Loading...
HomeMy WebLinkAboutEnergy Coder 'ARM R406-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project N@me: ADAMS HOMES 2020 MERANO AVE Builder Name: ADAMS HOMES Street: 8604 MERANO AVENUE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE. FL, Permit Number: Owner: Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1973.5 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1693.50 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 280.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2595.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 2595.00 ft2 6. Conditioned floor area above grade (ft2) 2021 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(166.3 sgft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: LAUNDRY R 112 6 205 a. U-Factor. Sgl, U=0.33 101.33 ft2 SHGC: SHGC=0.23 b. U-Factor: Sgl, U=0.33 65.00 ft2 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.21 a. Central Unit 40.0 SEER:14.50 c. U-Factor: NIA ft2 SHGC: d. U-Factor: N/A 13. Heating systems kBtu/hr Efficiency ft2 SHGC: a. Electric Heal Pump 42.0 HSPF:8.50 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.222 14. Hot water systems 8. Floor Types (2020.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2020.00 R2 b. Conservation features EF: 0.950 b. N/A R= ft2 None c NIA R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.082 Total Proposed Modified Loads: 59.72 PASS Total Baseline Loads: 62.78 I hereby certify that the plans and specifications covered by Review of the plans and S7,1r� this calculation are in compliance with the Florida Energy specifications covered by this �fI.10 Code. calculation indicates compliance with the Florida Energy Code. h rrnrr• ':; =.` "`;;.�"„ �O PREPARED BY:� Before construction is completed r� " DATE: 10-28-19 this building will be inspected for t compliance with Section 553.908 .. I hereby certify that this building, as designed, is in compliance with the Florida Energy Florida Statutes. 4 Code. G0D W-E OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project es an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10128/2019 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 6 FCAA R-4o5-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ADAMS HOMES 2020 MERA Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 2021 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlalBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8604 MERANO AVENU Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2021 23698.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 GREAT ROOM/NO 464 5707.2 No 0 1 Yes Yes Yes 2 OWNER SUITE 216 2640 No 2 1 Yes Yes Yes 3 OWNER BATH 117 1170 No 0 1 Yes Yes Yes 4 TOILET 15 150 No 0 1 Yes Yes Yes 5 BEDROOM 2 133 1622 No 1 1 Yes Yes Yes 6 BEDROOM 3 155 1893 No 1 1 Yes Yes Yes 7 BEDROOM #4 159 1952 No 1 1 Yes Yes Yes 8 WIC 60 595 No 0 1 No Yes Yes 9 BATH 2 66 i 660 No 0 1 No Yes Yes 10 HALL 97 979 No 0 1 No Yes Yes 11 LAUNDRY 64 640 No 0 1 No Yes Yes 12 KITCHEN 192 2360 No 0 1 Yes Yes Yes 13 DINING ROOM 156 1907 No 0 1 Yes Yes Yes 14 FOYER 127 1417 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio GREAT ROOM/N 45 ft 0 464 fl' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio OWNER SUITE 12 It 0 216 ft2 ____ 0 1 0 3SIab-On-Grade Edge Insulatio OWNER BATH 15 ft 0 117 ft2 ____ 0 1 0 4Slab-On-Grade Edge Insulatio TOILET 811 0 15 ft2 ____ 0 1 0 10/28/2019 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHFCKI IST RFPnRT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio BEDROOM 2 13 ft 0 133 ft2 -_ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 3 11 ft 0 155 ft2 ___ 0 1 0 7 Slab -On -Grade Edge Insulatio BEDROOM #4 11 ft 0 159 ft2 ____ 0 1 0 • 8 Slab -On -Grade Edge Insulatio WIC 1 ft 0 59.5 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 2 1 ft 0 66 ft2 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 It 0 96.5 ft2 ___ 0 1 0 11SIab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 64 ft2 — 0 1 0 12SIab-On-Grade Edge Insulatio KITCHEN 16 ft 0 192 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulatio DINING ROOM 29 ft 0 156 ft2 ____ 0 1 0 14Slab-On-Grade Edge Insulatio FOYER 9 ft 0 127 ft2 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emilt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2129 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2020 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) GREAT ROOM/N 30 Blown 572 ft2 0 Wood 2 Under Attic (Vented) OWNER SUITE 30 Blown 303 f12 0 Wood 3 Under Attic (Vented) OWNER BATH 