
New Castle, DE 19801 Date of Issuance: 02/16/2017
(843) 735-1773 Revision 2: 12/11/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6` Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: RoofnadOTM Synthetic Roofing Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
tit
Yf 1
le
Robert J.M. Nieminen, P.E.
ti r;� i
•;��;•:,hb;.^.�;�.
The facsimile seal appearing was authorized by Robert
•.,
Nieminen, P.E. on 12/11/2018. This does not serve as an
Florida Registration No. 59166, Florida DCA ANE1983
''�+ ,;,° . ''-
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc, does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOI etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
MEMO I etc.
ROOFING COMPONENT EVALUATION:
4.1
4.2
Name
Description
Specification
Roofnado'M Synthetic polymer -based scrim -reinforced underlayment, FBC 1507.1.1 &
AnchorDeckTM consisting of woven polyolefin base with a layer of nonwoven R905.1.1
polyolefin sheet and a polymer coating on the back side, (Exception)
available in rolls 48 -inch x 250 -ft with a nominal unit weight
of 2.25 lbs/square.
RoofnadoTM Synthetic polymer -based scrim -reinforced underlayment,
StormTreadTM consisting of woven polyolefin base with a layer of nonwoven
polyolefin sheet and a polymer coating on the back side,
available in rolls 48 -inch x 250 -ft with a nominal unit weight
of 3.80 lbs/square.
Manufacturing
Location(s)
Dadra, India
FBC 1507.1.1 & Dadra, India
R905.1.1
(Exception)
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2
Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2
Roofnado'" Synthetic Roofing Underlayments Revision 2: 12/11/2018
Page 2 of 5
SCOPE:1.
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: RoofnadOTM
Synthetic Roofing Underlayments, as produced by
Sentry Building Innovations,
have demonstrated compliance
with the following sections of the 6th Edition (2017) Florida Building Code through
testing in accordance with applicable sections of the following
Standards. Compliance is subject to the Installation
Requirements and Limitations
/ Conditions of Use set forth herein.
2. STANDARDS:
Section
Properties
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, R905.1.1 Exception
Unrolling, Breaking Strength,
Pliability ASTM D226
2009
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D4533
2015
1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12) 2012
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entity
Examination
Reference
Date
ERD(TST6049)
ASTM D226
ACT-SC14110.05.17-2
05/24/2017
ERD(TST6049)
ASTM D226
ACT-SC14110.05.17-3
05/24/2017
ERD(TST6049)
ASTM D4533
ACT-SC16550.17
10/19/2017
ICC -ES (EVL2396)
IBC/IRC compliance
ESR -4055
03/01/2017
NEMO (TST6049)
UL 1897
4L -ACT -18-002.07.18-2
07/05/2018
NEMO (TST6049)
AC152
4S -ACT -18-001.10.18-1B
10/08/2018
NEMO (TST6049)
FRSA/TRI April 2012
4S -ACT -18-001.11.18-2B
11/12/2018
QAI (TST9808)
ASTM E108
RJ3502-1
09/29/2014
QAI (TST9808)
ASTM E108
RJ3502-2
09/29/2014
QAI (TST9808)
Physical Properties, AC188
RJ3502P-1
11/05/2014
QAI (TST9808)
Physical Properties, AC188
RJ3502P-2
11/05/2014
CAI (TST9808)
ASTM D1970
RJ5365P-3
04/26/2017
QAI (TST9808)
ASTM D1970 (adhesion)
RJ5365P-4
06/29/2017
QAI (QUA7628)
Traceability/Inspections
Service Confirmation, India
02/09/2017
QAI (QUA7628)
Traceability/Inspections
Service Confirmation, UAE
02/09/2017
4.1
4.2
Name
Description
Specification
Roofnado'M Synthetic polymer -based scrim -reinforced underlayment, FBC 1507.1.1 &
AnchorDeckTM consisting of woven polyolefin base with a layer of nonwoven R905.1.1
polyolefin sheet and a polymer coating on the back side, (Exception)
available in rolls 48 -inch x 250 -ft with a nominal unit weight
of 2.25 lbs/square.
RoofnadoTM Synthetic polymer -based scrim -reinforced underlayment,
StormTreadTM consisting of woven polyolefin base with a layer of nonwoven
polyolefin sheet and a polymer coating on the back side,
available in rolls 48 -inch x 250 -ft with a nominal unit weight
of 3.80 lbs/square.
Manufacturing
Location(s)
Dadra, India
FBC 1507.1.1 & Dadra, India
R905.1.1
(Exception)
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2
Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2
Roofnado'" Synthetic Roofing Underlayments Revision 2: 12/11/2018
Page 2 of 5
FName Description
4.3 RoofnadOT" Synthetic polymer -based scrim -reinforced underlayment,
ShingleLockT" consisting of woven polyolefin base with a layer of nonwoven
polyolefin sheet and a polymer coating on the back side,
available in rolls 48 -inch x 250 -ft with a nominal unit weight
of 3.80 lbs/square.
4.4 RoofnadoTM Self -adhering underlayment consisting of a synthetic top-
LapLockTP1 PSU facer, polymer modified bitumen and a release liner,
available in rolls 36 -inch x 67 -ft with a nominal 60 -mil
thickness.
*NEMO I etc.
Specification Manufacturing
Location(s)
FBC 1507.1.1 & Dadra, India
R905.1.1
(Exception)
ASTM D1970 & United Arab
FRSA/TRI April Emirates
2012
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire classification does not form part of this evaluation; refer to QAI Laboratories (www.gai.org) current Building
Products Listing Directory for fire listings of this product.
