Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HORBACZ AND MOORE RESIDENCE Builder Name: DAVE GOLDEN HOMES Street: 492 CONLEY PLACE Pem OfriCe: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1550.0 sqft.) Insulation Area 2. Singfefarrdly or muitiplefaurify Single-family a. Concrete Block - Ext Ir--ul, Exterior R=4.1 1290.00 ft' b. Frame - Wood, Adjacent R=11.0 260.00 fN 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1451.0 sgft.) Insulation Area 5. Is this a wore: case? No a. Roof Deck (Urrvented) R=20.0 1451.00 ft2 6. Conditioned floor area above grade (ft2) 1451 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(138.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 125 a. U-Factor. Sgl, U=0.33 73.33 ft2 SHGC: SHGC=0.26 I b. U-Factor. Sgl, U=0.31 64.83 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a. Central Unit 24.0 SEER:16.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 9.389 ft. Acres Weighted Average -SHGC: 0.269 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1451.0 sqft.) Insulation Area EF: 0.990 I a. Slah-On-Grade Edge Insulation R=0.0 1451_00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.095 Total Proposed Modified Loads: 48.78 PASS Total Baseline Loads: 49.59 1 hereby certify that the plans and specifications covered by Review of the plans and FTRE ST,17 this calculation are in compliance with the Florida Energy specifications covered by this ♦2� Code. calculation indicates compliance h the Florida Energy Code. en„ .; •`,}€:°`..�°, O PREPA D BY: DATE: efore construction is completed this building will be inspected for compliance with Section 553.908 94 A . a e I hereby certify that this building desig to compliance Florida Statutes. GOO J with the Florida Energy Code. WME OWNER/AGENT' BUILDING OFFICIAL: DATE: DATE: :r- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/122020 5:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HORBACZ AND MOORE RE Bedrooms: 2 Address Type: Street Address Build!". Ty,`F' I kg� Area: 1151 Lot 4 Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatSook: Builder Name: DAVE GOLDEN HOMES Rotate Angle: 0 Street: 492 CONLEY PLACE Permit Office: ST LUCIE COUNTY Cross Venllation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1451 14510 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 276 2760 No 0 1 1 Yes Yes Yes 2 M WIC i 35 350 No 0 i Yes Yes 'res 3 M W IC 2 36 360 No 0 1 No Yes Yes 4 M BATH 158 1580 No 0 1 Yes Yes Yes 5 KITCHEN 242 2420 Yes 0 1 Yes Yes Yes 6 GREAT ROOM 378 3780 No 0 1 Yes Yes Yes 7 LAUNDRY 77 770 No 0 1 Yes Yes Yes R RRAT.".7 66 660 Ne. n 1 No yes Yes I9 CLST 2 14 140 No 0 1 No Yes Yes 10 BEDROOM2 151 1510 No 0 1 1 Yes Yes Yes 11 MTOILET 18 180 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 32 ft 0 I 276 ft- — 1 0 0 2Slab-OnGrade Edge Insulation M WIC 1 eft 0 35 ft- — 1 0 0 3SIab-OnGrade Edge Insulation M WIC 2 1 ft 0 36 W — 1 0 0 4SIab-OnGrade Edge Insulation M BATH 21 It 0 158 ft' — 1 0 0 _ 5SIab-OnGrade Edge Insulation KITCHEN 22 It 0 242 IF — 1 0 0 I6SIab-OnGrede Edge Insulation GREAT ROOM 18 ft 0 378 ft- — 1 0 0 3/12/20205:12 PM EnergyGauge® USA 6.0.02 (Rev. 1)- RaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS If Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet ZS�.yti�l�,Css e.E5k7@!S? i9:?i641 L..AUMMY 7ft 4 77 ft= _ 1 0 0 