HomeMy WebLinkAboutEnergy Code{tECENEt'
FORM R405-2017 ER r e
'FLORIDA ENERGY EFFICIENC4 CODEJ;OR BUILDING
ttun�
Florida Department of Business and PrBf�s9aegulation - Residential
CONSTRUCTION
Performance Method
Project Name: SPARACIO RESIDENCE
Builder Name: DAVE GOLDEN HOMES
Street: 18001 WAGONWHEEL LANE
Permit Office: STLUCIECOUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner.
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3484.0 sqft.)
Insulation Area
2. Single family or multiple family Single-famiy
a. Concrete Block - Int Insul, Exterior
R=4.1 3024.00 ft2
b. Frame -Wood, Adjacent
R=11.0 340.00 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 120.00 fN
4. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (3501.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 3501.00 ft2
6. Conditioned floor area above grade(ft2) 3501
b. NIA
R= ft2
Conditioned floor area below grade (112) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(392.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 150
a. U-Factor. Sgl, U=0.58 272.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 125
SHGC: SHGC=0.24
b. U-Factor. Sgl, U=0.60 120.00 ft2
12. Cooling systems
kStu/hr Efficiency
SHGC: SHGC=0.24
a. Central Unit
35.2 SEER:16.00
b. Central Unit
24.0 SEER:16.00
c. U-Factor. NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. WA ft2
a. Electric Strip Heat
27.0 COPA.00
SHGC:
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 7.241 ft,
Area Weighted Average SHGC: 0.240
14. Hot water systems
a. Electric
Cap: SOgallon
8. Floor Types (3501.0 sgft.) Insulation Area
EF: 0.960
a. Slab -On -Grade Edge Insulation R=0.0 3501.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.112 Total Proposed Modified Loads: 109.15
PASS
Total Baseline
Loads: 109.77
I hereby certify that the plans and specifications covered by
Review of the plans and
F1IIEST4j
this calculation are in compliance with the Florida Energy
specifications covered by this
BYO AO
Code.
calculation indicates compliance
with the Florida Energy Code.
F rnn,'4; y.°0
PREP R BY'
DATE-
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this bull ' , as des cfn s in compliance
Florida Statutes.
9�
with the Florida Energy Co
GOD yyE igJ
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FL:cpp''
1110/202012:36 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) ComplidRI Software Pagel of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
SPARACIO RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned
Area:
3501
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
#of Units:
1
Worst Case:
No
PlatBoolc
Builder Name:
DAVE GOLDEN HOMES
Rotate Angle:
0
Street:
18001 WAGONWHEEL
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5%
2.5 h
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
2029
20618
2
AHU 2
1472
14930
