Loading...
HomeMy WebLinkAboutProduct ApprovalBCIS Home Floridapr rF Product Public Approval USER: Public User File CGa_dm= Product Approval Menu > Product or Application Search > Application List > Application History > Applhcatlon Detail FL # FL13192=R2 BCIS Site Map Application Type Revision Code Version 2010 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed the POC and/or the Commission if necessary. Comments RECEIVED Archived O APR 15 2020 Product Manufacturer Permitting Department James Hardie Building Products, Inc. Address/Phone/Email St. Lucle County 26300 La Alameda Ste. 250 Mission Viejo, CA 92691 '(909)545-8359 chad.diercks@jameshardie.com Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Chad. Diercks , chad.diercks@jameshardle.com Chad Diercks 10901 Elm Ave Fontana, CA 92337 I9091356-6366 chad.diercks@jameshaQe.COIp��A1�D` pNC� Chad Diercks f► [�pE GONIGOVNTY 10901 Elm Ave ,C909) 356 6366 Fontana, CA 37 600G chad.diercks@jameshardie.com Panel Walls Siding Evaluation Report from a Florida Registered Architect or a L Professional Engineer ® Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Ronald I. Ogawa Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA, Inc. Quality Assurance Contract Expiration Date 01/01/2016 . Validated By John Southard, P.E. ® Validation Checklist - Hardcopy Received https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...S6JDHeshB3ROgigDMzdaObpWGyxKWytvxOdRb4p6hp0g%3d%3d 4/9/20, 7:27 AM Page 1 of 3 Certificate of Independence El 13192 R2 COI RIO - Certificate of Independence.PDF Referenced Standard and Year (of Standard) Standard Year ASTM C1186 2007 ASTM E330 2002 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Method 1 Option D 12/15/2011 12/16/2011 12/26/2011 01/31/2012 04/23/2015 Summary, of.Products FL'#-: Model, Number or Name ° Description { ` 13192.1 Cemplank Lap Siding fiber -cement lap siding Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use in HVHZ install in accordance with NOA 07- 0418.04. ' Installation Instructions FL13192 R2 II ER RIO-2298-11 Plank Shingle FL13192 2 II ER RIO-2300-11 Plank metal w FL13192 R2 II Install - cemolank.pdf FL13192 R2 II NOA 07-041804.odf Verified By: Intertek Testing. Services NA Ltd. Created by Independent Third Party: No Evaluation Reports FL13192 R2 AE Dade NOA 07-041804.odf FL13192 R2J�E ER RIO-2298-11 Plank Shingle FL13192 R2 AE ER RIO-2300-11 Plank metal t Created by Independent Third Party: Yes 13192i2 ,, :.-" HartliePlank Lap Siding fiber -Cement lap Siding ° `L'mitsofUse _ .° Approved for,use in-HVHZ: Yes ° _ ,. "Approved for use outside HVHZ: Yes 'Impact Resistant:N/A -- • ,,, '" - ,Design Pressure:N/A, - Other: For use in HVHZinstallin,accordance with.NOA:07- 0418.04. - '` ... - - = _ Installation Instructions FL13192_132_1LER RIO-2298-11 Plank Shingle' FL13192 R2 II ER RIO-2300-11 Plank metal w FL13192 R2'II Install- hardiepIpank W, FL13192 R2. II NOA07-041804:odf•. Verified By: Intertek Testing, Services NA Ltd. Created by Independent Third'Partyi No Evaluation Reports „FL13192 R2 AE bade NOA-07-041804'.gd( FL13122 R2 AE 'ER RIO-2298-11 Plank Shingle FL13192 R2 SAE ER Rio-2300-11 Plank metal i •,Created•by;Independent Third Party:'Yes,.: 13192.3 HardieShingle Individual Shingles fiber -cement individual cladding shingles Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL13192 R2 II ER RIO-2299-11 Shingle metal FL13192 R2 II Install - new hardieshingle.pdf Verified By: Intertek Testing Services NA Ltd. Created by Independent Third Party: No Evaluation Reports FL13192 R2 AE ER RIO-2299-11 Shingle meta https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEV... S6JDHeshB3ROgigDMzdaObpWGyxKWytvxOdRb4p6hp0g%3d%3d 4/9/20, 7:27 AM Page 2 of 3 Created by Independent Third Party: Yes 13192.4 ., .,.. HardieShingle Panel,- - .. fber-cementnotched shingle panels (straight ad edge, half `round edge)- i :Limits of Use �- `' - - "' Approved for,use in