Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HRIBAR RESIDENCE Builder Name: Street: LOT #4 LAS TORTUGAS Permit Office: ST LUCIE COUNTY City, State, Zip: ST LUCIE , FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or e)dsting New (From Plans) 9. Wall Types (5348.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=5.4 4692.30 ft2 b. Concrete Block - Ext Insul, Adjacent R=5.4 376.00 ft2 3. Number of units, if multiple family 1 c. Frame -Wood, Exterior R=19.0 280.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (4408.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 4408.00 ft2 6. Conditioned floor area above grade (ft2) 4408 b. N/A R= ft2 Conditioned Boor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (1000.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 1 CLST 6 175 a. U-Factor. Sgl, U=0.65 1000.70 if b. Sup: Attic, Ret: Attic, AH: AHU 2 CLST 6 150 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 42.0 SEER:16.00 b. Central Unit 35.2 SEER:16.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heal 27.0 COP:1.00 SHGC: b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 6.448 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Natural Gas Cap: 50 gallons 8. Floor Types (4408.0 sqft.) Insulation Area EF. 0.600 a. Raised Floor R=19.0 3928.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 480.00 ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.227 Total Proposed Modified Loads: 153.53 PASS Total Baseline Loads: 154.76 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this�Y OFTHES74TA Code. calculation indicates compliance with the Florida Energy Code. mu, x :. -'••Y : s O PREPARED BY: 1 `1 9�\'J Before construction is completed DATE: 5-8-2020 this building will be inspected for compliance with Section 553.908 c > . a I hereby certify that this building, as designed, is in compliance Florida Statutes. tl, with the Florida Energy Code. G'0 WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, 2 tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HRIBAR RESIDENCE Bedrooms: 3 Address Type: Street Address .Building Type: User Conditioned Area: 4408 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT #4 LAS TORTUGA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: ST LUCIE, Family Type: Single-family FL, New/Ewstmg: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2464 23680 2 AHU 2 1944 18137 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 KITCHEN 238 1666 Yes 0 1 Yes Yes Yes 2 CABANA 49 343 No 0 1 Yes Yes Yes 3 ELEVATOR 1ST FL 30 210 No 0 1 No Yes Yes 4 UTILITY CLST1 65 455 No 0 1 Yes Yes Yes 5 STAIR WELL 132 924 No 0 1 Yes Yes Yes 6 FOYER 204 1428 No 0 1 Yes Yes Yes 7 GATHERING ROO 308 2960 No 0 1 Yes Yes Yes 8 STAIR 1 2ND FLR 35 350 No 0 1 No Yes Yes 9 LIVING ROOM 377 4524 No 0 1 Yes Yes Yes 