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
HALL
64
640
No
0
1
No
Yes
Yes
2
CLST 1
28
280
No
0
1
No
Yes
Yes
3
BATH 1
70
700
No
0
1
No
Yes
Yes
4
BEDROOM 1
168
1680
No
0
1
1
Yes
Yes
Yes
5
BEDROOM 2
169
1690
No
0
1
1
Yes
Yes
Yes
6
FOYER
63
630
No
0
1
Yes
Yes
Yes
7
KITCHEN 2
455
4550
Yes
0
1
Yes
Yes
Yes
8
MASTER BEDROO
328
3608
No
0
1
1
Yes
Yes
Yes
9
M W IC 2
84
840
No
0
1
Yes
Yes
Yes
10
FAMILY ROOM
240
2400
No
0
1
Yes
Yes
Yes
11
M TOILET 2
18
180
No
0
1
Yes
Yes
Yes
12
CLST 2
26
260
No
0
1
Yes
Yes
Yes
13
M BATH 2
126
1260
No
0
1
Yes
Yes
Yes
14
DINING
165
1650
No
0
1
Yes
Yes
Yes
15
PANTRY
25
250
No
0
1
No
Yes
Yes
16
KITCHEN 1
200
2000
Yes
0
1
Yes
Yes
Yes
17
M BATH 1
168
1580
No
0
1
Yes
Yes
Yes
18
M W IC 1
42
420
No
0
1
No
Yes
Yes
19
M TOILET 1
24
240
No
0
1
Yes
Yes
Yes
20
MASTER BEDROO
210
2310
No
0
1
1
Yes
Yes
Yes
21
PARENT SPACE
434
4340
No
0
1
Yes
Yes
Yes
Ill 01202012:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 2 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number
Name Area Volume
Kitchen Occupants
Bedrooms
Infil ID Finished
Cooled
Heated
22
DEN 156
1560
No
0
1 Yes
Yes
Yes
23
PANTRY 1 16
160
No
0
1 Yes
Yes
Yes
24
LAUNDRY ROOM 232 2320
No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
HALL
1 ft
0
64 ft'
—
1
0
0
2SIab-On-Grade Edge Insulation
CLST 1
1 ft
0
28 ft'
—
1
0
0
3SIabOnGrade Edge Insulation
BATH 1
1 ft
0
70 ft'
_
1
0
0
4SIab-On-Grade Edge Insulation
BEDROOM 1
14 It
0
168 ft'
--
1
0
0
5SIab-OnGrade Edge Insulation
BEDROOM 2
18 ft
0
169 ft'
—
1
0
0
6SIabOnGrade Edge Insulation
FOYER
7 ft
0
63 ft'
__
1
0
0
78Iab-On-Grade Edge Insulation
KITCHEN 2
27 ft
0
455 ft'
__
1
0
0
SSIab-OnGrade Edge Insulation
MASTER BEDRO
35 ft
0
328 ft'
--
1
0
0
981ab-On-Grade Edge Insulation
M WIC 2
7 ft
0
84 ft'
—
1
0
0
1061ab-On-Grade Edge Insulation
FAMILY ROOM
15 ft
0
240 fP
—
1
0
0
11Slab-OnGmde Edge Insulation
M TOILET 2
9 ft
0
18 ft'
—
1
0
0
12SIab-On-Grade Edge Insulation
CLST 2
6 ft
0
26 ft'
-_
1
0
0
13SIab-OnGrade Edge Insulation
M BATH 2
16 It
0
126 ft'
—
1
0
0
14SIab-OnGrade Edge Insulation
DINING
22 ft
0
165 ft'
—
1
0
0
15SIabOnGrade Edge Insulation
PANTRY 2
1 It
0
25 ft'
1
0
0
1631ab-OnGrade Edge Insulation
KITCHEN 1
Sit
0
200 ft'
—
1
0
0
1751abOnGrade Edge Insulation
M BATH 1
24 ft
0
158 ft'
-_
1
0
0
18SIab-On-Grade Edge Insulation
M WIC 1
1 ft
0
42 ft'
__
1
0
0
1961abOnGrade Edge Insulation
M TOILET 1
6ft
0
24 ft'
—
1
0
0
2091abOnGrade Edge Insulation
MASTER BEDRO
29 ft
0
210 ft'
—
1
0
0
21SIab-OnGrade Edge Insulation
PARENT SPACE
28 ft
0
434 ft'
—
1
0
0
22SIabOnGrade Edge Insulation
DEN
12 it
0
156 ft'
_
1
0
0
23SIab-OnGrade Edge Insulation
PANTRY 1
4 ft
0
16 ft'
—
1
0
0
24SIab-OnGrade Edge Insulation
LAUNDRY ROOM
9ft
0
232 ft'
—
1
0
0
1/10202012:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ROOF
• /
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested Tested Insul.
