Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 i! i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 38 Block 1 Waterstone 1820 AGL Builder Name: ADAMS HOMES Street: 8600 Marano Avenue Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2120.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft' b. Frame - Wood, Adjacent R=13.0 270.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1820.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= 111:2 11. Ducts R ft2 7. Windows(237.2 sqft.) Description Area a. Sup: Attic, Ret:Main, AH:Main 6 364 a. U-Factor: Dbl, U=0.33 168.74 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.33 18.33 ft2 SHGC: SHGC=0.31 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 17.78 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.055 ft. Area Weighted Average SHGC: 0.269 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1820.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.130 Total Proposed Modified Loads: 64.56 PASS Total Baseline Loads: 68.59 1 hereby certify that the plans and specifications covered by Review of the plans and IjBE S797 this calculation are in complia the Florida r specifications covered by this Code. calculation indicates compliance " __.•° with the Florida Energy Code. y�iir E. nm • "%% -"'i'f „ 3 ;0 PREPARED BY: Before construction is completed r F C DATE: 1-7-71770 Winn KPnmany this building will be inspected for compliance with Section 553.908 * ¢ I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida de. CDD WE OWNER/AGE NT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPS IM2020 4:31 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 38 Block 1 Waterstone 18 Bedrooms: 4 User Conditioned Area: 1820 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 38-1 Block/Subdivision: Waterstone PlatBook: Street: 8600 Merano Avenue County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockt 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfillD Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 ___ 0.42 0 0.58 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emilt Emilt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ft2 0.11 Woad 1/7/2020 4:31 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 t-UKM K4Ut)-ZUl / IIVF'U I SUIVIMAKY GHtGKL151 KEPUKT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NW Exterior Concrete Block- Int Insul Main 4.1 59 0 10 0 590.0 ft. 0 0 0.6 0 2 SW Exterior Concrete Block - Int Insul Main 4.1 20 0 10 0 200.0 ft' 0 0 0.6 0 _ 3 SE Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ft' 0 0 0.6 0 4 NE Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ft' 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ft' 0 0.23 0.01 0 DOORS # Omt Door Type 1 SW Insulated 2 Wood Wall V # Ornt ID Frame Panes 1 NW 1 Vinyl Low-E Double 2 NW 1 Vinyl Low-E Double 3 SW 2 Vinyl Low-E Double 4 SW 2 Vinyl Low-E Double 5 SW 2 Vinyl Low-E Double 6 SW 2 Vinyl Low-E Double 7 SE 3 Vinyl Low-E Double 8 NE 4 Vinyl Low-E Double 9 NE 4 Vinyl Low-E Double 10 NE 4 Vinyl Low-E Double # Floor Area Ceiling Ar 1 596 ft' 596 it' Space Storms U-Value Main None .25 Main None .25 WINDOWS ation shown is the entered, Proposed orientation. NFRC U-Factor SHGC Imp Area Yes 0.33 0.23 N 6.9 ft' Yes 0.33 0.23 N 48.6 ft' Yes 0.33 0.31 N 5.0 ft' Yes 0.33 0.21 N 16.2 ft' Yes 0.33 0.21 N 16.2 ft' Yes 0.33 0.31 N 13.3 ft' Yes 0.33 0.23 N 48.6 ft' Yes 0.55 0.7 N 17.8 ft' 1 Yes 0.33 0.23 N 32.4 ft' Yes 0.33 0.23 N 32.4 ft' GARAGE ea Exposed Wall Perimeter Avg. Wall 64ft 8ft INFILTRATION Width Height Area Ft In Ft In 3 6 8 20 ft' 2 8 6 8 17.8 ft' Overhang Depth Separatir 1 ft41n Oftl0in 1 ft4in Oftl0in 9ft0 in Oft6in 1 ft0in 3ft11 in 1 ft0in 5ft4in 9ft0in 2ft0 in 1 ft4in Oftl0in 1 ft10in Oft6in 1 ft4in Oft10in 11ft6in Oft6in None None None None None None None None None None Wall Insulation 1 None None None None None None None None None None # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2123.3 116.57 219.22 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heal Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 1/7/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit( Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft' Main 91 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabl[CoollnfeX1]Thermostat: Ceiling Fans: 11Y Fe VenattiDec Jan Feb ffX1] Mar ff 11 € May Jun Jul Aug f[X11 Sep (([ 11 Oct Nov f[X11 Nov Dec ng [ ] [ ] [X] [X] pr ] [ ] [X] [X] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 1/7/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 ' 2017'EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1820 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.346 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.269 14. Heating system: Capacity 34.6 c) Area 7c. 237.2 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. `NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature ` -� Date: Address of New Home: 8600 Merano Avenue City/FL Zip: Fort Pierce, FL 34951 1/7/2020 4:32:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1