10 BACK HALL 36 360 No 0 1 Yes Yes Yes 11 STAIR 2 UP 40 400 No 0 1 Yes Yes Yes 12 ELEV 2ND FLR 24 240 No 0 1 No Yes Yes 13 LAUNDRY 87 870 No 0 1 Yes Yes Yes 14 PANTRY 87 870 No 0 1 Yes Yes Yes 15 AHU 1 CLST 15 150 No 0 1 No Yes Yes 16 DINING 280 3360 No 0 1 Yes Yes Yes 17 ENTRY HALL 147 1470 No 0 1 Yes Yes Yes 18 OFFICE 262 2620 No 0 1 Yes Yes Yes 19 POWDER RM 48 480 No 0 1 Yes Yes Yes 20 OWNERSWIC 140 1302 No 0 1 Yes Yes Yes 21 BEDROOM 2 233 2166.9 No 0 1 1 Yes Yes Yes 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated ` 22 AHU 2 CLST 27 251.1 No 0 1 No Yes Yes 23 BEDROOM 3 206 1915.8 No 0 1 1 Yes Yes Yes 24 WIC 25 232.5 No 0 1 No Yes Yes 25 BATH 3 75 697.5 No 0 1 Yes Yes Yes 26 HALLWAY 288 2678.4 No 0 1 Yes Yes Yes 27 STAIR 1 3RD FLR 170 1190 No 0 1 Yes Yes Yes 28 OWNERS BATH 141 1281.3 No 0 1 Yes Yes Yes 29 WIC 48 446.4 No 0 1 No Yes Yes 30 BATH 2 72 669.6 No 0 1 Yes Yes Yes 31 OWNERS BEDRO 385 3965.5 No 0 1 1 Yes Yes Yes 32 ELEV 3RD FLR 30 300 No 0 1 No Yes Yes 33 STAIR 2 3RD FLR 80 800 No 0 1 Yes Yes Yes 34 OWNERS TOILET 24 240 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor KITCHEN __ __ 238 ft' 19 1 0 0 2 Slab -On -Grade Edge Insulation CABANA 7 ft 0 49 ft' ____ 1 0 0 3 Slab -On -Grade Edge Insulation ELEVATOR 1ST 1 ft 0 30 ft' -_ 1 0 0 4 Slab -On -Grade Edge Insulation UTILITY CLST 1 18 It 0 65 ft' ---- 1 0 0 5 Slab -On -Grade Edge Insulation STAIR WELL 2 18 It 0 132 ft- ---- 1 0 0 6 Slab -On -Grade Edge Insulation FOYER 42 It 0 204 ft' ____ 1 0 0 7 Raised Floor GATHERING RO ---- -- 308 ft' 19 1 0 0 8 Raised Floor STAIR 1 2ND FL __ __ 35 ft' 19 1 0 0 9 Raised Floor LIVING ROOM ___ __ 377 ft- 19 1 0 0 10Raised Floor BACK HALL ____ ____ 36 ft' 19 1 0 0 11Raised Floor STAIR 2 UP ---- ___ 40 fl' 19 1 0 0 12Raised Floor ELEV 2ND FLR __ __ 24 ft- 19 1 0 0 13Raised Floor LAUNDRY __ __ 87 ft' 19 1 0 0 14Raised Floor PANTRY __ __ 87 ft- 19 1 0 0 15Raised Floor AHU 1 CLST ____ __ 15 ft- 19 1 0 0 16Raised Floor DINING ____ ____ I 280 W 19 1 0 0 17Raised Floor ENTRY HALL __ ___ 147 W 19 1 0 0 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 3 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 18Raised Floor OFFICE ____ ____ 262 ft2 1 19 1 0 0 19Raised Floor POWDER RM ____ ____ 48 ft2 19 1 0 0 20Raised Floor OWNERS WIC _-__ ___- 140 ft2 19 1 0 0 21Raised Floor BEDROOM 2 __ __ 233 ft2 19 1 0 0 22Raised Floor AHU 2 CLST __ __ 27 ft2 19 1 0 0 23Raised Floor BEDROOM 3 __ __ 206It' 19 1 0 0 24Raised Floor WIC 3 ___ ____ 25 ft' 19 1 0 0 25Raised Floor BATH 3 ____ ____ 75 ft2 19 1 0 0 26Raised Floor HALLWAY ___ __ 288 ft2 19 1 0 0 27Raised Floor STAIR 1 3RD FL __ — 170 ft2 19 1 0 0 28Raised Floor OWNERS BATH __ __ 141 ft2 19 1 0 0 29Raised Floor WIC 2 ___- ___ 48 ft2 19 1 0 0 30Raised Floor BATH 2 __-_ ____ 72 ft2 19 1 0 0 31 Raised Floor OWNERS BEDR ___ ____ 385 ft2 19 1 0 0 32Raised Floor ELEV 3RD FLR __-_ __ 30 ft2 19 1 0 0 33Raised Floor STAIR 2 3RD FL __ __ 80 ft2 19 1 0 0 34Raised Floor OWNERSTOILE __ __ 24 ft' 19 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 4775 ft' 0 ft2 Medium N 0.3 No 0.9 No 20 22.