(deg)
1
Hip Metal 3792 ft'
Oft'
Light
N
0.1
No 0.9
No 20
22.6
ATTIC
/
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
3501 ft-
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
HALL
0
Blown
64 R'
0.1
Wood
_
2
Under Attic(Unvented)
CLST1
0
Blown
28 ft'
0.1
Wood
3
Under Attic (Unvented)
BATH
0
Blown
70 ft'
0.1
Wood
4
Under Attic (Unvented)
BEDROOM 1
0
Blown
168 ft'
0.1
Wood
5
Under Attic (Unvented)
BEDROOM
0
Blown
169 ft'
0.1
Wood
_
6
Under Attic (Unvented)
FOYER
0
Blown
63 ft'
0.1
Wood
7
Under Attic (Unvented)
KITCHEN
0
Blown
455 ft'
0.1
Wood
8
Under Attic (Unvented)
MASTER BEDRO
0
Blown
328 ft'
0.1
Wood
9
Under Attic (Unvented)
MWIC2
0
Blown
84 ft'
0.1
Wood
10
Under Attic (Unvented)
FAMILY ROOM
0
Blown
240 ft'
0.1
Wood
_
11
Under Attic (Unvented)
MTOILET 2
0
Blown
18 ft'
0.1
Wood
_
12
Under Attic (Unvented)
CLST2
0
Blown
26 ft'
0.1
Wood
_
13
Under Attic (Unvented)
M BATH 2
0
Blown
126 ft-
0.1
Wood
_
14
Under Attic (Unvented)
DINING
0
Blown
165 ft'
0.1
Wood
_
15
Under Attic (Unvented)
PANTRY2
0
Blown
25 ft'
0.1
Wood
_
16
Under Attic(Unvented)
KITCHEN
0
Blown
200 ft'
0.1
Wood
17
Under Attic (Unvented)
M BATH 1
0
Blown
158 H'
0.1
Wood
18
Under Attic (Unvented)
M WIC 1
0
Blown
42 ft'
0.1
Wood
19
Under Attlo (Unvented)
M TOILET 1
0
Blown
24 ft'
0.1
Wood
_
20
Under Attic (Unvented)
MASTER BEDRO
0
Blown
210 W
0.1
Wood
21
Under Attic (Unvented)
PARENTSPACE
0
Blown
434 ft-
0.1
Wood
22
Under Attic (Unvented)
DEN
0
Blown
156 ft'
0.1
Wood
23
Under Attic (Unvented)
PANTRYI
0
Blown
16 ft'
0.1
Woad
24
Under Attic (Unvented)
LAUNDRY ROOM
0
Blown
232 ft'
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
_ 1
E
Garage Frame - Wood
CLST 1
11 2
0 10
0
20.0 ft-
0 0.1
0.1
0
2
E
Garage Frame -Wood
BATH1
11 5
0 10
0
50.0 ft'
0 0.1
0.1
0
_ 3
N
Exterior Concrete Block- Int InsuBEDROOM 1
4.1 14
0 10
0
140.0 ftf
0 0
0.1
0
4
E
Garage Frame -Wood
BEDROOMI
13 12
0 10
0
120.0 ft'
0 0.1
0.1
0
5
N
Exterior Concrete Block-
Int InsuBEDROOM 2
4.1 13
0 10
0
130.0 ft'
0 0
0.1
0
1/10/202012:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
-6
E
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1
5
0
10
0
50.0 ft'
0
0
0.1
0
_ 7
N
Exterior
Concrete Block- Int Insul FOYER
4.1
7
0
10
0
70.0 fP
0
0
0.1
0
8
E
Exterior
Concrete Block- Int Insul KITCHEN 2
4.1
9
0
10
0
90.0 ft2
0
0
0.1
0
-9
S
Exterior
Concrete Block- Int InsuIKITCHEN 2
4.1
18
0
10
0
180.0 ft'
0
0
0.1
0
_ 10
S
Exterior
Concrete Block- Int InsuMASTER BE
4.1
16
0
11
0
176.0 ft'
0
0
0.1
0
11
W
Exterior
Concrete Block- Int InsuMASTER BE
4.1
19
0
11
0
209.0 ft2
0
0
0.1
0
12
W
Exterior
Concrete Block- Int Insul M WIC 2
4.1
7
0
10
0
70.0 ft2
0
0
0.1
0
_ 13
S
Exterior
Concrete Block - Int InsuFAMILY ROO
4.1
15
0
10
0
150.0 R'
0
0
0.1
0
_ 14
N
Exterior
Concrete Block- Int InsulM TOILET 2
4.1
6
0
10
0
60.0 ft.
