Loading...
HomeMy WebLinkAboutDocument1 (2) JOSEPH E . SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 4705294 OR BOOK 4416 PAGE 2315 , Recorded 05/05/2020 04 : 09 : 54 PM 1075167 NOTICE OF COMMENCEMENT Permit No. Property Tax ID No. 2405-717-0006-000-2 State of Florida,County of St.Lucie The Undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. Legal Description of property and address if available TRADE WINDS S/D LOT 6(0.19 AC)(OR 363-1840) 3510 METZGER RD FT PIERCE, FL 34947 General description of improvements REROOF Owner/lessee CLAUDIA CUNNINGHAM Address 3510 METZGER RD FT PIERCE,FL 34947 Interest in property: OWNER Fee Simple Title holder(if other than owner) N/A Address N/A Contractor FHIA LLC Phone# 954-792`4415 Address 3044 SW 42ND ST FT LAUDERDALE,FL 33312 Fax# Surety N/A Phone# Address NIA Fax# Amount of Bond N/A Lender N/A Phone# Address NIA Fax# Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(a)7.,Florida Statues: Name WA Phone# Address NIA Fax# In addition to himself,owner designates NIA of Phone# Fax# to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Expiration date of notice of commencement is one year from the date of recording unless a different date is specified. WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CH.713.13,F.S.,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDER AND POSTED ON THE 30B SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCMENT. Owner/Lesse or wner's of Lessee's Authorized Ofricer/Direetor/Partner/Manager/Signature Signatory's TitlelOffiee State of Florida,County of Acknowledged before me this day ofAIL � 20 ,by V— ona y wn to me or who has produced as identification. � �""� �l►t+XAUs MANUELHERNANt1EX Signature of Nota Type or Print Name of Notary ' Sealt, e+ssEon#GG f}Q491$ Title:Notary Public Commission Number /�Z 2G�p '�aFxti4� Isa,Paa srsu suO,eiuo#aryw4 AIII AIPPLICAIBLE IN Ftl N UST BI dCIMII I ETE13 FOR APPI ICATICIAI 7Q BE ACCEPTED Dale: Pejimit Number: .] t Buildirid Pellrr ill Application Planning and Demlol1ment Surukas Auilding acid Carle Ragluki tian Diuhsion 3300 W iginlai Aveinua, Fart A ienis F1 341182 1l ana: (Y:) 4(1;-1153 kx: (772) 461-1M COnr me19Cial ResidElntia) X PERMI1 TVE: RC GRIN Cl PROPOSBCI IN PRO\ EN EN n LOICA11ION: Alddress: 351a MHTZGER RD"P13RCE Proper't) Ta)i 11 #I: 2403-717-OOOC-00a-2 Lol No. 9ile Flan Name: . Black No. l roje a I Na nl EI : 1135161 C:UNNINCFA N El EVII 11 E MISC►MP11ON OF WORK: RERCxIR SHINGLU ANC FLf T Fcoh S-nF L MON INFORMATION: Additional uric rl to be p erfa rmed r nds n this perm it—the f' all tl at a I�Illy: —MeliIanicaI �GasTanI _Clan RipingShutters �Wiridolnls,IDoors _Nlecisic �Rlcrnking _9grinl16r� _Generator X Rool Rit(if Total Sq. It oil Conatuuction: sq. P. oil First Illoor: Ca st o"I Constnuction: $ Utilil ie.i: ,9ewea -septic Building HE ight: OM EAIJLESSE E: CION 11 RA C1 OR: Name Name: Addne!i Comps n rl: City: :Itale:— Addae:is: Zip Code: Fa)r City l: S1 al a: 111 ore Na . it ip Code: _ Fa)i: 9-i4 ail: Ric ne No Fill in fea simple Title Holden on next page(if cIifleiient 9-I4 ail from ihe0minerlisred above) 31aIa ortla tin tyIWense 1f value oil aonatruc ion is',I;500 oa mose,a RECCIRDID Nol ice oil to rr meaaeme n t is required. 111 ualue of HVAC is 13,501 or more,a RECORDED Noliae o1 Ca rrimenaerneni is required. SL RPLEMIIN-RAL CONSTF L C71IO LION LAIN I)1 FORMATION DESICIN HR/IIIN GINEER: _ h a I AIrl pliaak k M ORTGIAG11 CCIM PAN Y: N of Alpp linable Name: IN am e: 11(idiif s s: Alddne:i a: City: Stal e: i Ci1 y: ta1 e: Zip: Pha ne. _ 2141: H I one: FEE SIMPLII TITLE I-OLOGR: Noi �Igpliu k le BCIh 10INU COMPANY: _Not Alpplicable N a me: Na ni e: AIdtlliess: Aciclreas: Cif y: a i 11I: Zip: Phan c Zip: aWNER/COZY TRACIOR AIIIIH10V IT: Alin Iiaa tion is r ereb)I ma do i o at to in a perm it to do tl a v is rF a nd ins taIla l ion a:i indicated, I aertilytl at no workar installation I asconirneri prior to the issuerica of permit, St. I uaie County makes no repreienU tion that is granting a permit will autl a riaa tr a permit holclar to briild the sul jest struatt rEi wl icl is in conflict wiitr aril a p p IN able Home Om ners Assn oration rules, k yla ws or a r d move n ants that may rastrist a r prohil it suah structure. II Ica se aonsuIt wnth+1a ur Homa Owners Assc aiation arid review your cleed loran)I restrictions Whrct ni a AiI, In aomidaration cftr a grariting of 1tis regriesteel permit, I do t erebi aurae that[will, in all respects, perform the work in acaordanae witl V a al1pra%iecl plc ns,tr a Ilorida Building Qades and St. Luaie(IountyAmenclments. TI a Ia11 Ina briildind perni it applica tions are c xfi ni from undergo ing a full cancr rrenay reviawi:rocs m ad6lions, aacE ss y s uiituras, swimming p c ois,fences,wialls,sidns,screen rnoms mod aacE ssory uses to anotl ar non-reslderitial visa "WAIIiINI G OWNER: YOUR IIIAIILU RH TCI RECCIRDI A NUTIC COW MEA CRMENT W Alf RESULT IN YOUR RANING TWIC CI 1MI9IRCIVEMEIM TCI ll OU R RRCIR9RTY. OF CON N ENCEN EA T MU ST BE R■CUIR11111] AIKID 1IIIIC1511TED 11H 8 JCIH SITE BE■ORE THE FIRST INS N. YOU IN7EAI DI TC I CISTAIIN FINAN CIA C I, CON SULT YClU NDER OR AN ATTCIRNEY BEFCIRIII IIECCI Y TICE OF CON MERCHMEAIIlI." Signatrira of Owner/Iei see,IUontrastar as Ag(i nt for Owner Sid at re oll Car tractor/tieense Haller SWITE C11 FLORIDA STATE CIH FLORIDA COU N Ty aN COUNTY CIH Ttefor inginArrim ntwiasaaknawlaclge<Ikellorerne Tla r aingin:itnirnc wiasaakriawlaclgeclkeilorerne 1 his cla±1 of 2a �"��k y thi�cWi I of 2i1 Zr, k y Nameofpersan mWiriastaterrent. Name of mal'inpl statamarit. fErsciriall�lKnawri �ORFrcduiie iaatian IErsenall11Krawn OR FroducedWEntilliaaticri -1i oil i ritilliaatiori 'li oil Identification F ra cluii ad p ra elude d ( ®natur , uaaWNliMID Si11r r 8 ' _Au�� Qlta'q MY tI a Mfv M:ION$ GGV 11!d 9 '' O Comm is - _ Y CONM183ION A G ril 19.2 1) Comm issia Apj119,%W21 j REV IDA S FRONT ZONING SUR RF VIA OR F LAIN9 VRGIIIIATIGN IRA TLIRTI FI MAP Gl E COUNTII R REV IEVI RE olh& R RVIAW REVIEI& F RV IRW R RVIRW DATII RECEIVED DA7R CCIMPI RTED a 11. 2/7/19 Rage 1 of 1 Micl a Ile Franklin, CIFAI--Saint Luaie County Property Ag1praiser-- All rigli t9 reserve( . Plioperty Identiflcai ion Site A ddri s.:311 C INE,"Ti GER RD ➢arti el ID:14(1-111-000t-Wi,-:I Sac)TowWRa+p:45f3]S/44E Aecount 1I: 1%63 Map ID:24A 13 Usii Type:4100 Zoning:A S- Count h+risdic inn:Saint Lw ii County CIN ne11shij x - lY t K Clain is A Cunningham  _ Pfl Boll 51 llort Pti rce,F1 34154 e ga 1 10lescuipt Ion 11RADE MINDS S/D LOT 6(OAS A(l)(OR 113-IM) Qurrent Value s histJMarkot Value 131,900 Asst ssed V a lue: 111,112 H xamp iai r S: 111,112 Taxable Valu is 10 r- 11ol a1 Areas FP11operty tar es ai le suhje ct 1 o cha nge upon einisl editlru er Air{9 F): I,cv 4 hange oiI owna rshIp. Gra ss 9 Will 41 d A3kra(9 F): 1,401 tavei ire n o i relic bit projei ti4 n of futtl tames. I and 9 ize(a+re,): O.M sal+ c f s pro perm wil I rou it t t1 a aem(us 1 of all I and ize{9 I): 8 27+I:I v en ptW4 assessment as M and spl eial clan•incations i Taxej for t}lis iarcel: !LC Tax Colin oils Ofhce Down loa d TRIN for ti-lis paraal:Ddwnlcad PD1 All inlartnatia n is b4 lioued to be aorrei t ut this time,tut is sul jaet to a hange and is proiiide< withaut at}l viarranty. (IColl3lright:10101e'ntLttciuG+t11t) llrellert;lAppraisir.All]ri'ghtsres+rrncl. htiFs:y www.pask.olig/REClard/ 417,2020 Page 1 a l 8 Flosicla Home Improve ni ci ni Bit wand Tel: 954-792-4413 �Ii social es FMian i Dade: 305-545-4469 Licen s e No. CGCI 061890 GI8449118 1I11a x: 954-792-2170 3044 SW 42nd St. #1<eptiOA Wet : %AIwvi.It ap raducls.aa ni Fl. Lauderdale, FL 333'12 MP RR0)18114011 Mail: intla@It apnaducls.aarri A VI tl a1A11101 Rclpllacierrienll Roci ing Cclntraclt Claudia Cllunningt arr / 772-882-2561 Dale: 03A30/2020 'ICI7616a mscunham@gmail.aarn Rep: Zaat Hauling 3510 h el:Igl(iri Rd FLIRT PIERCIE RL 349 47 -This Con-1 nacl is rn a de and a nielied ini o this date oil 03J30)J2020 by a ri d betvie ei n FH IpI, L I CI, a ❑elawane Clc rlponai ion I n own as ("Cloni ra(i l or" oii "FF11m), a ad Ownen(s) narn e d above a 1 i t e pliopenty localecl at l he address lh ted aba►Ie known as ("Owner"). 1It a Clori laactos a gilees to perform t he wiorik descnibed below al the gnoperily listed above: Harnie Clwnfuis fils9avialialn Homeowners Assoaialia ti a ppiiovai sequined? YES H0.4111arna No hoa II Phone Number 0 Glclntracltcir a Melee tcl petifertr deiscilihed Below: Ren m ie: Shingles (Square:) 15 Tile Roc f (Squa ties) N,JA Flal Roof (Squatles) 5.52 Guliena (Lineaii Feet) a Fai s a is Boa nd (I ini ai a ri Feel) 201 C Ins-la II: Shingles (Squares) '15 Tile Roof (Squares) Flail Roof (Squa nes) 5.92 C l fillers (Linear Feei) 0 Fa s cia Boa nd (I irl e a ri Feel) 20C 1 Shingle lilype Architectural Shingle C olon Clot bles'lolne CirlaN %eni T11pe Ric gel Vent L nde nlaymeni Diamcind Deick Wi11 1301t Fell Remove,IRe•lnsl all Sola ri Pool Panels RemovejlRe-install Solar Ho'l Waleii Per nets 0 0 Remove,IHaul Plway Bathe I Tile Rooll N.IA 1111Ial Cleck lnsulaiia rii (Squares) 0 Screen Remova I/11I ins ialI (LineaiiI goet) Sollfh Remove,Re plat cc (Lineail Feel) 0 a 2 N 2 Clouble Clone Poly S1}lligl I its) 0 2 ) 2 Flai Glass I aw E Skylight(s) a 2 N Al Double Cia nre Poill S1 jiIi1jh1(.,) 0 2 ) � filar Glass Laud E Skyligt t(s] a 4 N 4 Double C11ome Poly Skylighl(1) 0 4 N 4 Hla t Cllass 118 SI jlllgt i(s) a Pro je at Clonfitlmai ion Cllaudia Clunningham,11075'167 (Cris l a me is Initials) Nge 1 at S F cielfing Wanksheal rRernc ue existing rod i coveting (NOTE: Removed Harris are lit'ely to t e cla rn a Bled and cannon k a neused) ., Replaae roiiad c r damaged moll decking as applicable io it is project Reps in ou iiie Il laa a exist ing fa a a is board as applicable to t his pra jei t 1 Re-nail existing noo•I dei al to meet cunrienil Florida Building CIO des � Install new l51b.1eh unde nlaymenl as applicable to i I is project (to ri ain wanra t t ies may n of apply) Iasi all new 30 lb.,le it undeMayment a s applicable to ibis pnoject V Insi all Cie ni ainTeed Diamond Cleck supen higl p errla nmance undenlaym(nt as apf liea ble to ibis pra je a t V Apply rood cemen-1 and mernbnane al all hoof peneiriailons (certain wanna reties may ncl apply) Install Cle ntainTeed WiniarCluand high perlonrna r as undenlaymeni at all noon peneinalia ns Insi all Three lab staiiten shingles as applicable I this pnoject (certain warranties may nol apply) ImiIall CleriainTeed Swillil Stain high penfd nmance sianien shingles as applicable io this pnojecl install stancland drip edge around perimeter of nacf as appliaabbi to II is pioleat (certain warianlie:i rray tiorl apply) laslall heav)l gla cage I igh penfoumance drip edge anc tin d penimele n oil rc(A as a l plica ble to 11 is project Install standaiid valley melat in valleys as applicable to this pnoject (centair rniarrianil ies may nol apll ly) Ins tat ll ClenlainTe a d Wini euGluard high penfonmance un de rilayni eni in valleya as applicable to This pnoject ./ Ins to ll n ev i rood vent ilal ion to i ieplace exis ling (a a nil ain wanrai n lies may roof apply) Install Caei itainTee d l igll perifa nmance aidgle dent as a p plia a I le to i his prc ja at Ina to tl aertainTeed sl a n c la rid It nee lab si are er at in glen (cerrl a in warrianl les may not apply) lnsia Il r ami ClleiriiainTeed Landmark Pio shingles: Colon: Cable less a r e Gray Insl all s-ll a ri c I a rid 1F1 ipARidge accessonies as applicable i o this 11 nojecl (cci rill ain waura ni les may not apply) Insiall new Cie rill ainTeed H ip/Ridge accessonies as applicable t o 11 is p riojecl C Ile a r t p a n d haul all%A ay all mat eria Is and debris ilroni noon work Wanranit Weil in a a inglle coveracla horn rriiir ula41unen N a ri-pnoiia l a d a orient ge 50 yeaiis,Isom manuilactunen Maieria is and laban 50 yeaus-Iriom manwlaclwier Tea ri-of l so years horn manulaci ura n plisposal 50 ylears from manufaaiuner Woilrraratip 95yaansluommantilacluree `� Rige3af8 FHIPI Retail I nice $14,4 50 W I ales a le Chib Discount $146 Wal C antract price jincluding all discourits) $241404 at posiT 0.00 Balance Duo $124,� 04 Balance Fonn of Paymeni Clash Finance Mal emlelnt IN ati(( 1 a t1 a c winer, el fir ancing is k e it g a k lair ad by Ov in a r: a) Da net s ign this Contitacl or any-financing doci time n t in bla r N. You are en-1111e d i a z copy of It e aonl m at ai 1I a time ya ti s ign b) The -linancia I doe t me n Is prc vided I y a lends r1 l o l l is home ini pilova me nt con tract may cneai e a lie n on yatlr poopert}I. c) Be sune yoi understand a 11 q ror 1i<,ions of 1 he Ca ri tract and 11inanch I da a t rri(W s be-lore )lou sign. N isc ellanealu i This Cloni naafi and it e a a cc rn g a n)lin ll wtonks I es i coni ain-I he a n i h le agre a ru eni bel wieen'I I e panties. By s ign ing this Cloniract, Owneii agrees and ackncvuledges it at ii has iieceived lha accornptrillintl wuonksheei.This Clio nicaat rn a y not be 41 i nged orally but only by a Clhange Oiider on o'l l a r1 wniii e n a m endment signed Ill I of h panties. The waiver by any pal sty oll a brt a aI of any provisions olA his Conlre c t:i I a ll n of opera Te or be cons)rued as a wra fiver of a r y wriiien amendrnenT oii waiver) o-1 a rill subsequent biieach by any pansy. liou The buyer may cancel 1I is ConT ra c i ai any linit psiontonildnighlanTheihiiulbusinessclaya-heirlhe dale Vitt is Clon-lrlaci. In witness whereof, the paiities I e rlello l a ve i1a ad, undens•la nd and a tIcee to I oih sides oil it is Contract. Se me a explicado el cons nai o en su 1 ota liclai d y eni iendo i a cla s la s condiciones de esI e c ontnail c. Boi h p a nt ies exec ui e 1I is Conl ra a l and i ha io wner(s) agree io pay the balance du( undo n this Cla nt is 4 t under seal as oil 1 t o clay and yean fins) above wiT ten: 7^T tl iauslta a urn in gl a m/1175197 0.1/:ICl/202O [ ate 21aar Harth cl ceritractor Rapneaeniaiiiif t abi r, f� SHDCIAMTIIY F NGIN EHPIr G CONSUIITAIrATS, lira. r E AIDE - HIOWAIHI] - PAIIJM BEAT H May 1,207 fl _..,.... X n.Tom Bunnatt 111orida Horne Impr(ve rr ent 1044 SWI42n" Sucet Fort Haudeadale,F111I 33112 Re: 1510 MHT21GHR RUI,FOFIT PIHRCHI,FL:14941-9844 [107311671 STIHLII(1TIIIIIHAIL HHVIE" OF FAHIAINUIFIB NAIIL. N(I HHQUIHMEINTI Da an Mr. Burnett: Pursuant to Ilauu iiequest raie I ava neviawEid tl a anhancad nailing naquinad 1lou the flat naaf mambrarie installatian at the nelironaed I oma. Ot r frnding i sue as fie flows. Wind Design Cluitairia: 14=1 70 mph (1 sacand gust),Exposunn (1,Risk CategEin'l 2. Fllom tt e IIIIa iida Building Cade, RIA II 121: P,Idl:`17.8 ps1',Pl,d2:11.7 Hsi,P",d1:1108.1 pall Using NO A 20-1 ,1.01 Cldruinllii ad Clorporation that maatimunn flres,au:ue ui:ing El is 40 pail. 71he lam sl set is installed P sin c#intin along tha 4" widai siE1a lap and than 3 additional naw.,i ;iitaggared, 8" or riienured. IN tribunary anmiallan:lastsneri isi 8:111=811 squana inotes. The field nailitq (zcre 1)is aaceptabla ,iiirce 4: 8<60. 