HVHZ: No - Approved,for use outside HVHZ: Yes " ' Impact. Resistant:,N/A �. , ... Design Pressure: N/A - - - 'Other; - - .. « ... - .. .. dnstallation;Instructions `- 'FL13162 R2 II ER RIO-2298-11 Plank Shingle' FL13192 R2 I ER RIO-2299-11 Shingle"metal FL13192_82_LI Install - new hardieshingle.pff VerifiedBy:. Intertek Testing Services NA Ltd. =Created by Independent Third' Party: No. i Evaluation Reports FL13192 -R2 AE ER RIO-2296-11 Plank Shingle FL13192 B2 AE ER RIO-2299-11 Shingle meta Created by Independent Third. Party:_ Yes I 13192.5 1 Prevail Lap Siding fiber -cement lap siding Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL13192 R2 II ER RIO-2298-11 Plank Shingle FL1319 R22 II ER RIO-2300-11 Plank metal w FL13192 R2 II Install - prevail lap.pd Verified By: Intertek Testing Services NA Ltd. Created by Independent Third Party: No Evaluation Reports FL13192, R2 AE; ER RIO-2298-11 Plank Shincl FL13192 R2 AE ER RIO-2300-11 Plank metal t Created by Independent Third Party: Yes Back 'Ne Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Coovrieht 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: &e Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records req electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487. Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi' If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine under Chapter 455, F.S., please click here . Product Approval Accepts: 09A®''tryM secu rit)ai t.�nucs https://www.floridabuilding.org/pr/pr-app_dti.aspx?param=wGEV ... S6JDHeshB3ROgigDMzdaObpWGyxKWytvxOdRb4p6hp0g%3d%3d 419120, 7:27 AM Page 3 of 3 Florida Product Approval HardiePlank° Lap Siding • For use inside HVHZ: o HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 15- , 0122.04. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, o HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2553-15 or RIO-2557-15. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. HardiePlank® /y � >9 Lap Siding ®JamesHardie r EFFECTIVE SEPTEMBER 2013 1W INSTALLATION REQUIREMENTS - PRIMED & COLORPLUS11 PRODUCTS Vsltwww.lameshamie.com fortfie most recent version. SELECT CEDARMILL° • SMOOTH � CUSTOM COLONIAL"' SMOOTH • CUSTOM COLONIAL"' ROUGHSAWN CUSTOM BEADED CEDARMIW • CUSTOM BEADED SMOOTH • STRAIGHT -EDGE SHINGLE PLANK IMPORTANT FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEADTO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOIDTHE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THATYOU ARE USING THE CORRECT HARDIEZONE'" PRODUCT INSTRUCTIONS. INSTALLATION OF HZ103 PRODUCTS OUTSIDEAN HZ10E) LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONET" APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 (866 9HARDIE) STORAGE & HANDLING: Store flat and keep dry and covered prior © CUTTINI OUTDOORS to installation. Installing siding wet or 1. Poston cutting station so that wind wall blow dust away from user saturated may result in shrinkage at butt and others In walking area 2 Use one of the following metlods joints. Carry planks on edge. Protect a Best: I. Scone and snap edges and comers from breakage. James li. Shears(nmral, ele;trt a pnatnatc) Hardie is not responsible for damage b. Balm I. Dust reducing circular saw equipped with caused by Improper storage and handling HardeVade• sawblafe and HPA vacuum e#reficr of the predict c.0md: 1. Dust reducing circular sawwim a Har6eBladesaw t (mly use for low la mocha@ aping) INSTRUCTIONS INDWRS 1. Cut only using score and snap, or shears (manual, electric or pneumatic). 