Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Construction Plans
RaSE1A Flmidn Solm EnvigyI idusirlr.s AssorWigo June 28, 2017 Dear building official, On June 23`d of 2017 Governor Rick Scott signed HB 1021 amending 377.705 of Florida Statute authorizing solar energy systems manufactured or sold in the state to be certified by professional engineers. In effect a Florida Solar Energy Center, (FSEQ certification is no longer required by state statute for materials or systems to be sold or installed in the state of Florida. On page 6, lines 138-144 read; All solar energy systems sold in the state must meet the standards established by the center and shall display accepted results or approved performance tests in a manner prescribed by the center, unless otherwise certified by an engineer licensed pursuant to chapter 471 using the standards contained in the most recent version of the Florida Building Code. Please find HB 1021 attached for your convenience. This modification to 377.705 will go into effect July 1, 2017 If you have any questions, please feel free to contact FlaSEIA at (407) 339-2010 or (800) 426-5899 Regards, The Board of Directors of FIaSEIA Florida Solar Energy Industries Association (FlaSEIA) 2555 Porter Lake Dr., Suite 106 Sarasota, FL 34240 I HiDM HIGH DENSITY MONO PERC MODULE 320 W - 335 W CS1 H-320 1 325 1 330 1 335MS (IEC1000 V) MORE POWER up To Maximize the light absorption area, 19.afi% module efficiency up to 19.86 % Low NMOT: 42 t 3 °C 42-C Low temperature coefficient(Pmax): -0.37 % / °C 8 Better shading tolerance MORE RELIABLE TLower internal current, lower hot spot temperature Cell crack risk limited in small region, ` enhance the module reliability *** Heavysnow load up to 5400 Pa, wind load up to 2400 Pa �r CanadianSolar ' 25 linear power output warranty product warranty on materials \ Yedn and workmanship MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015 / Quality management system 150 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health 8, safety PRODUCT CERTIFICATES* IEC 61215 / IEC 61730: VDE / CE / CEC AU IEC61701 ED2: VDE /IEC62716: VDE UL 1703: CSA Take -way F 1s +q DVE \ \ ®R. Cep A, � CERT • We can provde this pmductwith speclal 90M specincally canned with salt mist and ammonia tests. Please talk to our local technical sales representatives to get your customized saiudons. CANADIAN SOLAR INC. Is committed to providing high quality solar products, solar system solutions and services to customers around the world. No. 1 module supplier for quality and performance/price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 30 GW deployed around the world since 2001. CANADIAN SOLAR INC. Canadian Solar MSS (Australia) Ply Ltd., 44 Stephenson St, Cremorne VIC 3121, Australia support@canadiansolar.com, www.canadiansolar.com/au ENGINEERING DRAWING (MM) Rear View Frame Cross Section A -A 35 31 r I egan J I � uau.uakna< 8 .............',L__--- ....._E..-Mounting Hole �i b.yMlnl Mru A..` IA �I 992.__ ELECTRICAL DATA I SIC* C_S1H_ 32OMS 325MS 330MS 33_SMS Nominal Max. Power(Pmax) 320 W 325 W 330 W 335 W Opt. Operating Voltage (Vmp) 35.6 V 35.8 V 36.0 V 36.2 V Opt. Operating Current (Imp) 9.00A 9.09A 9.18A 9.27A Open Circuit Voltage (Voc) 43.3 V 43.4 V 43.5 V 43.6 V Short Circuit Current (Isc) 9.51 A 9.58 A 9.65 A 9.73 A Module Efficiency 18.98% 19.27% 19.57%19.86% Operating Temperature Max. System Voltage -40*C-+85*C _ 1500V (IEC) or 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating Application Classification 20 A ClassA Power -Tolerance 0-+5W * Under standard Test Conditions (5TQ of Irradiance of 1000 WAn'. spectrum AM 1.Sandcelltempermureof2 C. Measummentuncsrtaintf.f %(Pmax). ELECTRICAL DATA ( NM OT* CS1H 320MS 325MS 330MS 33SMS Nominal