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 4408 ft2 N N 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN 0 Blown 238 W 0.1 Wood 2 Under Attic(Unvented) CABANA 0 Blown 49 ft' 0.1 Wood _ 3 Under Attic(Umented) ELEVATOR IST 0 Blown 30 ft' 0.1 Wood 4 Under Attic(Umented) UTILITY CLSTI 0 Blown 65 ft' 0.1 Wood 5 Under Attic(Unvented) STAIRWELL2 0 Blown 132 ft' 0.1 Wood 6 Under Altic(Urnented) FOYER 0 Blown 204 ft' 0.1 Wood 7 Under Attic(Unvented) GATHERING RO 0 Blown 308 ft' 0.1 Wood 8 Under Attic (Umented) STAIR 1 2ND FL 0 Blown 35 fN 0.1 Wood 9 Under Attic(Unvented) LIVING ROOM 0 Blown 377 ft' 0.1 Wood _ 10 Under Attic (Unvented) BACK HALL 0 Blown 36 M 0.1 Wood 11 Under Attic (Umented) STAIR 2 UP 0 Blown 40 ft' 0.1 Wood 12 Under Attic (Unvented) ELEV 2ND FLR 0 Blown 24 ft' 0.1 Wood 13 Under Attic (Unvented) LAUNDRY 0 Blown 87 IV 0.1 Wood 14 Under Attic(Unvented) PANTRY 0 Blown 87 ft' 0.1 Wood 15 Under Attic (Unvented) AHU 1 CLST 0 Blown 15 ft' 0.1 Wood _ 16 Under Attic(Unvented) DINING 0 Blown 280 ft' 0.1 Wood 17 Under Attic (Unvented) ENTRY HALL 0 Blown 147 ft' 0.1 Wood _ 18 Under Attic(Unvented) OFFICE 0 Blown 262 ft' 0.1 Wood _ 19 Under Attic(Unvented) POWDER RM 0 Blown 48 ft' 0.1 Wood _ 20 Under Attic(Unwnted) OWNERS WIC 0 Blown 140 ft' 0.1 Woad 21 Under Attic (Unvented) BEDROOM 0 Blown 233 ft' 0.1 Wood 22 Under Attic (Unvented) AHU2CLST 0 Blown 27 ft' 0.1 Wood _ 23 Under Attic (Unvented) BEDROOM 3 0 Blown 206 ft' 0.1 Wood 24 Under Attic(Unvented) WIC 0 Blown 25 ft' 0.1 Wood _ 25 Under Attic (Unvented) BATH 0 Blown 75 ft' 0.1 Wood _ 26 Under Attic (Unvented) HALLWAY 0 Blown 288 ft' 0.1 Wood _ 27 Under Attic (Unvented) STAIR 1 3RD FL 0 Blown 170 ft' 0.1 Wood 28 Under Attic (Unvented) OWNERS BATH 0 Blown 141 ft' 0.1 Wood _ 29 Under Attic (Unvented) WIC 2 0 Blown 48 ft' 0.1 Wood 30 Under Attic (Unvented) BATH 2 0 Blown 72 ft' 0.1 Wood _ 31 Under Attic (Unvented) OWNERS BEDR 0 Blown 385 ft' 0.1 Wood _ 32 Under Attic (Unvented) ELEV 3RD FLR 0 Blown 30 ft' 0.1 Wood 33 Under Attic (Unvented) STAIR 2 3RD FL 0 Blown 80 ft' 0.1 Wood 34 Under Attic(Unvented) OWNERS TOILE 0 Blown 24 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 E Exterior Concrete Block - Ext Insul KITCHEN 5.4 15 0 10 0 150.0 ft' 0 0 0.3 0 2 W Exterior Concrete Block - Ext Insul CABANA 5.4 6 3 9 0 56.3 ft' 0 0 0.3 0 3 E Garage Concrete Block - 6d Insul CABANA 5.4 2 0 8 0 16 0 ft' 0 0 0.3 0 _ 4 N Garage Concrete Block - Ext Insul CABANA 5.4 7 0 8 0 56.0 ft' 0 0 0.3 0 _ 5 N Exterior Concrete Block - Ext InstUTILITY