0
0
0.1
0
_ 15
W
Exterior
Concrete Block- Int InsulM TOILET 2
4.1
3
0
10
0
30.0 ft-
0
0
0.1
0
_ 16
N
Exterior
Concrete Block- Int Insul CLST 2
4.1
2
0
10
0
20.0 ft2
0
0
0.1
0
17
W
Exterior
Concrete Block- Int Insul CLST 2
4.1
4
0
10
0
40.0 ft2
0
0
0.1
0
18
N
Exterior
Concrete Block- Int Insul M BATH 2
4.1
10
0
10
0
100.0 ft2
0
0
0.1
0
_ 19
W
Exterior
Concrete Block- Int Insul M BATH 2
4.1
6
0
10
0
60.0 It.
0
0
0.1
0
20
N
Exterior
Concrete Block- Int Insul DINING
4.1
15
0
10
0
150.0 ft2
0
0
0.1
0
21
E
Exterior
Concrete Block- Int Insul DINING
4.1
4
0
10
0
40.0 ft2
0
0
0.1
0
22
W
Exterior
Concrete Block- Int Insul DINING
4.1
3
0
10
0
30.0 ft2
0
0
0.1
0
23
W
Exterior
Concrete Block- Int InsuIKITCHEN 1
4.1
8
0
10
0
80.0 ft2
0
0
0.1
0
_ 24
E
Exterior
Concrete Block - Int Insul M BATH 1
4.1
14
0
10
0
140.0 ft'
0
0
0.1
0
25
S
Exterior
Concrete Block- Int Insul M BATH 1
4.1
10
0
10
0
100.0 112
0
0
0.1
0
_ 26
5
Exterior
Concrete Block- Int InsulM TOILET 1
4.1
6
0
10
0
60.0 fF
0
0
0.1
0
27
S
Exterior
Concrete Block- Int InsuMASTER BE
4.1
15
0
11
0
165.0 ft2
0
0
0.1
0
28
W
Exterior
Concrete Block- Int InsuMASTER BE
4.1
14
0
11
0
154.0 ft2
0
0
0.1
0
29
E
Exterior
Concrete Block- Int InsdPARENT SPA
4.1
14
0
10
0
140.0 ft2
0
0
0.1
0
30
W
Exterior
Concrete Block- Int Inst1PARENT SPA
4.1
14
0
10
0
140.0 ft2
0
0
0.1
0
31
E
Exterior
Concrete Block- Int Insul DEN
4.1
12
0
10
0
120.0 ft2
0
0
0.1
0
32
N
Garage
Frame -Wood DEN
11
13
0
10
0
130.0 ft2
0
0.1
0.1
0
_ 33
W
Exterior
Concrete Block- Int Insul PANTRY 1
4.1
4
0
10
0
40.0 ft2
0
0
0.1
0
34
W
Exterior
Concrete Block- Int InsulAUNDRY R
4.1
9
0
10
0
90.0 ft2
0
0
0.1
0
35
E
Garage
Frame -Wood LAUNDRYR
11
14
0
10
0
140.0 ft2
0
0.1
0.1
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 3
Metal Low-E Single Yes
0.58
0.24
N
15.0 ft2
1 It 4In
1 it 7 in
None
None
2
N 5
Metal Low-E Single Yes
0.58
0.24
N
15.0 ft2
6 it 4 in
2 It 0In
None
None
3
N 7
Metal Low-E Single Yes
0.58
024
N
16.0 ft2
6 It 4 in
1 It 71n
None
None
_
4
N 7
Metal Low-E Single Yes
0.58
0.24
N
24.0 ft2
6 It 4 in
1 It 7 in
None
None
_
5
E 8
Metal Low-E Single Yes
0.58
0.24
N
12.0 ft2
1 It 4 in
1 It 7 in
None
None
6
S 9
Metal Low-E Single Yes
0.58
0.24
N
36.0 ft2
1 ft 4 in
1 ft 7 in
None
None
7
S 10
Metal Low-E Single Yes
0.58
0.24
N
15.0 ft2
1 it 4 in
1 It 7 in
None
None
8
W 11
Metal Low-E Single Yes
0.58
0.24
N
15.0 ft2
1 it 4 in
1 It 7 in
None
None
9
S 13
Metal Low-E Single Yes
0.6
0.24
N
60.0 ft2
15 it 4 in
2 It 0 in
None
None