Max. Power (Pmax) 239 W 242 W 246 W 250 W Opt. Operating Voltage (Vmp) 32.5 V 32.7 V 32.8 V 33.0 V Opt. Operating Current (Imp) 7.35 A 7.42 A 7.50 A 7.57 A Open Circuit Voltage (Voc) 40.7 V 40.8 V 40.9 V 41.0 V Short Circuit Current (Isc) 7.67 A 7.73 A 7.78 A 7.84 A *Under Nominal Module Operating Temperature (NMOT), Irradiance of aW W/m; spectrum AM I.S. ambient temperature 206C, wind speed 1 m/s. The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on -going Innovation and product enhancement Canadian Solar lnc reserves the right to make necessary adjustment t0 the Information described herein at any time without further notice. 111;11 1; 5«I1)14 L'lI erc+H;ITI :1 10 15 20 M 30 35 40 45 50 5 10 15 20 25 30 35 0 45 50 ■ mn0.m' 5•C ■ ■ sm.m' 25•C ■ ■ aak= 4s•c ■ ■ 4o0Wfm' 6s•C ■ ® 2WWfm' MECHANICAL DATA Specification Data Cell Type Mono -crystalline Dimensions 1700 x 992 x35 mm (66.9 x 39.1 x 1.38 in) Weight Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy J-Box IP67,3 bypass diodes Cable Cable Length (Including Connector) 4.0 mm2 (IEC), 12 AWG (UL) 1350 mm (53.1 in) Connector T4 series (MC4 series is available) Per Pallet .___ _..._._ Per Container (40'HQ) 30 pieces-, 780 pieces TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient(Pmax) -0.37%/°C Temperature Coefficient(Voc) -0.29%/IC Temperature Coefficient(Isc) 0.05%/*C Nominal Module Operating Temperature 42±3 *C PARTNER SECTION CANADIAN SOLAR INC. Canadian Solar MSS (Australia) Ply Ltd., 44 Stephenson St, Cremorne VIC 3121, Australia support@canadiansolancom, www.canadiansolar.com/au December 2018. Ali rights reserved. PV Module Product Datasheet V5.571AU * Manufactured and assembled in China or Thailand. Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters The high-powered smart grid -ready Enphase IQ 7 Microm and Enphase IQ 7+ Micro'" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten"' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double -insulated enclosure • UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) The IQ 7+ Micro is required to support 72-cell modules. To learn more about Enphase offerings, visit enphase.com EN PHASE. Enphase IQ 7 and IQ 7+ Microinverters INPIIT nATA /nCl I07-en-9-IIS / In7-fin-RAIS 107PI IIS-79-9-IIS / IMPI II1Z-79-R-IIS -. Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage Peak power tracking voltage 27V-37V 27V-45V fOpeiatingrange 16V-48V � 16V-60V _ Min/Maz start voltage 22 V / 48 V 22 V / 60 V Max ITCshort circuitcurrent(module Isc) 15-A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+Microlnverter Peak output power 250 VA 295 VA - _ _ - _ Maximum continuous output power 240 VA 290 VA IJominal (L-L)voltage/range' 240V/ 208V/ 240V/ 208V/ ; - 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominaffrequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.9 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvol{age class AC port '- --- In ---- - -- -- --- - III ---- -- - -- --- -- - - - - AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 , Power factor (adjustable) 0.85 leading... 0.85 lagging O.SSleaciing... O.BSlagging ._ __1._..._._.._, _,._ ._ _.._ ._ _.._ ... _.._ ._ CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % - Ambient temperature range -400C to +65°C Relative humidity range 40/. to 100 % (condensing) Comrectortype (IQ7-60-2-US & IQ7PLUS 72-2-US) MC4 (or Arrphehol H:f UTX with additlonal Q-DCC-5 adapter) ' Connector type(IQ7-60-6-US&IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 D_imen_sicns (WxHxD) _ _ . 