HomeMy WebLinkAboutTAMKO PNSProfessionalBusiness &
Regulation
K
BCIS Home Loy T. User Registration Hot Topics j Submit Surcharge Stats & Facts Publications FBC Staff 6CrS Site Map Links j Search
FI Cid3
a Product Approval
gg USER: Public User
ProductApproval Menu > Product orApplication Search > Application List > Application Detail
" FL # FL12328-118
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri_eden @ta m ko. oom
Authorized Signature Kerd Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Sox 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri_eden @tam ko. co m
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01107/2019
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.odF
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4869
2016
ASTM D6380
2003
TAS 103
1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated 10/19/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
12328.1
ASTM Slate Surfaced Roll Roofing
Roll roofing surfaced with mineral granules
Limits of Use
Installation instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE_ TBP14001.4 2017 FBC Fval Report TAMKO
Underlayments finai.pdf
Created by Independent Third Party: Yes
12329.2
ASTM Tile Underlayment
Coated organic underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 iI TBP1_4001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments fina1.pdf
Created by Independent Third Party: Yes
12328.3
Master Smooth
Asphalt saturated organic underlayment.
Limits of Use
Installation instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
F1-1232 R 11 TBP14001.4 2 17 FBC Eval Report TAMKO
Un erlayments €inai.odf
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Evai Report TAMKO
Underlavments final.pdf
Created by Independent Third Party: Yes
12328.4
Moisture Guard
A self -adhering modified bitumen underlayment.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL1 232B. RS 11 TBP14001.4 2017 FBC Eval Report TAMK
Underla m nts fin I. df
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure. N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Created by Independent Third Party: Yes
12328.5
No. 15 ASTM
Asphalt saturated organic felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 H TBP140Q1 4 2017 FBC Eval Report TAMKO
Underlavments finaLpdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12.328 RS AF TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.odf
Created by independent Third Party: Yes
12328.6
No. 15 UL
Asphalt saturated organic felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 H TBP14 01.4 ...7 FBC Eval Re ort TAMKO
Underlyments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final pdf
Created by Independent Third Party: Yes
12328.7
No. 30 ASTM
Asphalt saturated organic felt
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other. See evaluation report for limits of use.
Installation Instructions
FL12 28 RS II TBP140 1.4 2017 FBC Eval Report TAMK
Underlavments final.odf
Verified By: Zachary R. Priest 74021
Created by independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Created by Independent Third Party: Yes
12329.8
No. 30 UL
Asphalt saturated organic felt
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328 R8 II TBP14001.4 2017 FBC Eval Re ort TAMKO
Underlavments final df
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AF T8P140 1.4 2017 FBC Eval Re rtTAMK
Goderlayrnents final, df
Created by Independent Third Party: Yes
12328.9 TAM-FFLT
Alternate to ASTM D 225, Type II underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for fimits of use.
Installation Instructions
FL1232E3 R8 II TBP140DI.4 2017 F8C Eval Report TAMKO
Und rla m nts findl. df
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC FVAl Report TAMKO
Underlavments final pdf
Created by Independent Third Party: Yes
12328.10
TW Metal and Tile Underlayment
self -adhering modified bitumen underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328 R8 11 TBP14O01.4 2017 FBC Eval Report TAMKO
Underlavments final pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001A 2017 FBC Eval Report TAMKO
Underlayments final pdf
Created by Independent Third Party: Yes
12328.11
TW Underlayment
self -adhering modified bitumen underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure., N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328 R8 11 TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Verified By: Zachary R, Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAM KO
Underla ments final. df
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 elan Stone Roatl. Tallahassee FL 32399 Phone: 650-487-1824
The State of Florida is an AA/EEO employer. Wright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are Public records. if you do not want your e-mail address released in response to a public -records request, do not send electr is
mail to this entity. Instead, contact the office by phone or by traditional mall. if you have any questions, please contact 850.487.1395, *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personae address,
please provide the Department with an email address which can he made available to the public. To determine it you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
7101-1 ® eCh[ck
Certificate of Authorization No. 29824
CREEK17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 61" EDITION (2017)
Manufacturer:
TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417) 624-6644
htt ://www,tamko.00m
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1
Properties:
Physical properties
PRODUCT DESCRIPTION
TAMKOV ASTM Slate
ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing
with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKOO ASTM Tile
ASTM D 6380, Class M, Type I I underlayment constructed from an organic felt saturated
Underlayment
with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO® Master
ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
Smooth
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral, For
use in non-HVHZ only.
TAMKO® Moisture
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard®
with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKOQ No. 15 ASTM
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKOO No. 15 UL
ASTM D 226, Type [ underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® No. 30 ASTM
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® No. 30 UL
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® TW Metal and
Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment
with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO® TW
Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment
polymer film on the surface and a removable release Film on the adhesive side.
TBP14001.4 Fl 12328-R8 Page 1 of
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
SCREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKOO TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturers installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 118" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAMKOO TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKOV Moisture Guard® shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKO@ ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO® TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverinas:
Metal Roof
Mineral
Wood
Underlayment
Asphalt
Shingles
Panels and
Shingles
Surfaced Roll
Roofing
Shingles and
Slate
Clay and
TAMKOO ASTM Slate
Shakes
Shingles
Concrete Tile
Surfaced Roll Roofing
Y 1
N
N
N
N
Y
TAMKOQ ASTM Tile
Underlayment
N
N
N
N
N
Y
TAMKOO Master Smooth
Y1
N
N
N
N
N
TAMKO@) Moisture Guard®
Y
N
N
N
N
N
TAMKO@ No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Yz
N
N
Felt
TAMKO@ No. 15 UL Asphalt
Saturated Organic Felt
Y
Y
Y
YZ
Y
N
TAMKO@ No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
TAMKO® No. 30 UL Asphalt
Saturated Organic Felt
Y
Y
Y
N
Y
N
TAMKO(D TW Metal and Tile
Underlayment
Y
Y
N
N
N
Y
TAMKOO TW Underlayment
Y
Y
N
N
N
N
TAMKO@ TAM -FELT
Y
N
N
N
N
N
,.vma. i/ -pen valley applicabons per 150 .2.9.2
2) Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlaymenis
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
REFERENCES
Enti
PRI Construction Materials Technologies (TST6049)
Report No.
TAP-192-02-01
Standard
ASTM D 1970
Year
PRI Construction Materials Technologies (TST6049)
TAP-193-02-01
ASTM D 1970
2015a
2015a
PRI Construction Materials Technologies (TST6049)
TAP-214-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP-215-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP-216-02-03
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-217-02-01 REV
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-218-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP-219-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP-220-02-01
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-222-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP-245-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
TAP-311-02-01
ASTM D 4798
ASTM D 1970
2011
2015a
PRI Construction Materials Technologies (TST6049)
TAP-319-02-01.1
ACC 188
2012
PRI Construction Materials Technologies (TST6049)
TAP-387-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-388-02-01
ASTM D 1970
2015a
UL LLC (TST9628)
13CAI2269
ASTM D 226
2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Undertayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
���Ilk�rlrr�r
:�tiPG •� %C'•E•N SF.
No 74021
,13• STATE OF •ZIJ�
CERTIFICATION OF INDEPENDENCE
2017.10.19
12:15:58
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, }_LC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, afinancial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.