HomeMy WebLinkAboutNew Shed engineeringSETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 A CHORI G TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 s -e 13'-8" 280 3'-0" 11'-81" 240 3'-0" 10'-0" 200 3 6" 8'-01' 160 3'-0" 6'-0" 120 3'-0" *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" SKIDS ONLY. 13* -8" WIDE SHEDS HAVE (4) SETS OF SKIDS. T 30" AUGER ANCHOR (4,900LB) INSTALLED PER MANUFACTURER'S INSTRUCTIONS. EYELET AT MAXIMUM OF 6" ABOVE GRADE. SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1� x44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A TABLE 2 SKID RUNNER SPACING* SHED WIDTH X1 X2 X3 MATERIAL 1'-104" V-104" 1 _16}" II 4"x8"x16" 3500LBS 2'-8" 6'-4" - 10'-0" V-7" 6'-10" - 8'-0" 0'-9" 6'-6" - 6'-0" 0'-10" 51" - *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" SKIDS ONLY. 13* -8" WIDE SHEDS HAVE (4) SETS OF SKIDS. T 30" AUGER ANCHOR (4,900LB) INSTALLED PER MANUFACTURER'S INSTRUCTIONS. EYELET AT MAXIMUM OF 6" ABOVE GRADE. SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1� x44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS PAD TYPES LW* TYPE PAD DIMENSIONS MAX. LOAD* MATERIAL I 2"x8"x16" 1778LBS CO CTLOCK QUALITY CEMENT AND SAND MIX II 4"x8"x16" 3500LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX III 16"06" 3950LBS ABS PLASTIC PADS IV 8"x8"x16" 190OLBS CO CRETE BLOCK QUALITY INTERIOR PAD IX CEMENT AND SAND. Me BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"xW) MAY BE STAKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8" AND 13'-8" WIDE SHEDS ONL9. * LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP -1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION LW* PAD INTERIOR SPACING*** MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW*(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW 4.15/332 0" TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV 11'-8" SW/DW 6.00/480 0" TO 6" 6'-0" 2558LB I, 11, III, OR IV 2558LB I, II, III, OR IV I UPLIFT (PLF) SW/DW 5.00/400 Cr TO 6" W-0" 2400LB I, II, III, OR IV 2400LB I, II, III, OR IV 5'-0" SW 4.00/320 0" TO 6" 6'-0" 2029L8 I, II, III, OR IV 21331_8 I, II, III, OR IV SW 3.00/240 0" TO 6" 6'-0" 1658LB 1, II, III, OR IV 1866LB I, II, III, OR IV * LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP -1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. * LOAD WIDTH OF UPLIFT ON RUNNER ** LOCATION FROM END WALL OF AUGER ANCHOR *** MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. 3, THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER, ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** NONE 7.00 243 0'-0" TO S-0" 10'-0" 11'-8" 6.00 208 Y -o" TO S -O" 10'-0" 10'-0" 5.00 174 V -d' TO 3'-0" 10'-0" 8'-0" 4.00 138 0'-0" TO S -O" 10'-0" 6'-0" 3.00 104 U -Cr TO 3'-0" 10'-0" THRU 2"x4" BOTTOM PLATE OPTIONAL FOR "HIGH SET" BOLT & NUT WITH (2)2"x2" GALVANIZED TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW* I UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** 20'-0" 10.00 1 400 1 O'-0" TO 3'-0" 1 5'-0" * LOAD WIDTH OF UPLIFT ON RUNNER ** LOCATION FROM END WALL OF AUGER ANCHOR *** MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. 3, THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER, ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. CODE VERSION FBC 2017 88, EdBbn /SCE 7 �MAIUFACTURER SUPQigR s1ED5 BUILDING TYPE RE_ T9.