Certification for Design Load Compliance
p Dave Golden S aracio e EB �61010
Project Name: — p ����
t do
Project Address: Wagon Wheel Ln coaqrb))ent
Permit #: Occupancy Type: R Construction TypeY
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Residential Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:_]X II _III IV Exposure Category: BX C _D
4. Design Wind Velocity L 60 mph 1 24 ASD LRFD End Zone Width:1.33 ft
5. Mean Roof Height<15 ft Roof Pitch:5 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4:+33.5 -36.3 Zone 5:+33.5 -44.8 Garage:
7. Design Loads: Floor: PSF Roof/Dead:? PSF Roof/Live:20 Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure?X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided?X YesNot Applicable Explain Why Not:
10. Design Soil Bearing Pressure:2,000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
�c0 -0 —'rJ o�S
Signature, Date, and Seal
Janet Dunlap
Print Name Cert # & Co. Cert Auth.
PE 62809
Residential Engineering Design CA32507
Company Name & Address
Revised 12/07/2018