HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C?,NS$R Ne
ION
Florida Department of Business and Professional Regulation - Residential Pei'ft2 'ari? od
9
Project Name: Adams Homes - 2320 Model - 5313 Birch Dr
Builder Name: Adams Homes
Street: 5313 Birch Drive
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34982
Permit Number:
Owner: Adams Homes - 2320 Model
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1900.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1700.20 ft2
b. Frame - Wood, Adjacent
R=11.0 200.00 ft2
3. Number of units, if multiple family 1
c. N/A
R=
4. Number of Bedrooms 4
d. N/A
ft2
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2332.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2332.00 112
6. Conditioned floor area above grade (ft2) 2332
b. N/A
R= ft2
Conditioned floor area below grade (112) 0
c. N/A
R= ft
11. Ducts
R ft2
7. Windows(238.0 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU
6 105
a. U-Factor: Sgl, U=0.33 166.03 ft2
SHGC: SHGC=0.23
b. U-Factor: Sgl, U=0.33 72.00 ft2
12. Coolingsystems
k0tu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
40.0 SEER:14.50
c. iJ-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
40.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.224
14. Hot water systems
8. Floor Types (2332.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2332.00 ft2
b. Conservation features
EF: 0.950
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
GlasslFloorArea: 0.102 Total Proposed Modified Loads: 71.91
PASS
Total Baseline
Loads: 72.49
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
OF�iiES7,
Code.
calculation indicates compliance
�Qk1 LL/ J[�
with the Florida Energy Code.
PREPARED BY: yYLSSJJLL SS�� mm
Before construction is completed
DATE: 12-9-19
this building will be inspected for
_ Y
compliance with Section 553.908
,
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code
00 WF.1
OWNER/AGF
BUILDING OFFICIAL:
DATE: c
DATE:
ft
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as tq
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this projeq ires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Y
12/8/2019 4:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405.2017 INPUT SUMMARY r14F:rll(I IRT RFDnRT
PROJECT
Title:
Adams Homes - 2320 Model -
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2332
Lot#
Owner Name:
Adams Homes - 2320 Model
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Adams Homes
Rotate Angle:
0
Street:
5313 Birch Drive
Permit Office:
St. Lucie County
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan:
No
City, State,
Zip:
Fart Pierce ,
Family Type:
Single-family
FL, 34982
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2332
20612.6
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
Bedroom 4
175
1400 No
1
1
1
Yes
Yes
Yes
2
Bath
60
480 No
0
1
Yes
Yes
Yes
3
Hall
118
944 No
0
1
Yes
Yes
Yes
4
Bedroom 3
151
1208 No
1
1
1
Yes
Yes
Yes
5
Bedroom 2
210
1680 No
1
1
1
Yes