11 oxt ahacl none 2: f10171.7 '' V a/c=11.67"spacing. Use a :ipaoinq o.16"on E•ente!i for m ne r ext ahacl aoue 3: f10/1 C 8 " 8"a/a =,1.44"slI awing. Use a ,apaaing c f 4"on vents ii fk n zone 1. Thane are (2) flat rao.l away, (All) 19'x W,(A 11) 3:111 15'. Tho encl zEane distance is 101ALl CIIAII ]VUL2, ar 40% Maan roof teight, w1 M ever is smallen, but not lass• tl an 1 Iluct — ,IX of 6.1' or 6A' tl us 4I.5'goueuns. Tlha (All) Neill Iave a 5' uncle by '11' long zone 1 at tte 4iornena. Zona I will bpi tIe nemaiuirig 5' wide raolpeninieten. Zone 1 will t e tl a nernaining aente.i anaa olthe raaf. The (Al2) viiill I ava a 5' viide b,l 9' lorig rani 1 at the a•a vens. Zone 2 will be d a nernaiiiing 5' wicla raoll peninietar. Zone I will t e tl a ni maining centaii are a of tl a roof. We holly tl at you find tt is in,lonmati(n I e1phil and at ould}Iou I a, a any questions pleas@ flael fhiae to call on us. } SS;y�ti4[rr.'! ltl�rr Maspcutlhilly submitted 9pecialt`l Enginaering (lansultairts, Ikn¢. — �`j� f,Ia `.•`���^;�" (1/ c� a A 2 �' •y -j r y D. Adam L.af3lanc,I E 'as C3 ...oa' .•' �0 S` Matthow Barnas uraePaaStElentafEe8rgln J rig.%tS')'t ``����`` Project Ergiueen '4� r}�t ' I$1rhttrittt°� State o1 Fla rida: Aagistenad Pnoiles:iional Enginear: 11fl011012 (leutificate a fi Alud onization: 11(OU 17 1399�W I0`h Ahienui,Suites 20 - Boynton Bcacl , FL 31,116 - Clflfllce: Id1-711-3440 - Fax: 'V 1-7_11-5541 SHEIC IAIL7Y Hr G114IIEHINO CIONSUI1TAN TS, Imi. r - DAIDE - 111NIOWARE - PAIDM HEAIOH Hk it Rocif 21onas. 2 ------------- { (A2) 1 t LO ------------------ i 3 t i 15'-0' 12 � 'WOct2 fitrr((�((Uttitt 1599 SW 30 Alvanuai,Suila 24 - Boilli Lon Baach,FL:1:426 - ❑ffica: 61-11112-5440 - Fam: 561-152-51W2 CILIONT II\ FIIIOFIIIMA•1110N PROJE1017 11 FORMATION SPECIALTY ENOINNEAINII Cal 91ILTAPIT1, Im FLORIDA HOME IMPRIVEMINT TYPICAL ILAT HOOF 1599 >tw 31tn avl. ILIIN 29 3044 9W 47nd CTH BET IASI SIIOEf UNI EIRLRIM€INI LA19 1110IN N NEACII, FL 334126 Fa B T LAUD01F DAL 1, Fl 3J311 AP II) NA II/TINC)I H PLA4 OMEP IT FADE C092aR0 - ALz�r eFnan (NW 9a—Q 111.01) FL CA. ;��as2n :1161 - 3!2 - 54441 lMdE !61 - 11III2 - 5P'12 MkIl f OOF UNOIRLAWONY PER PIaA. 6" E NDLAA 0 0 LJ 0 cc cn 8 o . . b o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ac a I 0 0 a o 0 0 a all E O CJ O O O O a al �i € i Q O 0 c O a O O O O c O a 8" MAX. OUT THOEI MIDDLE ROWS JWIERID Al 8" KIN $ MAY HE LE9S OASIC a WIRIt IOAI . �lf,�yl4,rsaruEa�i��>. 6" JONI 2 4" JONI 3 No. 7;I 71 a K �i+ l � !lfflfll E[lllffttl' Y :rt - SHEUJAHTY HNGIIIN ERR A`G CONSUETAINTS, Ilne. HAIDE - EIROWAIRD - HAILM BEACH May 1, 2EO Mr.Tom Buni c tt Floliida Ha rriv Impnovameut 30,1,4 SW 42"d.II treat Foi t Lauidai rc l z h ,FL 311112 He: 3510 MH77JC HIR RHI,FO1dll'llll PIERC E,FIJ 349,17-984,1 [1079]671 ,ITHUCITURAILHHVIHW CIF ONHMNC171U NAMING Ill~IQUINNIH,14T Deat Mu. Burnett: Putivarit to 11ouu regtest vie I ava ueviawad the atiharicad nailing naquined .lo1i tl c flat reormarrbta ne installation at tle �iekre nucd I ome. Clue findings aue a:r fla Ilovts. Wind Llesiga Criteria: 11=170 1npi (:I ;itac rd Mt st),E3lposunt ❑,Rlisk Categair'l 2. From tl a lllorida Building Clocle,1U S 121: P,+dl:4:1 J 1I P,3d2:71.7 psi1,P,,dl:108.4 psl Using NOA 'O-131_(H CertainTecd Corparation tle maalimum prersure usinll E1 iti -(10 psill. The bast sleet is installed l"ort cantuir a ionit the�l" viide side lap aacl than 3 additiciral rums staglettecl, 8" an cantered. The tributary anaa pee fasteucti A &111=K sqt ane incl es. The field nailing(zone 1) is acaelltabla tinca 4!A<60. N cxt check none 2: f10/71.7 v a/a =(1.67"sill Uiie a sparing al C'an a•eateu roll zone 7. Next shack node 1, (10/103 * V o/a =4.44"sllaniing. Use a :iip airig a 114"an tenter fall zone 3. Tharei are (2) flat roofartas, (A1) 19'x W, (A3) J5'x I'll', The elicl zone distance is Ifl%L1 CIA 10%1-2, e n 41fl% Mean noail I eigl t, wl icl ever is irm llcr, bt t not lass than 3 hiet— 4.`II' or 6.3' oai 6.0' thus 4.9'governs. Tht (All) will have a 5' wide by 11' iou f Note ? at tl a -ranneur. Zane 1 will bt ti a rema inililt !' wide raol peuimcuir. Zone I will I e tl a ueni2ining aiantair araia oil tl a rooll. The (AI2) will 1 avo a 5' wide by J11' long zone 3 at tl c rc rriets. Zane 3 will ba tl a uentaininl 51' wido rao l perintettr. Zone I will I e tl a uetuaining tenter auea oil tl a Hoof. Vide f opai th,it you find tl is in larmatian l alp:lul and sNtiId 1lou have aa`1 qua;rtians please feel 16ri c to call on its. Rlespectfullll submitted +`+t ky5Sli 1l3F1Ilil1,�/ 1pecialtyEnginaetiinlClarsultavts, Itc. +''` s� i : 1 `' Z♦..1 _ `. •.l o. 770'- _ I� 0 I i 020 S-IME CIF ' 11. Aldano LeBlatic,PE %., Matthew Barnes P. ' �. . 'Ui,re Puesida nt off Ilesigll C)Rt`� Project Engineer I Itt to o.I Flonida: .,,�"'j1 7711tititt�t�`,` RcBistened Pnofemianal Enginaelr. #0 7013 Cartilreata oil Aluthaniaatia n: (9211 1199 SW 34`h Atienue, Suite H - Ba}lntau Beaah,FL 1342t1 - 0:117ice: 51A-,152-'1440 - Fax: 'll(11-752-11'_I42 ,p4` SHE(IIAIIIIIY HNGDEHRIT�G CONSUBTAInTs, Ilnc UAIDE - HROWA RID - HAILM SEAI(IH Flat Rucif 2lonlas pe 8I r-Qp I I I I I I (A2) 7 I i I I -------------------- Nr c� Nn coi (Al) a � a I I l - ,``t.iiF;ti�utttlry��fr,I i No. 77 u t;`iTl OF AL ���riflFf EE111 SiSSi; 1999 SW130th Alvainua,Suit4 A - Boyvlon Be icl ,FL 31-1�6 - OflflRae: 961-7E-5144U - lair `.1161-TIC-9541 CLIENT INFIOAMA11ION FIROACIT IN FICIRMAIIIIION SAIC61LTY1NGINIEF1Ntl WISU11KNT1I, lac 1.M SW Mh AVE. KOWA HOMI IMPR4VEHON11 TY11DI. RLAT ROOII !IUR z1i 3d 44 SW d a n�I SIREET H ASN SE 19ET UI 1011RLA!IMEI 1 LAf11 z aOrrri rr 1EACH, FL 32426 NOR] LAUDARDA L8, FL ]-I311 )I P D 1 IA 1I/1111NCA F PLAO UMENT NdA 9C-01;111.01 OAOB - 11OYu1RC _ 1AIA1 NEIGH( ) FI. Cl, IIC�z1a 561 - 712 - 544+ (I FF14E Al - 712 - 5942 FAI I 1`1001 UNI FIRLAYAIFNI9 PNR 1 NOA. !I" ANDLAA 0 O LL Cl v' d � 8 � o O O a O O O O O 0 a O a O O O O O O r O O a O O O O I { ri of f O O O O O i O w O O p O O O 4 O O O O c O 4 I LL8" MAX. AUT TF RE] MOB LE ROWS S AlaORK Al d" MIN MAY BE LIFS IIASIIII: fl N WINO I OAA. * lit!'tt113 F1 Si1117;+ S'i AIONE 1 4" ION# 3 �Cl No 77012 " I:i!!lfi S411i1t'•'• L SPEC:IAILIT W GIN HEIiIINCI CIONSUH'IIANTS, Inc. DAIDE - BIiIUMIARU - PIAUM HHAtII11 May 1, 02(I Mr.To rn Bunnli tt Fla rida 11 on c Imgna dement 1044 S W 42"'I Stient Fart Laucleadale,FL 33313 RI: 3J10 METI21GIIIR II1ll,FOH11 HIEHCH,FL 34I947-5l144[:It 7511t171 S'ARUCTUHAIJ HENRE'"I OF I NHIAIIY UHD 1 A IlHI1V G REQUI41AHN1 Lea:i Mn. Bwmett: Itirstiant to your raquaat we hime.nvicAmid the enl aaaecl nailing negluiiied fon the flat noafl rnemtnanc installation at tl a nc femi ncad home. Our Ilnclings art cis callous. Wind Iluaign Clritenia: V=170 n ph. (1 second gust),Eaigosure Cl,Ri:iit Category 3. From ti a Fla rids Building Clods,V A9 128: Pd,dl:42.8 paf,P,,d2:7.1.1 pef,Pa d3: 118.0 llsl Using NOA 10-1 L01 ClcrtahiToed Conponatian tl c niaxiniam pnessure using El is-410 pal. De t ace sheet is installed 8"ou aFi aten along ti a 4"micle side lap and tteu 3 additional roves st.ifgonad, 11" oil centered. Tt a tnil utarll anea pair fla am r is 8x]1=88 squam inches. 7te 11kild nailing)(aone 1) is acceptable sitice.-l?.1f,00. Na Nt a•lec•k aone 2: 64/11.1 8"o/c = 6.(17"spacingl. Uae a sgaeirig oitl"cite center tell aonc 1. Next a-lec k;Lone 1 64/108 " 8"o/a =4A4"spaciiill. Use a spacing oUl"on canton flan aone 3. Ttenc are (I) f at too 0areas, (Al I) IC'x I#I', (Al2)II'm 11'. The and aona di:•[an cc is II%L1 CIR 1917.6U, on 4U°/n Mean uooll height, wI icheuen it rmaller, but not less tl-all 3 feet— 4.-'1' or(1.2' or(1.0' thus 4.5'1lovarns. 1111ha (PII) wi11 have a 11' wide t)I 5' lonj aona 3 at the comm ciis- Zorn; 2 will be the tic maininll 111' wide lion panimeten. Zone I will be the rc ma it inj center anea of the wolf. Th€i (p12) will have a 9' wida I y 5' lou11 xone 3 at tl a caimans. Zone 2 will be tl a remaining 11' widai root lanimeter. Zonc I will be the iiema inirill ce r tFii r a i iea o I the nool We I ap+i that)lou Ilnd this inforimatia ri hoIgft I and should 7la lute an,I qua stians plea aa deal Irea to ea 11 on us. R espeut.lulI]l sul mitts d Specialty Engitcc ling Cloiisultants, Ina. ( P i 1, r _ ty Il. Aclan LeBlanc, PEilievi Barnes N icc President A Resign }qj£a ct Ell gN fe-!hE State ail Flouida: Registened 1l to ileasian al Ei111 ins er: #10017013 N Pi k Centifieate o:l/ uthonimitim: 11009311 1511q SW 30`a Avenue,Suite 24 - Boilmou Beach,FL ' 3426 - CI Ifica: 561-11`12-5.1 10 - Fa)i: 561-1512-51l ld a SPIIGAL]Y E?I CIIINHEPING Clan SUIIIT AN 11S, Inc. E, DAL H - BACIWARD - PIIAUM. ]REACH Hal Rllaof Aantis U ! 2 ! 3 i ! ( i i i ! 1 OC i (A2) j f ! i � --_-F___..._ Le E I t i 031 ! i 2 3 i t fxUlA I . 5 55 4i54111FF3 P �q i o 7 i,I I •�r��fFtlllll115y4:.�,• 1999 SWJ 7a"'Avanua,Suite ]0 - Boynton Beech, FL 31426 - OfIce: 561-192-544 - Hair 961-792-5547 CLIENT INFIORN ATIICIN RROACT INFIORMAICIN FE ALT1 811CINIVIN9 a OPILIL11NT9, Inc 1 R ICI L LI Ra H 1991 S4 Mh AVE.IRD NOMI IMflIAOV8IMEN s n1Te I12( 11044 SW Qnd SIRIEI BATH 9FIRET IIPTEHUYMIPIT U RS 8411NU I REI,IF, F1 .13426 RIORI LAUR HRDA LA, IL :13:1112 END PIAII/'IIIIN(AP HLACEII INNT PIOA :0-01311.41 [7A1E — BRAVAIID -• RALM MICH FII CA. JI11139217 (i)141 - 792 - 5441 fFRE 541 - 792 - 5542 FA; ROa H U110 9RLA)IMEI IIS HER NOA. 8" AND L, fl 0 0 c� 0 LL d V 0 a 0 0 O O O O O O O O w 0 O O O O O 0 rn N O 0 d 0 4 tl 4 I �1 m tl O O O O O C 3 F O O 0 0 O O E 0 0 O C O O 8" MAX_ 8UI 1FIRII M1aDIEl ROW9 S RQOEHAD Al 8' MIDI FI" MAl1 BM L1119S 9A9HD ON WIND I OAU. ;iirurrrrrrfrr�� a' ZONIII 2 {•� CII �! I '' 1I' 210NIIII 3Oil >_ — ± CAI F r Florida Building Code 6th Edition (2017) High-Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master Permit No. Process No. Contractor's Name Job Address ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles Are there ❑ Prescriptive BUR-RAS 150 Gas Vent Stacks? Yes❑ No❑ ROOF TYPE Type: Natural❑ LPGX❑ ❑ New Roof ❑ Re-Roofing ❑ Recovering ❑ Repair ❑ Maintenance . ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. _ --t - - - �-- _ - ---------� =- -- - I - - _- -- -- N --1�J - _ ---- - L -- -y _dd if Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (if a component Is not used,Identify as'W) System ManufacturerField: oc @ Lap.#Rows_ �'oc NOA No.: Perimeter.—'oc Q Lap,#Rows_ oc Design Wind Pressures,From RAS 128 or Calculations: Comer: oc @ Lap,#Rows _'oc Number of Fasteners Per Insulation Pmax1: Pmax2: Pmax3: Board Max.Design Pressure,From the Specific NOA System: Field Perimeter Comer_ Dew Illustrate Components Noted and Type: Details as Applicable: Gauge(rhickness: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Slope: Strip, Base Flashing, Counter- Flashing, Coping, Etc. Anchor/Base Sheet&No.of Ply(s): : Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Anchor/Base Sheet Fastener/Bonding Material: Material Thickness, Fastener Ty pe, Fastener Spacing or Submit Manufacturers Details that Insulation Base Layer Comply with RAS 111 and Chapter 16. Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer. FT. Top Insulation Size and Thickness: Parapet Top Insulation Fastener/Bonding Material: Height Base Sheets)&No.of Ply(s): FT. Base Sheet Fastener/Bonding Material: Mean Ply Sheet(s)&No.of Ply(s): Roof Height Ply Sheet Festener/Bonding Material: Top P r. Top Ply Fastener/Bonding Material: Surfacing: 123 01-48 12/09 PAGE 3 Florida Building Code 6th Edition (2017) High-Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: P2: P3: Maximum Design Pressure From the NOA Specific System):— Method of the attachment: Steep Sloped Roof System Description Deck Type: ype Underlayment: Roof Slope: nsulation: : 12 Fire Barrier: Ridge Ventilation? astener Type&Spacing: dhesive Type ype Cap Sheet: oof Covering: Mean Roof Height: Type&Size Drip Edge: 3/20/2019 CERTAINTEED CORP,TFWZ.R684-UL Product Spec See General Information for Prepared Roof-covering Materials http://productspec.ul.com/document.php?id=TFWZ.R684 1/3 3/20/2019 CERTAINTEED CORP,TFWZ.R684-UL Product Spec http://productspec.ul.com/document.php?id=TFWZ.R684 2/3 3/20/2019 CERTAINTEED CORP,TFWZ.R684-UL Product Spec http://productspec.ul.com/document.php?id=TFWZ.R684 3/3 M IAM I•DiADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Landmark,Landmark Pro,Landmark Pro/Archetect 80,Landmark Premium,Landmark Impact Resistant,Landmark Solaris,Landmark Pro Solaris and Landmark Solaris Gold/Platinum LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 17-1211.08 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino �•- NOA No.: 18-1114.02 MIAMMALDE COUNTY Expiration Date: 02/28/22 �MINWMAPJ Approval Date: 05/09/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials Dimensional Deck Type: Wood SCOPE This acceptance is for CertainTeed Landmark, Landmark Pro, Landmark Pro/Architect 80, Landmark Premium, Landmark Impact Resistant, Landmark Solaris, Landmark Pro Solaris and Landmark Solaris Gold/Platinum Shingles as manufactured by CertainTeed Corporation described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION: Test Product Dimensions Specifications Product Descri tion Certainteed Landmark Manufacturing Locations#1, 2, 3,4, 5, 6, 7, 8, 9, 13%4" x 38 3/4" TAS 110 A heavy weight, dimensional 10 asphalt shingle. Certainteed Landmark Pro A heavy weight, dimensional Manufacturing Locations#1, 3,4, 5, 6, 9, 10 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Premium A heavy weight, dimensional Manufacturing Locations#1, 3,4, 5, 6, 8, 9 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Impact Resistant A heavy weight, dimensional Manufacturing Locations#7 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Pro/Architect 80 A heavy weight, dimensional Manufacturing Locations#8 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Solaris A heavy weight, dimensional Manufacturing Locations#8, 9 131/4" x 38 3/4" TAS 110 asphalt shingle. CertainTeed Landmark Pro Solaris 131/4" x 38 3/4" TAS 110 A heavy weight, dimensional Manufacturing Location#9 asphalt shingle Certainteed Landmark Solaris Gold/Platinum A heavy weight, dimensional Manufacturing Locations#8 131/4" x 38 3/4" TAS 110 asphalt shingle. Accessory Shingles Accessory shingles for hip,ridge various proprietary and starter strip applications. MANUFACTURING LOCATIONS: 1. Peachtree City, GA 2. Ennis, TX 3. Oxford,NC 4. Shakopee,MN NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 2 of 7 5. Avery(Milan), OH 6. Norwood, MA 7. Shreveport,LA 8. Portland, OR 9. Wilmington, CA 10. Jonesburg,MO EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies, Inc. PCTC-01-02-01 TAS 100 01/12/01 CTC-006-02-01 TAS 100 11/12/02 CTC-092-02-01 TAS 100 02/23/12 CTC-091-02-01 TAS 100 02/21/12 CTC-090-02-01 TAS 100 09/02/11 CTC-087-02-01 TAS 100 07/07/11 CTC-086-02-01 TAS 100 07/07/11 CTC-101-02-01 TAS 100 10/05/11 CTC-102-02-01 TAS 100 10/05/11 CTC-109-02-01 TAS 100 01/18/12 CTC-106-02-01 TAS 100 11/02/11 CTC-105-02-01 TAS 100 10/31/11 CTC-089-02-01 TAS 100 07/18/11 CTC-088-02-01 TAS 100 07/18/11 CTC-213-02-01 TAS 100 05/20/14 CTC-212-02-01 TAS 100 05/21/14 CTC-207-02-01 TAS 100 05/20/14 CTC-206-02-01 TAS 100 05/20/14 CTC-110-02-01 TAS 100 02/13/12 CTC-109-02-01 TAS 100 02/13/12 CTC-288-02-01 TAS 100 09/27/16 CTC-333-02-01 TAS 100 11/08/17 Underwriters Laboratories,Inc. 94NK9632 Wind uplift resistance TAS 107 11/30/00 R684 UL 790 04/02/01 02NK42448 Wind uplift resistance TAS 107 11/08/02 09CA28873 Letter 07/23/09 11CA59020 TAS 107/ASTM D3161 01/25/12 1INK07864 TAS 107/ASTM D3161 09/29/11 07CA26696 TAS 107/ASTM D3161 09/21/07 I ICA38844 TAS 107/ASTM D3161 01/28/12 I ICA38844 TAS 107/ASTM D3161 01/27/12 06CA28237 TAS 107/ASTM D3161 09/22/06 IONK17366 TAS 107/ASTM D3161 01/04/11 4786334383 TAS 107/ASTM D3161 05/28/14 4786307351 TAS 107/ASTM D3161/ASTM D 3462 05/13/14 NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 3 of 7 11NK08333 ASTM D3462 05/15/12 11NK08333 ASTM D3462 04/15/12 11NK07864 ASTM D3462 09/29/11 11NK08333/Letter ASTM D3462/UL790 11/05/12 11NK08333/Letter ASTM D3462/UL790 11/05/12 11NK08333/Letter ASTM D3462/UL790 11/05/12 12NK13474 ASTM D3462/UL790 05/27/13 4786325932 ASTM D3462/UL790 04/04/14 4787011023 ASTM D 3462 08/01/15 11CA38844 TAS 107/ASTM D3161 01/26/12 06CA02648 TAS 107/ASTM D3161 02/23/06 4787084802 TAS 107/ASTM D3161 03/14/16 4787852839 ASTM D3462 03/24/17 4787011023 ASTM D3462 08/01/15 4788368979 ASTM D3462 10/30/18 4787592174 ASTM D3462 10/21/16 LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION: 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail'B', attached. NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 4 of 7 LABELING: 1. Shingles shall be labeled with the Miami-Dade Product Control approved seal as seen below or the wording "Miami-Dade County Product Control Approved". MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS: 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 5 of 7 SHINGLE LAYOUT Rake Edge 8--I S� 16 3/4 6 11 5� 11 27 3/4 6~� 6 32 3/4 5 518 FUII Starter Shingle Eaves LANDMARK, LANDMARK PRO,LANDMARK PRO/ARCHITECT 80,LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT,LANDMARK SOLARIS,LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 6 of 7 DETAIL++B im, 383140 �I Release Ta$+e Nailing area far"IDw&standard slopes(from 2:12 to 21:12) Nail between uppers lGwernall lines. 12" 14 3J4" 12" ,F 'Pi 13 114" VVIDE 1, 1 NAILING — AREA E r �7 V2- Exposure ll LANDMARK,LANDMARK PRO,LANDMARK PRO/ARCHETECT 80,LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT,LANDMARK SOLARIS,LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM (LOW AND STANDARD SLOPE Release Tape Nailing area for"steep"slopes(greater than 21:12) Nail between bottom 2 nail lines. 12" 14 3/4" 12" 13 1/4" 1 1 5 5/8" 6 1/8" Exposure LANDMARK,LANDMARK PRO,LANDMARK PRO/ARCHETECT 80, LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT,LANDMARK SOLARIS,LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM (STEEP SLOPE END OF THIS ACCEPTANCE NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 7 of 7 1'4lAWl �„ ..� MIAMI-DARE COUNTY rmi lIIL PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 r T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economv CertainTeed Corporation 1400 Union Meeting Road Blue Bell,PA 19422 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. F 1 DESCRIPTION:CertainTeed Shangle Ridge,Shadow Ridge,Hatteras Accessory,Presidential Accessory,and E Cedar Crest Hip and Ridge Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 12-0611.02 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0824.05 NMI•T7 MIAAD;COUNTY Expiration Date: 11/15/221/15/22 Approval Date: 11/16/17 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category' ! Roofing Sub-Category: Asphalt Shingles Materials # Laminated Deck Type: f Wood I SCOPE This approves CertainTeed Shangle Ridge, Shadow Ridge,Hatteras Accessory, Presidential Accessory and Cedar Crest Hip and Ridge Shingles as manufactured by CertainTeed Corporation(PA)and described in Section 2 of this Notice of Acceptance. E PRODUCT DESCRIPTION Product Dimensions Test Product Description i Specifications Shangle Ridge 12"x 18" TAS 110 A pre-assembled, double layer hip and Manufacturing Location(s) #1 ridge fiberglass reinforced asphalt shingle with an 8"exposure. Shadow Ridge 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #1,2,3,4 reinforced asphalt shingle with an 5" exposure. Hatteras Accessory 12"x 18" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #1 reinforced asphalt shingle with an 8" exposure. Presidential Accessory 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #2 reinforced asphalt shingle with an 5" exposure. Cedar Crest 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #1 reinforced asphalt shingle with an 8" k exposure. PRODUCTS MANUFACTURED BY OTHERS Product Product Description Size Manufacturer Any approved sealant with a current Miami Sealant various Any approved manufacturer Dade NOA (with a current Miami Dade NOA) Any approved adhesive with a current ASTM C920,Type S, various Any approved manufacturer Miami Dade NOA Grade NS,min Class 25 (with a current Miami Dade NOA) i 1 F r i NOA No.: 17-0824.05 M"10MADE co�awrr Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 2 of 9 3 MANUFACTURING LOCATION 1. Oxford,NC. 2. Shakopee,MN. 3. Avery, OH 4. Norwood,MA. j EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies,Inc. CTC-028-02-01 ASTM D 6381 08/06/07 CTC-021-02-01 TAS 100(A) 05/16/06 CTC-029-02-01 TAS 100(A) 08/06/07 CTC-030-02-01 TAS 100(A) 08/06/07 CTC-020-02-01 TAS 100(A) 05/16/06 CTC-072-02-01 TAS 100(A) 02/10/11 CTC-334-02-01 TAS 107 08/29/17 CTC-330-02-01 TAS 107 08/27/17 CTC-310-02-01 TAS 100(A) 05/31/17 CTC-311-02-01 TAS 100(A) 05/31/17 CTC-312-02-01 TAS 100(A) 05/31/17 j CTC-315-02-01 TAS 100(A) 06/19/17 j CTC-314-02-01 TAS 100(A) 06/19/17 Underwriters Laboratories,Inc. 07CA30825 ASTM D 3161 08/06/07 R684 ASTM D 3462 08/04/04 I R684 ASTM D 3462 08/05/04 IOCA44960 ASTM D 3462 11/11/10 j IOCA44960 ASTM D 3161 11/11/10 4787855169 ASTM D 3161/3462 07/27/17 4787855164 ASTM D 3161/3462 06/27/17 4787867612 ASTM D 3161/3462 07/26/17 4787855162 ASTM D 3161/3462 06/26/17 4787855167 ASTM D 3161/3462 06/30/17 1 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Layout Details herein NOA No.: 17-0824.05 MIAMI•DADE COUNTY . , Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 3 of 9 i i l j e LABELING j 1. Ridge Cap Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade County Product Control Approved". CMIAMI-MADECRONTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 Thi`s Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. E LAYOUT DETAILS SHANGLE RIDGE RemDw tape tr0fn th6 ti9N Sid6 d and tstan E SECOND FaSten#h�� I Side 8 All RIGHT Fi R LEFT I 1 Nu�re NOA No.: 17-0824.05 cour�rr Expiration Date: 11/15/22 1 Approval Date: 11/16/17 Page 4 of 9 i i k SHADOW RIDGE i l MI { I � i HATTERAS ACCESSORY 1 } i I G i 4 I 4( f I i i NOA No.: 17-0824.05 MMI-DADE COUN W Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 5 of 9 I PRESIDENTIAL ACCESSORY i 1 i i I i CEDAR CREST Sealed! Sealant 4-Starter Plem i I CMI-MADEUNTYNOA No.: 17-0824.05 •••. Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 6 of 9 f s i i f a NAILING DETAILS i i SHANGLE RIDGE 12° 1/4"wide bead of adheslve,7" long, �" (ao5 mm 'l 3/4"-1" from side edge of cap shingle I - (25 mm (26 mm) 18" B M (457 mm) (219 Inm) { Failing pattern all applications -two mils per shingle. SHADOW RIDGE 1/4 wrfde bead of adhegive,3n-3112®long, � (306 mm) -"1 3/4"4"from side adge of cap;rhingle J: 1" (25 mm) ... (2S mm) 12' N yk .��11171� '�{�7 ITtm (1 4 f Nailing pattern all applications -two nails per shingle. I ' I { NOA No.: 17-0824.05 ' MIAMMADE CCUFITY Expiration Date: 11/15/22 i Approval Date: 11/16/17 Page 7 of 9 I s i i HATTERAS ACCESSORY 12" IM" wide knead of adhesive, Y tong, 305 mm)�`� 3/44'-1"'from side edge of cap shingle 1" 1" (26 rr •*• ••■ ( 6 mnn ,.... ... .. 18" 9 t " (457 mm) (286 mrn) f Nailing pattern all applications-two mails per shingle, PRESIDENTIAL ACCESSORY 1/4"wide bead ai adhesive, 3"-3112" long, 12y 3/4"A from sine edge of Gap shingle (305 mtn)r" i 1" 1" (25 mm} (2a mm) 1211 a we �305 mrn) (143 1 mm) Nailing pattern all applicatlons-two rims per shingle. { MIAMI•D®UNrr NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 8 of 9 1 CEDAR CREST 1/4''wide bead of adhesive,4"long, 3/4"-1"from side edge of cap shingle .fir-z.,�;•;:.,Overlay�;,.,.:.., ...`0'. 1"(25 mm) 12" 8 5/8" (305 mm) (219 mm) 12" I (305 mm) Nailing pattern all applications -two nails per shingle. END OF THIS ACCEPTANCE NOA No.: 17-0824.05 MI 1-12[11 C4UN7Y Expiration Date: 11/15/22 •� r Approval Date: 11/16/17 Page 9 of 9 HIA,I MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy CertainTeed Corporation 20 Moores Road Malvern,PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Ridge Vent 12" Filtered and 9" Filtered LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 15-0831.