HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HRIBAR RESIDENCE
Builder Name:
Street: LOT #4 LAS TORTUGAS
Permit Office: ST LUCIE COUNTY
City, State, Zip: ST LUCIE , FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or e)dsting New (From Plans)
9. Wall Types (5348.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Ext Insul, Exterior
R=5.4 4692.30 ft2
b. Concrete Block - Ext Insul, Adjacent
R=5.4 376.00 ft2
3. Number of units, if multiple family 1
c. Frame -Wood, Exterior
R=19.0 280.00 ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (4408.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 4408.00 ft2
6. Conditioned floor area above grade (ft2) 4408
b. N/A
R= ft2
Conditioned Boor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (1000.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU 1 CLST
6 175
a. U-Factor. Sgl, U=0.65 1000.70 if
b. Sup: Attic, Ret: Attic, AH: AHU 2 CLST
6 150
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
42.0 SEER:16.00
b. Central Unit
35.2 SEER:16.00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heal
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 6.448 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Natural Gas
Cap: 50 gallons
8. Floor Types (4408.0 sqft.) Insulation Area
EF. 0.600
a. Raised Floor R=19.0 3928.00 ft2
b. Conservation features
b. Slab -On -Grade Edge Insulation R=0.0 480.00 ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.227 Total Proposed Modified Loads: 153.53
PASS
Total Baseline
Loads: 154.76
1 hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this�Y
OFTHES74TA
Code.
calculation indicates compliance
with the Florida Energy Code.
mu, x :. -'••Y : s O
PREPARED BY: 1 `1 9�\'J
Before construction is completed
DATE: 5-8-2020
this building will be inspected for
compliance with Section 553.908
c >
. a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
tl,
with the Florida Energy Code.
G'0 WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
2 tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house.
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 10
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
HRIBAR RESIDENCE
Bedrooms:
3
Address Type:
Street Address
.Building Type:
User
Conditioned
Area:
4408
Lot#
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
LOT #4 LAS TORTUGA
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
ST LUCIE,
Family Type:
Single-family
FL,
New/Ewstmg:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design
Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
2464
23680
2
AHU 2
1944
18137
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfI ID Finished Cooled
Heated