212 mm x 175 mmx 30.2 mm (without -bracket) _ _ .... Weight _ _ _ 1.08 kg (2 lbs) Cooling IJatural convection - No fans Approved for wet locations Yes Pollution degree P63 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure ---------- ------- Eriviionmenfal category / UV exposure rating --AType6—utdoor ---------- - -----'------ - -'- -- -- - NEMA Type 6 /outdoor _ FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. I blsconnectina means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at httos-//ennhase com/en-us/support/module-comoat h'I'ty. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com u E N P H AS E. © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19 A SOLAR PV SYSTEM IMPROVEMENT FOR: RECEIVED , LANGER RESIDENCE FEB 2 7 0 i ST. LUele 5t. tic(Oa1Mj yK m�11cH SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS�ir�c� vmf,�'�` FOR inc EXISTING RESIDENTIAL GRID TIED ELECTRICA' VICINITY MAP wfliveto" _.—Vem Beach -;1-.rnamr i- seuu: O'•, PROJECT SITE LOCATIM, 1 FORSOLARIMPROVEMEMR ll Ili FS noon a _ I msiwlia. WQQ. Ann CaLin SYSTEM INDEX SHEET DRAWING NAME CV COVERSHEET SLRI SOLAR SYSTEM EQUIPMENT LOCATION PLAN PVR-SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS -------- APPENDIX-------- HB1021 NEW PROVISION + LETTER CANADIAN SOLAR 325W MODULE DATA SHEET ENPHASE IQ7+ MICROINVERTER DATA SHEET L ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: DATE: �� ELE a 2 PLUMB: I PROJECT: I 0 u Wz za W Z cy W_ K LL W�7, P 0 z a w C Q LL ¢S ui K W W d a O O (n 1 1 LL DATE 2/24/2020 DRAWN BY: 11A CHKD BY: JIA REC. NO. # 29127 SCAIE AS NOTED DRAWING # 31 APPROXIMATE LOCATI PENETRATION TO 2'-0" SYP 2017 FBC SEE SHEET P IRONRII Pi MODUI ROOFTO APPROX FORS IRONRIL RI MODUI WINDZI APPROXIMATE LOCATION OF ENPHASE ENVOY Q COMBINER BOX )OR EQUAL) APPROXIMATE LOCATION OF AC DISCONNECT LOCATED OUTSIDE AS SHOWN. SEE SHEET SLR2 FOR DETAILS. APPROXIMATE LOCATION OF EXISTING ELECTRIC METER/MAIN DISTRIBUTION PANEL (30) CANADIAN SOLAR 325W MODULES W/ (30) ENPHASE IQ7+ MICROINVERTERS (15) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (9) l l' XR100 RAIL (6) 14' XR100 RAIL (5) 17' XR100 RAIL (10) XR-100 INTERNAL BONDED SPLICE KITS (4) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER (80) WIRE MANAGEMENT CLIPS (65) IRONRIDGE STANDOFF W/ (2) LAG SCREW (16) IRONRIDGE UFO SLEEVES (16) IRONRIDGE END CAPS FOR RAILS (86) IRONRIDGE GROUNDING UFO CLAMPS (30) LANDSCAPE OR PORTRAIT ENPHASE ENGAGE CABLE CONNECTORS (3) ENPHASE 6 FT EXTENSION CABLE (3)ENPHASE END CAPS (1) NEMA 31? RATED ROOF MOUNTED JUNCTION BOXES DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. ROOF LAYOUT NOTE: N SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL _- RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND .D SZONE 3 AREAS. SCALE: N.T.S. i I PROJECT: 0 O v W Z z z za w wz W In W w � O O CD z P w d y � w w w $a p w N ` < w r z: a u N H N W � w w d_ O _ F- ti O d a w DATE 2/24/2020 DRAWN BY: 1LA CHKD BY: 11A REC. NO. # 29127 SCALE AS NO1ED �aa �IIII \ A y LT1BECNg i �� S � 0 30 lzi OHP � 'E ///XTI NALL\X\\. PHOTOVOLTAIC MODULE GENERAL NOTES: I. APPLICABLE CODE: 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) & ASCE 7.10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7" TO A MAXIMUM 27" (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. RESIDENTIAL ROOF SHALL NOT EXCEED 30'.0" MEAN ROOF HEIGHT. FIELD VERIFY. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAI4 ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-75 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL 39" X 65" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. ALL SOLAR RAIUNG AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) OR LOCAL GOVERNING CODE. ULTIMATE WIND ZONE MAX WIND ZONE 2 MAX WIND ZONE 3 MAX EMBED. WIND SPEED SPAN, MAX SPAN, MAX SPAN, MAX DEPTH Vm(MPH) CANTILEVER CANTILEVER" CANTILEVER" REQ. 160 6'-0" O.C., 2'-4" O.C. 4'-0" O.C., I'-7" O.0 2'-0" O.C., 9" O.C. 3"' - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "D", RISK CATEGORY II , ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.B.C. * LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. "3RD RAIL IS REQUIRED PER ROW OR COLUMN FOR SPECIFIED ROOF ZONE. a DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2017 FLORIDA RESIDENTIAL CODE j6TH EDITION -------------------------- — — — — i i 1 ' GABLE END BUILDING Cl HIP END BUILDING ROOF i ROOF WIND AREA ZONES WIND AREA ZONES i .