Loading...
HomeMy WebLinkAboutProduct Approvala I y. no 3e2�.f.,y{n"t'.aU��i�w'a 0-1 4 TM j„s acts Home Lag In User Registration Hot Topics Submit surcharge Scats 6 facts Publications Fac Starr aCIS Site Map U." Search dbpr prod USER: En,,,.�A ip.aial H.na > Pmduu n, ARoI¢aUon Search > appl¢arvcn L., > Application Detail uct Approval Public User FL # ( FL17443-RI Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method I A TAYLOR ROOFING 302 Melton Drive FT PIERCE, FL 34982 (772)466-4040 kylewhite228@aol.com Kyle Taylor kylewhite228@aol.com RECENED MAR 16 2020 Permitting Department fit, LwH In County REVIEWED FOR CODE COMPLIANCE ST. LUCIE/�COUNTY BOCC Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Locke Bowden Evaluation Report Florida License PE-49704 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/23/2023 Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Receivetl Certificate of Independence FL17443 RI COI FL 17443 I A Taylor 2017 Cade Eva] Report with Details RSS5.pQ Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 FILE COPY .2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL # �17443.1 Model, Number or Name 5 V Crimp Method 1 Option O 01/24/2018 02/14/2018 02/17/2018 04/10/2018 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-129.25 Other: -129.25 @ 6" o.c. -69.25 @16" o.c. margin of safety 2:1 with 24" max. coverage Install per manufacturers detail. Not for use in HVHZ. Description 26GA 1/2" rib height over 15/32" APA plywood Installation Instructions FL17443 RI 11 FL 17443 1 A Taylor 2017 Code Eva] R=_port with Details R S4pd( Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17443 RI AE FL 17443 3 A Taylo 2017 Code E al Re nl with Details RSSS.ILdf Created by Independent Third Party: Yes 17443.2 VICTORIAN CRIMP SHINGLE 26GA 1/2- RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER CDX/APA 15/32e PLYWOOD Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-105 Other:-105PSF margin of safety 2:1. Install per manufacturer's details and in compliance with FBC 2017 6th ed. Not for use in HVHZ. 0 Installation Instructions FL17443 RI II FL 174431 A Taylor 2017 Code Eval Repor with Details RSSS.pd[ Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL 17443 RI AE FL 17443 1 A Taylor 20L7 Code Eval Repyrt with Details RSSS.pjf Created by Independent Third Party: Yes Contact Us:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 650-487-1824 The State of Florida is an AA/EEO employer. fpineight 2007-2013 State of Florida.:: Privacy Statement:! Accessipiliw Statement - Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), narlda Statutes, effective October 1, 2012, licensees hoi n cd under Chapter 455, F.S. must provide the Department with an email address if they have one. The emais provided may be used for official communication with the licensee. However email addresses aft public record. If you do not wish to supply a personal address, please provide the Department with an email address which on be made available to the public. To determine if you are a licensee under Chapter 455, F.S. please dick here . Product Approval Accepts: 01 ® r'h.l Is Credit Card Safe Fort Pierce, FL 34962 (772)466-4040 Compliant with Florida Building Code 2017 (6` ed.) Compliant with Florida Product Approval Rule 4 61G20-3 Compliant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY FBC Sections: 1504.3.2.1507 5V Crimp thru fastened A" rib at each panel edge and 1 fastener in the center of the panel, 24" net coverage, 26GA ASTM A792, G-50, AZSS, .018, 50ksi min. over min.15/32" thick CDX plywood deck. Corrosion Resistant fastener p9-15 HWH with sealing washers, metal to wood connections with fastener length to penetrate 5/16" thru substrate. Fasten along the crown of the rib in the center of panel and along the lap. First fastener to be within 3" of panel edges. Min. 8Dx2" annular ring shank nails spaced 6" O.C. reroofing, with less than 19/32" plywood (min.15/32" ), this attachment is to be used in addition to existing attachment. Deck slope 2:12 or greater and shall be cam pliant with FBC 2017 6T" ed. Underlayment: See FBC 2017 6T" ed., Sec. 1507 Table 1507.1.1 ••Design Pressure: Spacing: -69.25 PSF 16" O.C. -129.25 PSF 6" O.C. Z6GA ASTM A792, G-50, AZS5, .018, SOksi Victorian Crimp Shingle over 15/32" COX/APA Plywood attached to roof trusses. Corrosion Resistant Fastener #10 x 1" Zinc plated, MTW Pancake Head, installed at 2 per panel into lock seam. Panels applied with 12" exposure, adjacent shingles inserted into lock seam of previous shingle. Deck slope 2:12 or greater and shall be compliant with FBC 2017 6" ed. Underlayment: See FBC 2017 6T" ed., Sec.1507 Table 1507.1.1 ••Design Pressure- 105 PSF --uproar rnn5urtt !!YCLUDE5A5AFETs.'.MARGJNOF2.1 Reference Data: TEST REPORTS Hurricane Test Laboratory (TST-1527) 90224-0501-06 TAS 125 JUL 580.941) PRI Construction Materials Technologies (TST-5878) NFAE-023-02-01 UL 580-06/UL 1897-042 1. UL 580-94 teststandards are equivalent to UL 580-06 test standards. 2. UL 1897-04 test standards are equivalent to UL 1897-12 test standards. 1. V Underlayment to be compliance with current Florida Building Code (FBC)2017 6T" ed.. see Chart 1507.1.1 2. Minimum slope to be compliant with Florida Building Code 2017 6`h ed., and per with Manufacturer's installation reference. 3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-0 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC2017 0 ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturin�Q{!�l)))buting products under this evaluation. s"•`stt B0�/nnrrrrrrry report.cke owden, P.E. is not owned, operated, or controlled byany company, manufacturer, o: r w totitj<t ittwo this • 0 seal 140. Sj PjE Q FLOR\� SSIONP�, ruuutttatt 5 V Crimp Fastener- #9-15 corrosion resistant w/sealing washers 24" coverace Fastener: #9 x 15 corrosion resistant with sealing washers in Compliance with 2017 Florida Building Code, Section 1507 Perimeter fastening: 6"o.c. Main Field fastening 1 2"o.c. Panel Width: 26" Panel Coverage: 24"maximum 26 GA Architectural Metal Roof panel VICTORIAN CRIMP LOCKSEAM MINIMUM 2 FASTENERS Fastener.#10x 1" AT LOCK SEAM Zinc Plated MTW Pancake Head FIELD CUT 1/2 SHINGLE TO CREATE STAGGERED PATTERN VICTORIAN CRIMP SHINGLES t i � w U) 0 a w I N I 9"EXPOSURE