2.Position coding station in well -ventilated area - NEVER use a power saw indoors NEVER use acircular saw blade that does not carry the Ha dieBade saw bladetradenark NEVER dry sweep —Use wet suppression or HEPA Vacuum Mpcdat Note For re dnun protection (lowest respiable dust producbm), James Hadie recommends always usiog"Best°-betel cutfhg methods where feasible. to hutherneduce dust gxsms. Acidillorol Mom information ism -We GENERAL REQUIREMENTS: • HardiePlank• lap siding can be installed over braced wood or steel studs spaced a maximum of 24" D.C. or directly to minimum 7/16" thick OSB sheathing. See general fastening requirements. Irregularities in framing and sheathing can mirror through the finished application. • Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www. iameharde com • A water -resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap• Weather Barrier, a non -woven non -perforated housewrap', which complies with building code requirements. • When installing James Hardie products all clearance details in figs. 3-14 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6" in the first 10'. Figure 1 Double Wall sin le wall • Do not use HardiePlank lap siding in fascia or trim applications. construction construction • Do not install James Hardie products, such that they may remain in contact with standing water. water-resisRae bander let -In bracing • HardiePlank lap siding may be installed on flat vertical wall applications only. plywood or 24^ o.c. ran, • For larger projects, including commercial and multi -family projects, where the span of the osasheaming wall is significant in length, the designer andfor architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin "Expansion Characteristics of James Hardie® Siding Products" at www.JamesHardie.com. • DO NOT use stain, cil/alkyd base paint, or powder coating on James Hardie® Products. INSTALLATION: JOINTTREATMENT Figure2 Nara line (g nab One or more of the following joint treatment options line Is not are required by code (as refere iced 2009IRC stud present place R703.3.2) fastener A. Joint Flashing (James Hardie recommender!) between 314" afer- & 1, from tap w B. Caulking' (Caulking is not recommended sere Nab°corm of plank) for ColorPlus for aesthetic reasons as the �arner edge of pads Caulking and ColorPlus will weather Nlmve =differently. For the same reason,barrdo not caulk nail heads on 1eColorPlus products.) Harde�Plaaneseiding o o fastener C."H"jointer cover U"°mstaga11/4'stanerstdpto insta0 Platks in o ensure a crosatem plankangle m�erare mmactatbubfonk appmprbte gap between planks and trim, then caulk. — Note'. Feld painting over caulk rg may produce a sheen difference when compared to the field painted PrlmePlus. 'Refer to Caulking section in these instructions. ' For additional information on HardieWrap Weather Barrier, consult James Hardie at 1-866-4Hardie or www.hardiewTap.com WARNING: AVOID BREATHING SILICA DUST James Hardio® products contain respirable crystalline sifca, which Is known tome State of California to muse cancer and is cauidered by ARC and NOSH to be a cause of canter from same occupational sources. Breathing amesshe amounts of respirable slip dust can also rouse a disabfng and Potentially fatal lung disease called silicosis, and has beat linked with otter diseases. Some studies smoact our HS11119-P1f4 6113 y W OR CLEARANCE AND FLASHING REQUIREMENTS Figure 3 Figure 4 Figure 5 Roof to Wall Horizontal Flashing Kickout Flashing t. Y4" not Figure 7 Figure 8 Deck to Wall Ground to Siding Figure 6 Slabs, Path, Steps to Siding wired. code. Y1'". Ate, .✓..' %t .in Figure 9 Figure 10 Gutter to Siding Sheltered'Areas �yMV4ashin Mi A -2" •_i Q 6 r f1 -n(a Min. Sh„ Figure 12 Drip Edge Figure 14 Valley/Shingle Extension Figure 11 Mortar/Masonry FASTENER REQUIREMENTS * Blind Nailing is the preferred method of installation for HardiePlanks lap siding products. Face nailing should only be used where required by code for high wind areas and must not be used in conjunction with Blind nailing (Please see JHTech bulletin 17 for exemption when doing a repair). Pin -backed comers may be done for aesthetic purposes Only. Pin -backs shall be done with finish nails only, and are not a substitute for blind or face nairing. BLIND NAILING Nails -Wood Framing • Siding nail (0.09" shank x 0.221" HD x 2" long) • 11 ga. roofing nail (0.121 " shank x 0.371" HD x 1.25" long) Screws - Steel Framing • Ribbed Wafer -head or equivalent (No. 8 x 1 1/4" long x 0.375" HD) Screws must penetrate 3 threads into metal framing. Nails -Steel Framing • ET & F Panelfast• nails or equivalent (0.10" shank x 0.313" HD x 1-1/2" long) Nails must penetrate minimum 1/4" into metal framing. OSB minimum 7/16" • 11ga. roofing nail (0.121" shankx 0.371" HD x 1.75" long) • Ribbed Wafer -head or equivalent (No. 8 x 1 5/8" long x 0.375" HD). 