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Materials: Plastic Maximum Design Pressure: N/A Fire Classification: N/A TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene low profile attic ridge vent 12" Filtered herein for installation in shingle roof systems. CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene low profile attic ridge vent 9" Filtered herein for installation in shingle roof systems MANUFACTURING LOCATION 1. Orrick,MO EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Architectural Testing,Inc. TAS 100A(95) 6457.01-109-18 08/08/06 TAS 100A(95) 65453.01-109-18 08/08/06 PRI Construction Materials Technologies ASTM G 155 AVIG-006-02-01 10/18/11 ASTM G 1929 AVIG-005-02-01 10/18/11 ASTM D 635 AVIG-005-02-01 10/18/11 ASTM D 2843 AVIG-005-02-01 10/18/11 NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 2 of 4 APPROVED APPLICATIONS: Tradename: CertainTeed Ridge Vent 12"Filtered,and CertainTeed Ridge Vent 9"Filtered System Type: Mechanical attachment of static vent over asphalt shingle roof systems only. Slot: Cut a minimum 1'/Z" slot along the apex of the roof by cutting 3/4" on each side of the ridge. The slot shall terminate approximately 6" from the rake edge. Installation: Place ridge vent section centered over the void at one end of the ridge. Plugged end should be flush with end wall of ventilated space under roof. Pre-fasten first section using roofing nails through pre-drilled nail bosses. Continue to pre-fasten remaining sections,making sure support walls are flat on roof and filter is secure between shingles and vent. Cut final section to length. Ridge Shingle: Nail cap shingles in place using roofing nails long enough to penetrate through the roof sheathing a minimum of 3/16 of an inch. Use nail lines provided on vent. Net Free Area: Refer to manufacturers published literature. Minimum Slope: 2:12 LIMITATIONS: 1. Refer to applicable Building Codes for required ventilation. 2. This acceptance is for installations over asphalt shingle roof systems only. 3. CertainTeed Ridge Vent 12"Filtered,and CertainTeed Ridge Vent 9"Filtered Ridge Vents shall not be installed on roof mean heights greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 3 of 4 DETAIL DRAWINGS 11.0 R4.9 r 400 � 18° l.Q 2.5 .18 O.S. b.= op 13.8 CERTAINTEED RIDGE VENT- 1211 FILTERED iL C .S. 3.5 5.2 113 CERTAINTEED RIDGE VENT- 9" FILTERED END OF THIS ACCEPTANCE NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 4 of 4 MIAMI•DIADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.2ov/eeonomv CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Underlayment Systems LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-0306.07 and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Semino Im �- NOA No.: 19-0506.02 MIAMI•DAD,COUNTY Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS SCOPE: This approves CertainTeed Underlayment Systems, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specification Description WinterGuard HT 36"x 65' ASTM D 1970 Modified fiberglass reinforced,bituminous sheet Manufacturing Location rolls material for use as an underlayment in sloped roof #1 assemblies. Designed as an ice&rain shield. WinterGuard Granular 36"x 65' ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Manufacturing Location rolls bituminous sheet material for use as an #2 underlayment in sloped roof assemblies. Designed as an ice&rain shield. WinterGuard Sand 36"x 32.5' ASTM D 1970 Embedded sand surfaced modified, fiberglass Manufacturing Location rolls reinforced,bituminous sheet material for use as an #2 underlayment in sloped roof assemblies. Designed as an ice&rain shield. Diamond Deck"" 48"x 250' ASTM D 226 Synthetic, scrim reinforced underlayment for use Manufacturing Location rolls Type 11 under shake, shingles, slate or metal roofing. #3, 4, & 6 MetaLaymenem 39 3/8 "x 61' ASTM D 1970 A film surfaced, self-adhering underlayment for Manufacturing Location rolls use under metal roofing. #1 Black Diamond"' 39 3/8"x 68' 7" ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Base Sheet rolls bituminous sheet material for use as an Manufacturing Location underlayment in sloped roof assemblies. #2 Designed as an ice&rain shield. Not for use as an Anchor Sheet.Direct adhesion to wood deck not permitted in the HVHZ. NOA No.: 19-0506.02 Miar�i•oaoe[ouNTv Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 2 of 9 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specification Description Flintlastic GTA 39 3/s" x 32' 10" ASTM D 6222 Granule surfaced APP Modified Bitumen Manufacturing Location rolls Grade G membrane with non-woven polyester mat #1 Type I reinforcement for torch application. All Weather/Empire 39 3/8"x 65' 10" ASTM D 4601 Asphalt coated fiberglass reinforced base sheet. Base Sheet rolls Type II Manufacturing Location #1 Flintlastic GMS 39 3/8"x 32'10" ASTM D 6164 Granule surfaced SBS Modified Bitumen Manufacturing Location rolls Grade G membrane with non-woven polyester mat #1 Type I reinforcement for mop application. Flintlastic SA Cap 39 3/8"x 33'11" TAS 103 Polyester reinforced, self-adhering SBS modified Manufacturing rolls bitumen cap sheet. Location#1 Roofers' Select 36"x 144' rolls ASTM D226 An asphalt-impregnated, organic felt reinforced Manufacturing Type I with glass fibers,roofing underlayment. Location#5 RoofRunner 48"x 250 rolls ASTM D226 Synthetic, scrim reinforced underlayment for use Manufacturing Type II under asphalt shingles. Location#6 MANUFACTURING LOCATION: 1. Little Rock,AR. 2. Shakopee,MN 3. Hangzhou, China 4. Silvassa,India 5. Shreveport,LA 6. Dadra,India NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 3 of 9 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date TrinitylERD 3530.12.05-1-R1 ASTM D1623 10/05/09 C32240.03.10 ASTM D4977 03/04/10 C30890.03.10-1 ASTM D1970 03/17/10 C3500.04.10 TAS 103 04/01/10 C31860.05.10 ASTM D1623 05/18/10 C40050.09.12-2 ASTM D1970 09/28/12 C45240.01.14-1 ASTM D1970, TAS 110 01/15/14 C32930.01.1 I-R2 ASTM D1623 01/20/14 C45240.01.14-2 TAS 103, TAS 110 01/24/14 SC6465.05.14 ASTM D 226 05/29/14 SC7470.10.14 TAS 114 B 10/21/14 CTR-SC11145.09-3A ASTM D4601 09/19/16 CTR-SC11415.11.16 TAS 103 11/28/16 CTR-SC11505.12.16 ASTM D1623 12/22/16 ACT-SC14110.06.17-1 ASTM D 226 06/29/17 ACT-SC14110.06.17-3 ASTM D 226 06/29/17 PRI Construction Materials CTC-071-02-01 ASTM D6222 08/08/11 Technologies, LLC CTC-093-02-01 ASTM D6164,ASTM D4798 08/09/11 CTC-163-02-01 ASTM D6757,ASTM D226, 05/09/13 ASTM D4869 InterTek Testing Services Ltd. 10103165000Q-002C ASTM D226 08/13/13 101227796COQ-003C ASTM D4798 08/13/13 10103165000Q-005C ASTM D4869 08/13/13 QAI Laboratories RJ3502-1 ASTM E108 09/29/14 Nemo/etc. 4S-CTR-18-003.09.18 ASTM D4798 9/21/18 4S-CTR-1 8-003.03.09.A ASTM D226/TAS 110 03/13/19 NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 4 of 9 APPROVED ASSEMBLIES: Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4"headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. (2:12 to<4:12) One or more plies of Diamond Deck with a minimum 25"head lap and a 12" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 72"minimum. Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes, &shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above)A single layer of RoofRunner shall be applied with printed side up,parallel to the eaves, overlapping each course with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and spaced 15"o.c. vertically and 12"o.c. horizontally in the field of the roll. Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with applicable Roofing Application Standards and Building Codes NOA No.: 19-0506.02 MIAMI•DAD,COUNTY Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 5 of 9 Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above)Two plies of Roofers' Select with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in a grid pattern spaced 12"o.c. in the field of the roll. (2:12 to<4:12)Two plies of Roofers' Select with a minimum 19"head lap and a 12"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in a grid pattern spaced 12"o.c. in the field of the roll. Vertical joints should be offset 72" minimum. Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with applicable Roofing Application Standards and Building Codes Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT, WinterGuard Granular,WinterGuard Sand,MetaLayment or Black Diamond Base Sheet self- adhering membrane adhered to the anchor sheet with a minimum 3"headlap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped,then anchor sheet must also be strapped. Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes, &shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 6 of 9 Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(5): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One ply of ASTM D 226 Type I1 organic felt or All Weather/Empire Base mechanically attached with a minimum 4" side lap and a minimum 6"end lap.Anchor sheet shall be applied at a right angle (900)to the slope of the deck with approved annular ring shank nails and tin caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll of the base sheet. Ply Sheet: (Optional) One or more plies of an ASTM D226 ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or Flintlastic GTA torch applied to the preceding sheet or Flintlastic SA Cap, self-adhering membranes adhered to the preceding sheet with a minimum 4" side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped,then anchor sheet and ply sheet must also be strapped. When used in Tile roof systems the cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum of 12"o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Surfacing: •Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof tile system mechanically fastened as specified in their current NOA. •Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof tile system adhered as specified in their current NOA using any foam adhesive listed and having a current tile adhesive NOA approval. Must comply with appropriate Roofing Application Standard RAS 118, RAS 119, RAS 120 and applicable Building Codes. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 7 of 9 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular, WinterGuard Sand, DiamondDeck, MetaLayment or Black Diamond Base Sheet as a cap membrane shall be acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. CertainTeed underlayment roofing systems utilizing RoofRunner or Roofers' Select shall be acceptable for use in asphaltic shingles. 3. CertainTeed underlayment roofing systems utilizing Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof tile systems as specified in the surfacing option of the approved assemblies. 4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with applicable Building Code. 5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities. 6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap, MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof for longer than 180 days of application. RoofRunner and Roofers' Select shall not be left exposed as a temporary roof for longer than 30 days after application. 8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or Miami-Dade County Product Control for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance, and fire testing results. 9. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 10. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 11. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. NOA No.: 19-0506.02 r�iar pj=jEjpj Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 8 of 9 LIMITATIONS: 13. The maximum roof slope for use as roof tile underlayment in direct-to-deck tile assemblies shall be as follows. Use of loading boards or batten strips is required on roof slopes greater than that reported in the Table below to prevent slippage. TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE ASSEMBLIES Underlayment Tile Profile Staging Method Maximum Slope Flintlastic GMS Flat/Lugged Max. 10-tile stack 4:12 Flintlastic GTA Flat/Lugged Max. 10-tile stack 6:12 Flat Max. 6-tile stack(4 over 6:12 Flintlastic SA 2) Cap Lugged Max. 6-tile stack(4 over 5:12 gg 2) END OF THIS ACCEPTANCE NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 9 of 9 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec See General Information • •• • Systems http://productspec.uI.com/document.php?id=TGFU.Rl1656 1/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 2/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 14/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 19/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 27/40 MIAMI•DADE MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy CertainTeed LLC 18 Moores Road Malvern,PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Flintlastic Self-Adhered Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#15-0622.21 and consists of pages I through 18. The submitted documentation was reviewed by Alex Tigera. NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 1 of 18 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: SBS Deck Type: Wood Maximum Design Pressure -127.