CLS 5.4 7 0 8 0 56.0 ft' 0 0 0.3 0 6 E Exterior Concrete Block - Ext InsLUTILITY CLS 5.4 11 0 8 0 88.0 fl' 0 0 0.3 0 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 10 FA WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 7 E Exterior Concrete Block - Ext InsBTAIR WELL 5.4 6 0 8 0 48.0 ft2 0 0 0.3 0 8 W Exterior Concrete Block- Ext Ins6rrAIR WELL 5.4 10 8 9 0 96.0 ft2 0 0 0.3 0 _ 9 S Garage Concrete Block- Ext Instil WELL 5.4 15 0 8 0 120.0 ft2 0 0 0.3 0 10 N Garage Concrete Block - Ext InsHrAIR WELL 6.4 5 0 8 0 40.0 ft2 0 0 0.3 0 _ 11 E Exterior Concrete Block - Ext Insul FOYER 5.4 9 0 8 0 72.0 ft2 0 0 0.3 0 _ 12 S Exterior Concrete Block - Ext Insul FOYER 5.4 23 0 9 0 207.0 ft2 0 0 0.3 0 _ 13 W Exterior Concrete Block - Ext Insul FOYER 5.4 6 0 9 0 54.0 ft- 0 0 0.3 0 _ 14 N Garage Concrete Block - 6d Insul FOYER 5.4 18 0 8 0 144.0 ft2 0 0 0.3 0 _ 15 W Exterior Concrete Block - Ext InsGATHERING 5.4 22 0 10 0 220.0 ft2 0 0 0.3 0 16 N Exterior Concrete Block - Ext InsdIIVING ROO 5.4 16 0 12 0 192.0 ft2 0 0 0.3 0 _ 17 S Exterior Concrete Block - Ext InsdIIVING ROO 5.4 15 0 12 0 180.0 ft2 0 0 0.3 0 18 SW Exterior Concrete Block- Ext lnsdIIVING ROO 5.4 4 3 12 0 51.0 ft2 0 0 0.3 0 _ 19 W Exterior Concrete Block- Ext InsdIIVING ROO 5.4 13 0 12 0 156.0 ft2 0 0 0.3 0 20 NW Exterior Concrete Block - Ext InsdIIVING ROO 5.4 4 3 12 0 51.0 ft2 0 0 0.3 0 21 E Exterior Concrete Block - Ext InsLEACK HALL 5.4 4 0 10 0 40.0 ft2 0 0 0.3 0 22 N Exterior Concrete Block - Ext InsLGTAIR 2 UP 5.4 8 0 10 0 80.0 ft2 0 0 0.3 0 23 N Exterior Frame -Wood LAUNDRY 19 3 0 10 0 30.0 ft2 0 0.1 0.3 0 24 E Exterior Frame -Wood LAUNDRY 19 8 0 10 0 80.0 ft2 0 0.1 0.3 0 25 S Exterior Frame -Wood LAUNDRY 19 3 0 10 0 30.0 ft2 0 0.1 0.3 0 _ 26 N Exterior Frame - Wood PANTRY 19 3 0 10 0 30.0 ft2 0 0.1 0.3 0 27 E Exterior Frame -Wood PANTRY 19 8 0 10 0 80.0 ft2 0 0.1 0.3 0 28 S Exterior Frame -Wood PANTRY 19 3 0 10 0 30.0 ft2 0 0.1 0.3 0 29 N Exterior Concrete Block- Ext Insul DINING 5.4 9 0 12 0 108.0 ft2 0 0 0.3 0 30 S Exterior Concrete Block- Ext Ins®NTRY HALL 6.4 9 0 10 0 90.0 ft2 0 0 0.3 0 _ 31 N Exterior Concrete Block - Ext Insul OFFICE 5.4 15 0 10 0 150.0 ft2 0 0 0.3 0 32 S Exterior Concrete Block - Ext Insul OFFICE 5.4 16 0 10 0 160.0 ft2 0 0 0.3 0 33 W Exterior Concrete Block -Ext Insul OFFICE 5.4 15 0 10 0 150.0 ft2 0 0 0.3 0 34 S Exterior Concrete Block- Ext InsdPOWDER R 5.4 6 0 10 0 60.0 ft2 0 0 0.3 0 35 W Exterior Concrete Block- Ext InsOWNERS WI 5.4 4 0 9 4 37.3 ft2 0 0 0.3 0 _ 36 W Exterior Concrete Block - Ext InsiBEDROOM 2 5.4 13 0 9 4 121.3 ft2 0 0 0.3 0 _ 37 N Exterior Concrete Block - Ext InstHEDROOM 3 5.4 16 0 9 4 149.3 ft2 0 0 0.3 0 38 S Exterior Concrete Block - Ext InstEEDROOM 3 5.4 14 0 9 4 130.7 ft2 0 0 0.3 0 _ 39 W Exterior Concrete Block - Ext Insd1EDROOM 3 