Yes
Yes
6
Family Room
338
3447.6 No
2
1
Yes
Yes
Yes
7
Foyer
72
720 No
0
1
Yes
Yes
Yes
8
Dining Room
182
1820 No
2
1
Yes
Yes
Yes
9
Breakfast Nook
146
1357.8 No
2
1
Yes
Yes
Yes
10
Kitchen
224
2307.2 Yes
2
1
No
Yes
Yes
11
Laundry
96
768 No
0
1
No
Yes
Yes
12
AHU
18
144 No
0
1
No
Yes
Yes
13
WIC
63
504 No
0
1
Yes
Yes
Yes
14
Master Bath
108
864 No
0
1
Yes
Yes
Yes
15
Master Bedroom
255
2040 No
2
1
1
Yes
Yes
Yes
16
Toilet
24
192 No
0
1
Yes
Yes
Yes
17
Hall
92
736 No
0
1
No
Yes
Yes
12/8/2019 4:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Bedroom 4
28 ft
175 ft'
_---
1
0
0
2 Slab -On -Grade Edge Insulatio
Bath
E ft
60 ft'
1
0
0
3 Slab -On -Grade Edge Insulatio
Hall 2
1 ft
118 ft'
_-__
1
0
0
4Slab-On-Grade Edge Insulatio
Bedroom 3
16 ft
151 ft'
____
1
0
0
5 Slab -On -Grade Edge Insulatio
Bedroom 2
44 ft
210 ft'
____
1
0
0
6 Slab -On -Grade Edge Insulatio
Family Room
13 ft
338 ft'
____
1
0
0
7Slab-On-Grade Edge Insulatio
Foyer
8 ft
72 ft'
__-
1
0
0
8 Slab -On -Grade Edge Insulatio
Dining Room
18 ft
182 ft'
____
1
0
0
9 Slab -On -Grade Edge Insulatio
Breakfast Nook
20.9 ft
146 ft'
____
1
0
0
10SIab-On-Grade Edge Insulatio
Kitchen
1 ft
224 ft'
____
1
0
0
11SIab-On-Grade Edge Insulatio
Laundry
1 ft
96 ft'
_-__
1
0
0
12SIab-On-Grade Edge Insulatio
AHU
1 ft
18 ft'
____
1
0
0
13SIab-On-Grade Edge Insulatio
WIC
7 ft
63 ft'
-___
1
0
0
14SIab-On-Grade Edge Insulatio
Master Bath
6 It
108 ft'
___-
1
0
0
15SIab-On-Grade Edge Insulatio
Master Bedroom
32 It
255 ft'
____
1
0
0
16SIab-On-Grade Edge Insulatio
Toilet
6 ft
24 ft'
__-_
1
0
0
17SIab-On-Grade Edge Insulatio
Hall 1
1 ft
92 ft'
____
1
0
0
ROOF
/
Roof
Gable Roof
Red
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2608 ft'
0 ft' Medium
N
0.6 No 0.9
No
0
26.6
ATTIC
/
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
300 2332 ft2
N N
12/8/2019 4:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Bedroom 4
30
Batt
175 ft2
0.1
Wood
2
Under Attic (Vented) Bath
30
Batt
60 ft2
0.1
Wood
3
Under Attic (Vented) Hall
30
Batt
118 ft2
0.1
Wood
4
Under Attic (Vented) Bedroom 3
30
Batt
151 ft2
0.1
Wood
5
Under Attic (Vented) Bedroom 2
30
Batt
210 ft2
0.1
Wood
6
Under Attic (Vented) Family Room
30
Batt
338 ft2
0
Wood
7
Under Attic (Vented) Foyer
30
Batt
72 ft2
0.1
Wood
8
Under Attic (Vented) Dining Room
30
Batt
182 ft2
0.1
Wood
9
Under Attic (Vented) Breakfast Nook
30
Batt
62 ft2
0.1
Wood
10
Under Attic (Vented) Breakfast Nook
30
Batt
84 ft2
0
Wood
11
Under Attic (Vented) Kitchen
30
Batt
224 ft2
0
Wood
12
Under Attic (Vented) Laundry
30
Batt
96 ft2
0.1
Wood
13
Under Attic (Vented) AHU
30
Batt
18 ft2
0.1
Wood
14
Under Attic (Vented) WIC
30
Batt
63 ft2
0.1
Wodd
15
Under Attic (Vented) Master Bath
30
Batt
108 ft2
0.1
Wood
16
Under Attic (Vented) Master Bedroom
30
Batt
255 ft2
0.1
Wood
17
Under Attic (Vented) Toilet
30
Batt
24 ft2
0.1
Wood
18
Under Attic (Vented) Hall 1
30
Batt
92 ft2
0.1
Wood
WALLS
Adjacent Space
pp
Cavity
Width
Height
Sheathing Framing
Solar
Below
a
1
N