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Spec Description Flintlastic SA NailBase 39 3/8"x 66'6'; Roll ASTM D 4601, Type Fiberglass reinforced, SBS modified weight: 821bs. I1 bitumen base sheet. (2 squares) Flintlastic SA P1yBase 39 3/8"x 66'6';Roll ASTM D4601, Self-adhering, fiberglass reinforced, SBS weight: 861bs. Type II modified bitumen base/ply sheet. (2 squares) All Weather/Empire Base 39 3/8" x 65'10"; ASTM D 4601 Type Asphalt coated, fiberglass reinforced base Sheet Roll weight: 70 lbs. I1 sheet. (2 squares) UL Type G2 Yosemite Venting Base 39 3/8" x 32'10';Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced Sheet weight: 85 lbs. ASTM D 4897, Type buffer sheet. (1 square) 11 UL Type G3 Flexiglas Base Sheet 39 3/8"x 98'9'; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass base weight: 90 lbs. 11 sheet. (3 squares) UL Type G2 Flintlastic Poly SMS Base 39 3/8" x 64' 3"; Roll ASTM D 4601, Modified Bitumen coated polyester base Sheet weight: 90 lbs. Grade S, Type 11 sheet. (2 squares) UL Type G2 Glasbase Base Sheet 39 3/8"x 98'9"; Roll ASTM D 4601 Type Asphalt coated, fiberglass base sheet. weight: 75 lbs. 11 (3 squares) UL Type G2 Flintlastic Ultra Poly 39 3/8" x 32' 10";Roll ASTM D 6164, Smooth surfaced SBS Modified Bitumen SMS Base Sheet weight: 90 lbs. Grade S,Type I Membrane with non-woven polyester mat (1 square) reinforcement for mop applications. Flintlastic SA Mid Ply 39 3/8"x 32'1"; ASTM D 6163, Self-adhering,polyester reinforced, SBS Roll weight: 62 lbs. Grade S,Type I modified bitumen ply sheet. (1 square) Flintlastic SA Cap FR 39 3/8"x 32'11'; Roll ASTM D 6163, Self-adhering, fiberglass reinforced, SBS weight: 88 lbs. Grade G, Type I modified bitumen cap sheet. (1 square) Flintlastic SA Cap 39 3/8"x 32'11'; Roll ASTM D 6164, Self-adhering,polyester reinforced, SBS weight: 95 lbs. Grade G, Type I modified bitumen cap sheet. (1 square) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 2 of 18 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Spec Description F1intPrime Asphalt 1, 3 or 5 gal pail ASTM D 41 Asphalt primer F1intPrime SA 1, 3 or 5 gal pail Proprietary Water-based,polymer modified primer. APPROVED INSULATIONS: TABLE 2 Product Product Description Manufacturer (with current NOA) F1intBoard ISO Polyisocyanurate insulation CertainTeed LLC F1intBoard ISOx Polyisocyanurate insulation CertainTeed LLC ACFoam-II Polyisocyanurate insulation Atlas Roofing Corp. ENRGY 3 Polyisocyanurate insulation Johns Manville Corp. H-Shield Polyisocyanurate insulation Hunter Panels, a div. of Carlisle Const. Materials Multi-Max FA-3 Polyisocyanurate insulation Rmax Operating,LLC. DensDeck Roof Board Gypsum coverboard Georgia Pacific Gypsum LLC. DensDeck Prime Roof Board Gypsum coverboard Georgia Pacific Gypsum LLC. SECUROCK Gypsum-Fiber Roof homogenous fiber reinforced USG Corp. Board NOA No.: 20-0131.01 MIAMI-DADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 3 of 18 APPROVED FASTENERS: TABLE 3 Fastener Manufacturer Number Product Name Product Description (with current NOA) 1. Dekfast DF-#14-PH3 Roofing screw SFS Group USA,Inc. 2. Trufast#14 HD Fastener Roofing screw Altenloh,Brinck&Co.U.S.,Inc. 3. #14 Roogrip Roofing screw OMG, Inc. 4. OMG Heavy Duty Roofing screw OMG, Inc. 5. F1intFast#14 Fastener Roofing screw CertainTeed LLC. 6. Dekfast DF-#12-PH3 Roofing screw SFS Group USA,Inc. 7. #12 Standard Roofgrip Insulation fastener OMG, Inc. 8. 3 in. Round Metal Plate 3" round galvalume AZ50 OMG, Inc. steel plate 9. Trufast#12 DP Fastener Roofing screw Altenloh,Brinck&Co. U.S., Inc. 10. F1intFast#12 Fastener Roofing screw CertainTeed LLC. 1 1. Dekfast PLT-H-2-7/8 hexagonal steel plate SFS Group USA,Inc. 12. Flat Bottom Metal Plate 3"square steel plate OMG,Inc. 13. Trufast 3"Metal Insulation 3"round steel plate Altenloh,Brinck&Co.U.S.,Inc. Plate 14. F1intFast 3"Metal 3"round steel plate CertainTeed LLC. Insulation Plate 15. ICP Adhesive CR-20 Polyurethane two component ICP Adhesives and Sealants,Inc. low rise insulation adhesive 16. Millennium One Step Polyurethane two component H.B. Fuller Company Foamable Adhesive high rise insulation adhesive 17. OMG OlyBond 500 Spray polyurethane foam OMG, Inc. Adhesive insulation adhesive 18. OMG OlyBond 500 Green Spray polyurethane foam OMG,Inc. Adhesive insulation adhesive 19. Pliodeck Insulation Polyurethane one component Ashland, Inc. Adhesive low VOC adhesive system 20. Insta Stik Quik Set Polyurethane one component The Dow Chemical Company Insulation Adhesive moisture curing adhesive NOA No.: 20-0131.01 MIIAMI-DADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 4 of 18 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating,listed below,used as a surfacing, must be listed within a current NOA. System Manufacturer Application Number 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 3001bs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak(#97 AF)Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. Gardner Asphalt Corp. APOC#212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 20-0131.01 MIAMMADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 5 of 18 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Underwriters Laboratories R11656 UL790 Annually Factory Mutual Research 2D5A9.AM FM 4450 06/22/99 3008869 FM 4470 03/19/01 3009610 FM 4450 10/15/01 3012321 FM 4450 07/29/02 3014692 FM 4450 08/05/03 3014751 FM 4450 08/12/03 3025766 FM 4470 11/13/06 3037127 FM 4470 01/11/10 3039046 FM 4470 06/15/10 3048520 FM 4470 09/19/13 Trinity ERD 3518.12.03 TAS 114-F/G/I 12/01/03 3521.07.04 TAS 1144&TAS 117(13) 07/28/04 3522.07.04 TAS 114-D 07/28/04 C8500SC.11.07-R1 ASTM D 6862/TAS 117(B) 08/07/09 C8370.08.08-R1 TAS 114-H/J&TAS 117(B) 10/05/09 C30310.12.09 TAS 114/TAS 117 12/17/09 C30560.06.10 TAS 114/TAS 117 06/10/10 C32830.07.10 FM 4470/TAS 114 07/20/10 C35500.02.11 TAS 117(13) 02/09/11 3513.08.02-R1 TAS 114/TAS 117 03/17/11 C3519.12.03-R1 TAS 114-D/J&TAS 117(B) 04/15/11 C35460.05.11 ASTM D1876 06/16/11 03515.07.03-1-R1 TAS 114-J&TAS 117(B) 06/27/12 C42110.08.12 TAS 114&TAS 117 08/13/12 C44580.07.13 ASTM D 1876, 07/25/13 TAS 114,FM 4474 C45620.03.14 ASTM D1876, TAS 114 (H), 03/27/14 FM 4474 C47350.50.14 FM 4470 05/22/14 NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 6 of 18 APPROVED ASSEMBLIES: Membrane Type: APP/SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type A(1): Anchor sheet mechanically fastened, optional top layer adhered with approved adhesive All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Yosemite Venting Base Sheet,Flexiglas Base Sheet,Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 3"lap and 8"o.c. in three, equally spaced center rows. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' H-Shield,FlintBoardx ISO,ACFoam II,FlintBoard ISO,ENRGY 3 or Multi-Max FA-3 Minimum 1.5"thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft2 DensDeck Roof Board,DensDeck Prime Roof Board Minimum 1/4"thick N/A N/A Note: Base insulation layer shall be adhered to the anchor sheet with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 4" o.c. Optional top layer of insulation shall be adhered to the base layer with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Top insulation layer shall be primed with FlintPrime SA at a rate of 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid-Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -52.5 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAWEL4DECQu Expiration Date: 04/13/25 1 Approval Date: 03/19/20 Page 7 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type A(2): Anchor sheet mechanically fastened, optional top layer adhered with approved adhesive All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Yosemite Venting Base Sheet,Flexiglas Base Sheet,Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 3"lap and 8"o.c. in three, equally spaced center rows. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener Table 3 Density/ft2 H-Shield,F1intBoardn ISO,ACFoam II,FlintBoard ISO,ENRGY 3 or Multi-Max FA-3 Minimum 1.5"thick N/A N/A Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 SECUROCK Gypsum-Fiber Roof Board Minimum'/4"thick N/A N/A Note: Base insulation layer shall be adhered with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 4" o.c. Top layer of insulation shall be adhered with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply Flint-Prime SA to SECUROCK Gypsum-Fiber Roof Board surface at 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid-Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -60 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 8 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: Min 19/32"thick or greater plywood or wood plank at max 24" spans attached 6"o.c.using 8d diameter ring shank nails. System Type C(1): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 F1intBoard ISO,ACFoam II,ENRGY 3, Multi-Max FA-3,H-Shield,FlintBoardH ISO Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 DensDeck Roof Board Minimum 1/"thick 1,2,3,4,5 1:1.33 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply FlintPrime SA to DensDeck Roof Board surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA Mid Ply, self-adhered. Ply Sheet: One or more layer of Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -45 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAWEL4DE Cf?ilJ Expiration Date: 04/13/25 1 Approval Date: 03/19/20 Page 9 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type C(2): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 F1intBoard ISO,ACFoam-II,ENRGY 3,Multi-Max FA-3,H-Shield,FlintBoardx ISO Minimum 1.5"thick 6 1:1.45 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply F1intPrime SA to insulation surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR,self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -60 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 10 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Deck 1: Min. 19/32"thick plywood attached using approved#8 wood screws spaced 6" o.c. at wood joists spaced max. 24"o.c. Deck 2: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c. at wood joists spaced maximum 24"o. c System Type E(1): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid. (Optional) Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 4"lap and 8"o.c. in three, equally spaced center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design For Deck 1: -52.5 psf(See General Limitation#7.) Pressure: For Deck 2: -60.0 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 11 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32" thick plywood attached using 8d ring shank nails spaced 6"o.c. at wood joists spaced maximum 24"o.c. System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of G1asBase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf(See General Limitation#7.) Pressure: NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJl+1TY Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 12 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using#8 wood screws. System Type E(3): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6"o.c. at the 3" lap and 6"o.c. in three, equally spaced center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 75 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 13 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using#8 wood screws. System Type E(4): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with OMG#12 Standard Roofgrip with OMG 3 in. Round Metal Plates spaced 8"o.c. at the 3"lap and 8 o.c. in two, equally spaced center rows. Primer: Apply ASTM D41 primer to stress plates. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 82.5 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 14 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32" thick plywood attached using #10 wood screws spaced 6"o.c. at wood joists spaced maximum 24"o.c. System Type E(5): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of GlasBase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: OMG 3 in. Round Metal Plates with OMG #14 Heavy Duty fasteners or TruFast 3" Metal Insulation Plate with TruFast#12 DP or TruFast#14 HD Fasteners or FlintFast 3"Insulation Plates with FlintFast#12 or FlintFast#14 Fasteners spaced 6" o.c. at the 4" lap and 6" o.c. in three, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -97.5 psf. (See General Limitation#7) NOA No.: 20-0131.01 MIAWEL4DECQu Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 15 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24" spans attached 6"o.c.using#8 wood screws. System Type E(6): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4"o.c. at the 3" lap and 4"o.c. in four, equally spaced center rows for a total of five rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 105 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 16 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32" thick plywood attached using#10 wood screws spaced 4"o.c. at wood joists spaced maximum 24"o.c. System Type E(7): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: OMG 3 in. Round Metal Plates with OMG #14 Heavy Duty fasteners or TruFast 3" Metal Insulation Plate with TruFast#12 DP or TruFast#14 HD Fasteners or F1intFast 3" Insulation Plates with FlintFast #12 or #14 Fasteners spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -127.5 psf. (See General Limitation#7) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 17 of 18 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 20-0131.01 MIAMId9AM Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 18 of 18 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec See General Information • •• • Systems http://productspec.uI.com/document.php?id=TGFU.Rl1656 1/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 2/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 14/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 19/40 3/18/2019 CERTAINTEED CORP,TGFU.R11656-UL Product Spec http://productspec.uI.com/document.php?id=TGFU.Rl1656 27/40 MIAMI•DADE MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy CertainTeed LLC 18 Moores Road Malvern,PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Flintlastic Self-Adhered Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#15-0622.21 and consists of pages I through 18. The submitted documentation was reviewed by Alex Tigera. NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 1 of 18 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: SBS Deck Type: Wood Maximum Design Pressure -127.