-..0 --.Sf6WAGE CONSTRUCTION TYPE 2"x2" GALVANIZED WASHER FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE 2"x2" GALVANIZED WASHER STORAGE WITH 1/2" NUT I 1/2" THREADED ROD "HIGH V+-180mph SID. 78PSF - 128PSF OPT. WITH 1/2" NUT N/A MODULES PER BUILDING 1 OPTIONAL FOR SET" NO NOTCH OR COUNTERSINK BOLT 1/2" THREADED ROD SQUARE FOOTAGE EYES BOLTED TOGETHER WITH 1/2"x2" THRU 2"x4" BOTTOM PLATE OPTIONAL FOR "HIGH SET" BOLT & NUT WITH (2)2"x2" GALVANIZED " 1/2COUPLER 2'x4" BOTTOM PLATE NAILED 1/2" COUPLER _ WASHERS (2.000LB SHEAR CAPACITY) _ 1/2"x5" (400 LB.) CONCRETE TO 2"x6" P.T. BASE 1/2"02" FORGED EYEBOLTxq " MIN. WEDGE ANCHOR INTO SLAB THRU 2"x4" P.T. BOTTOM PLATE -------- f" MIN. I (SEE TABLE 1 FOR SPACING) 1d---�----°------ EYES BOLTED TOGETHER WITH " BOLT NUT WITH (2)2"x2" GALVVANIZEANIZED TYPE 1, II, III, OR IV PAD WITH � BLOCKING AS REQUIRED (SEE TABLE 3). 1/2"x3" (400 LB.) SIMPSON A-24 CONCRETE SLAB BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES AND JURISDICTION WASHERS (2.000LB SHEAR CAPACITY) � CONCRETE WEDGE ANCHOR CLIP OR EQUAL LOCAL CODES AND JURISDICTION (SEE TABLE 1 FOR SPACING) 30" EARTH AUGER ANCHOR (SEE TABLE 4 FOR SPACING) SHED WITH SKID SHED WITH 'NO FLOOR' OPTION SHED WITH SKID ANCHORED TO CONCRETE ANCHORED TO CONCRETE TO PAD OR BLOCKING TIE -DOWN DETAILS CODE VERSION FBC 2017 88, EdBbn /SCE 7 �MAIUFACTURER SUPQigR s1ED5 BUILDING TYPE RE_ T9.-..0 --.Sf6WAGE CONSTRUCTION TYPE V-8 FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES I BASIC WIND SPEED V+-180mph ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1.18 ROOF DEAD LOAD IOPSF ROOF LIVE LOAD 2OPSF OR 3DOlbe FLOOR DEAD LOAD BPSF FLOOR LIVE LOAD SID. 78PSF - 128PSF OPT. "R" RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LESS THAN 720 SOFT• DESCRIPTON 2017 FOC GROUND ANCHOR S" AF.G MAK, ANCHOR EXTENSION GO MTB 0 Date: Ld 4/26/16 = Seale: Cn NA odel LLQ ALL 0 GENERAL NOTES 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. L1_I 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION J 1015.22. M 3. REFER TO TIE -DOWN DETAILS FOR PROPER i--) INSTALLATION REQUIREMENTS TO MEET CODE. 0 0 0 1/9/19 I— Q Matthew T. Baldwin P.E. Florida License #64608 cf' Z Sheet: AD -1 OF 1 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN #SS -B -180-C D4 ALUMINUM ROOF SHEATHING 2" BLOCKING 2" SOLE PLATE FLOOR FRAMING DESIGN PRESSURES ROOF +27.8/-94.71 R00F FRAMING PLAN WALLS/DOORS/WINDOWS +32.6/-29.2 ELEVATION CROSS—SECTION TYPICAL ARCH FRAME MOR�D l 4 �N� U -U MAX. V -B Zr MAIL NONE 2x4 SN NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES 2x4 BLOCIONG O BASIC WIND SPEED 24. O.C. Sm. 76PSF - 126PSF OPT. "R" RATING OF WA -LS. FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE END WAILS SQUARE FOOTAGE 719 SQ.Fr. OR LESS REVISIONS I O H g 2.4 SOLE PLATE \_1x4 RUNNERS 0 I In W J END WA TRUSS LxJ •'ITd6 6'-0� TO 13'-8" 2"x4" TRUSS 0 24" O.C. MAX. K24 OR EWIVMENr. SEE WITH DOOR TABLE 2 FOR QUANTITY AND END RUSS 2" BLOCKING 2" SOLE PLATE FLOOR FRAMING DESIGN PRESSURES ROOF +27.8/-94.71 R00F FRAMING PLAN WALLS/DOORS/WINDOWS +32.6/-29.2 ELEVATION CROSS—SECTION TYPICAL ARCH FRAME MOR�D l 4 �N� WITHOUT DOOR END ELEVATION WITH GARAGE DOOR (ONLY ON ENDWAUJ Side Wall Header Schedule 1180C) Building Width Fasteners w/ strap Size Up to 14' Wide (each end) Max. Span NJ{b} 1-41"x4" 6'-0" 0 3 - 3" x 0.131" nail< 4"x4" w2"x4" 8'-0" 1 6 - 3" x 0.131" nail