Exterior Concrete Block - Ext InstBedroom 4
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
2
W
Exterior Concrete Block - Ext InstBedroom 4
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
3
W
Exterior Concrete Block - Ext Insul Bath
4.1
6
0 8
0
48.0 ft2
0
0
0.6
0
4
E
Exterior Concrete Block - Ext Insul Hall 2
4.1
1
0 8
0
8.0 ft2
0
0
0.6
0
5
W
Exterior Concrete Block - Ext InsiBedroom 3
4.1
16
0 8
0
128.0 ft2
0
0
0.6
0
6
E
Exterior Concrete Block - Ext lnsLBedr00m 2
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
7
S
Exterior Concrete Block - Ext InsLBedroom 2
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
8
W
Exterior Concrete Block - Ext InstBedroom 2
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
9
N
Exterior Concrete Block - Ext Inffdmily Room
4.1
10
2 10
3
104.2 ft2
0
0
0.6
0
10
S
Exterior Concrete Block - Ext Insul Foyer
4.1
8
0 10
0
80.0 ft2
0
0
0.6
0
11
S
Exterior Concrete Block - Ext InOlning Room
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
12
W
Exterior Concrete Block - Ext IndDIning Room
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
_ 13
N
Exterior Concrete Block - Ext InsBteakfast No
4.1
5
2 9
4
48.2 ft2
0
0
0.6
0
14
NE
Exterior Concrete Block - Ext InsiBleakfast No
4.1
3
10 9
4
35.8 ft2
0
0
0.6
0
15
E
Exterior Concrete Block - Ext In99teakfast No
4.1
2
7 9
4
24.1 ft2
0
0
0.6
0
16
W
Exterior Concrete Block - Ext InsWeakfast No
4.1
2
7 9
4
24.1 ft2
0
0
0.6
0
17
NW
Exterior Concrete Block - Ext Insibleakfast No
4.1
3
10 9
4
35.8 ft2
0
0
0.6
0
18
E
Exterior Concrete Block- Ext Insul WIC
4.1
7
0 8
0
56.0 ft2
0
0
0.6
0
19
E
Exterior Concrete Block - Ext InsMaster Bath
4.1
6
0 8
0
48.0 ft2
0
0
0.6
0
_20
N
Exterior Concrete Block - Ext Intiihster Bedro
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
_21
E
Exterior Concrete Block - Ext ImMbster Bedro
4.1
17
0 8
0
136.0 ft2
0
0
0.6
0
_22
E
Exterior Concrete Block- Ext Insul Toilet
4.1
6
0 8
0
48.0 ft2
0
0
0.6
0
12/8/2019 4:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
• FORM R405-2017 INPUT SUMMARY CHECKLIST RF_PORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
0
_23 E
Garage
Frame - Wood
WIC
11 9
8
72.0.1ft'
0.23 0.6
0
_24 E
Garage
Frame - Wood
Laundry
11 12
8
96.0:ft2
0.23 0.6
0
_25 N
Garage
Frame - Wood
Dining Room 11 4
8
32.0 ft2
0.23 0.6
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood
Family Room
None
.39
2
10
6 10
19.4 ft-
2
S
Wood
Foyer
None
.39
3
6 10
20.5 ft'
WINDOWS
Orientation shown is the entered, Pro osed orientation.
/
Wall
Overhang
V #
Ornt ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade.
Screening
1
N
1
Vinyl
Low-E Single
Yes
0.33 0.23.
N
15.0 ft2
2 ft 0 in
0 ft 7 in
None
None
2
W
5
Vinyl
Low-E Single
Yes
0.33 0.23
N
15.0 ft'
2 ft 0 in
0 ft 7 in
None
None
3
S
7
Vinyl
Low-E Single
Yes
0.33 0.21
N
30.0 ft2
2 ft 0 in
4 ft 5 in
None
None
4
N
9
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft'
2 ft 0 in
0 ft 7 in
None
None
5
S
10
Vinyl
Low-E Single
Yes
0.33 0.23
N
10.0 ft2 .
