Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Gen specs
16/20/22 W INCLUDES: • True Power— Electrical Technology • Two Line LCD Multilingual Digital Evolution- Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 5 for Details. • Electronic Governor • Standard Wi-Fi" Remote Monitoring • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Diredt-To-Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18" (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https:llassels.swri.org//ibrafyl'DifecloryOlListedProducis/ Constructionlndustry/973_DoC_204_ 13204-01-01_P,ev9. pdf GENERAC® GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-1, GO07037-1 (Aluminum - Bisque) -16 kVV GO Hz Model G007035-1 (Aluminurn - Bisque) - 16 kW 60 Hz Models GO07035-1. GO07038-1 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-2, GOD7O42-2 (Aluminum - Bisque) - 22 kW 60 Hz GENERAL` (;(SN LISTED Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. FEATURES-�---�LL__-- O INNOVATIVE ENGINE DESIGN & RtGOROUS TEST; NG are at the heart of Generac's C success in providing the most reliable generators possible. Generac's G -Force engine lineup offers added peace of mind and reliability for when you need it the most. The G -Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. G TRUE POURER7' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave C form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads, to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. TEST 'CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are PROTOTYPE TESTED NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. MOBILE LINK" REMOTE MONITORING. FREE with every Guardian Series Home G E N E R A C s _ standby generator. Allows you to monitor the status of your generator from anywhere in the '°s world using a smartphone, tablet, or PC. Easily access information such as the current I PROMISE O operating status and maintenance alerts. Connect your account to your authorized service dealer for fast, friendly and proactive service. With Mobile Link, you are taken rare of before the next power outage. GENERAL' 16/20/22 kW features and benefits tng,.-? Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Regulates the output voltage to ±1 % prevents damaging voltage spikes. For your safety. • Generac G -Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly • rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine Mounts near your existing distribution panel for simple, low-cost installation. life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. • Revolving field • Skewed stator • Displaced phase excitation • Automatic voltage regulation • UL 2200 listed Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Regulates the output voltage to ±1 % prevents damaging voltage spikes. For your safety. a ransfer awItch (11 a1*pilcable) . • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of five (5) seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. U l€ • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" (457 mm) away from a building. GENERAL` 16/20/22 kW features and benefits ��i�lt�ito�s Sys,�rn • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Remote FOO' itT ri g • Ability to view generator status Monitor your generator via your smartphone, tablet, or computer at any time via the Mobile Link application for • Ability to view generator Exercise/Run and Total Hours • Ability to view generator maintenance information • Monthly report with previous month's activity. • Ability to view generator battery information • Weather information complete peace of mind Review the generator's complete protection profile for exercise hours and total hours Provides maintenance information for your specific model generator when scheduled maintenance is due Detailed monthly reports provide historical generator information Built in battery diagnostics displaying current state of the battery Provides detailed local ambient weather conditions for generator location "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' Ma)dmum kilovoh amps and current are subject to and limited by such factors as fuel Btudnegajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease atxurtl percent for each 6 T (10 *0 above 16 T (60,T) 16/20/22 k W specifications Model G007035-1, G007036-1, G007038-1, G007039-1 G007042-2, G007043-2 6007037-1 (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (LP) 16,000 Watts` 20,000 Watts' 22,000 Watts' Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,000 Watts' 19,500 Watts ' Rated Voltage 240 240 240 Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 66.7/66.7 83.3/75.0 91.7/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 70 Amp 90 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight (Ib/kg) 409/186 448/203 466/211 Dimensions (L x W x H) it /mm 48 x 25 x 29 /1218 x 638 x 732 Sound output in dB(A) at 23 It (7 m) with generator operating at normal load— 67 67 67 Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test'" low -speed exercise mode" 55 55 57 Exercise duration 5 min 5 min 5 min Type of Engine GENERAC G -Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid -slate w/ Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 VDC 12 VDC 12 VDC Oil Capacity Including Filter Approx. 1.9 qt / 1.8 L Approx. 