1
KITCHEN
238
1666
Yes
0
1
Yes
Yes
Yes
2
CABANA
49
343
No
0
1
Yes
Yes
Yes
3
ELEVATOR 1ST FL
30
210
No
0
1
No
Yes
Yes
4
UTILITY CLST1
65
455
No
0
1
Yes
Yes
Yes
5
STAIR WELL
132
924
No
0
1
Yes
Yes
Yes
6
FOYER
204
1428
No
0
1
Yes
Yes
Yes
7
GATHERING ROO
308
2960
No
0
1
Yes
Yes
Yes
8
STAIR 1 2ND FLR
35
350
No
0
1
No
Yes
Yes
9
LIVING ROOM
377
4524
No
0
1
Yes
Yes
Yes
10
BACK HALL
36
360
No
0
1
Yes
Yes
Yes
11
STAIR 2 UP
40
400
No
0
1
Yes
Yes
Yes
12
ELEV 2ND FLR
24
240
No
0
1
No
Yes
Yes
13
LAUNDRY
87
870
No
0
1
Yes
Yes
Yes
14
PANTRY
87
870
No
0
1
Yes
Yes
Yes
15
AHU 1 CLST
15
150
No
0
1
No
Yes
Yes
16
DINING
280
3360
No
0
1
Yes
Yes
Yes
17
ENTRY HALL
147
1470
No
0
1
Yes
Yes
Yes
18
OFFICE
262
2620
No
0
1
Yes
Yes
Yes
19
POWDER RM
48
480
No
0
1
Yes
Yes
Yes
20
OWNERSWIC
140
1302
No
0
1
Yes
Yes
Yes
21
BEDROOM 2
233
2166.9
No
0
1
1
Yes
Yes
Yes
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 10
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number
Name Area Volume
Kitchen Occupants
Bedrooms
Infil ID
Finished
Cooled
Heated
` 22
AHU 2 CLST 27 251.1
No
0
1
No
Yes
Yes
23
BEDROOM 3 206 1915.8
No
0
1
1
Yes
Yes
Yes
24
WIC 25 232.5
No
0
1
No
Yes
Yes
25
BATH 3 75 697.5
No
0
1
Yes
Yes
Yes
26
HALLWAY 288 2678.4
No
0
1
Yes
Yes
Yes
27
STAIR 1 3RD FLR 170 1190
No
0
1
Yes
Yes
Yes
28
OWNERS BATH 141 1281.3
No
0
1
Yes
Yes
Yes
29
WIC 48 446.4
No
0
1
No
Yes
Yes
30
BATH 2 72 669.6
No
0
1
Yes
Yes
Yes
31
OWNERS BEDRO 385 3965.5
No
0
1
1
Yes
Yes
Yes
32
ELEV 3RD FLR 30 300
No
0
1
No
Yes
Yes
33
STAIR 2 3RD FLR 80 800
No
0
1
Yes
Yes
Yes
34
OWNERS TOILET 24 240
No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Raised Floor KITCHEN
__ __
238 ft'
19
1
0
0
2 Slab -On -Grade Edge Insulation CABANA
7 ft 0
49 ft'
____
1
0
0
3 Slab -On -Grade Edge Insulation ELEVATOR 1ST
1 ft 0
30 ft'
-_
1
0
0
4 Slab -On -Grade Edge Insulation UTILITY CLST 1
18 It 0
65 ft'
----
1
0
0
5 Slab -On -Grade Edge Insulation STAIR WELL 2
18 It 0
132 ft-
----
1
0
0
6 Slab -On -Grade Edge Insulation FOYER
42 It 0
204 ft'
____
1
0
0
7 Raised Floor GATHERING RO
---- --
308 ft'
19
1
0
0
8 Raised Floor STAIR 1 2ND FL
__ __
35 ft'
19
1
0
0
9 Raised Floor LIVING ROOM
___ __
377 ft-
19
1
0
0
10Raised Floor BACK HALL
____ ____
36 ft'
19
1
0
0
11Raised Floor STAIR 2 UP
---- ___
40 fl'
19
1
0
0
12Raised Floor ELEV 2ND FLR
__ __
24 ft-
19
1
0
0
13Raised Floor LAUNDRY
__ __
87 ft'
19
1
0
0
14Raised Floor PANTRY
__ __
87 ft-
19
1
0
0
15Raised Floor AHU 1 CLST
____ __
15 ft-
19
1
0
0
16Raised Floor DINING
____ ____
I
280 W
19
1
0
0
17Raised Floor ENTRY HALL
__ ___
147 W
19
1
0
0
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 3 of 10
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