2 ft 0 in
1 ft 4 in
None
None
6
S
10
Vinyl
Low-E Single
Yes
0.33 0.23
N
13.7 ft2
2 ft 0 in
1 ft 4 in
None
None
7
S
11
Vinyl
Low-E Single
Yes
0.33 0.21
N
12.0 ft2
2 ft 0 in
1 ft 0 in
None
None
8
S
11
Vinyl
Low-E Single
Yes
0.33 0.21
N
30.0 ft2
2 ft 0 in
1 ft 0 in
None
None
9
N
13
Vinyl
Low-E Single
Yes
0.33 0.23
N
20.0 ft'
2 ft 0in
0 ft 7 in
None
None
10
NE
14
Vinyl
Low-E Single
Yes
0.33 0.23
N
8.7 ft2
2 ft 0 in
0 ft 7 in
None
None
11
NW
17
Vinyl
Low-E Single
Yes
0.33 0.23
N
8.7 ft'
2 ft 0 in
0 ft 7 in
None
None
12
N
21
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft2
2 ft 0 in
0 ft 7 in
None
None
13
E
22
Vinyl
Low-E Single
Yes
0.33 0.23
N
15.0 ft2
2 ft 0 in
0 ft 7 in
None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
462 ft2
462 ft2
25 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000393 2404.8 132.02
248.28
.1418
7
12/8/2019 4:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.2
40 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flaw
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 14.5 40 kBtu/hr
cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Carl # Company Name
System Model# Collector Model#
Area
Volume
FEF
None None
ft.
DUCTS
/ — Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic 6 105 fN
Attic
25 ft- Default Leakage
AHU
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
C([ei]]ling Fans:
Cooling Ian Feb Me
rr
]
]
Jul
[[ ]]
t[[
Nov
Dec
Venting Jan Feb �Xj
Apr
Jun 4X1
May
[X] Aug
]] Sep
([
€
lxJ lXl Marl
[
] lXl Jun [ 1JuI
[[ 1l Aug
[ Sep
LXl
Oct
[X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM 78
78
78
78 78 78
78
78
80
80
80
80
PM 80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM 78
78
78
78 78 78
78
78
78
78
78
78
PM 78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD) AM 66
66
66
66 66 68
68
68
68
68
68
68
PM 68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM 66
66
66
66 66 68
68
68
68
68
68
68
PM 68
68
fib
68 68 68
68
68
68
68
66
66
12/8/2019 4:55 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Bedroom 4
Default(8 lbs/sq.ft.
ft2
ft
0.3
Bath
Default(8 lbs/sq.ft.
ft2
ft
0.3
Hall
Default(8lbs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Family Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Breakfast Nook
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 lbs/sq.ft.
ft2
ft
0.3
AHU
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 lbs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8 lbs/sq.ft.
ft2
ft
0.3
Toilet
Default(8 lbs/sqA.
ft2
ft
0.3
Hall
12/8/2019 4:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Adams Homes - 2320 Model - 5313 Birch Dr Builder Name: Adams Homes
Street: 5313 Birch Drive Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34982 Permit Number:
Y
Owner: Adams Homes - 2320 Model Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
x
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the lop side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
m.
Recessed fighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical orcommunication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
��pognhler cover plates and walls or ce lincis.
Ouultlull, IIIbVVuUUII vi iey wdub Snail be in accordance With the provisions or iCC-400.
12/8/2019 4:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: St. Lucie County
Permit#:
b&T€��. y%`F�" N '".. i{'^ V5¢,'"�M�f �i M'Ce# ,^.rtT `C iT a-'•R 4'�rt'+s p�, q y4t�+H R Y 'M lT '..nrc" rsE
C 4 i '"„ � {� r�i' ,•� �4 4P } yyMrt AYYiji• t PT � mA` b.N £°,�;"ry`({ ll YBYe� 8} fP'R .',j
m'Y"�c f :.n ;r`�'*�'.t'�ar Y•7^ aT '4M1eriw�.-'^S.. '�"r� n'Jy ? i" �'ri+e,''t 5�1i7^h.}�w,{:c �g1'C�kk � �P� �xu��H���1t-ix,r sM7&L.