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Spec Description Flintlastic SA NailBase 39 3/8"x 66'6'; Roll ASTM D 4601, Type Fiberglass reinforced, SBS modified weight: 821bs. I1 bitumen base sheet. (2 squares) Flintlastic SA P1yBase 39 3/8"x 66'6';Roll ASTM D4601, Self-adhering, fiberglass reinforced, SBS weight: 861bs. Type II modified bitumen base/ply sheet. (2 squares) All Weather/Empire Base 39 3/8" x 65'10"; ASTM D 4601 Type Asphalt coated, fiberglass reinforced base Sheet Roll weight: 70 lbs. I1 sheet. (2 squares) UL Type G2 Yosemite Venting Base 39 3/8" x 32'10';Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced Sheet weight: 85 lbs. ASTM D 4897, Type buffer sheet. (1 square) 11 UL Type G3 Flexiglas Base Sheet 39 3/8"x 98'9'; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass base weight: 90 lbs. 11 sheet. (3 squares) UL Type G2 Flintlastic Poly SMS Base 39 3/8" x 64' 3"; Roll ASTM D 4601, Modified Bitumen coated polyester base Sheet weight: 90 lbs. Grade S, Type 11 sheet. (2 squares) UL Type G2 Glasbase Base Sheet 39 3/8"x 98'9"; Roll ASTM D 4601 Type Asphalt coated, fiberglass base sheet. weight: 75 lbs. 11 (3 squares) UL Type G2 Flintlastic Ultra Poly 39 3/8" x 32' 10";Roll ASTM D 6164, Smooth surfaced SBS Modified Bitumen SMS Base Sheet weight: 90 lbs. Grade S,Type I Membrane with non-woven polyester mat (1 square) reinforcement for mop applications. Flintlastic SA Mid Ply 39 3/8"x 32'1"; ASTM D 6163, Self-adhering,polyester reinforced, SBS Roll weight: 62 lbs. Grade S,Type I modified bitumen ply sheet. (1 square) Flintlastic SA Cap FR 39 3/8"x 32'11'; Roll ASTM D 6163, Self-adhering, fiberglass reinforced, SBS weight: 88 lbs. Grade G, Type I modified bitumen cap sheet. (1 square) Flintlastic SA Cap 39 3/8"x 32'11'; Roll ASTM D 6164, Self-adhering,polyester reinforced, SBS weight: 95 lbs. Grade G, Type I modified bitumen cap sheet. (1 square) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 2 of 18 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Spec Description F1intPrime Asphalt 1, 3 or 5 gal pail ASTM D 41 Asphalt primer F1intPrime SA 1, 3 or 5 gal pail Proprietary Water-based,polymer modified primer. APPROVED INSULATIONS: TABLE 2 Product Product Description Manufacturer (with current NOA) F1intBoard ISO Polyisocyanurate insulation CertainTeed LLC F1intBoard ISOx Polyisocyanurate insulation CertainTeed LLC ACFoam-II Polyisocyanurate insulation Atlas Roofing Corp. ENRGY 3 Polyisocyanurate insulation Johns Manville Corp. H-Shield Polyisocyanurate insulation Hunter Panels, a div. of Carlisle Const. Materials Multi-Max FA-3 Polyisocyanurate insulation Rmax Operating,LLC. DensDeck Roof Board Gypsum coverboard Georgia Pacific Gypsum LLC. DensDeck Prime Roof Board Gypsum coverboard Georgia Pacific Gypsum LLC. SECUROCK Gypsum-Fiber Roof homogenous fiber reinforced USG Corp. Board NOA No.: 20-0131.01 MIAMI-DADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 3 of 18 APPROVED FASTENERS: TABLE 3 Fastener Manufacturer Number Product Name Product Description (with current NOA) 1. Dekfast DF-#14-PH3 Roofing screw SFS Group USA,Inc. 2. Trufast#14 HD Fastener Roofing screw Altenloh,Brinck&Co.U.S.,Inc. 3. #14 Roogrip Roofing screw OMG, Inc. 4. OMG Heavy Duty Roofing screw OMG, Inc. 5. F1intFast#14 Fastener Roofing screw CertainTeed LLC. 6. Dekfast DF-#12-PH3 Roofing screw SFS Group USA,Inc. 7. #12 Standard Roofgrip Insulation fastener OMG, Inc. 8. 3 in. Round Metal Plate 3" round galvalume AZ50 OMG, Inc. steel plate 9. Trufast#12 DP Fastener Roofing screw Altenloh,Brinck&Co. U.S., Inc. 10. F1intFast#12 Fastener Roofing screw CertainTeed LLC. 1 1. Dekfast PLT-H-2-7/8 hexagonal steel plate SFS Group USA,Inc. 12. Flat Bottom Metal Plate 3"square steel plate OMG,Inc. 13. Trufast 3"Metal Insulation 3"round steel plate Altenloh,Brinck&Co.U.S.,Inc. Plate 14. F1intFast 3"Metal 3"round steel plate CertainTeed LLC. Insulation Plate 15. ICP Adhesive CR-20 Polyurethane two component ICP Adhesives and Sealants,Inc. low rise insulation adhesive 16. Millennium One Step Polyurethane two component H.B. Fuller Company Foamable Adhesive high rise insulation adhesive 17. OMG OlyBond 500 Spray polyurethane foam OMG, Inc. Adhesive insulation adhesive 18. OMG OlyBond 500 Green Spray polyurethane foam OMG,Inc. Adhesive insulation adhesive 19. Pliodeck Insulation Polyurethane one component Ashland, Inc. Adhesive low VOC adhesive system 20. Insta Stik Quik Set Polyurethane one component The Dow Chemical Company Insulation Adhesive moisture curing adhesive NOA No.: 20-0131.01 MIIAMI-DADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 4 of 18 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating,listed below,used as a surfacing, must be listed within a current NOA. System Manufacturer Application Number 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 3001bs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak(#97 AF)Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. Gardner Asphalt Corp. APOC#212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 20-0131.01 MIAMMADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 5 of 18 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Underwriters Laboratories R11656 UL790 Annually Factory Mutual Research 2D5A9.AM FM 4450 06/22/99 3008869 FM 4470 03/19/01 3009610 FM 4450 10/15/01 3012321 FM 4450 07/29/02 3014692 FM 4450 08/05/03 3014751 FM 4450 08/12/03 3025766 FM 4470 11/13/06 3037127 FM 4470 01/11/10 3039046 FM 4470 06/15/10 3048520 FM 4470 09/19/13 Trinity ERD 3518.12.03 TAS 114-F/G/I 12/01/03 3521.07.04 TAS 1144&TAS 117(13) 07/28/04 3522.07.04 TAS 114-D 07/28/04 C8500SC.11.07-R1 ASTM D 6862/TAS 117(B) 08/07/09 C8370.08.08-R1 TAS 114-H/J&TAS 117(B) 10/05/09 C30310.12.09 TAS 114/TAS 117 12/17/09 C30560.06.10 TAS 114/TAS 117 06/10/10 C32830.07.10 FM 4470/TAS 114 07/20/10 C35500.02.11 TAS 117(13) 02/09/11 3513.08.02-R1 TAS 114/TAS 117 03/17/11 C3519.12.03-R1 TAS 114-D/J&TAS 117(B) 04/15/11 C35460.05.11 ASTM D1876 06/16/11 03515.07.03-1-R1 TAS 114-J&TAS 117(B) 06/27/12 C42110.08.12 TAS 114&TAS 117 08/13/12 C44580.07.13 ASTM D 1876, 07/25/13 TAS 114,FM 4474 C45620.03.14 ASTM D1876, TAS 114 (H), 03/27/14 FM 4474 C47350.50.14 FM 4470 05/22/14 NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 6 of 18 APPROVED ASSEMBLIES: Membrane Type: APP/SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type A(1): Anchor sheet mechanically fastened, optional top layer adhered with approved adhesive All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Yosemite Venting Base Sheet,Flexiglas Base Sheet,Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 3"lap and 8"o.c. in three, equally spaced center rows. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' H-Shield,FlintBoardx ISO,ACFoam II,FlintBoard ISO,ENRGY 3 or Multi-Max FA-3 Minimum 1.5"thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft2 DensDeck Roof Board,DensDeck Prime Roof Board Minimum 1/4"thick N/A N/A Note: Base insulation layer shall be adhered to the anchor sheet with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 4" o.c. Optional top layer of insulation shall be adhered to the base layer with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Top insulation layer shall be primed with FlintPrime SA at a rate of 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid-Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -52.5 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAWEL4DECQu Expiration Date: 04/13/25 1 Approval Date: 03/19/20 Page 7 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type A(2): Anchor sheet mechanically fastened, optional top layer adhered with approved adhesive All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Yosemite Venting Base Sheet,Flexiglas Base Sheet,Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 3"lap and 8"o.c. in three, equally spaced center rows. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener Table 3 Density/ft2 H-Shield,F1intBoardn ISO,ACFoam II,FlintBoard ISO,ENRGY 3 or Multi-Max FA-3 Minimum 1.5"thick N/A N/A Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 SECUROCK Gypsum-Fiber Roof Board Minimum'/4"thick N/A N/A Note: Base insulation layer shall be adhered with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 4" o.c. Top layer of insulation shall be adhered with ICP Adhesive CR-20, Millennium One Step Foamable Adhesive, OMG OlyBond 500, OMG OlyBond Green Adhesive, Pliodeck Insulation Adhesive or Insta Stik Quik Set Insulation Adhesive spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply Flint-Prime SA to SECUROCK Gypsum-Fiber Roof Board surface at 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid-Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -60 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 8 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: Min 19/32"thick or greater plywood or wood plank at max 24" spans attached 6"o.c.using 8d diameter ring shank nails. System Type C(1): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 F1intBoard ISO,ACFoam II,ENRGY 3, Multi-Max FA-3,H-Shield,FlintBoardH ISO Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 DensDeck Roof Board Minimum 1/"thick 1,2,3,4,5 1:1.33 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply FlintPrime SA to DensDeck Roof Board surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA Mid Ply, self-adhered. Ply Sheet: One or more layer of Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -45 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAWEL4DE Cf?ilJ Expiration Date: 04/13/25 1 Approval Date: 03/19/20 Page 9 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood,Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type C(2): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 F1intBoard ISO,ACFoam-II,ENRGY 3,Multi-Max FA-3,H-Shield,FlintBoardx ISO Minimum 1.5"thick 6 1:1.45 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply F1intPrime SA to insulation surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR,self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -60 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 10 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Deck 1: Min. 19/32"thick plywood attached using approved#8 wood screws spaced 6" o.c. at wood joists spaced max. 24"o.c. Deck 2: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c. at wood joists spaced maximum 24"o. c System Type E(1): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid. (Optional) Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 4"lap and 8"o.c. in three, equally spaced center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design For Deck 1: -52.5 psf(See General Limitation#7.) Pressure: For Deck 2: -60.0 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 11 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32" thick plywood attached using 8d ring shank nails spaced 6"o.c. at wood joists spaced maximum 24"o.c. System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of G1asBase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf(See General Limitation#7.) Pressure: NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJl+1TY Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 12 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using#8 wood screws. System Type E(3): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6"o.c. at the 3" lap and 6"o.c. in three, equally spaced center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 75 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 13 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using#8 wood screws. System Type E(4): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with OMG#12 Standard Roofgrip with OMG 3 in. Round Metal Plates spaced 8"o.c. at the 3"lap and 8 o.c. in two, equally spaced center rows. Primer: Apply ASTM D41 primer to stress plates. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 82.5 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 14 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32" thick plywood attached using #10 wood screws spaced 6"o.c. at wood joists spaced maximum 24"o.c. System Type E(5): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of GlasBase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: OMG 3 in. Round Metal Plates with OMG #14 Heavy Duty fasteners or TruFast 3" Metal Insulation Plate with TruFast#12 DP or TruFast#14 HD Fasteners or FlintFast 3"Insulation Plates with FlintFast#12 or FlintFast#14 Fasteners spaced 6" o.c. at the 4" lap and 6" o.c. in three, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -97.5 psf. (See General Limitation#7) NOA No.: 20-0131.01 MIAWEL4DECQu Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 15 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24" spans attached 6"o.c.using#8 wood screws. System Type E(6): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4"o.c. at the 3" lap and 4"o.c. in four, equally spaced center rows for a total of five rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 105 psf(See General Limitation#7.) NOA No.: 20-0131.01 MIAMId9ADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 16 of 18 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32" thick plywood attached using#10 wood screws spaced 4"o.c. at wood joists spaced maximum 24"o.c. System Type E(7): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: OMG 3 in. Round Metal Plates with OMG #14 Heavy Duty fasteners or TruFast 3" Metal Insulation Plate with TruFast#12 DP or TruFast#14 HD Fasteners or F1intFast 3" Insulation Plates with FlintFast #12 or #14 Fasteners spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -127.5 psf. (See General Limitation#7) NOA No.: 20-0131.01 MIAMIOADE Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 17 of 18 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 20-0131.01 MIAMId9AM Cf?ilJ Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 18 of 18 3/20/2019 CERTAINTEED CORP,TFWZ.R684-UL Product Spec See General Information for Prepared Roof-covering Materials http://productspec.ul.com/document.php?id=TFWZ.R684 1/3 3/20/2019 CERTAINTEED CORP,TFWZ.R684-UL Product Spec http://productspec.ul.com/document.php?id=TFWZ.R684 2/3 3/20/2019 CERTAINTEED CORP,TFWZ.R684-UL Product Spec http://productspec.ul.com/document.php?id=TFWZ.R684 3/3 M IAM I•DiADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Landmark,Landmark Pro,Landmark Pro/Archetect 80,Landmark Premium,Landmark Impact Resistant,Landmark Solaris,Landmark Pro Solaris and Landmark Solaris Gold/Platinum LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 17-1211.08 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino �•- NOA No.: 18-1114.02 MIAMMALDE COUNTY Expiration Date: 02/28/22 �MINWMAPJ Approval Date: 05/09/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials Dimensional Deck Type: Wood SCOPE This acceptance is for CertainTeed Landmark, Landmark Pro, Landmark Pro/Architect 80, Landmark Premium, Landmark Impact Resistant, Landmark Solaris, Landmark Pro Solaris and Landmark Solaris Gold/Platinum Shingles as manufactured by CertainTeed Corporation described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION: Test Product Dimensions Specifications Product Descri tion Certainteed Landmark Manufacturing Locations#1, 2, 3,4, 5, 6, 7, 8, 9, 13%4" x 38 3/4" TAS 110 A heavy weight, dimensional 10 asphalt shingle. Certainteed Landmark Pro A heavy weight, dimensional Manufacturing Locations#1, 3,4, 5, 6, 9, 10 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Premium A heavy weight, dimensional Manufacturing Locations#1, 3,4, 5, 6, 8, 9 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Impact Resistant A heavy weight, dimensional Manufacturing Locations#7 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Pro/Architect 80 A heavy weight, dimensional Manufacturing Locations#8 131/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Solaris A heavy weight, dimensional Manufacturing Locations#8, 9 131/4" x 38 3/4" TAS 110 asphalt shingle. CertainTeed Landmark Pro Solaris 131/4" x 38 3/4" TAS 110 A heavy weight, dimensional Manufacturing Location#9 asphalt shingle Certainteed Landmark Solaris Gold/Platinum A heavy weight, dimensional Manufacturing Locations#8 131/4" x 38 3/4" TAS 110 asphalt shingle. Accessory Shingles Accessory shingles for hip,ridge various proprietary and starter strip applications. MANUFACTURING LOCATIONS: 1. Peachtree City, GA 2. Ennis, TX 3. Oxford,NC 4. Shakopee,MN NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 2 of 7 5. Avery(Milan), OH 6. Norwood, MA 7. Shreveport,LA 8. Portland, OR 9. Wilmington, CA 10. Jonesburg,MO EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies, Inc. PCTC-01-02-01 TAS 100 01/12/01 CTC-006-02-01 TAS 100 11/12/02 CTC-092-02-01 TAS 100 02/23/12 CTC-091-02-01 TAS 100 02/21/12 CTC-090-02-01 TAS 100 09/02/11 CTC-087-02-01 TAS 100 07/07/11 CTC-086-02-01 TAS 100 07/07/11 CTC-101-02-01 TAS 100 10/05/11 CTC-102-02-01 TAS 100 10/05/11 CTC-109-02-01 TAS 100 01/18/12 CTC-106-02-01 TAS 100 11/02/11 CTC-105-02-01 TAS 100 10/31/11 CTC-089-02-01 TAS 100 07/18/11 CTC-088-02-01 TAS 100 07/18/11 CTC-213-02-01 TAS 100 05/20/14 CTC-212-02-01 TAS 100 05/21/14 CTC-207-02-01 TAS 100 05/20/14 CTC-206-02-01 TAS 100 05/20/14 CTC-110-02-01 TAS 100 02/13/12 CTC-109-02-01 TAS 100 02/13/12 CTC-288-02-01 TAS 100 09/27/16 CTC-333-02-01 TAS 100 11/08/17 Underwriters Laboratories,Inc. 94NK9632 Wind uplift resistance TAS 107 11/30/00 R684 UL 790 04/02/01 02NK42448 Wind uplift resistance TAS 107 11/08/02 09CA28873 Letter 07/23/09 11CA59020 TAS 107/ASTM D3161 01/25/12 1INK07864 TAS 107/ASTM D3161 09/29/11 07CA26696 TAS 107/ASTM D3161 09/21/07 I ICA38844 TAS 107/ASTM D3161 01/28/12 I ICA38844 TAS 107/ASTM D3161 01/27/12 06CA28237 TAS 107/ASTM D3161 09/22/06 IONK17366 TAS 107/ASTM D3161 01/04/11 4786334383 TAS 107/ASTM D3161 05/28/14 4786307351 TAS 107/ASTM D3161/ASTM D 3462 05/13/14 NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 3 of 7 11NK08333 ASTM D3462 05/15/12 11NK08333 ASTM D3462 04/15/12 11NK07864 ASTM D3462 09/29/11 11NK08333/Letter ASTM D3462/UL790 11/05/12 11NK08333/Letter ASTM D3462/UL790 11/05/12 11NK08333/Letter ASTM D3462/UL790 11/05/12 12NK13474 ASTM D3462/UL790 05/27/13 4786325932 ASTM D3462/UL790 04/04/14 4787011023 ASTM D 3462 08/01/15 11CA38844 TAS 107/ASTM D3161 01/26/12 06CA02648 TAS 107/ASTM D3161 02/23/06 4787084802 TAS 107/ASTM D3161 03/14/16 4787852839 ASTM D3462 03/24/17 4787011023 ASTM D3462 08/01/15 4788368979 ASTM D3462 10/30/18 4787592174 ASTM D3462 10/21/16 LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION: 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail'B', attached. NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 4 of 7 LABELING: 1. Shingles shall be labeled with the Miami-Dade Product Control approved seal as seen below or the wording "Miami-Dade County Product Control Approved". MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS: 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 5 of 7 SHINGLE LAYOUT Rake Edge 8--I S� 16 3/4 6 11 5� 11 27 3/4 6~� 6 32 3/4 5 518 FUII Starter Shingle Eaves LANDMARK, LANDMARK PRO,LANDMARK PRO/ARCHITECT 80,LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT,LANDMARK SOLARIS,LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 6 of 7 DETAIL++B im, 383140 �I Release Ta$+e Nailing area far"IDw&standard slopes(from 2:12 to 21:12) Nail between uppers lGwernall lines. 12" 14 3J4" 12" ,F 'Pi 13 114" VVIDE 1, 1 NAILING — AREA E r �7 V2- Exposure ll LANDMARK,LANDMARK PRO,LANDMARK PRO/ARCHETECT 80,LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT,LANDMARK SOLARIS,LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM (LOW AND STANDARD SLOPE Release Tape Nailing area for"steep"slopes(greater than 21:12) Nail between bottom 2 nail lines. 12" 14 3/4" 12" 13 1/4" 1 1 5 5/8" 6 1/8" Exposure LANDMARK,LANDMARK PRO,LANDMARK PRO/ARCHETECT 80, LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT,LANDMARK SOLARIS,LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM (STEEP SLOPE END OF THIS ACCEPTANCE NOA No.: 18-1114.02 MIAMI•DADE COUNTY Expiration Date: 02/28/22 + Approval Date: 05/09/19 Page 7 of 7 1'4lAWl �„ ..� MIAMI-DARE COUNTY rmi lIIL PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 r T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economv CertainTeed Corporation 1400 Union Meeting Road Blue Bell,PA 19422 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. F 1 DESCRIPTION:CertainTeed Shangle Ridge,Shadow Ridge,Hatteras Accessory,Presidential Accessory,and E Cedar Crest Hip and Ridge Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 12-0611.02 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0824.05 NMI•T7 MIAAD;COUNTY Expiration Date: 11/15/221/15/22 Approval Date: 11/16/17 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category' ! Roofing Sub-Category: Asphalt Shingles Materials # Laminated Deck Type: f Wood I SCOPE This approves CertainTeed Shangle Ridge, Shadow Ridge,Hatteras Accessory, Presidential Accessory and Cedar Crest Hip and Ridge Shingles as manufactured by CertainTeed Corporation(PA)and described in Section 2 of this Notice of Acceptance. E PRODUCT DESCRIPTION Product Dimensions Test Product Description i Specifications Shangle Ridge 12"x 18" TAS 110 A pre-assembled, double layer hip and Manufacturing Location(s) #1 ridge fiberglass reinforced asphalt shingle with an 8"exposure. Shadow Ridge 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #1,2,3,4 reinforced asphalt shingle with an 5" exposure. Hatteras Accessory 12"x 18" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #1 reinforced asphalt shingle with an 8" exposure. Presidential Accessory 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #2 reinforced asphalt shingle with an 5" exposure. Cedar Crest 12"x 12" TAS 110 A pre-assembled hip and ridge fiberglass Manufacturing Location(s) #1 reinforced asphalt shingle with an 8" k exposure. PRODUCTS MANUFACTURED BY OTHERS Product Product Description Size Manufacturer Any approved sealant with a current Miami Sealant various Any approved manufacturer Dade NOA (with a current Miami Dade NOA) Any approved adhesive with a current ASTM C920,Type S, various Any approved manufacturer Miami Dade NOA Grade NS,min Class 25 (with a current Miami Dade NOA) i 1 F r i NOA No.: 17-0824.05 M"10MADE co�awrr Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 2 of 9 3 MANUFACTURING LOCATION 1. Oxford,NC. 2. Shakopee,MN. 3. Avery, OH 4. Norwood,MA. j EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies,Inc. CTC-028-02-01 ASTM D 6381 08/06/07 CTC-021-02-01 TAS 100(A) 05/16/06 CTC-029-02-01 TAS 100(A) 08/06/07 CTC-030-02-01 TAS 100(A) 08/06/07 CTC-020-02-01 TAS 100(A) 05/16/06 CTC-072-02-01 TAS 100(A) 02/10/11 CTC-334-02-01 TAS 107 08/29/17 CTC-330-02-01 TAS 107 08/27/17 CTC-310-02-01 TAS 100(A) 05/31/17 CTC-311-02-01 TAS 100(A) 05/31/17 CTC-312-02-01 TAS 100(A) 05/31/17 j CTC-315-02-01 TAS 100(A) 06/19/17 j CTC-314-02-01 TAS 100(A) 06/19/17 Underwriters Laboratories,Inc. 07CA30825 ASTM D 3161 08/06/07 R684 ASTM D 3462 08/04/04 I R684 ASTM D 3462 08/05/04 IOCA44960 ASTM D 3462 11/11/10 j IOCA44960 ASTM D 3161 11/11/10 4787855169 ASTM D 3161/3462 07/27/17 4787855164 ASTM D 3161/3462 06/27/17 4787867612 ASTM D 3161/3462 07/26/17 4787855162 ASTM D 3161/3462 06/26/17 4787855167 ASTM D 3161/3462 06/30/17 1 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Layout Details herein NOA No.: 17-0824.05 MIAMI•DADE COUNTY . , Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 3 of 9 i i l j e LABELING j 1. Ridge Cap Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade County Product Control Approved". CMIAMI-MADECRONTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 Thi`s Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. E LAYOUT DETAILS SHANGLE RIDGE RemDw tape tr0fn th6 ti9N Sid6 d and tstan E SECOND FaSten#h�� I Side 8 All RIGHT Fi R LEFT I 1 Nu�re NOA No.: 17-0824.05 cour�rr Expiration Date: 11/15/22 1 Approval Date: 11/16/17 Page 4 of 9 i i k SHADOW RIDGE i l MI { I � i HATTERAS ACCESSORY 1 } i I G i 4 I 4( f I i i NOA No.: 17-0824.05 MMI-DADE COUN W Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 5 of 9 I PRESIDENTIAL ACCESSORY i 1 i i I i CEDAR CREST Sealed! Sealant 4-Starter Plem i I CMI-MADEUNTYNOA No.: 17-0824.05 •••. Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 6 of 9 f s i i f a NAILING DETAILS i i SHANGLE RIDGE 12° 1/4"wide bead of adheslve,7" long, �" (ao5 mm 'l 3/4"-1" from side edge of cap shingle I - (25 mm (26 mm) 18" B M (457 mm) (219 Inm) { Failing pattern all applications -two mils per shingle. SHADOW RIDGE 1/4 wrfde bead of adhegive,3n-3112®long, � (306 mm) -"1 3/4"4"from side adge of cap;rhingle J: 1" (25 mm) ... (2S mm) 12' N yk .��11171� '�{�7 ITtm (1 4 f Nailing pattern all applications -two nails per shingle. I ' I { NOA No.: 17-0824.05 ' MIAMMADE CCUFITY Expiration Date: 11/15/22 i Approval Date: 11/16/17 Page 7 of 9 I s i i HATTERAS ACCESSORY 12" IM" wide knead of adhesive, Y tong, 305 mm)�`� 3/44'-1"'from side edge of cap shingle 1" 1" (26 rr •*• ••■ ( 6 mnn ,.... ... .. 