1/10/2020 12:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC Sth Edition (2017) Compliant Software Page 5 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth Separation
Int Shade
Screening
10
N 18 Metal
Low-E Single
Yes
0.58 0.24 N
8.0 ft' 1 ft 4 in 2 ft 0 in
None
None
_ 11
W 19 Metal
Low-E Single
Yes
0.58 0.24 N
8.0 ft' 1 It 4 in 1 ft 7 in
None
None
12
N 20 Metal
Lav-E Single
Yes
0.58 0.24 N
15.0 fF 6 ft 4 in 2 ft 0 in
None
None
13
W 23 Metal
Low-E Single
Yes
0.58 0.24 N
9.0 ft- 15 ft 4 in 1 ft 71n
Drapes/blinds
Exterior 5
14
E 24 Metal
Low-E Single
Yes
0.58 0.24 N
9.0 ft' 1 ft 4 in 1 ft 7 in
Drapes/blinds
Exterior 5
_ 15
S 27 Metal
Low-E Single
Yes
0.58 0.24 N
16.0 ft- 1 ft 4 in 1 ft 7 in
None
None
16
W 28 Metal
Low-E Single
Yes
0.58 0.24 N
15.0 ft' 1 ft 4 in 1 ft 71n
None
None
17
E 29 Metal
Low-E Single
Yes
0.58 0.24 N
8.0 ft- 6 ft 4 in 1 ft 7 in
None
None
_ 18
E 29 Metal
Low-E Single
Yes
0.58 0.24 N
24.0 ft' 6 ft 4 in 1 ft 7 in
None
None
19
W 30 Metal
Lo E Single
Yes
0.6 0.24 N
60.0 ft' 15 ft 4 in 1 ft 7 in
None
None
20
E 31 Metal
Low-E Single
Yes
0.58 0.24 N
12.0 ft- 1 ft 4 in 1 ft 7 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
759 ft'
759 ft-
48 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgIA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000452
4147.3 227.68 428.18 .1722
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat!
None
COPA
27 kBtu/hr
1
sys#1
2
Electric Strip Heat!
None
COPA
17kBtu/hr
2
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
35.2 kBtu/hr 1056 cfm
0.8 1
sys#1
2
Central Unit/
Split
Single SEER: 16
24 kBtwbr 720 cfm
0.8 2
sys#2
HOT WATER SYSTEM
#
System Type
SubType
Lccagon
EF Cap
Use SelPnt
Conservation
1
Electric
None
Garage
0.98 50 gal 62.3 gal 120 deg
None
1/10202012:36 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model #
Area Volume
FEF
None None
ft2
DUCTS
/ —Supply—
— Return —
Air
CFM25 CFM25
HVAC#
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT OUT ON RLF
Heat Cool
1 Attic 6
150 ft2
Attic
105 ft2
Default Leakage
Attic
(Default) c(Default) c
1 1
2 Attic 6
125 ft2
Attic
13 ft-
Default Leakage
Attic
(Default) c(Default) c
2 2
TEMPERATURES
Programable[[Thermostat:
Ceiling Fans:
[ j�N
Heating [X] JDec
an [X] Feb
[[ j�
[X]
Mar
[
L
j
1r
May
[
Jun [� Jul
Xj
4 ]Aug
[X]
[ ]Sep
j[Xj�
OctOct
[[X]]
Venting [( 11 Jan [( ]1 Feb
[(�X]l
Mar
llxxll
j May
Jun j Jul
(] Aug
j ]
Sep [X]
Nov[
j Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
60
80
78 78
78
78
78 78
78
78
Heating (WD) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Defauft(8 lbs/sq.ft.
