THRESHOLD INSPECTION REPORT
OCEAN HARBOR NORTH CONDOMINIUMS—BLDG.D CONCRETE REPAIRS
5163 N.HWY.AlA,FT.PIERCE,FL 34949
SLC BUILDING PERMIT NUMBER:2002-0526
PROJECT NAME: Ocean Harbor N.Condos—Bldg.D DATE: May 6,2020
Concrete Repairs
CLIENT: Elliott Merrill Community Management LOCATION: Ft.Pierce,FL
CONTRACTOR: Structure-Con PROJECT MGR: Mr.Khris McConnell
--__ — -INSPECTED-BY:--- ---Todd-Rhoten - _ -WEATHER: Sunny-&breezy
WORK INSPECTED:
Units 216/316,320/420,416/516,520/620, 616/716&620/720—Post pour&Cable retensioned.
OBSERVATIONS:
Cables have been re-tenstioned,cable ends have been cut and grease caps were placed. Quantities as follows:
o Unit 216/316_(1)cable @ north edge.
o Unit 320/420—(8)cables @ east edge&(3)cables @ south edge.
o Unit 416/516—(2)cables @ north edge.
o Unit 520/620-(2)cables @ south edge.
o Unit 616/716—(1)cable @ northeast corner.
o Unit 620/720—(1)cable @ southeast corner.
• Contractor is to grout pockets with a non-shrink,high strength grout.
• Guardrail posts are to be anchored at repaired areas with a 3/8"diameter stainless steel epoxy threaded anchor
with nuts&washers.
• _-Stucco finish is in progress.at repaired areas.
All work-to date coiriplies-with the design and permit documents.
sWanr Yc z w�
z
Michael Lue,P.E. Todd Rhoten
Pagel of 2
M L Engineering Inc. Project No. 20-104 Report No. 11
Consulting Engineers Project Manager: Mr.Gene Ross—Elliott Merrill Community Mgmnt.
Threshold Inspector Building Official: St.Lucie County Bldg.Dept.
2030 371'Avenue Contractor: Mr.Robert Stark—Structure-Con
Vero Beach,Florida 32960 Mr.Khris McConnell—Structure-Con
Phone: (772)569-1257 File
Fax: (772)569=4041
www.mlengineeri nginc.com
r Pic 1
Units 320-720
Southeast elevation.
�P
Plc 2
sa Unit 520/620
Southeast edge repair.
-Grease cap placed.
�T, s -Guardrail to be re-anchored at repaired areas.
r
Pic 3
Unit 320/420
' Cable cut back from slab edge.