5.4 14 0 9 4 130.7 ft2 0 0 0.3 0 _ 40 S Exterior Concrete Block - Ext Insul BATH 3 5.4 10 0 9 4 93.3 ft2 0 0 0.3 0 41 E Exterior Concrete Block - Ext InsulHALLWAY 5.4 35 0 9 4 326.7 ft2 0 0 0.3 0 42 E Exterior Concrete Block - Ext In56ITAIR 1 3RD 5.4 10 0 9 4 93.3 ft2 0 0 0.3 0 _ 43 S Exterior Concrete Block - Ext InsffrAIR 1 3RD 5.4 17 0 9 4 158.7 ft2 0 0 0.3 0 _ 44 N Exterior Concrete Block - Ext InsOW NERS BA 5.4 11 0 9 4 102.7 ft2 0 0 0.3 0 45 W Exterior Concrete Block - Ext Insul BATH 2 5.4 6 0 9 4 56.0 ft2 0 0 0.3 0 46 N Exterior Concrete Block - Ext InsQWNERS BE 5.4 14 0 10 4 144.7 ft2 0 0 0.3 0 47 S Exterior Concrete Block -Ext lnsOWNERS BE 5.4 14 0 10 4 144.7 ft2 0 0 0.3 0 _48 SW Exterior Concrete Block- Ext InsOWNERS BE 5.4 5 0 10 4 51.7 ft2 0 0 0.3 0 _49 W Exterior Concrete Block- Ext InsOWNERS BE 5.4 13 0 10 4 134.3 ft2 0 0 0.3 0 5/8/2020 829 AM EnergyGaugeQD USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 6 of 10 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 50 NW Exterior Concrete Block- Ext lnsOWNERS BE 5.4 5 0 10 4 51.7 ft2 0 0 0.3 0 _ 51 N Exterior Concrete Block - Ext InsBRAIR 2 3RD 5.4 10 0 10 0 100.0 ft2 0 0 0.3 0 _ 52 E Exterior Concrete Block - E t Ins8RAIR 2 3RD 5.4 11 0 10 0 110.0 ft2 0 0 0.3 0 53 N Exterior Concrete Block -Ext InsOWNERS TO 5.4 4 0 10 0 40.0 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated FOYER None .4 6 6 8 40 ft2 I WINDOWS I Orientation shown is the entered. Pr000sed orientation. / Wall V # Ornt ID Frame Panes 1 E 1 Metal Low-E Single 2 W 2 Metal Low-E Single 3 E 7 Metal low-E Single 4 S 12 Metal Low-E Single 5 W 13 Metal Low-E Single 6 W 15 Metal Low-E Single 7 N 16 Metal Low-E Single 8 S 17 Metal Low-E Single 9 SW 18 Metal Low-E Single 10 W 19 Metal Low-E Single 11 NW 20 Metal Low-E Single 12 E 21 Metal Low-E Single 13 E 24 Metal Low-E Single 14 E 27 Metal Low-E Single 15 N 29 Metal Low-E Single 16 S 30 Metal Law-E Single 17 N 31 Metal Low-E Single 18 S 32 Metal Low-E Single 19 W 33 Metal Low-E Single 20 W 33 Metal Low-E Single 21 S 34 Metal Low-E Single 22 W 36 Metal Low-E Single 23 N 37 Metal Low-E Single 24 S 38 Metal Low-E Single 25 W 39 Metal Low-E Single 26 S 40 Metal Law-E Single 27 E 41 Metal Low-E Single 28 E 42 Metal Low-E Single 29 S 43 Metal Low-E Single 30 S 43 Metal Low-E Single NFRC Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes U-Factor SHGC 0.66 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.66 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 Overhang mp Area Depth Separatic N 20.0 ft2 2ft6 in 12ft0 in N 4.0 ft2 2it6in 24ft0 in N 8.0 ft2 2ft6 in 24it0 in N 12.5 ft2 2ft6in 24ft0 in N 26.8 ft2 2ft6 in 24 it in N 162.0 ft2 20 ft 0 in 12 ft0 in N 21.0 ft2 2ft6in 12ft0in N 72.0 ft2 18 It Din 12ft0in N 25.5 112 2it6in 12 ft0 in N 63.0 ft2 2ft6in 12ft0in N 20.4 