Note: ASTM E108 reports furnished by the applicant indicate RoofnadOTM Synthetic Roofing Underlayments may be
used as a component of a classified roof assembly with a roof covering of Class A, B or C glass fiber mat asphalt -
shingles complying with the 6th Edition (2017) Florida Building Code or in Class A roof assemblies with the roof
coverings specified in the exceptions to FBC Section 1505.2, when installed report over minimum 3/8 -inch thick AC
Exterior Grade plywood deck.
5.4 Roofnado'm Synthetic Roofing Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers:
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWA13LE TILE ,.HESIVE / UNDERLAYMENT COMBINATIONS'
UNDERLAYMENT ADHESIVE FLORIDA PRODUCT APPROVAL
LapLockT°" PSU ICP Adhesives Polyset® AH -160 FL6332
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2
Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2
RoofnadoT" Synthetic Roofing Underlayments Revision 2:12/11/2018
Page 3 of 5
TA13LE 1:
ROOF COVEROPTIONS
ASPHALT &
WOOD
SYNTHETIC
FOAM -ON
SHAKES &
UNDERLAYMENT SHINGLES
NAIL -ON TILE
No
TILE
No
METAL
Yes
SHINGLES
Yes
SLATE
AnchorDeckTM
Yes
Yes
Yes
(residential only)
Yes
(primed cedar)
Yes
Yes
StormTreadTM
No
No
(primed cedar)
ShingleLockT""
Yes
No
No
Yes
Yes
Yes
_
(primed cedar)
Yes
Yes
LapLockT"" PSU
Yes
Yes
Yes
Yes
(See 5.5.1)
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWA13LE TILE ,.HESIVE / UNDERLAYMENT COMBINATIONS'
UNDERLAYMENT ADHESIVE FLORIDA PRODUCT APPROVAL
LapLockT°" PSU ICP Adhesives Polyset® AH -160 FL6332
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2
Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2
RoofnadoT" Synthetic Roofing Underlayments Revision 2:12/11/2018
Page 3 of 5
ONEMOletc.
5.6 Allowable Substrates; Roofnado'' LapLock'" PSU:
5.6.1 Direct -Bond to Deck:
➢ New or existing untreated plywood; primed or primed with ASTM D41 primer.
➢ New or existing untreated OSB; primed or primed with ASTM D41 primer.
5.6.2 Bond to Mechanically Attached Base Sheet_:
➢ ASTM D226, II felt.
5.6.3 Wind Resistance for Underla ment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April
2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design. Pressure =-97.5Jpsf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: RoofnadoT"I LapLock'" PSU, self -adhered and back -nailed max. 12" o.c.
5.7 Exposure Limitations:
Roofnado'"° AnchorDeck'", StormTreadT"I or ShingleLock'" shall not be left exposed for longer than 30 -days.
Roofnado'"' LapLock'"' PSU shall not be left exposed for longer than 90 -days.
5.8 Tile Slippage Limitations f per FRSA/TRI April 2012(94-_121L
1211:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
INSTALLATION:6.
6.1 Roofnado'"' Synthetic Roofing Underlayments shall be installed in accordance with Sentry Building Innovations
published installation instructions subject to the Limitations set forth in Section 5 herein and the guidelines noted
below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Roofnado'"' AnchorDeck'', StormTread'"' or ShingleLock'"":
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width.
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2
Certificate afAuthorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2
Roofnado'" Synthetic Roofing Underlayments Revision 2: 12/11/2018
Page 4 of 5
NNEMO I etc.
6.3.2 Fasteners:
✓ If primary roof cover is installed within 24 -hours, fasteners may be corrosion resistant 3/8 -inch head x 1 -inch
long roofing nails
✓ If primary roof cover is installed after 24 -hours, fasteners shall be plastic cap nails or metal cap nails with
minimum 1 -inch diameter head.
x Do not use staples.
Ensure fasteners are installed at 90 degree angle to the deck with flush contact between the cap and the upper
surface of the underlayment. Fasteners shall be of sufficient length to penetrate through the underside of plywood
or OSB decks, or minimum 3/ -inch embedment into dimensional lumber / tongue -and -grove wood decks.
6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where
the ultimate design wind speed, V It, equals or exceeds 150 mph.
6.3.3 When required by the local building code or Authority Having Jurisdiction, install a leak barrier of ASTM D1970 or
equal holding Florida Statewide Product Approval or Local Approval at vulnerable leak areas, including but not
limited to eaves, valleys, rakes, skylights and dormers.
6.3.4 Single Layer, Slopes of 4:12 and more:
End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 3 -inches. Ensure all
vertical end -laps are staggered at least 3 -feet apart.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1, considering the wider sheet -
width. When batten systems are to be installed atop the underlayment, the underlayment need only be
preliminarily attached pending attachment of the battens.
6.3.5 Double Layer. Sloes between 2:12 and 4:12:
Double layer application; begin by fastening a 25.5 -inch wide strip along the eaves. Place a full -width sheet over
the starter, completely overlapping the starter course. Continue as noted in 6.3.4, but maintaining minimum 25.5 -
inch side (horizontal) laps, resulting in a double -layer application and 6 -inch wide end (vertical) laps. Ensure all
vertical end -laps are staggered at least 6 -feet apart.
6.3.6 Contact Sentry Building Innovations [(843) 735-1773] for exposure to high wind velocity areas.
6.4 EofnadoTm LapLockTM PSU:
6.4.1 Non -Tile Installations:
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed, and Sentry Building Innovations published
requirements.
6.4.2 Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12), and Sentry Building Innovations published requirements.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer
to Table 2 herein, and Sentry Building Innovations published requirements for tile staging.
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
QUALITY8.
QAI Laboratories — QUA7628; (604) 527-8378, mianscfowne@qai.org
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R2
Certificate ofAuthorizatlon #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL21895-R2
Roofnado'm Synthetic Roofing Underlayments Revision 2: 12/11/2018
Page 5 of 5