��+t
t, ti�14
fJob;tnformatton_�.i � �a�..'.'i�.`s�txsc;�.� �Y���z �,��,�' �bf� u.:.;�� :.,F,d�
�ni .,.�.��=��.���`"� � •�:.;:��>s
Builder: Adams Homes Community: Lot: NA
Address: 5313 Birch Drive
City: Fort Pierce State: FL Zip: 34982
};`'^..i'.O �`5 � '�Y YL�§� �C�.'.� wy�i Y•K 6�£...+. m�-'1e^w- i .-�iN�` f�' '>4... ��P' �iw AS�u TQ•:•-k t L`5"4 -" F {,
Atr Leakage Test Resatts-W +Passrn resoftsPmristmeeierfherlthe Performance Prescnptrve^✓'op€RG'Method L
Y-�"C'. "�-c��xeq
n"Y. ",y-'"{(ryR�i a.�`TM1 �C��,4
k�¢� t"'1. � l.S'yy �,�ax4r�Yy-�S� 'ir�.^� {Y'✓'Fey�e*}s.''�i f.,��$n 4W,'�' yk .vA` y F -z v..r
4tE%-Y.�''.ti4�:"^Ff1$ia1NFfL�`..{,Ba�:.&�i'+uiYl+y�W.rJtT1'v.hfM[YYu'G¢t}µib�.Wt`>+. �4wbl''W��Y4�i%=A'e}Frv'J��'.
xra�4n nby+4"J%4"rG_'Y,.Mv,'nt
A��rv1A ak;rv•Iba%�+naii4'�fi�$sN{���5'A3�fvi'a�
PREBCRIP�T�VE+JJIETHOD Th�bwld� or dwelling untt shall betiested-and `v having
Us' g enfiedas an.au leakage rate of not exceeding 7=cairy- yy
�W�„ � changes peer hou�at �prure o�0 2 inch w g (50 P„a�sca�s���n`Olfmate�ones 1�a�nd�2�' � �.,s_�. r >,rt �n r'tiz°; �"Ay' �;j
� y, �
�
�y'M !� k SY' 'K� 3+�'N.1�i.FiP4-b i �•�'S �YX'L ..b54.-�'F3, Ei^Y'{Y' nt�>�M � 9 ig4l Y H i L 1. ��. ��04�•�:'S.e!FfS' �,. t� _�',2 }�' 'j?YJ4i`Y'.
-.QzCPERFORMANCE,or ERI METHOD,Tebwlding or dwelhnmt shall bye, tesbd a�nd;yenfied as�hawQg an"aileakage raegdf note�`edtng
the selected ACH(50j value cas shown n Form R40 2017 (Performapce) o+rR406 2017 (ERI)�section labeled as, r_nt ltratioy ufrsectiop ACH50.
+� � '� � '+� 4ACH 50) s ecrfe on'Form`R405 2017 Energy Ca/c ( erfo�imanc� br'R406 2017 ERl '""} 7.000 r`�'�x °w x+
tt$ d-+, k.a'�4x.�",d,5t�^,.ar-Gi'�,. e�Y�r{h.4-',�+Fs„�v.�:?:g�d`.a �✓�C a;�;x xI ";; ,�,+a.t��t.i�.. ,.'C,,�i. .:�y .v+5m_'ea..��s%(i �:'�ita�;�brv.�'�Y1i.x
x 60 20613 = Method for calculating building volume:
CF9(50) Building Volume ACH(50)
O Retrieved from architectural plans
❑ PASS Code
• software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and Flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Company Name: Phone:
I hereby verify, that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
12/8/2019 4:58:22 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
AHU
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
40.0
a) Split system SEER
14.5
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2332
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.330
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.224
14. Heating system: Capacity
40.0
c) Area
7c.
238.0
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
Ba.
NA
d).Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood; raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
9 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
1la.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: ��
c
Address of New Home: 5313 Birch Drive City/FL Zip: Fort Pierce, FL 34982
12/8/2019 4:57:19 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1