0.em. 1 1!4'min. Overlap FACE NAILING Nails- Wood Framing • 6d (0.113" shank x 0.267" HD x 2" long) • Siding nail (0.09" shankx 0.221" HD x 2" long) Screws - Steel Framing • Ribbed Bugle -head or equivalent (No. 8-18 x 1-5/8" long x 0.323" HD) Screws must penetrate 3 threads into metal framing. Nails - Steel Framing • Er & F pin or equivalent (0.10" shankx 0.25" HD x 1-1/2" long) Nails must penetrate minimum 1/4" Into metal framing. OSB minimum 7116" • Siding nail (0.09" shankx 0.221" HD x 1-1/2" long)' Figure 15 1 Figure 16 Minimum overlap for Both Face and Blind Nailing me• BYntl Nat min: t 114° avedap } Wa rResisliw Barter s4° — O.C. maz. 1 114" min. overlap water-n:sistive barter Laminate sheet to be removed immediately after installation of each course for ColorPlusO products. When face ailing to OSB, planks must be no greater titan 91/4" wide and fasteners must be 12" o.c. or less. Also see General Fastening Requireme=; and when considering alternative fastening options refer to James Fiarde's Technical Bulletin JSTB 17 - Fastening Tips for HardePlane Lap Siding. HS11119-P214 6/13 A 1 ; GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Elecbo-gahanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -ripped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie* products near the ocean, large bodies of water, br in very humid climates. PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding.A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer- Does not apply for installation to steel framing). Manufacturers ofACQ and CA preservative-trealed wood recommend spacer materials or other physical barriers to prevent direct contact of ACO or CA preservative -treated wood and aluminum products. Fasteners used to attach ® ® countersunk HardieTrim Tabs to preservative -treated wood shall be of hot dipped fill & add Pali zinc -coated galvanized steel or stainless steel ar�d in accordance to 2009IRC snug flush DO NOT DO NOT R317.3 or 20091BC 2304.9.5. I FgureA Figure under drive nails staple • Consult applicable product evaluation or listinhq for correct fasteners type and placement to achieve specked design wind loads. PAINTING • NOTE Published wind loads may not be applicable to all areas where Local I DO NOT use stain, oiValkyd base paint, or powder coating on James Hardie® Building Codes have specific jurisdiction. Cor�.ult James Hardie Technical Products. James Hardie products must be paimed within 180 days for primed Services if you are unsure of applicable compliance documentation. product and 90 days for unprimed.100% acrylic topcoats are recommended. • Drive fasteners perpendicular to siding and framing. Do not paint when wet. For application rates refer to paint manufacturers • Fastener heads should fit snug against siding (no airspace). (fig. A) specifications. Back -rolling is recommended if the siding is sprayed. • Do not over -drive nail heads or drive nails at an angle. • If nail is countersunk, fill nail hole and add a nail. (fig. B) CUT EDGE TREATMENT • For wood framing, under driven nails should be hit flush to the plank with a Caulk, paint or prime all field cut edges. James Hardie touch-up kits are hammer (For steel framing, remove and replace Palo. required to touch-up ColorPlus products. • NOTE: Whenever structural member is present, HardiePlank should be fastened with even spacing to the structural rtiember. The tables allowing CAULKING direct to OSB or plywood should only be used when traditional framing is for best results use an Elastomeric Joint Sealant complying with ASTM C920 not available. Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM • Do not use aluminum fasteners, staples, orI clipped head nails. C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad as well as some other caulking manufacturers do not allow tooling. COLORPLUS® TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE • Care should be taken when handling and cutting James Hard eS ColorPlus® products. During installation use a wet soft cloth or soft brush to gentry wipe off any residue or construction dust left on the product,�then rinse with a garden hose. • Touch up nicks, scrapes and nail heads using the ColorPluse Technology touch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardiePlank® lap siding with ColorPlus Technology. • Laminate sheet must be removedimmediately after installation of each course. • Terminate non -factory cut edges into trim where possible, and caulk Color matched caulks are available from your ColorPluV product dealer. • Treat all other non -factory cut edges using the ColorPlusTechnology edge coaters, available from your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINTING JAMES HARDIE" SIDING AND TRIM PRODUCTS WITH COLORPLUS® TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: • Ensure the surface is clean, dry, and free of any dust, dirt, or mildew • %priming is normally not necessary • 100% acrylic topcoats are recommended • DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. • Apply finish coat In accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature • DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus torch -up section HS11119-P3r4 6/13 COVERAGE CHARTIESTIMATING GUIDE Number of 12' planks, does not include waste COVERAGE AREA LESS OPENINGS HARDIEPLANIC LAP SIDING WIDTH SQ 5114 6114 7114 712 8 8114 91/4 9112 12 (1 stl=loosgft.) (exposure) 4 5 6 6114 6314 7 8 8114 10314 1 25 20 17 16 15 14 13 13 9 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 44 43 38 38 28 4 100 80 67 64 59 57 50 50 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 95 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 12B 119 114 100 too 74 9 225 180 150 144 133 129 113 113 B4 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 217 208 193 186 163 163 121 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 200 200 149 W 425 340 283 272 262 243 213 213 158 18 450 360 300 288 267 257 .225 225 167 19 475 380 317 304 281 271. 238 238 177 20 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide.Actual usage is subject to variables such as building design. James Hardie does not assume responsibility for over or under ordering of product. IRECOGNITION; In accordame with IMES Evaluation Report ESR-2290, HardiePlenk@lap sidling is recognized as a witade alternate to thatspecified Inc the 2006,2009,620121rdemational Residential Code for Orre- and Two,Family Daellugs, and the 2006,2009,8,2012Inamatwnal Building Code,.. HardePlank lap siding is also recognoed feapplicabm in the fbdowire. CityufLosAngeles Research Report No. 2485Z State of Floddalisting FLil669, Dade County, FI nda NOANo. 02-072902,U.S.Dept of HUD Materials Release 1263c, Texas Depamrem of Insurance Prodct EvalmbonEC-23,GlyofNew YorkMEA223.93-M, and Califinen DSA PA-019. These documents should also be consulted for additional information cmceming the suitability of this product for spedncapplicebom. @2013James HardleBudding Products. All rightsmserved. Addltlonal Installation Information, James SM, and @denotetrademarks orregisforedredtrademof James Hardie ie Technology Li Lited.Fi isaregistered trademark Warranties, and Warnings are available at JamesHardle of James Technology Limited, WWW.fameSflardle.COm Panetfast Is registered trademark of ETBF Fastening Systems, Inc. H811119-P4(4 6113