30 Blown 117 ft2 0.1 Wood 4 Under Attic (Vented) TOILET 30 Blown 15 ft2 0.1 Wood 5 Under Attic (Vented) BEDROOM 2 30 Blown 202 ft2 0 Wood 6 Under Attic (Vented) BEDROOM 3 30 Blown 2 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 3 30 Blown 238 ft2 0 Wood 8 Under Attic (Vented) BEDROOM #4 30 Blown 243 ft2 0 Wood 9 Under Attic (Vented) WIC 30 Blown 60 ft2 0.1 Wood 10 Under Attic (Vented) BATH 2 30 Blown 66 ft2 0.1 Wood 11 Under Attic (Vented) HALL 30 Blown 91 ft2 0.1 Wood 12 Under Attic (Vented) HALL 30 Blown 9 ft2 0 Wood 13 Under Attic (Vented) LAUNDRY 30 Blown 64 ft2 0.1 Wood 14 Under Attic (Vented) KITCHEN 30 Blown 237 ft2 0 Wood 15 Under Attic (Vented) DINING ROOM 30 Blown 234 ft2 0 Wood 16 Under Attic (Vented) FOYER 30 Blown 63 ft2 0.1 Wood 17 Under Attic (Vented) FOYER 30 Blown 79 ft2 0 Wood 10/28/2019 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 SE Exterior Concrete Block - Ext InEMREAT ROO 4.1 23 7 12 4 290.9 ft' 0 0 0.6 0 2 SW Exterior Concrete Block- Ext InSBREAT ROO 4.1 13 0 12 4 160.3 ft' 0 0 0.6 0 3 SW Exterior Concrete Block - Ext InsQWNER SUI 4.1 9 10 12 3 120.5 ft' 0 0 0.6 0 4 SW Exterior Concrete Block - Ext In9WNER BAT 4.1 6 0 10 0 60.0 ft' 0 0 0.6 0 5 NW Exterior Concrete Block- Ext In1MNER BAT 4.1 9 0 10 0 90.0 ft' 0 0 0.6 0 _6 SW Exterior Concrete Block -Ext lnsulTOILET 4.1 5 0 10 0 50.0 ft' 0 0 0.6 0 _ 7 NW Exterior Concrete Block -Ext InsuITOILET 4.1 3 0 10 0 30.0 ft' 0 0 0.6 0 8 NW Exterior Concrete Block - Ext InSEDROOM 2 4.1 10 8 12 2 129.8 ft' 0 0 0.6 0 9 NW Exterior Concrete Block - Ext InfiEDROOM 3 4.1 9 0 12 3 110.3 ft' 0 0 0.6 0 _10 NW Exterior Concrete Block -Ext lnfiffDROOM# 4.1 9 0 12 3 110.3 ft' 0 0 0.6 0 _11 SE Exterior Concrete Block -Ext lnsuKITCHEN 4.1 13 0 12 4 160.3 ft' 0 0 0.6 0 _12 NE Exterior Concrete Block - Ext InONING ROO 4.1 9 10 12 3 120.5 ft' 0 0 0.6 0 13 SE Exterior Concrete Block - Ext InOMING ROO 4.1 10 8 12 3 130.7 ft' 0 0 0.6 0 _14 NW Exterior Concrete Block -Ext In9MING ROO 4.1 3 3 12 3 39.8 ft' 0 0 0.6 0 _15 NE Exterior Concrete Black- Ext Insul FOYER 4.1 7 2 11 2 80.0 ft' 0 0 0.6 0 _16 NW Exterior Concrete Block -Ext lnsul FOYER 4.1 0 11 11 2 10.2 ft' 0 0 0.6 0 17 N Garage Frame - Wood GREAT ROO 11 28 10 280.0 ft' 0 0.25 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated FOYER None .39 3 6 8 20 W WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 it 7 in None None 2 SW 2 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft' 2 ft 0 in 0 ft 7 in None None 3 SW 3 Vinyl Low-E Single Yes 0.33 0.21 N 20.0 ft' 2 it 0 in 0 ft 7 in None None 4 SW 4 Vinyl Low-E Single Yes 0.33 0.23 N 11.3 ft' 2 It 0 in 0 ft 7 in None None 5 NW 8 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None 6 NW 9 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 W 2 it 0 in 0 it 7 in None None 7 NW 10 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 it 7 in None None 8 NE 12 Vinyl Low-E Single Yes 0.33 0.21 N 30.0 ft' 2 ft 0 in 0 ft 7 in None None 9 SE 13 Vinyl Low-E Single Yes 0.33 0.21 N 15.0 ft' 2 it 0 in 0 ft 7 in None None 10/28/2019 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 376.36 ft- 376.36 ft' 26 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000521 2764.1 151.74 285.38 .2105 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit( Split SEER: 14.5 40 kBlu/hr 1200 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Carl# Company Name Collector Storage System Model# Collector Model# Area Volume FEF None None ft= DUCTS / V # -- Supply -- Location R-Value Area --- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 205 ft- Attic 85 ft' Default Leakage LAUNDRY (Default) • (Default) 1 1 10128/2019 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ' TEMPERATURES Programablre Thermosta[[t:]]Y CEei]]ling Fans: Heating Jan fx� Mar M:yJun [[ ]] Jul f ]] ] jF Oct jjj Nov Dec [X� [X] Feb Apr May [X) r Aug 4X] Sep H Venting III[ 111 Jan [[ 11 Feb [X Mar l l [ ] lXl Jun II 11 Jul [ Aug [ 1 Sep lll//���1 Oct l Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 7e 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating IWO) AM fib 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 fib 68 68 68 68 fib 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 GREAT ROOM/NO Default(8 lbs/sq.ft. ft' ft 0.3 OWNER SUITE Default(8 lbs/sq.ft. fl' ft 0.3 OWNER BATH Default(8 lbs/sq.ft. ft' ft 0.3 TOILET Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM #4 Default(8 lbs/sq.fl. ft' ft 0.3 WIC Default(8 Ibs/sq.fl. ft' ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft. ft 0.3 HALL Default(8 lbs/sq.ft. fl' ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft' ft 0.3 DINING ROOM Default(8 lbs/s .ft. ft' ft 0.3 FOYER 10/28/2019 9:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition ST. LUCIE COUNTY Permit #: (Jurisdiction: Builder: ADAMS HOMES Community: Lot: NA Address: 8604 MERANO AVENUE City: FT. PIERCE State: FL Zip: SY24 f','M'Yt S AfL�fi'�M FePie{Jf� J.Nn �.