8SIab-On-Grade Edge Insulation BATH 2 1 It 0 66 ft' - 1 0 0 I 9SIab-On-Grade Edge Insulation CLST 2 1 ft 0 14 ft' - 1 0 D 103Iab-On-Grade Edge Insulation BEDROOM 2 17 ft 0 151 ft' - 1 0 0 11SIab-On-Grade Edge Insulation M TOILET E ft 0 18 fF _ 1 0 0 ROOF Roof Gable Roof Red Solar SA Emih Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1572 ft' Oft' Light N 0.3 No 0.9 No 20 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1451 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under LHi,(i •n:pn'ea) SiaSTEc BEfI[Jr1 n RIm:T. 27a e2 0.1 Wood 2 Under Attic(Urwented) MWIC1 0 Blown 35 ft' 0.1 Wood I 3 Under Attic (Unvenied) M WIC 2 0 Blown 36 ft' 0.1 Wood 4 Under Attic (Unvented) M BATH 0 Blown 158 ft' 0.1 Wood 5 Under Attic(Unvented) KITCHEN 0 Blown 242 ft' 0.1 Wood 6 Under Attic(Unvented) GREAT ROOM 0 Blown 378 ftr 0.1 Wood 7 Under Attic(Unvented) LAUNDRY 0 Blown 77 ft' 0.1 Wood 8 'under Attic (Unvenied) BAT H 2 0 Blown 66 F 0.1 Wood 9 Under Attic(Unvented) CLST2 0 Blown 14 ftr 0.1 Wood i _ 10 Under Attic (Unvented) BEDROOM 2 0 Blown 151 It. 0.1 Wood 11 Under Attic(Unvented) MTOILET 0 Blown 18 ft' 0.1 Wood WALLS Adjacent Space Cavdy Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block- Ext InsdiIASTER BE 4.1 16 0 10 0 160.0 ft' 0 0 0.3 0 _ 2 E Exterior Concrete Block- Ext InsdMPSTEP. BE 4.1 16 0 10 0 1en- o ft' 0 0 0.3 0 _ 3 N Exterior Concrete Block - Ext Insul M WIC 1 4.1 6 0 10 0 60.0 ft' 0 0 0.3 0 4 N Exterior Concrete Block- Ext Insul M BATH 4.1 11 0 10 0 110.0 ft' 0 0 0.3 0 _ 5 W Exterior Concrete Block- Ext Insul M BATH 4.1 10 0 10 0 100.0 R' 0 0 0.3 0 6 E Exterior Concrete Block- Ext Insul KITCHEN 4.1 22 0 10 0 220.0 ft' 0 0 0.3 0 7 ::' Ext=-. Conc^ic Bl =k Ext1re,.GREX17 ROO 4.1 13 0 10 0 4.80.0 ft' 0 0 OS 0 I = 8 E Exterior Concrete Block- Ext lnsull-AUNDRY 4.1 7 0 10 0 70.0 fi= 0 0 0.3 0 I 3/12120205:12 PM EnergyGauge(D USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 9 S Garage Frame -Wood LAUNDRY 11 11 0 10 0 110.0 ft' 0 0.2 0.3 0 _ 10 S Garage Frame - Wood BATH 2 11 6 0 10 0 60.0 ft' 0 0.2 0.3 0 _ 11 S Garage Frame - Wood CLST 2 11 2 0 10 0 20.0 ft- 0 0.2 0.3 0 _ 12 S Exterior Concrete Block- Ext InsiBEDROOM 2 4.1 6 0 10 0 60.0 ft. 0 0 0.3 0 _ 13 W Exterior Concrete Block- Ext Ins0EDROOM 2 4.1 11 0 10 0 110.0 ft' 0 0 0.3 0 14 S Garage Frame -Wood BEDROOM 11 7 0 10 0 70.0 ft' 0 0.2 0.3 0 15 W Exterior Concrete Block- Ext InsulM TOILET 4.1 6 0 10 0 60.0 ft- 0 0 0.3 0 WINDOWS Orienta ion shown Is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.31 0.26 N 15.0 ft' 1 It 4 in 2It 0 in None None 2 E 2 Vinyl Low-E Single Yes 0.31 0.28 N 5.4 ft- 13 It 4 in 1 ft 6 in None None 3 W 5 Vin•,4 Low-E Single Yes 0.31 0.28 N 2.7 ft- 1 ft 4 in 3 ft 0 in None None 4 E 6 Vinyl Low-E Single Yes 0.31 0.28 N 9.0 ft- 13 it 4 in 1 ft 6 in None None 5 E 6 Vnyl Low-E Single Yes 0.33 0.26 N 53.3 ft' 13 ft 4 in 2 ft 0 in None None 6 W 7 Vinyl Low-E Single Yes 0.31 0.26 N 15.0 ft' 7 ft 4 in 2 ft 0 in None None _ 7 W 7 Vinyl Low-E Single Yes 0.33 0.26 N 20.0 ft' 7 ft 4 in 2 ft 0 in None None _ 8 W 13 Vinyl Low-E Single Yes 0.31 0.28 N 15.0 ft- 7 It 4 in 2 ft 0 in None None 9 W 15 Vinyl Low-E Single Yes 0.31 0.28 N 2.7 ft- 1 ft 4 in 3 ft 0 in None None GARAGE Fluor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall insulation 1 1456 R2 1456 fP 26 It , loft 11 INFILTRATION