HomeMy WebLinkAboutCompaction Test - Chaloux, JHeadquarters Il' CA 1 lin t ENGINEERING U S. Highway 1 PO Box78-113777 Sebastian, FL. 32958 Sebastian, FL- 32 Z%v LJ jri AND TESTING Orlando hone: 772589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: April 29, 2020 KSM JOB #: 201859-2d/SH/ct PERMIT #: 2002-0102 NUC # 528 CONTRACTOR: Brett Webster Tractor Nuc Model: MC -10R -P JOB LOCATION: 5405 Deer Run Drive Nuc Serial #: MD049528 Holiay Pines Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill -1st & 2nd Lift Retest TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C,F) COMPACTION 1. S.W. 0" - 12" 40 107.0 108.9 98.3% 2. Center 40 107.3 98.5% 3. N. E. 41 108.1 99.3% 4. S.W. 12" - 24" 41 108.0 99.2% S. Center 42 108.8 99.9% 6. N.E. 42 108.6 99.7% Soil Description: Brown Sand with traces 110.0 I I I I 1 of Shell e I I I I I In Place Moisture: I I 11.0% 109.0 —••_lI .._.. .._. �_.._� G r ...___......___ Optimum Moisture: TProctor 12.0% 108.0 -4II— P ill Proctor Max. Dry Density: P.C.F. 108.9 107.0 —.••.__. @ Test Locations the Density & F Penetrometer readings indicate the I 106.0=—•._.I._..J.._..1.._..I_.._l._.._ Degree of Compaction Meets I I I I I I Minimum Requirement D 1 for Unstaked Foundation R I I I I I �—.._.�._...�.._..*..._. Y 105.0 ..—�.—..� Respectfully Submitte 9 10 11 12 13 14 15 t%rr lurri rs Moisture - % of Dry Weight EN5� ; Disclaimer: Contractor is responsible to maintain Q' zCD OC= the tested area in the condition that KSM completed the indicated passed compaction test. = pTE OF Uj zKSM is not responsible if the tested area has been RIOReOP C4 altered from the approved inspected condition. � Stf BryanSE�rd�liHi�� P.E. V.P. of Engineering PE # 81439 4/30/2020 Email to: St Lucie County Building Department; brett.webster@yahoo.com Proudly Serving Florida since 1990