ft2 2It6in 12 It in N 10.0 ft2 2ft6in 12ft0in N 10.0 ft2 2ft6in 12 It 0 in N 10.0 ft2 2ft6in 12 It in N 21.0 ft2 2ft6 in 12 It 0 in N 48.0 ft2 2ft6 in 12 It in N 12.5 ft2 2ft6in 12it0in N 25.0 ft2 2ft6 in 12it0 in N 64.0 ft2 2ft6 in 12ft0 in N 24.0 ft2 2ft6 in 12 ft0 in N 6.3 ft2 2ft6 in 12 ft0 in N 30.0 ft2 2ft6 in 1ft0 in N 12.5 112 2ft6 in 1ft0 in N 25.0 ft2 2ft6in 1ft0 in N 30.0 ft2 2ft6in 1ft0 in N 6.3 ft2 2it6in 1ft0in N 40.0 ft2 2ft6 in 1ft0 in N 12.5 112 2ft6 in 1ft0 in N 12.5 ft2 2ft6 in 1ft0in N 12.5 112 2ft6 in 1ft0 in Int Shade Screening None None None None None None None None None None Drapes/blinds Exterior Drapes/blinds Exterior Drapes/blinds Exterior Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior None None None None None None None None None None Drapes/blinds Exteriors Drapes/blinds Exterior 5 Drapes/blinds Exteriors Drapes blinds Exterior None None None None Drapes/blinds Exterior Drapes/blinds Exterior Drapes blinds Exterior None None None None Drapes/blinds Exterior Drapes/blinds Exterior Drapes/blinds Exterior 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 31 N 44 Metal Low-E Single Yes 0.65 0.25 N 6.3 ft' 2 ft 6 in 1 ft 0 in None None _ 32 N 44 Metal Low-E Single Yes 0.65 0.25 N 25.0 ft' 2 ft 6 in 1 ft 0 in None None _ 33 W 45 Metal Low-E Single Yes 0.65 0.25 N 7.5 ft' 2 ft 6 in 1 ft 0 in None None 34 N 46 Metal Low-E Single Yes 0.65 0.25 N 6.3 ft' 2 ft 6 in 1 ft 0 in None None 35 N 46 Metal Low-E Single Yes 0.65 0.25 N 6.3 ft' 2 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 36 S 47 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft' 2 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 37 SW 48 Metal Low-E Single Yes 0.65 0.25 N 17.0 ft' 2 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 38 W 49 Metal Low-E Single Yes 0.65 0.25 N 54.0 ft' 2 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 39 NW 50 Metal Low-E Single Yes 0.65 0.25 N 17.0 ft' 2 ft 6 in 1 ft 0 in Drapestblinds Exterior 5 40 N 53 Metal Low-E Single Yes 0.65 0.25 N 6.3 ft' 2 ft 6 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1200 ft' 1200 ft- 34 ft 8 ft 5.4 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000422 4878.6 267.83 503.7 .1565 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts _ 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 27 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 35.2 kBlu/hr 1056 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas None Garage 0.6 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 8 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS / — Supply---- — Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 18 ft2 Prop. Leak Free AHU 1 CLS — cfm 73.9 cfm 0.03 0.50 1 1 2 Attic 6 150 fP Attic 15 ft2 Prop. Leak Free AHU 2 CLS —cfm 58.3 cfm 0.03 0.50 2 2 TEMPERATURES