18Raised Floor
OFFICE ____
____
262 ft2
1
19
1
0
0
19Raised Floor
POWDER RM ____
____
48 ft2
19
1
0
0
20Raised Floor
OWNERS WIC _-__
___-
140 ft2
19
1
0
0
21Raised Floor
BEDROOM 2 __
__
233 ft2
19
1
0
0
22Raised Floor
AHU 2 CLST __
__
27 ft2
19
1
0
0
23Raised Floor
BEDROOM 3 __
__
206It'
19
1
0
0
24Raised Floor
WIC 3 ___
____
25 ft'
19
1
0
0
25Raised Floor
BATH 3 ____
____
75 ft2
19
1
0
0
26Raised Floor
HALLWAY ___
__
288 ft2
19
1
0
0
27Raised Floor
STAIR 1 3RD FL __
—
170 ft2
19
1
0
0
28Raised Floor
OWNERS BATH __
__
141 ft2
19
1
0
0
29Raised Floor
WIC 2 ___-
___
48 ft2
19
1
0
0
30Raised Floor
BATH 2 __-_
____
72 ft2
19
1
0
0
31 Raised Floor
OWNERS BEDR ___
____
385 ft2
19
1
0
0
32Raised Floor
ELEV 3RD FLR __-_
__
30 ft2
19
1
0
0
33Raised Floor
STAIR 2 3RD FL __
__
80 ft2
19
1
0
0
34Raised Floor
OWNERSTOILE __
__
24 ft'
19
1
0
0
ROOF
/
Roof
Gable Roof
Red
Solar
SA Emitt
Emitt
Deck
Pitch
V
# Type
Materials Area
Area Color
Barr
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Flat tile/slate 4775 ft'
0 ft2 Medium
N
0.3
No 0.9
No
20
22.6
ATTIC
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0 4408 ft2
N
N
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 10
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
KITCHEN
0
Blown
238 W
0.1
Wood
2
Under Attic(Unvented)
CABANA
0
Blown
49 ft'
0.1
Wood
_
3
Under Attic(Umented)
ELEVATOR IST
0
Blown
30 ft'
0.1
Wood
4
Under Attic(Umented)
UTILITY CLSTI
0
Blown
65 ft'
0.1
Wood
5
Under Attic(Unvented)
STAIRWELL2
0
Blown
132 ft'
0.1
Wood
6
Under Altic(Urnented)
FOYER
0
Blown
204 ft'
0.1
Wood
7
Under Attic(Unvented)
GATHERING RO
0
Blown
308 ft'
0.1
Wood
8
Under Attic (Umented)
STAIR 1 2ND FL
0
Blown
35 fN
0.1
Wood
9
Under Attic(Unvented)
LIVING ROOM
0
Blown
377 ft'
0.1
Wood
_
10
Under Attic (Unvented)
BACK HALL
0
Blown
36 M
0.1
Wood
11
Under Attic (Umented)
STAIR 2 UP
0
Blown
40 ft'
0.1
Wood
12
Under Attic (Unvented)
ELEV 2ND FLR
0
Blown
24 ft'
0.1
Wood
13
Under Attic (Unvented)
LAUNDRY
0
Blown
87 IV
0.1
Wood
14
Under Attic(Unvented)
PANTRY
0
Blown
87 ft'
0.1
Wood
15
Under Attic (Unvented)
AHU 1 CLST
0
Blown
15 ft'
0.1
Wood
_
16
Under Attic(Unvented)
DINING
0
Blown
280 ft'
0.1
Wood
17
Under Attic (Unvented)
ENTRY HALL
0
Blown
147 ft'
0.1
Wood
_
18
Under Attic(Unvented)
OFFICE
0
Blown
262 ft'
0.1
Wood
_
19
Under Attic(Unvented)
POWDER RM
0
Blown
48 ft'
0.1
Wood
_
20
Under Attic(Unwnted)
OWNERS WIC
0
Blown
140 ft'
0.1
Woad
21
Under Attic (Unvented)
BEDROOM
0
Blown
233 ft'
0.1
Wood
22
Under Attic (Unvented)
AHU2CLST
0
Blown
27 ft'
0.1
Wood
_
23
Under Attic (Unvented)
BEDROOM 3
0
Blown
206 ft'
0.1
Wood
24
Under Attic(Unvented)
WIC
0
Blown
25 ft'
0.1
Wood
_
25