a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber. b NJ - Number ofjack studs required to support each end. c. Window header for window openings that have more than 50% combined stud wall above and below, otherwise use door header schedule. d. See header details for alternate layouts, i e. 2-2"x4" or 4"x4" P.T. e The header can be attached to the top plate and thus have the combined strength equivalent and use the maximum span stated. WALL 12-x12- OR 16"x4" BETWEEN To �A STUDS. AS PER SEW RED WANUFACNRERS NsvRucnoNs HYDROVENT DETAIL (OPTIONAL) (2) 2"x4" WITH 1/2 PLYWOOD OR osB nu.ER OR (1}/•.4' 12" MAX. SIDE WALL WINDOWS & DOORS End Wall Header Schedule (180C) Sized} Max. Span NJ[b} Fasteners w/o strap (each end)[c}_: 1-7'W 6'-O' 0 4 - 3" x 0.131" nails Q'_1. 1 nm1 1 6 - 3"x 0.131" nails a. Tabulated values are for NO. C grade Jpruce-F'Ine-rlr lumber. b. NJ - Number ofjack studs required to support each end. c Laid flat d. No Jack studs, but 2x6 studs laid flat. 1. SEE FASTENER SCHEDULE FOR HARDWARE REOUIREMEHIS, 2, SEE HEADER SCHEDULE FOR ADDITIONAL INFOR TxxN. 3. WNDDW HEADERS HAVE COMBINED 00% OR CURE WALL FRAMING ABOVE IND BELOW. OTH SE REFER TO DOOR HEADERS. SINGLE 2".4" HEADER END WALLS WINDOWS & DOOR 6' WIDE OR LESS G.F.I. �+ NOTES -OPTIONAL ELECTRIC OUTLET -ALL WIRING SHALL BE 14 CAGE 3 -WIRE MC CABLE. N II -ENCASE IN ALL METAL BOXES. SOURCE L " WIRING DIAGRAM (OPTIONAL) END WALL SEE HEADER DETAIL 1.4 RUNNER ON INSIDE 2.4 ST11 24' OF_ ALL STUDS SECURED TO SOLE PLATE AND FLOOR FRAMING WITH 0.039" (1mm).W STRAP W/6-108 NAILS OR EQUAL A WINDOW LOCATIONS VARY 2 4"x4" W/2"x4" . William E. Neary, III SNIP -51, SlAI--79, ICC 5185040 10629 Oak, ell Pointe terrace C:r tha, (IDFida 34734 D4 ALUMINUM WNL SHEATHING OPTIONS WAIL 2.4 SOLE PLATE FLOOR FRAMING STANDARD WALL DETAIL NOTE. WALL FRAMING MEMBERS ME CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECUREp��p ENSURE A WITH DOOR & WINDOW OPTIONS C2tntua!S LOAD PATH. WHERE 1rALL A1gIBOIS ARE ..— ��..... ... .IES. OR CUPS )F NOT LESS FLOOR FRAMING PLAN ITa _ v =m mond v W ++ Y ia' woF TWE (47 g15 6 9ms P.T. 24. O.C. TYP. ZONAL 125PSF O 16" OX. WITH 3/4" T3G PLYBDARD 4" P.T. ATTACHED WITH l OR EQUIVALENT. SEE EE 2 FOR QUANTITY AND ,aNG. CODE VERSION IM14 NIN M U.- Asp 7� FBC MANUFACTURER SUPERIOR SHEDS BUILDING TYPE RESIDENTIAL LA1 V STORAGE CONSTRUCTION TYPE V -B Zr MAIL NONE 2x4 SN NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES 2x4 BLOCIONG O BASIC WIND SPEED 24. O.C. Sm. 76PSF - 126PSF OPT. "R" RATING OF WA -LS. FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE END WAILS SQUARE FOOTAGE 719 SQ.Fr. OR LESS REVISIONS g 2.4 SOLE PLATE LxJ •'ITd6 6'-0� TO 13'-8" END ELEVATION 4'x4' P.T. ATTAa¢D WITH K24 OR EWIVMENr. SEE WITH DOOR TABLE 2 FOR QUANTITY AND WITHOUT DOOR END ELEVATION WITH GARAGE DOOR (ONLY ON ENDWAUJ Side Wall Header Schedule 1180C) Building Width Fasteners w/ strap Size Up to 14' Wide (each end) Max. Span NJ{b} 1-41"x4" 6'-0" 0 3 - 3" x 0.131" nail< 4"x4" w2"x4" 8'-0" 1 6 - 3" x 0.131" nail a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber. b NJ - Number ofjack studs required to support each end. c. Window header for window openings that have more than 50% combined stud wall above and below, otherwise use door header schedule. d. See header details for alternate layouts, i e. 2-2"x4" or 4"x4" P.T. e The header can be attached to the top plate and thus have the combined strength equivalent and use the maximum span stated. WALL 12-x12- OR 16"x4" BETWEEN To �A STUDS. AS PER SEW RED WANUFACNRERS NsvRucnoNs HYDROVENT DETAIL (OPTIONAL) (2) 2"x4" WITH 1/2 PLYWOOD OR osB nu.ER OR (1}/•.4' 12" MAX. SIDE WALL WINDOWS & DOORS End Wall Header Schedule (180C) Sized} Max. Span NJ[b} Fasteners w/o strap (each end)[c}_: 1-7'W 6'-O' 0 4 - 3" x 0.131" nails Q'_1. 