Programable[[Thermostat: CFans: Ian[�jjN eb [ ]] Aprrjeiling tX �C [�j rjX'j NovfjX,j Dee Heating [X] Jan Feb [X] Mar JuMay n t Jul j Aug t i $eP Venting [[ 11 Jan l l 1 Feb l 1X11 Mar Apr [ May Jun I Jul I Aug l 1 Sep Oct �C] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 CABANA Default(8 lbs/sq.ft. ft2 ft 0.3 ELEVATOR 1ST FL Default(8 lbs/sq.ft. ft2 It 0.3 UTILITY CLST 1 Default(8 lbs/sq.ft. ft2 ft 0.3 STAIRWELL2 Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(81bs/sq.ft. ft2 ft 0.3 GATHERING ROO Default(B lbs/sq.ft. ft2 ft 0.3 STAIR 1 2ND FLR Default(8 lbs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(B lbs/sq.ft. ft2 It 0.3 BACK HALL Default(8 lbs/sq.ft. ft2 ft 0.3 STAIR 2 UP Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEV 2ND FLR Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 PANTRY Default(8 lbs/sq.ft. ft2 ft 0.3 AHU 1 CLST Default(8 lbs/sq.ft. fill ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY HALL Default(81bs/sq.ft. ft2 ft 0.3 OFFICE Default(B lbs/sq.ft. ft2 ft 0.3 POWDER RM Default(8 lbs/sq.ft. ft2 ft 0.3 OWNERSWIC Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. 112 ft 0.3 AHU 2 CLST Default(8 lbs/sq.ft. ft2 If 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 9 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 It 0.3 HALLWAY Default(8 lbs/sq.ft. ft2 It 0.3 STAIR 1 3RD FLR Default(8 lbs/sq.ft. ft' It 0.3 OWNERS BATH Default(8 lbs/sq.ft. ft2 It 0.3 WIC2 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 OWNERS BEDRO Default(8 lbs/sq.ft. ft' ft 0.3 ELEV 3RD FLR Default(8 Ibs/sq.ft. ft2 It 0.3 STAIR 2 3RD FLR Default(8 lbs/s.ft. ft2 It 0.3 OWNERS TOILET i r 5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 10 of 10 Residential Standard Calculation 926/1997 Hribar Residence Version 2011 L STEP 1 Article 220.42 & 220.52 ,art r±j 440B General Lighting load 6 Small Appliance 1 Laundry circuit Gen. Lgt, Shin App.& Laun. Load STEP 2 Article 220.50 & 220.51 Rl A/C Condenser & Fixed Electric Space Heating AKn i.{ VA AHU 1 rl�VA AHU2acVA AHU 3ae ea p�VA AHU4Arcx [� VA AHU5 LJ STEP 3 Article 220.53 asmvA J�J 1 Water Heater 1MOVA 3 Refrigerator 6mv! [,V Freezer 1.010VA 1-1 1 Dishwasher MVA '.{ 1 Disposal "VA i+l 1 R / Hood 1.630VA I-1 1 Microwave ❑ a%0VA 1-1 Microwave 170VA .V.{ Mini Refdg ❑ COVA 1L1 Wine Clr ❑ %MVA 1.1 Insta Hot umVA �{ Ironing Center ❑ ,e<n l..{ Jacuzzi Tub ❑ +ap {v,j Sprinkler Pump ❑ 7ap [v] Well Pump sww I V.