Loading...
HomeMy WebLinkAboutCertificate for Design Load CompliancePlanning & Development Services Department 1\ • Building & Code Regulations Division• ---- — — 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance p Dave Golden S aracio e EB �61010 Project Name: — p ���� t do Project Address: Wagon Wheel Ln coaqrb))ent Permit #: Occupancy Type: R Construction TypeY INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_]X II _III IV Exposure Category: BX C _D 4. Design Wind Velocity L 60 mph 1 24 ASD LRFD End Zone Width:1.33 ft 5. Mean Roof Height<15 ft Roof Pitch:5 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4:+33.5 -36.3 Zone 5:+33.5 -44.8 Garage: 7. Design Loads: Floor: PSF Roof/Dead:? PSF Roof/Live:20 Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure?X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided?X YesNot Applicable Explain Why Not: 10. Design Soil Bearing Pressure:2,000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: �c0 -0 —'rJ o�S Signature, Date, and Seal Janet Dunlap Print Name Cert # & Co. Cert Auth. PE 62809 Residential Engineering Design CA32507 Company Name & Address Revised 12/07/2018