Under Attic (Unvented)
BATH
0
Blown
75 ft'
0.1
Wood
_
26
Under Attic (Unvented)
HALLWAY
0
Blown
288 ft'
0.1
Wood
_
27
Under Attic (Unvented)
STAIR 1 3RD FL
0
Blown
170 ft'
0.1
Wood
28
Under Attic (Unvented)
OWNERS BATH
0
Blown
141 ft'
0.1
Wood
_
29
Under Attic (Unvented)
WIC 2
0
Blown
48 ft'
0.1
Wood
30
Under Attic (Unvented)
BATH 2
0
Blown
72 ft'
0.1
Wood
_
31
Under Attic (Unvented)
OWNERS BEDR
0
Blown
385 ft'
0.1
Wood
_
32
Under Attic (Unvented)
ELEV 3RD FLR
0
Blown
30 ft'
0.1
Wood
33
Under Attic (Unvented)
STAIR 2 3RD FL
0
Blown
80 ft'
0.1
Wood
34
Under Attic(Unvented)
OWNERS TOILE
0
Blown
24 ft'
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Space
_ 1
E
Exterior Concrete Block -
Ext Insul KITCHEN
5.4 15
0 10
0
150.0 ft'
0 0
0.3
0
2
W
Exterior Concrete Block -
Ext Insul CABANA
5.4 6
3 9
0
56.3 ft'
0 0
0.3
0
3
E
Garage Concrete Block -
6d Insul CABANA
5.4 2
0 8
0
16 0 ft'
0 0
0.3
0
_ 4
N
Garage Concrete Block -
Ext Insul CABANA
5.4 7
0 8
0
56.0 ft'
0 0
0.3
0
_ 5
N
Exterior Concrete Block -
Ext InstUTILITY CLS
5.4 7
0 8
0
56.0 ft'
0 0
0.3
0
6
E
Exterior Concrete Block -
Ext InsLUTILITY CLS
5.4 11
0 8
0
88.0 fl'
0 0
0.3
0
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 10
FA
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
7
E
Exterior
Concrete Block - Ext InsBTAIR WELL
5.4
6
0 8
0
48.0 ft2
0
0
0.3
0
8
W
Exterior
Concrete Block- Ext Ins6rrAIR WELL
5.4
10
8 9
0
96.0 ft2
0
0
0.3
0
_ 9
S
Garage
Concrete Block- Ext Instil WELL
5.4
15
0 8
0
120.0 ft2
0
0
0.3
0
10
N
Garage
Concrete Block - Ext InsHrAIR WELL
6.4
5
0 8
0
40.0 ft2
0
0
0.3
0
_ 11
E
Exterior
Concrete Block - Ext Insul FOYER
5.4
9
0 8
0
72.0 ft2
0
0
0.3
0
_ 12
S
Exterior
Concrete Block - Ext Insul FOYER
5.4
23
0 9
0
207.0 ft2
0
0
0.3
0
_ 13
W
Exterior
Concrete Block - Ext Insul FOYER
5.4
6
0 9
0
54.0 ft-
0
0
0.3
0
_ 14
N
Garage
Concrete Block - 6d Insul FOYER
5.4
18
0 8
0
144.0 ft2
0
0
0.3
0
_ 15
W
Exterior
Concrete Block - Ext InsGATHERING
5.4
22
0 10
0
220.0 ft2
0
0
0.3
0
16
N
Exterior
Concrete Block - Ext InsdIIVING ROO
5.4
16
0 12
0
192.0 ft2
0
0
0.3
0
_ 17
S
Exterior
Concrete Block - Ext InsdIIVING ROO
5.4
15
0 12
0
180.0 ft2
0
0
0.3
0
18
SW
Exterior
Concrete Block- Ext lnsdIIVING ROO
5.4
4
3 12
0
51.0 ft2
0
0
0.3
0
_ 19
W
Exterior
Concrete Block- Ext InsdIIVING ROO
5.4
13
0 12
0
156.0 ft2
0
0
0.3
0
20
NW
Exterior
Concrete Block - Ext InsdIIVING ROO
5.4
4
3 12
0
51.0 ft2
0
0
0.3
0
21
E
Exterior
Concrete Block - Ext InsLEACK HALL
5.4
4
0 10
0
40.0 ft2
0
0
0.3
0
22
N
Exterior
Concrete Block - Ext InsLGTAIR 2 UP
5.4
8
0 10
0
80.0 ft2
0
0
0.3
0
23
N
Exterior
Frame -Wood LAUNDRY
19
3
0 10
0
30.0 ft2
0
0.1
0.3
0
24
E
Exterior
Frame -Wood LAUNDRY
