Loading...
HomeMy WebLinkAboutDesign pressure calcsR M License # CGC1519801 4047 Okeechobee Blvd, Ste 106, West Palm Beach FL 33409 S- M A RT Phone (561) 229-0048 of Southeast Florida Property Information Owner: Marcelle Aptheker Address: 10791 Grey Heron Court Port Saint Lucie, FL 34986 Building Information Wind Zone: 160 MPH. Exposure Category: D Minimum Building Dimension: 5 ft. Mean Roof Height: 18 ft. Risk Category: II Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1 Design Pressure Calculations Opening Location Device Device Device Positive Max Negative Number Zone Width (in) Height (in) IF—Max Elevation (ft) Pressure (psf) Pressure (psf) 4 Int 74 63 7 38.7 -42.3 5 Int 37 63 _ 7 40.6 44.2 6 Int 37 63 7 40.6 _44.2 _ Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1