18" 9 t " (457 mm) (286 mrn) f Nailing pattern all applications-two mails per shingle, PRESIDENTIAL ACCESSORY 1/4"wide bead ai adhesive, 3"-3112" long, 12y 3/4"A from sine edge of Gap shingle (305 mtn)r" i 1" 1" (25 mm} (2a mm) 1211 a we �305 mrn) (143 1 mm) Nailing pattern all applicatlons-two rims per shingle. { MIAMI•D®UNrr NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 8 of 9 1 CEDAR CREST 1/4''wide bead of adhesive,4"long, 3/4"-1"from side edge of cap shingle .fir-z.,�;•;:.,Overlay�;,.,.:.., ...`0'. 1"(25 mm) 12" 8 5/8" (305 mm) (219 mm) 12" I (305 mm) Nailing pattern all applications -two nails per shingle. END OF THIS ACCEPTANCE NOA No.: 17-0824.05 MI 1-12[11 C4UN7Y Expiration Date: 11/15/22 •� r Approval Date: 11/16/17 Page 9 of 9 HIA,I MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy CertainTeed Corporation 20 Moores Road Malvern,PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Ridge Vent 12" Filtered and 9" Filtered LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 15-0831.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Materials: Plastic Maximum Design Pressure: N/A Fire Classification: N/A TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene low profile attic ridge vent 12" Filtered herein for installation in shingle roof systems. CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene low profile attic ridge vent 9" Filtered herein for installation in shingle roof systems MANUFACTURING LOCATION 1. Orrick,MO EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Architectural Testing,Inc. TAS 100A(95) 6457.01-109-18 08/08/06 TAS 100A(95) 65453.01-109-18 08/08/06 PRI Construction Materials Technologies ASTM G 155 AVIG-006-02-01 10/18/11 ASTM G 1929 AVIG-005-02-01 10/18/11 ASTM D 635 AVIG-005-02-01 10/18/11 ASTM D 2843 AVIG-005-02-01 10/18/11 NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 2 of 4 APPROVED APPLICATIONS: Tradename: CertainTeed Ridge Vent 12"Filtered,and CertainTeed Ridge Vent 9"Filtered System Type: Mechanical attachment of static vent over asphalt shingle roof systems only. Slot: Cut a minimum 1'/Z" slot along the apex of the roof by cutting 3/4" on each side of the ridge. The slot shall terminate approximately 6" from the rake edge. Installation: Place ridge vent section centered over the void at one end of the ridge. Plugged end should be flush with end wall of ventilated space under roof. Pre-fasten first section using roofing nails through pre-drilled nail bosses. Continue to pre-fasten remaining sections,making sure support walls are flat on roof and filter is secure between shingles and vent. Cut final section to length. Ridge Shingle: Nail cap shingles in place using roofing nails long enough to penetrate through the roof sheathing a minimum of 3/16 of an inch. Use nail lines provided on vent. Net Free Area: Refer to manufacturers published literature. Minimum Slope: 2:12 LIMITATIONS: 1. Refer to applicable Building Codes for required ventilation. 2. This acceptance is for installations over asphalt shingle roof systems only. 3. CertainTeed Ridge Vent 12"Filtered,and CertainTeed Ridge Vent 9"Filtered Ridge Vents shall not be installed on roof mean heights greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 3 of 4 DETAIL DRAWINGS 11.0 R4.9 r 400 � 18° l.Q 2.5 .18 O.S. b.= op 13.8 CERTAINTEED RIDGE VENT- 1211 FILTERED iL C .S. 3.5 5.2 113 CERTAINTEED RIDGE VENT- 9" FILTERED END OF THIS ACCEPTANCE NOA No.: 17-0213.07 MIAMI-DADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 4 of 4 MIAMI•DIADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.2ov/eeonomv CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Underlayment Systems LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-0306.07 and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Semino Im �- NOA No.: 19-0506.02 MIAMI•DAD,COUNTY Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS SCOPE: This approves CertainTeed Underlayment Systems, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specification Description WinterGuard HT 36"x 65' ASTM D 1970 Modified fiberglass reinforced,bituminous sheet Manufacturing Location rolls material for use as an underlayment in sloped roof #1 assemblies. Designed as an ice&rain shield. WinterGuard Granular 36"x 65' ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Manufacturing Location rolls bituminous sheet material for use as an #2 underlayment in sloped roof assemblies. Designed as an ice&rain shield. WinterGuard Sand 36"x 32.5' ASTM D 1970 Embedded sand surfaced modified, fiberglass Manufacturing Location rolls reinforced,bituminous sheet material for use as an #2 underlayment in sloped roof assemblies. Designed as an ice&rain shield. Diamond Deck"" 48"x 250' ASTM D 226 Synthetic, scrim reinforced underlayment for use Manufacturing Location rolls Type 11 under shake, shingles, slate or metal roofing. #3, 4, & 6 MetaLaymenem 39 3/8 "x 61' ASTM D 1970 A film surfaced, self-adhering underlayment for Manufacturing Location rolls use under metal roofing. #1 Black Diamond"' 39 3/8"x 68' 7" ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Base Sheet rolls bituminous sheet material for use as an Manufacturing Location underlayment in sloped roof assemblies. #2 Designed as an ice&rain shield. Not for use as an Anchor Sheet.Direct adhesion to wood deck not permitted in the HVHZ. NOA No.: 19-0506.02 Miar�i•oaoe[ouNTv Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 2 of 9 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specification Description Flintlastic GTA 39 3/s" x 32' 10" ASTM D 6222 Granule surfaced APP Modified Bitumen Manufacturing Location rolls Grade G membrane with non-woven polyester mat #1 Type I reinforcement for torch application. All Weather/Empire 39 3/8"x 65' 10" ASTM D 4601 Asphalt coated fiberglass reinforced base sheet. Base Sheet rolls Type II Manufacturing Location #1 Flintlastic GMS 39 3/8"x 32'10" ASTM D 6164 Granule surfaced SBS Modified Bitumen Manufacturing Location rolls Grade G membrane with non-woven polyester mat #1 Type I reinforcement for mop application. Flintlastic SA Cap 39 3/8"x 33'11" TAS 103 Polyester reinforced, self-adhering SBS modified Manufacturing rolls bitumen cap sheet. Location#1 Roofers' Select 36"x 144' rolls ASTM D226 An asphalt-impregnated, organic felt reinforced Manufacturing Type I with glass fibers,roofing underlayment. Location#5 RoofRunner 48"x 250 rolls ASTM D226 Synthetic, scrim reinforced underlayment for use Manufacturing Type II under asphalt shingles. Location#6 MANUFACTURING LOCATION: 1. Little Rock,AR. 2. Shakopee,MN 3. Hangzhou, China 4. Silvassa,India 5. Shreveport,LA 6. Dadra,India NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 3 of 9 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date TrinitylERD 3530.12.05-1-R1 ASTM D1623 10/05/09 C32240.03.10 ASTM D4977 03/04/10 C30890.03.10-1 ASTM D1970 03/17/10 C3500.04.10 TAS 103 04/01/10 C31860.05.10 ASTM D1623 05/18/10 C40050.09.12-2 ASTM D1970 09/28/12 C45240.01.14-1 ASTM D1970, TAS 110 01/15/14 C32930.01.1 I-R2 ASTM D1623 01/20/14 C45240.01.14-2 TAS 103, TAS 110 01/24/14 SC6465.05.14 ASTM D 226 05/29/14 SC7470.10.14 TAS 114 B 10/21/14 CTR-SC11145.09-3A ASTM D4601 09/19/16 CTR-SC11415.11.16 TAS 103 11/28/16 CTR-SC11505.12.16 ASTM D1623 12/22/16 ACT-SC14110.06.17-1 ASTM D 226 06/29/17 ACT-SC14110.06.17-3 ASTM D 226 06/29/17 PRI Construction Materials CTC-071-02-01 ASTM D6222 08/08/11 Technologies, LLC CTC-093-02-01 ASTM D6164,ASTM D4798 08/09/11 CTC-163-02-01 ASTM D6757,ASTM D226, 05/09/13 ASTM D4869 InterTek Testing Services Ltd. 10103165000Q-002C ASTM D226 08/13/13 101227796COQ-003C ASTM D4798 08/13/13 10103165000Q-005C ASTM D4869 08/13/13 QAI Laboratories RJ3502-1 ASTM E108 09/29/14 Nemo/etc. 4S-CTR-18-003.09.18 ASTM D4798 9/21/18 4S-CTR-1 8-003.03.09.A ASTM D226/TAS 110 03/13/19 NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 4 of 9 APPROVED ASSEMBLIES: Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4"headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. (2:12 to<4:12) One or more plies of Diamond Deck with a minimum 25"head lap and a 12" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 72"minimum. Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes, &shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above)A single layer of RoofRunner shall be applied with printed side up,parallel to the eaves, overlapping each course with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and spaced 15"o.c. vertically and 12"o.c. horizontally in the field of the roll. Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with applicable Roofing Application Standards and Building Codes NOA No.: 19-0506.02 MIAMI•DAD,COUNTY Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 5 of 9 Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above)Two plies of Roofers' Select with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in a grid pattern spaced 12"o.c. in the field of the roll. (2:12 to<4:12)Two plies of Roofers' Select with a minimum 19"head lap and a 12"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in a grid pattern spaced 12"o.c. in the field of the roll. Vertical joints should be offset 72" minimum. Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with applicable Roofing Application Standards and Building Codes Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT, WinterGuard Granular,WinterGuard Sand,MetaLayment or Black Diamond Base Sheet self- adhering membrane adhered to the anchor sheet with a minimum 3"headlap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped,then anchor sheet must also be strapped. Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes, &shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 6 of 9 Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(5): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One ply of ASTM D 226 Type I1 organic felt or All Weather/Empire Base mechanically attached with a minimum 4" side lap and a minimum 6"end lap.Anchor sheet shall be applied at a right angle (900)to the slope of the deck with approved annular ring shank nails and tin caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll of the base sheet. Ply Sheet: (Optional) One or more plies of an ASTM D226 ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or Flintlastic GTA torch applied to the preceding sheet or Flintlastic SA Cap, self-adhering membranes adhered to the preceding sheet with a minimum 4" side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped,then anchor sheet and ply sheet must also be strapped. When used in Tile roof systems the cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum of 12"o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Surfacing: •Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof tile system mechanically fastened as specified in their current NOA. •Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof tile system adhered as specified in their current NOA using any foam adhesive listed and having a current tile adhesive NOA approval. Must comply with appropriate Roofing Application Standard RAS 118, RAS 119, RAS 120 and applicable Building Codes. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 7 of 9 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular, WinterGuard Sand, DiamondDeck, MetaLayment or Black Diamond Base Sheet as a cap membrane shall be acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. CertainTeed underlayment roofing systems utilizing RoofRunner or Roofers' Select shall be acceptable for use in asphaltic shingles. 3. CertainTeed underlayment roofing systems utilizing Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof tile systems as specified in the surfacing option of the approved assemblies. 4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with applicable Building Code. 5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities. 6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap, MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof for longer than 180 days of application. RoofRunner and Roofers' Select shall not be left exposed as a temporary roof for longer than 30 days after application. 8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or Miami-Dade County Product Control for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance, and fire testing results. 9. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 10. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 11. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. NOA No.: 19-0506.02 r�iar pj=jEjpj Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 8 of 9 LIMITATIONS: 13. The maximum roof slope for use as roof tile underlayment in direct-to-deck tile assemblies shall be as follows. Use of loading boards or batten strips is required on roof slopes greater than that reported in the Table below to prevent slippage. TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE ASSEMBLIES Underlayment Tile Profile Staging Method Maximum Slope Flintlastic GMS Flat/Lugged Max. 10-tile stack 4:12 Flintlastic GTA Flat/Lugged Max. 10-tile stack 6:12 Flat Max. 6-tile stack(4 over 6:12 Flintlastic SA 2) Cap Lugged Max. 6-tile stack(4 over 5:12 gg 2) END OF THIS ACCEPTANCE NOA No.: 19-0506.02 r�iar�i•oaoE[auNnr Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 9 of 9