HomeMy WebLinkAboutCertificate for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982- (772) 462-1553
(�� G/�, nCerrtificatiio 1n for Design Load Compliance
Project Name: t Y(�I' —ckC�-V�1�,OV�\C` ' ,��V",�1\,.IS/ 1I. �n
Project Address: "l U JO V_nOIk BMX! �--lA ,—)
Permit
Type:S r _ Construction
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:_I X II _III_IV Exposure Category:_B X C _D
4. Design Wind Velocity 160 mph X ASO LRFD End Zone Width: 6 ft
5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings)
Zone 1: +19.9 -11.7 Zone 2: +19.9 -55.1 Zone 3: +19.9 -81.5 Zone 4: +34.6 -37.5 Zone 5: +34.6 46.3 Garage: +28.5 -34.8
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
B. Were Shear Walls Considered For Structure?_Yes X Not Applicable Explain Why Not:
Aspect Ratio <4:1
9. Is A Continuous Load Path Provided? X Yes NotApplicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify'that struct I elements depicted on these plans provide adequate resistance to the design
forces tied:
Donald J. Nuelle P.E. 52046
` Print Name Cert # & Co. Cert Auth.
g Zp Nuelle Engineering
gnature, Date,/nd eal 11634 S.W. Rowena Street, Port St. Lucie 34987
Company Name & Address
Revised 12/07/2018