0 ft2
0 It
0.3
HALL
Defauft(8lbs/sq.ft.
ft2
It
0.3
CLST 1
Defauh(8lbs/sq.ft.
ftZ
It
0.3
BATH 1
Default(8 lbs/sq.ft.
ft2
It
0.3
BEDROOM 1
Default(8lbs/sq.ft.
IF
It
0.3
BEDROOM 2
Defauft(8lbs/sq.ft.
ft2
It
0.3
FOYER
Defauh(8lbs/sq.ft.
ft2
It
0.3
KITCHEN 2
Defauft(8lbs/sq.ft.
ft2
It
0.3
MASTER BEDROO
Defauft(8 Ibs/sq.ft.
ft2
It
0.3
M W IC 2
Defauf(8 lbs/sq.ft.
ft2
It
0.3
FAMILYROOM
Defauft(S Ibs/sq.ft.
fl2
It
0.3
M TOILET 2
Defauft(6lbs/sq.ft.
ft2
It
0.3
CLST 2
Defauft(6 lbs/sq.ft.
ft.
It
0.3
M BATH 2
Defauft(81bs/sq.ft.
ft2
It
0.3
DINING
Defauft(8lbs/sq.ft.
f2
It
0.3
PANTRY2
Defauft(8 lbs/sq.ft.
IF
It
0.3
KITCHEN 1
Defauh(8lbs/sq.ft.
fI2
It
0.3
M BATH 1
Defauft(B Ibs/sq.ft.
ft2
8
0.3
M W IC 1
Defauft(8 lbs/sq.ft.
ft2
It
0.3
M TOILET 1
1/10/202012:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FbRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thiclmess
Fumiture Fraction
Space
Defauft(B lbs/sq.ft.
fF
ft
0.3
MASTER BEDROO
Defauft(B lbs/sq.ft.
ft=
ft
0.3
PARENT SPACE
Defauft(8 lbs/sq.ft.
ft'
ft
0.3
DEN
Defauft(8 lbs/sq.ft.
ft'
ft
0.3
PANTRY 1
Defauft8lbs/s.ft.
ft.
ft
0.3
LAUNDRYROOM
1/10202012:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SPARACIO RESIDENCE Builder Name: DAVE GOLDEN HOMES
Street: 18001 WAGONWHEEL LANE Permit Office: STLUCIECOUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
Owner. Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be Insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed In substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall Include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity Insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind piping and wiring.
Shaver/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
Insulated.
ElectdcaUphone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/10/202012:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC Sth Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
59.2
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
3501
d) Room uniUPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.586
b) Solar Heat Gain Coefficient (SHGC)
71b.
0.240
14. Heating system: Capacity
44.0
c) Area
7c.
392.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
varies
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied ' h the Florida Building Code, Energy Conservation, through the above energy
saving features which w 11 be inst or
exceeded) in this home before final inspection. O hervdse, a new EPL
display card will be completed b s on installedpliant features.
Builder Signature: Date: Z
Address of New Home: 18001 WAGONWHEEL LANE City/FL Zip: FORT PIERCE. FL
1/10/202012:38:50 PM EnergyGauge® USA 6.0.04 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1