HomeMy WebLinkAboutEnergy CodeFORM R405-2017
i!
i
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 38 Block 1 Waterstone 1820 AGL
Builder Name: ADAMS HOMES
Street: 8600 Marano Avenue
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2120.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft'
b. Frame - Wood, Adjacent
R=13.0 270.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1820.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= 111:2
11. Ducts
R ft2
7. Windows(237.2 sqft.) Description Area
a. Sup: Attic, Ret:Main, AH:Main
6 364
a. U-Factor: Dbl, U=0.33 168.74 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.50
c. U-Factor: Dbl, U=0.33 18.33 ft2
SHGC: SHGC=0.31
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 17.78 ft2
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 4.055 ft.
Area Weighted Average SHGC: 0.269
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.130 Total Proposed Modified Loads: 64.56
PASS
Total Baseline Loads: 68.59
1 hereby certify that the plans and specifications covered by
Review of the plans and
IjBE S797
this calculation are in complia the Florida r
specifications covered by this
Code.
calculation indicates compliance
" __.•°
with the Florida Energy Code.
y�iir
E. nm • "%% -"'i'f „ 3 ;0
PREPARED BY:
Before construction is completed
r F C
DATE: 1-7-71770 Winn KPnmany
this building will be inspected for
compliance with Section 553.908
* ¢
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida de.
CDD WE
OWNER/AGE NT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPS
IM2020 4:31 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 38 Block 1 Waterstone 18 Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 38-1
Block/Subdivision: Waterstone
PlatBook:
Street: 8600 Merano Avenue
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockt
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfillD Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2 ___ 0.42 0 0.58
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emilt Emilt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft2 0.11 Woad
1/7/2020 4:31 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
t-UKM K4Ut)-ZUl /
IIVF'U I SUIVIMAKY GHtGKL151
KEPUKT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar
Below
1
NW
Exterior
Concrete Block- Int Insul
Main
4.1 59
0 10 0
590.0 ft.
0
0
0.6
0
2
SW
Exterior
Concrete Block - Int Insul
Main
4.1 20
0 10 0
200.0 ft'
0
0
0.6
0
_ 3
SE
Exterior
Concrete Block - Int Insul
Main
4.1 66
0 10 0
660.0 ft'
0
0
0.6
0
4
NE
Exterior
Concrete Block - Int Insul
Main
4.1 40
0 10 0
400.0 ft'
0
0.6
0
5
-
Garage
Frame - Wood
Main
13 27
0 10 0
270.0 ft'
0
0.23
0.01
0
DOORS
# Omt Door Type
1 SW Insulated
2 Wood
Wall
V #
Ornt
ID
Frame
Panes
1
NW
1
Vinyl
Low-E Double
2
NW
1
Vinyl
Low-E Double
3
SW
2
Vinyl
Low-E Double
4
SW
2
Vinyl
Low-E Double
5
SW
2
Vinyl
Low-E Double
6
SW
2
Vinyl
Low-E Double
7
SE
3
Vinyl
Low-E Double
8
NE
4
Vinyl
Low-E Double
9
NE
4
Vinyl
Low-E Double
10
NE
4
Vinyl
Low-E Double
# Floor Area Ceiling Ar
1 596 ft' 596 it'
Space
Storms
U-Value
Main
None
.25
Main
None
.25
WINDOWS
ation shown is the entered, Proposed
orientation.
NFRC
U-Factor SHGC
Imp
Area
Yes
0.33 0.23
N
6.9 ft'
Yes
0.33 0.23
N
48.6 ft'
Yes
0.33 0.31
N
5.0 ft'
Yes
0.33 0.21
N
16.2 ft'
Yes
0.33 0.21
N
16.2 ft'
Yes
0.33 0.31
N
13.3 ft'
Yes
0.33 0.23
N
48.6 ft'
Yes
0.55 0.7
N
17.8 ft' 1
Yes
0.33 0.23
N
32.4 ft'
Yes
0.33 0.23
N
32.4 ft'
GARAGE
ea
Exposed Wall Perimeter
Avg. Wall
64ft
8ft
INFILTRATION
Width Height Area
Ft In Ft In
3 6 8 20 ft'
2 8 6 8 17.8 ft'
Overhang
Depth Separatir
1 ft41n Oftl0in
1 ft4in Oftl0in
9ft0 in Oft6in
1 ft0in 3ft11 in
1 ft0in 5ft4in
9ft0in 2ft0 in
1 ft4in Oftl0in
1 ft10in Oft6in
1 ft4in Oft10in
11ft6in Oft6in
None
None
None
None
None
None
None
None
None
None
Wall Insulation
1
None
None
None
None
None
None
None
None
None
None
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000445
2123.3 116.57 219.22
.1685 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Block Ducts
1
Electric Heal Pump/
Split
HSPF:8.5
34.6 kBtu/hr 1 sys#1
1/7/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit(
Split
SEER: 15.5 35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft'
Main
91 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programabl[CoollnfeX1]Thermostat:
Ceiling Fans:
11Y Fe
VenattiDec
Jan Feb
ffX1]
Mar
ff 11
€
May Jun Jul
Aug
f[X11
Sep
(([ 11
Oct
Nov
f[X11
Nov
Dec
ng [ ] [ ]
[X]
[X] pr
]
[ ]
[X]
[X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
1/7/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
' 2017'EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
35.0
a) Split system SEER
15.5
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1820
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.346
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.269
14. Heating system: Capacity
34.6
c) Area
7c. 237.2
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. `NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy
Conservation, through the above energy
saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed
code compliant features.
Builder Signature ` -�
Date:
Address of New Home: 8600 Merano Avenue
City/FL Zip: Fort Pierce, FL 34951
1/7/2020 4:32:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1