1.9 qt / 1.8 L Approx 1.9 qt/ 1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas fla/hr (ma/hr) 1/2 Load 218(6.17) 204 (5.78) 228 (6.46) Full Load 309 (8.75) 301 (8.52) 327 (9.26) Liquid Propane ON (gal/hr) [Vhr] 1/2 Load 74 (2.03) [7.70] 87 (2.37) [8.99] 92 (2.53) [9.57] Full Load 107 (2.94) [11.11] 130 (3.56) [13.48] 142 (3.90) [14.77] Note: Fuel pipe must be sized for full load. Required fuel ppressure to generator fuel inlet at all load ranges - 3.5-7° water column (7-13 mm mercury) for natural gas, 10-12" water column (19-22 mm mercury) for LP gas. For BTU content, multiply ft N x 2500 (LP) or ft'/hr x 1000 (NG). For Megajoule content, multiply ms/hr x 93.15 (LP) or m3/hr x 37.26 (NG) ys?T`',i3�g Two -Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode BuOons:Aulo Automatic Start on Utility failure. 7 day exerciser. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Off Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) From 140-171 V/1 90-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard RurVAlarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Gil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' Ma)dmum kilovoh amps and current are subject to and limited by such factors as fuel Btudnegajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease atxurtl percent for each 6 T (10 *0 above 16 T (60,T) GENERAC` 16/20/22 kW switch options 3fLi, v <l z' H `,V6 Model G007036-1 (16kW) • 16 space, 24 circuit, breakers not included. No. of Poles 2 • Current Rating (Amps) 100 • Electrically operated, mechanically -held contacts for fast, positive Voltage Rating (VAC) 120/240, 10 connections Utility Voltage Monitor (Fixed)' • • Rated for all classes of load, 100% equipment rated, both inductive and -Pick-up 80% resistive. -Dropout 65% • 2 -pole, 250 VAC Contactors. Return to Utility' approx. 15 sec • 30 millisecond transfer time. Exercises bi-weekly for 5 minutes' Standard • Dual coil design. UL Listed Standard • Rated for both copper and aluminum conductors. Total Circuits Available 24 • Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem Breaker capabilities 8 tandems • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor Circuit Breaker Protected Available RMS Symmetrical 10,000 mounting flexibility. Fault current @ 250 Volts 22,000 • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from *Function of Evolution Controller Lug Range Siemens, Murray, Eaton and Square D for the most flexible and cost effective Exercise can be set to weekly or monthly Main contacts are silver plated or silver alloy to resist welding and sticking. install. • Dimensions Height Width Depth H1 H2 Wi W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 DEPTH S,rv:�a R&BE, 8-9'a l et a `aaw;"as Model G007037-1 (16 kW)/G007039-1 (20 kW)/ • Includes Digital Power Management Technology standard (DPM). 0007043-2 (22 kW) • Intelligently manages up to four air conditioner loads with no additional No. of Poles Current Rating (Amps) 2 200 hardware. Voltage Rating (VAC) 120/240,19 • Up to four more large (240 VAC) loads can be managed when used in Utility Voltage Monitor (Fixed)' conjunction with Smart Management Modules (SMMs). -Pick-up -Dropout 80% 65% • Electrically operated, mechanically -held contacts for fast, clean connections. Return to Utility` approx 13 sec • Rated for all classes of load, 100%equipment rated, both inductive and resis- Exercises bi-weeldy for 5 minutes` standard five. UL Listed Standard • 2 -pole, 250 VAC contactors. Enclosure Type NEMA/UL 3R • Service equipment rated, dual coil design. Circuit Breaker Protected 22,000 • Rated for both aluminum and copper conductors. Lug Range 250 MGM - #6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution Controller • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mount- Exercise can be set to weekly or monthly ing flexibility. Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width Depth H1 H2 w1 W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0;,, 175.4. ♦ . 1 16/20/22 kW available accessories Model # Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon - G007005 -0 Wi-Fi LP Fuel Level Monitor Boring the LP tank's fuel level is an important step in making sure your generator is ready t0 run during an unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT SIDE VIEW l+eZ w FRONT VIEW Model Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet G005819-0 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPact®). G007036-1 The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below G007101-0 Battery Pad Warmer 0 IF (-18 °C). (Not necessary for use with AGM -style batteries). G007038-1 Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0 IF G007102-0 Oil Warmer (-18 °C). G007042-2 The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers G007103-1 Breather Warmer only in climates where heavy icing occurs. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621-0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a Base Wrap Kit Fascia Bas a p K G007027-0 - Bisque sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting (Standard 22 holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch up a generator enclosure. Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine G006485-0 Scheduled Maintenance Kit maintenance on a Generac automatic standby generator. Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its G006873-0 Smart Management Module power management capabilities. It provides additional power management flexibility notfound in any other (50 Amps) power management system. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT SIDE VIEW l+eZ w FRONT VIEW Model UPC 0007035-1 696471074161 G007036-1 696471074154 G007037-1 696471074178 G007038-1 696471074185 G007039-1 696471074192 G007042-2 696471074208 0007043-2 696471074215 G E N E RAC Generac Power Systems, Inc, • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com - 0911111111"---- _-- ©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change wnhout notice. Part No. 100000001 94-H (8/01/18)