--------- _t---- ---_—_--___—' _..__._. L TYPICAL PHOTOVOLTAIC -ARRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN SCALE: NONE TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN %i�\ SCALE: I6"=1' 0" RE -FILL PER MODULE ARRAY AND BE CONNECTED LESS THAN 25% OF MODULE LENGTH IN ROOF ZONE 1. IN ROOF ZONES 2 & 3, THREE (3) RAILS ARE REQUIRED PER MODULE ARRAY. USE ANTI -SEIZE AND TIGHTEN TO TORQUE PHOTOVOLTAIC PER MANUF. INSTRUCTIONS OZN, MODULE TYP. REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH p0 LABELED "X" IN THIS DETAIL. Y S�bpE 1 IRONRIDGE XR 1000 ALUM. L-FOOT OR XR100 ALUM. FASTENED TO RAIL W/ SOLAR RAIL TYP. 3/8-1 S4 STL. ��FLAT TYP. R BARRELTILE BONDING BOLT H: NUT ROOFING WOOD SHEATHING IRONRIDGE RAIL (2) �y' ST STL LAG BOLT. SEE SCH FOR EMBED DEPTH REQ. TYP EACH STANDOFF 12" ALUMINUM INTERNAL SPLICE BAR (USE WHEN SPLICE AT MID -SPAN W/ 0 0 o (4) #12-14x8' ST STL SELF TAPPING SCREWS TYP IRONRIDGE XR1000 OR XR100 #12-141r" ST STL SELF TAPPING ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE TYPICAL SOLAR RAIL BEAM SPLICE DETAIL PV MODULE FRAME IRONRIDGE UFO CLAMP TYPICAL PV L-FOOT CONNECTION DETAIL SCALE: 1 2"=1' 0" WOOD ROOF IRONRIDGE TRUSS TYP. UFO CLAMP IRONRIDGE ALUMINUM STANDOFF STOPPER SLEEVE ASSEMBLY TYP. PV MODULE FRAME 3" B MID CLAMP - PLAN END CLAMP - PLAN IRONRIDGE UFO CLAMP PV MODULE FRAME IRONRIDGE RAIL MID CLAMP - SIDE — IRONRIDGE UFO CLAMP END CLAMP - SIDE END & MID CLAMP CONNECTION DETAILS SCALE: 3"= PV MODULE FRAME IRONRIDGE STOPPER SLEEVE IRONRIDGE RAIL I PROJECT: I F AA27D DRAWING # ,P,kR+SS 77, �NAL 'OWER TABLE: SYSTEM I SYSTEM B SYSTEM UtNtKAL PHOIUVULIAIL- J-LINE DIAUKAM JYtUI-K- VLAU r, DC -SIDE A B C 1 ST BRNCH C 2ND BRNC C 3RD BRNCH AC -SIDE OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK t PV MODULE 1 1 13 11 6 INVERTER MANUF CANPDIFN sown ENPHASE-I07+ EQUIPMENT SHALL BE INSTALLED PER THE 2014 NATIONAL ELECTRICAL CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY. MODEL CSIH-325MS 295 W 3635 W 3245 W 1770 W PEAK POWER POWER 325 Wdc 290 W 3770 W 3190 W 1740 W CONT. POWER LISTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC VOC 43.4 VDC 240 VAC 240 VAC 240 VAC 240 VAC VOLTAGE 110.3(B). ENPHASE MICROINVERTER SYSTEM IS RAPID SHUTDOWN COMPLIANT PER NEC 690.12. ISC 9.65 A 1.21 A 15.73 A 13.31 A 7.26 A CURRENT VMP 35.8 VDC 60 HZ 60 HZ 60 HZ 60 HZ FREQUENCY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY 4 TOTAL VOLTAGE DROP OF 2%OR LESS PER INVERTER MANUFACTURER. IMP 9.09 AMP STG CELL TEMPERATURE @ 25" C, SPECTRUM AM1.5, IRRADIANCE @ 1000 W/M2 S�IABEL DEVICE PER NEC 690.14(CJ(2), AND SECURE PER NEC 690.7(D). NEC ZL LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. %// Q?s' Oo oo 11� 93 e PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR EQUAL TO 120%OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12. ENPHASE Q CABLE SHALL BE KEPT 2" ABOVE ROOF SURFACE MINIMUM gENPHASE Q CABLE SYSTEM DOES NOT CONTAIN A NEUTRAL AND IS NOT REQUIRED I MANUFACTURER. I07+ MICROINVERTER DOES NOT REQUIRE EQUIPMENT BONDING FOR GROUNDING. SEE MANUFACTURER'S INSTALLATION MANUAL FOR DETAILS. I PROJECT: I DATE 2/24/2020 DRAWNBY: JIA CHKD BY: I JIA RK NO. # 29127 SCALE AS NOTED Big O�S(�LR2A J , SHFET-'�IS A/V OF "' AUDiNor KoE. suo �r, . r x !" JOHN PNNN[itlp a^i j FL 01305 we /oNAk- �/llllll\\`