� } � 4a MJ F�...: �t YY'.4 „ C'.K 4�•'i f� "'FV `G.FJ�`F � y-j f.y y �AirxLeakage��,.iest�ResultS� aPassrng�esultsmustjjmeet,ertherthePerforma�ceLPrescnphve or,-ERI Method` S h 5 �✓'4y.. Y� i�✓ ''� V: ?;"'". fiy`1 ZvB 7 .yNr fll / S IS l �2S yS^{S �,y. 3e/ T- .f � �i G�4 t � ����.+'i �' �_�.YeL a'Y+r<�'.34�✓. S�n�i-'Y'?i m.3.� <IJwka. s'Y..� -1 }3 SN4. TS34W-eKf .a �a'._ r. 4AY�Mi� ral�-'i eY�.� ����i., e PR SCRIPTIVE M THOD�Theautidin or v nfied as haven an rleak w`ellm unitsliall be t sted'and a rate of ftjTz 7 air, gnu a x .Cote ,1¢;�sr,",�changes perhour af�a pressure df 0 2 nch w';g (50 Pascals) ni Climate Zones 1 and 2� z � csJ � $r..''x A..r�a �< tka ��.�x4=°5^.r}�5..'GY'�r?_���i..^ar.51.Si��-.ram..-�r..w .. Yl3: te......s,`�..R� As'P..,?%�.�Y�`��ri_+��Yv....aT�-+�aS.+��w[in�.....".�1 ±a.'➢�3..=h-..{.e-`�-4-•� j.'.,s e�� PERFORMANCE or ERI METHOD7he bmldl'ng or dwelling unit s�iall be tested and 'enfied"`as having an aRr lea age ranot exceedI te ob the selectedd ACH(50) va{ue'as shover on Fo m 1 4115 2017 (Perfor adce) o� R406 2017 (ERI} section labeled as,in'_filtrabon s6b secbon ACHSU, x 4 ACH(50) specvfied on Form R405-2017 Energy,Calc (Performance) or R408 2017^(ERI) „ . 7.000 x 60 23692 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the parry conducting the test and provided to lhecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. AI. w3.E pxa'` v✓'b: Tk P $ '�... 3 , 'i .L9 4.i.� l�P � y�'4A h� i'„ �Zrj. f .,Y JS$' .".` -Al': '� ..�"- Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 10/28/2019 9:24:44 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 201Y - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ADAMS HOMES 2020 MERANO AVE Builder Name: ADAMS HOMES Street: 8604 MERANO AVENUE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: t Owner: Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Thejunction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including above -garage insulation. maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity paces. Garage separation Air sealing shall be provided between the garage and conds. Recessed lighting Recessed light fixtures installed in the building thermal envRecessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring nd plumbing in exterior walls, or insulation that on nstallation readily conforms to available space shall Shower/tub on exterior wall The air barrier installed at exterior walls adjacent to showerxterior Bced walls adjacent to showers and tubs shall tubs shall separate them from the showers and tubs.e insulated. Electrical/phone box o The air barrier shall be installed behind electrical or commu exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelobe sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shallsprinklers sealed in a manner that is recommended by the manufactuCaulking or other adhesive sealants shall not be used to fill a. In addition. insoection of Inn want <f,�u Fe �,. ��.....,��.,..e ..,:ram..._ -._.,walls or ,_,___ _ 10/28/2019 9:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 21117 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (ifmultiple-family)3. 1 c) AHU location LAUNDRY 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 40.0 5. Is this a worst case? (yes/no) 5. No a) Split system SEER b) Single package SEER 14.5 c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2021 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.222 14. Heating system: Capacity 42.0 c) Area 7c. 166.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 9. Floor type, insulation level: 0 Other a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 10. Wall type and insulation: b) Gas fired, natural gas EF c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10132. 11. Ceiling g type and insulation level 16. HVAC credits claimed (Performance Method) a) Under attic 11a. 30.0 a) Ceiling fans b) Cross ventilation Yes No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signa' --� �� Date: �9 Address of New Home: 8604 MERANO AVENUE City/FL Zip: FT. PIERCE, FL 10/28/2019 9:24:25 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1