19
8
0 10
0
80.0 ft2
0
0.1
0.3
0
25
S
Exterior
Frame -Wood LAUNDRY
19
3
0 10
0
30.0 ft2
0
0.1
0.3
0
_ 26
N
Exterior
Frame - Wood PANTRY
19
3
0 10
0
30.0 ft2
0
0.1
0.3
0
27
E
Exterior
Frame -Wood PANTRY
19
8
0 10
0
80.0 ft2
0
0.1
0.3
0
28
S
Exterior
Frame -Wood PANTRY
19
3
0 10
0
30.0 ft2
0
0.1
0.3
0
29
N
Exterior
Concrete Block- Ext Insul DINING
5.4
9
0 12
0
108.0 ft2
0
0
0.3
0
30
S
Exterior
Concrete Block- Ext Ins®NTRY HALL
6.4
9
0 10
0
90.0 ft2
0
0
0.3
0
_ 31
N
Exterior
Concrete Block - Ext Insul OFFICE
5.4
15
0 10
0
150.0 ft2
0
0
0.3
0
32
S
Exterior
Concrete Block - Ext Insul OFFICE
5.4
16
0 10
0
160.0 ft2
0
0
0.3
0
33
W
Exterior
Concrete Block -Ext Insul OFFICE
5.4
15
0 10
0
150.0 ft2
0
0
0.3
0
34
S
Exterior
Concrete Block- Ext InsdPOWDER R
5.4
6
0 10
0
60.0 ft2
0
0
0.3
0
35
W
Exterior
Concrete Block- Ext InsOWNERS WI
5.4
4
0 9
4
37.3 ft2
0
0
0.3
0
_ 36
W
Exterior
Concrete Block - Ext InsiBEDROOM 2
5.4
13
0 9
4
121.3 ft2
0
0
0.3
0
_ 37
N
Exterior
Concrete Block - Ext InstHEDROOM 3
5.4
16
0 9
4
149.3 ft2
0
0
0.3
0
38
S
Exterior
Concrete Block - Ext InstEEDROOM 3
5.4
14
0 9
4
130.7 ft2
0
0
0.3
0
_ 39
W
Exterior
Concrete Block - Ext Insd1EDROOM 3
5.4
14
0 9
4
130.7 ft2
0
0
0.3
0
_ 40
S
Exterior
Concrete Block - Ext Insul BATH 3
5.4
10
0 9
4
93.3 ft2
0
0
0.3
0
41
E
Exterior
Concrete Block - Ext InsulHALLWAY
5.4
35
0 9
4
326.7 ft2
0
0
0.3
0
42
E
Exterior
Concrete Block - Ext In56ITAIR 1 3RD
5.4
10
0 9
4
93.3 ft2
0
0
0.3
0
_ 43
S
Exterior
Concrete Block - Ext InsffrAIR 1 3RD
5.4
17
0 9
4
158.7 ft2
0
0
0.3
0
_ 44
N
Exterior
Concrete Block - Ext InsOW NERS BA
5.4
11
0 9
4
102.7 ft2
0
0
0.3
0
45
W
Exterior
Concrete Block - Ext Insul BATH 2
5.4
6
0 9
4
56.0 ft2
0
0
0.3
0
46
N
Exterior
Concrete Block - Ext InsQWNERS BE
5.4
14
0 10
4
144.7 ft2
0
0
0.3
0
47
S
Exterior
Concrete Block -Ext lnsOWNERS BE
5.4
14
0 10
4
144.7 ft2
0
0
0.3
0
_48
SW
Exterior
Concrete Block- Ext InsOWNERS BE
5.4
5
0 10
4
51.7 ft2
0
0
0.3
0
_49
W
Exterior
Concrete Block- Ext InsOWNERS BE
5.4
13
0 10
4
134.3 ft2
0
0
0.3
0
5/8/2020 829 AM EnergyGaugeQD USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 6 of 10
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Space
50
NW
Exterior
Concrete Block- Ext lnsOWNERS BE
5.4 5
0
10 4
51.7 ft2
0
0
0.3
0
_ 51
N
Exterior
Concrete Block - Ext InsBRAIR 2 3RD
5.4 10
0
10 0
100.0 ft2
0
0
0.3
0
_ 52
E
Exterior
Concrete Block - E t Ins8RAIR 2 3RD
5.4 11
0
10 0
110.0 ft2
0
0
0.3
0
53
N
Exterior
Concrete Block -Ext InsOWNERS TO
5.4 4
0
10 0
40.0 ft2
0
0
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated FOYER
None
.4
6
6 8
40 ft2
I WINDOWS I
Orientation shown is the entered. Pr000sed orientation.