Scope M-hod Sal CFM. so EL&. EgLA ACH, ACLi54 1 Wholehouse Proposed ACH(50) .000445 1692.8 92.93 174.78 .1685 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 COOJ_JNQ SYSTE .. # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 3/12/2020 5:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Ebwtna Twkb Ga13w 059. tga6 :Fa.1 gad 1%4 deg t"( SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Locolon Arca Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft- Attic 13 ft- Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooking frXT� Tan (r)(T) reb Heating p(7()�Mar r Apr tf May l[if`vtrn [[ �1rf Jul X`Aug Aug 4i(11 Sep act �x1�Wv Oct Nov `rx,�uec Venting [ ] Jan [ ] Feb [XJ Mar Apr (1 May [ Jun [ [ [XJ [ I Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 55 65 65 65 55 68 68 68 68 58 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(B lbs/sq.ft. O ft- Oft 0.3 MASTER BEDROO Default(Blbs/sq.ft. fF` ft 0.5 MWIC 1" Defaut(81bs/sq.ft. fP ft 0.3 MWIC2 Default(81bs/sq.ft. ft' ft 0.3 M BATH Defauft(81bs/sq.ft. ft' ft 0.3 KITCHEN Defauft(81bs/sq.ft. fP ft 0.3 GREAT ROOM Defauft(8lbs/sq.ft. ft- ft 0.3 LAUNDRY Defauft(8 lbs/sq.ft. fP ft 0.3 BATH 2 Defauft(81bs/sq.ft. w ft 0.3 CLST 2 Defauft(8 lbs/sq.ft. ft- ft 0.3 BEDROOM 2 I Defauft(6 lbs/sq.ft. fF ft 0.3 M TOILET 3/12/2020 5:12 PM EnergyGaug& USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HORBACZ AND MOORE RESIDENCE Builder Name: DAVE GOLDEN HOMES Street: 492 CONLEY PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner. Jurisdiction: ST LUCIE COUNTY W x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit stall be aligned with the The insulation In any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop doom stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed ridge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bofforr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, ufility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed In the building be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring a plumbing In exterior walls, or insulation that on Installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. ElectricaVphone box on The air barrier shall be installed behind electrical or communication exteriorw ells boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that Is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and wells or ceilings. a. In addition, inspection of log wells shall be in accordance with the provisions of ICC-4DD. 3112/20205:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 24.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1451 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.321 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.269 14. Heating system: Capacity 17.0 c) Area 7c. 138.2 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.99 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatReO/o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has com ied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be' sailed r exceeded) in this home before final inspection. Otherwise, a new EPL display card will be comple based n i tailed code compliant features. Builder Signature: ! Date: 3a114 Address of New Home: 492 CONLEY PLACE City/FL Zip: FORT PIERCE. FL 3/12/2020 5:13:02 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1