{ Fountain Pump an Elevator Pool Equip. Panel ❑ GATES ❑ Other load STEP 4 Article 220.54 Electric Clothes Dryers STEP 5 Article 220.55 Electric Ranges or Number of appliances 2 13,224 VA 9,000 VA 1,500 VA 23,724 VA 3,000 VA @ 100%= 20,724 VA @ 35% _ VA @ 25% _ QTY 11,600 VA 1 1 r-1 11,600 VA IF-1-1 VA Qa [VJ VA QV LVf VA Qtr u 4,500 VA Comfort Control Services 1507 SW Biltmore St . PSL, FL, 34983 Telephone & Fax 10=191525 3,000 VA 7,253 VA VA General Lighting Demand Load Total 2 Heating Load 23,200 VA CU Load VA Greater of Heat @ 100 % vs.A/C @ 100 % Appliance Demand Load 4,200 VA Dryer Demand Load VA 1,030 VA Range Demand Load 690 VA 400 VA Service Demand 1,630 VA VA Demand Load VA VA Neutral Demand VA VA Min.Service Req. VA 1, 127 VA Min. Feeder size 1,127 VA Min. Neutral size VA Eq. Girding Cord. VA ❑ 5,175 VA 100 % Demand VA No Demand VA No Demand Total Appliance Load 19,879 VA 4 or more demand @ 75% plus 100% demand loads 5,000 VA Col C demand 11000 Cooktop Col B demand ❑ check Bmc for Gas Range Cooktop 8,000 W Col B demand Oven(s) 8,000 W Col B demand Oven(s) Col B demand Number of appliances 2 Dem. Factor 65% Cooktop & Oven Demand Load 10,400 W nuous 0 ...... Spa heater 11 kVA , , , , , 0 0 0 0 0 10,253 VA 23,200 VA 16,203 VA 5,000 VA 10,400 VA 65,056 VA 271 A 114 A 300 A 250 2 4 Copper 16,203 VA 15p �1❑ 240v <.W r.f ❑ 240v etet J.l❑ 240V akR I.f ❑ 240V eektt ��{❑ 240V wkn J�,I ❑ 240V elect "� ❑ 240v ,eied ❑ 240v 0.0 Motor Neutral Load Max.Unbalanced Neutral Load 1 Pool Panel Feeder Calculation (see Note) A B IN Continuous Non-confnuous Continuous Motors 2,875 ...... 7438 1438 0 Motors Motors Non -conti 240V eeW [.I ❑ 240V 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HRIBAR RESIDENCE Builder Name: Street: LOT *4 LAS TORTUGAS Permit Office: ST LUCIE COUNTY City, State, Zip: ST LUCIE, FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY W x Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier In any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls Thejunction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shallbe sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be In contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavites shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed In the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neally to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs, insulated. Electricat/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/3/2019 3:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 77.2 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 4408 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 1000.7 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 19.0 9c. 10A1. 19.0 10A2. 5.4 10131. 10132. 5.4 11a. 0.0 11 b. 11 c. 11d. No 14. Heating system: Capacity 54.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE - f) Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF 0.60 c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit 0 Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Z Address of New Home: LOT #4 LAS TORTUGAS City/FL Zip: ST LUCIE. FL 10/3/2019 3:03:44 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1