/
Wall
V #
Ornt
ID
Frame
Panes
1
E
1
Metal
Low-E Single
2
W
2
Metal
Low-E Single
3
E
7
Metal
low-E Single
4
S
12
Metal
Low-E Single
5
W
13
Metal
Low-E Single
6
W
15
Metal
Low-E Single
7
N
16
Metal
Low-E Single
8
S
17
Metal
Low-E Single
9
SW
18
Metal
Low-E Single
10
W
19
Metal
Low-E Single
11
NW
20
Metal
Low-E Single
12
E
21
Metal
Low-E Single
13
E
24
Metal
Low-E Single
14
E
27
Metal
Low-E Single
15
N
29
Metal
Low-E Single
16
S
30
Metal
Law-E Single
17
N
31
Metal
Low-E Single
18
S
32
Metal
Low-E Single
19
W
33
Metal
Low-E Single
20
W
33
Metal
Low-E Single
21
S
34
Metal
Low-E Single
22
W
36
Metal
Low-E Single
23
N
37
Metal
Low-E Single
24
S
38
Metal
Low-E Single
25
W
39
Metal
Low-E Single
26
S
40
Metal
Law-E Single
27
E
41
Metal
Low-E Single
28
E
42
Metal
Low-E Single
29
S
43
Metal
Low-E Single
30
S
43
Metal
Low-E Single
NFRC
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
U-Factor SHGC
0.66 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.66 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
Overhang
mp
Area
Depth
Separatic
N
20.0 ft2
2ft6 in
12ft0 in
N
4.0 ft2
2it6in
24ft0 in
N
8.0 ft2
2ft6 in
24it0 in
N
12.5 ft2
2ft6in
24ft0 in
N
26.8 ft2
2ft6 in
24 it in
N
162.0 ft2
20 ft 0 in
12 ft0 in
N
21.0 ft2
2ft6in
12ft0in
N
72.0 ft2
18 It Din
12ft0in
N
25.5 112
2it6in
12 ft0 in
N
63.0 ft2
2ft6in
12ft0in
N
20.4 ft2
2It6in
12 It in
N
10.0 ft2
2ft6in
12ft0in
N
10.0 ft2
2ft6in
12 It 0 in
N
10.0 ft2
2ft6in
12 It in
N
21.0 ft2
2ft6 in
12 It 0 in
N
48.0 ft2
2ft6 in
12 It in
N
12.5 ft2
2ft6in
12it0in
N
25.0 ft2
2ft6 in
12it0 in
N
64.0 ft2
2ft6 in
12ft0 in
N
24.0 ft2
2ft6 in
12 ft0 in
N
6.3 ft2
2ft6 in
12 ft0 in
N
30.0 ft2
2ft6 in
1ft0 in
N
12.5 112
2ft6 in
1ft0 in
N
25.0 ft2
2ft6in
1ft0 in
N
30.0 ft2
2ft6in
1ft0 in
N
6.3 ft2
2it6in
1ft0in
N
40.0 ft2
2ft6 in
1ft0 in
N
12.5 112
2ft6 in
1ft0 in
N
12.5 ft2
2ft6 in
1ft0in
N
12.5 112
2ft6 in
1ft0 in
Int Shade Screening
None
None
None
None
None
None
None
None
None
None
Drapes/blinds
Exterior
Drapes/blinds
Exterior
Drapes/blinds
Exterior
Drapes/blinds
Exterior 5
Drapes/blinds
Exterior 5
Drapes/blinds
Exterior
None
None
None
None
None
None
None
None
None
None
Drapes/blinds
Exteriors
Drapes/blinds
Exterior 5
Drapes/blinds
Exteriors
Drapes blinds
Exterior
None
None
None
None
Drapes/blinds
Exterior
Drapes/blinds
Exterior
Drapes blinds
Exterior
None
None
None
None
Drapes/blinds
Exterior
Drapes/blinds
Exterior
Drapes/blinds
Exterior
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 10
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth Separation
Int Shade
Screening
31
N 44 Metal
Low-E Single
Yes
0.65 0.25 N
6.3 ft' 2 ft 6 in 1 ft 0 in
None
None
_ 32
N 44 Metal
Low-E Single
Yes
0.65 0.25 N
25.0 ft' 2 ft 6 in 1 ft 0 in
None
None
_ 33
W 45 Metal
Low-E Single
Yes
0.65 0.25 N
7.5 ft' 2 ft 6 in 1 ft 0 in
None
None
34
N 46 Metal
Low-E Single
Yes
0.65 0.25 N
6.3 ft' 2 ft 6 in 1 ft 0 in
None
None
35
N 46 Metal
Low-E Single
Yes
0.65 0.25 N
6.3 ft' 2 ft 6 in 1 ft 0 in
Drapes/blinds
Exterior 5
36
S 47 Metal
Low-E Single
Yes
0.65 0.25 N
18.0 ft' 2 ft 6 in 1 ft 0 in
Drapes/blinds
Exterior 5
37
SW 48 Metal
Low-E Single