1 nm1 1 6 - 3"x 0.131" nails a. Tabulated values are for NO. C grade Jpruce-F'Ine-rlr lumber. b. NJ - Number ofjack studs required to support each end. c Laid flat d. No Jack studs, but 2x6 studs laid flat. 1. SEE FASTENER SCHEDULE FOR HARDWARE REOUIREMEHIS, 2, SEE HEADER SCHEDULE FOR ADDITIONAL INFOR TxxN. 3. WNDDW HEADERS HAVE COMBINED 00% OR CURE WALL FRAMING ABOVE IND BELOW. OTH SE REFER TO DOOR HEADERS. SINGLE 2".4" HEADER END WALLS WINDOWS & DOOR 6' WIDE OR LESS G.F.I. �+ NOTES -OPTIONAL ELECTRIC OUTLET -ALL WIRING SHALL BE 14 CAGE 3 -WIRE MC CABLE. N II -ENCASE IN ALL METAL BOXES. SOURCE L " WIRING DIAGRAM (OPTIONAL) END WALL SEE HEADER DETAIL 1.4 RUNNER ON INSIDE 2.4 ST11 24' OF_ ALL STUDS SECURED TO SOLE PLATE AND FLOOR FRAMING WITH 0.039" (1mm).W STRAP W/6-108 NAILS OR EQUAL A WINDOW LOCATIONS VARY 2 4"x4" W/2"x4" . William E. Neary, III SNIP -51, SlAI--79, ICC 5185040 10629 Oak, ell Pointe terrace C:r tha, (IDFida 34734 D4 ALUMINUM WNL SHEATHING OPTIONS WAIL 2.4 SOLE PLATE FLOOR FRAMING STANDARD WALL DETAIL NOTE. WALL FRAMING MEMBERS ME CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECUREp��p ENSURE A WITH DOOR & WINDOW OPTIONS C2tntua!S LOAD PATH. WHERE 1rALL A1gIBOIS ARE ..— ��..... ... .IES. OR CUPS )F NOT LESS FLOOR FRAMING PLAN ITa _ v =m mond v W ++ Y ia' woF TWE (47 g15 6 9ms P.T. 24. O.C. TYP. ZONAL 125PSF O 16" OX. WITH 3/4" T3G PLYBDARD 4" P.T. ATTACHED WITH l OR EQUIVALENT. SEE EE 2 FOR QUANTITY AND ,aNG. CODE VERSION IM14 NIN M U.- Asp 7� FBC MANUFACTURER SUPERIOR SHEDS BUILDING TYPE RESIDENTIAL LA1 V STORAGE CONSTRUCTION TYPE V -B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES I BASIC WIND SPEED V_IBOmph ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1-15 ROOF DEAD LOAD IOPSF ROOF LIVE LOAD 3OPSF OR 30011, POINT LOAD FLOOR DEAD LOAD IOPSF FLOOR LIVE LOAD Sm. 76PSF - 126PSF OPT. "R" RATING OF WA -LS. FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 719 SQ.Fr. OR LESS REVISIONS w MTB Z Date: J 12/12/17 Z 0 Scale: NA Cn W oriel Z ('0 SS -B -180C LJJ 1. FOUIDA PLANS ARE NOT PMT OF THIS PLAN SET AND ARE a- F__ DN G`VED BY LOCAL JUMSDICTON. Z. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION LJLi CODE PER SECDO 1015.22. 3 REFEA TO TIE- DETAILS FOR PROPER INSTAL . QREQUIREMENTS TO CODE 4. ALL STUDS, RAFTERS, TRUSSES, ETC. ME 2.4 /2 SPF. EXCEPT O AS NOTED. U 5. STRUCTURES OVER 400 SQ. FT. WILL RAVE M 00" MINIMUM DOOiL Lw 6. CGUTTERS TO BE INSTALLED ON-SIrE BY OTHERS THRU LOCAL (n O 7. AL WINDOWS AID DOORS TO MEET THE MINIMUM SPECIFICATIONS `i AS PER FLORIDA BUILDING CODE B. FAIT METAL STRAP` CAN BE BEM MOUND STRUCTURAL MEMBERS OF ALL SKIDS, TRUSSES. CHORDS, ETC. TO HELP SECURE THEE M BERS; PROVIDED THAT THE ADDED BEND DOES NOT INTERFERE *rrH ANYIXISTI G BRAKES/BENDSI THE STRAP. z fill A, •\-\CENSE LLJ . Q� I � i �•'t STATE t i•. OF �•. _L0RIDP •' �` J �� 11/lll)11 Q O Matthew T. Baldwin P.E. CD Florida License #64608 M Sheet: SSB -1 OF 1