Yes
0.65 0.25 N
17.0 ft' 2 ft 6 in 1 ft 0 in
Drapes/blinds
Exterior 5
38
W 49 Metal
Low-E Single
Yes
0.65 0.25 N
54.0 ft' 2 ft 6 in 1 ft 0 in
Drapes/blinds
Exterior 5
39
NW 50 Metal
Low-E Single
Yes
0.65 0.25 N
17.0 ft' 2 ft 6 in 1 ft 0 in
Drapestblinds
Exterior 5
40
N 53 Metal
Low-E Single
Yes
0.65 0.25 N
6.3 ft' 2 ft 6 in 1 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
1200 ft'
1200 ft-
34 ft
8 ft
5.4
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000422
4878.6 267.83 503.7 .1565
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
_ 1
Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COP:1
27 kBtu/hr
2
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
42 kBtu/hr 1260 cfm
0.8 1
sys#1
2
Central Unit/
Split
Single SEER: 16
35.2 kBlu/hr 1056 cfm
0.8 2
sys#2
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Natural Gas
None
Garage
0.6 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart
# Company Name
System Model # Collector
Model # Area
Volume
FEF
None None
ft'
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 8 of 10
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
/
— Supply----
—
Return—
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6
175 ft2
Attic
18 ft2
Prop. Leak Free
AHU 1 CLS
— cfm
73.9 cfm 0.03
0.50
1 1
2 Attic
6
150 fP
Attic
15 ft2
Prop. Leak Free
AHU 2 CLS
—cfm
58.3 cfm 0.03
0.50
2 2
TEMPERATURES
Programable[[Thermostat:
CFans:
Ian[�jjN
eb
[ ]]
Aprrjeiling
tX
�C
[�j
rjX'j
NovfjX,j
Dee
Heating [X] Jan
Feb
[X]
Mar
JuMay n t Jul
j Aug
t i $eP
Venting [[ 11 Jan l
l
1 Feb
l
1X11
Mar
Apr
[
May
Jun I Jul
I Aug
l 1 Sep
Oct �C]
Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Heating (WD)
AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
Heating (WEH)
AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
CABANA
Default(8 lbs/sq.ft.
ft2
ft
0.3
ELEVATOR 1ST FL
Default(8 lbs/sq.ft.
ft2
It
0.3
UTILITY CLST 1
Default(8 lbs/sq.ft.
ft2
ft
0.3
STAIRWELL2
Default(8 lbs/sq.ft.
ft2
ft
0.3
FOYER
Default(81bs/sq.ft.
ft2
ft
0.3
GATHERING ROO
Default(B lbs/sq.ft.
ft2
ft
0.3
STAIR 1 2ND FLR
Default(8 lbs/sq.ft.
ft2
ft
0.3
LIVING ROOM
Default(B lbs/sq.ft.
ft2
It
0.3
BACK HALL
Default(8 lbs/sq.ft.
ft2
ft
0.3
STAIR 2 UP
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ELEV 2ND FLR
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
AHU 1 CLST
Default(8 lbs/sq.ft.
fill
ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY HALL
Default(81bs/sq.ft.
ft2
ft
0.3
OFFICE
Default(B lbs/sq.ft.
ft2
ft
0.3
POWDER RM
Default(8 lbs/sq.ft.
ft2
ft
0.3
OWNERSWIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
112
ft
0.3
AHU 2 CLST
Default(8 lbs/sq.ft.
ft2
If
0.3
BEDROOM 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 9 of 10
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 lbs/sq.ft.
ft2
It
0.3
HALLWAY
Default(8 lbs/sq.ft.
ft2
It
0.3
STAIR 1 3RD FLR
Default(8 lbs/sq.ft.
ft'
It
0.3
OWNERS BATH
Default(8 lbs/sq.ft.
ft2
It
0.3
WIC2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
OWNERS BEDRO
Default(8 lbs/sq.ft.
ft'
ft
0.3
ELEV 3RD FLR
Default(8 Ibs/sq.ft.
ft2
It
0.3
STAIR 2 3RD FLR
Default(8 lbs/s.ft.
ft2
It
0.3
OWNERS TOILET
i
r
5/8/2020 8:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 10 of 10
Residential Standard Calculation 926/1997 Hribar Residence
Version 2011 L
STEP 1 Article 220.42 & 220.52
,art r±j 440B General Lighting load
6 Small Appliance
1 Laundry circuit
Gen. Lgt, Shin App.& Laun. Load
STEP 2 Article 220.50 & 220.51 Rl
A/C Condenser & Fixed Electric Space Heating
AKn i.{ VA AHU 1 rl�VA AHU2acVA AHU 3ae ea p�VA AHU4Arcx [� VA AHU5 LJ
STEP 3 Article 220.53
asmvA J�J 1 Water Heater
1MOVA 3 Refrigerator
6mv! [,V Freezer
1.010VA 1-1 1 Dishwasher
MVA '.{ 1 Disposal
"VA i+l 1 R / Hood
1.630VA I-1 1 Microwave
❑ a%0VA 1-1 Microwave
170VA .V.{ Mini Refdg
❑ COVA 1L1 Wine Clr
❑ %MVA 1.1 Insta Hot
umVA �{ Ironing Center
❑ ,e<n l..{ Jacuzzi Tub
❑ +ap {v,j Sprinkler Pump
❑ 7ap [v] Well Pump
sww I V.{ Fountain Pump
an Elevator
Pool Equip. Panel
❑ GATES
❑ Other load
STEP 4 Article 220.54
Electric Clothes Dryers
STEP 5 Article 220.55
Electric Ranges
or Number of appliances 2
13,224 VA
9,000 VA
1,500 VA
23,724 VA
3,000 VA @ 100%=
20,724 VA @ 35% _
VA @ 25% _
QTY
11,600 VA 1 1 r-1
11,600 VA IF-1-1
VA Qa [VJ
VA QV LVf
VA Qtr u
4,500 VA
Comfort Control Services
1507 SW Biltmore St
. PSL, FL, 34983
Telephone & Fax
10=191525
3,000 VA
7,253 VA
VA
General Lighting Demand Load
Total 2
Heating Load 23,200 VA
CU Load VA
Greater of Heat @ 100 % vs.A/C @ 100 %
Appliance Demand Load
4,200 VA
Dryer Demand Load
VA
1,030 VA
Range Demand Load
690 VA
400 VA
Service Demand
1,630 VA
VA
Demand Load
VA
VA
Neutral Demand
VA
VA
Min.Service Req.
VA
1, 127 VA
Min. Feeder size
1,127 VA
Min. Neutral size
VA
Eq. Girding Cord.
VA
❑
5,175 VA
100 % Demand
VA
No Demand
VA
No Demand
Total Appliance Load 19,879 VA
4 or more
demand @ 75% plus 100% demand loads
5,000 VA
Col C demand 11000
Cooktop Col B demand
❑ check Bmc for Gas Range Cooktop 8,000 W Col B demand
Oven(s) 8,000 W Col B demand
Oven(s) Col B demand
Number of appliances 2 Dem. Factor 65%
Cooktop & Oven Demand Load 10,400 W
nuous 0 ......
Spa heater 11 kVA , , , , ,
0
0
0
0
0
10,253 VA
23,200 VA
16,203 VA
5,000 VA
10,400 VA
65,056 VA
271 A
114 A
300 A
250
2
4
Copper
16,203 VA
15p �1❑ 240v <.W r.f ❑ 240v
etet J.l❑ 240V akR I.f ❑ 240V
eektt ��{❑ 240V wkn J�,I ❑ 240V
elect "� ❑ 240v ,eied ❑ 240v
0.0 Motor Neutral Load
Max.Unbalanced Neutral Load
1
Pool Panel Feeder Calculation (see Note) A B IN Continuous Non-confnuous
Continuous Motors 2,875 ...... 7438 1438 0 Motors Motors
Non -conti
240V eeW [.I ❑ 240V
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: HRIBAR RESIDENCE Builder Name:
Street: LOT *4 LAS TORTUGAS Permit Office: ST LUCIE COUNTY
City, State, Zip: ST LUCIE, FL, Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
W
x
Design Location: FL, Fort Pierce
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier In any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
Thejunction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shallbe sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be In contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavites shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed In the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neally to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs,
insulated.
Electricat/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
10/3/2019 3:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location varies
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 77.2
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 4408 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.650
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250
c) Area 7c. 1000.7
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b. 19.0
9c.
10A1. 19.0
10A2. 5.4
10131.
10132. 5.4
11a. 0.0
11 b.
11 c.
11d. No
14. Heating system: Capacity 54.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE -
f) Other
15. Water heating system
a) Electric resistance EF
b) Gas fired, natural gas EF 0.60
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
0 Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
0 Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: Z
Address of New Home: LOT #4 LAS TORTUGAS City/FL Zip: ST LUCIE. FL
10/3/2019 3:03:44 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1