HomeMy WebLinkAboutEnergy Code7
!' FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential PYFfo"gtMVPood--
Project Name: Adams Homes - 2320 Model - 8505 Waterstone
Builder Name: Adams Homes
FEB 19 2020
Street: 8505 Waterstone Boulevard
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
ST. Lucie County, Permitting
Owner: Adams Homes - 2320 Model
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1900.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1700.20 ft2
b. Frame - Wood, Adjacent
R=11.0 200.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2332.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2332.00 ft2
6. Conditioned floor area above grade (ft2) 2332
b. N/A
R= ft2
Conditioned floor area below grade (ft� 0
c. N/A
R= ft2
11. Ducts
R ft'
7. Windows(238.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU
6 105
a. U-Factor: Sgl, U=0.33 166.03 ft'
SHGC: SHGC=0.23
b. U-Factor: Sgl, U=0.33 72.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
40.0 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
40.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.224
14. Hot water systems
8. Floor Types (2332.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallonsEF:
a. Slab -On -Grade Edge Insulation R=0.0 2332.00 ft2
b. Conservation features
0.950
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF. Pstat
Total Proposed Modified Loads: 71.91
Glass/Floor Area: 0.102
PASS
Total Baseline Loads: 72.49
I hereby certify that the plans and specifications covered by
Review of the plans and
STgl�
this calculation are in compliance with the Florida Energy
specifications covered by this
oF'fA$
y
Code.
calculation indicates compliance
�O
with the Florida Energy Code.
nnr "," °� i ;;•`°,
PREPARED BY:
Before construction is completed
,`
DATE: 12-18-19
this building will be inspected for'"a
compliance with Section 553.908
a
* ,
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
�.
with the Florida EnSay Code.C'Op
yyfi'tt�vy
OWNER/AGFNT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th EditionFR pro ey Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Adams Homes - 2320 Model -
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2332
Lot #
Owner Name:
Adams Homes - 2320 Model
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Adams Homes
Rotate Angle:
0
Street:
8505 Waterstone
Soule
Permit Office:
St. Lucie County
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan:
No
City, State,
Zip:
Fort Pierce ,
Family Type:
Single-family
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Inl Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2332
20612.6
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfI ID
Finished Cooled
Heated
1
Bedroom 4
175
1400 No
1
1
1
Yes
Yes
Yes
2
Bath
60
480 No
0
1
Yes
Yes
Yes
3
Hall
118
944 No
0
1
Yes
Yes
Yes
4
Bedroom 3
151
1208 No
1
1
1
Yes
Yes
Yes
5
Bedroom 2
210
1680 No
1
1
1
Yes
Yes
Yes
6
Family Room
338
3447.6 No
2
1
Yes
Yes
Yes
7
Foyer
72
720 No
0
1
Yes
Yes
Yes
8
Dining Room
182
1820 No
2
1
Yes
Yes
Yes
9
Breakfast Nook
146
1357.8 No
2
1
Yes
Yes
Yes
10
Kitchen
224
2307.2 Yes
2
1
No
Yes
Yes
11
Laundry
96
768 No
0
1
No
Yes
Yes
12
AHU
18
144 No
0
1
No
Yes
Yes
13
WIC
63
504 No
0
1
Yes
Yes
Yes
14
Master Bath
108
864 No
0
1
Yes
Yes
Yes
15
Master Bedroom
255
2040 No
2
1
1
Yes
Yes
Yes
16
Toilet
24
192 No
0
1
Yes
Yes
Yes
17
Hall
92
736 No
0
1
No
Yes
Yes
12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
- FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpel
1 Slab -On -Grade Edge Insulatio
Bedroom 4
28 ft
175 ft2
1
0
0
2 Slab -On -Grade Edge Insulatio
Bath
6 ft
60 ft2
___
1
0
0
3 Slab -On -Grade Edge Insulatio
Hall 2
1 ft
118 ft2
—
1
0
0
4 Slab -On -Grade Edge Insulatio
Bedroom 3
16 ft
151 ft2
__
1
0
0
5 Slab -On -Grade Edge Insulatio
Bedroom 2
44 ft
210 ft2
___
1
0
0
6 Slab -On -Grade Edge Insulatio
Family Room
13 ft
338 ft2
_
1
0
0
7 Slab -On -Grade Edge Insulatio
Foyer
8 ft
72 ft2
1
0
0
8 Slab -On -Grade Edge Insulatio
Dining Room
18 ft
182 ft2
___
1
0
0
9 Slab -On -Grade Edge Insulatio
Breakfast Nook
20.9 It
146 ft2
—
1
0
0
10Slab-0n-Grade Edge Insulatio
Kitchen
1 ft
224 ft2
_-
1
0
0
11SIab-On-Grade Edge Insulatio
Laundry
1 ft
96 ft2
___
1
0
0
12SIab-On-Grade Edge Insulatio
AHU
1 ft
18 ft2
_
1
0
0
13SIab-On-Grade Edge Insulatio
WIC
7 ft
63 ft2
_
1
0
0
14SIab-On-Grade Edge Insulatio
Master Bath
6 ft
108 ft2
____
1
0
0
15SIab-On-Grade Edge Insulatio
Master Bedroom
32 ft
255 ft2
_
1
0
0
16SIab-On-Grade Edge Insulatio
Toilet
6 ft
24 ft2
_
1
0
0
178Iab-On-Grade Edge Insulatio
Hall 1
1 ft
92 ft2
___
1
0
0
ROOF
_ /
Roof
Gable Roof
Red
Solar SA Emift
Emift
Deck
Pilch
V
# Type Materials Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2608 ft2
0 ft2 Medium
N
0.6 No 0.9
No
0
26.6
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
300 2332 ft2
N N
12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Bedroom 4
30
Batt
175 ft'
0.1
Wood
2
Under Attic (Vented) Bath
30
Batt
60 ft'
0.1
Wood
3
Under Attic (Vented) Hall
30
Ball
118 ft2
0.1
Wood
4
Under Attic (Vented) Bedroom 3
30
Batt
151 ft'
0.1
Wood
5
Under Attic (Vented) Bedroom 2
30
Batt
210 ft'
0.1
Wood
6
Under Attic (Vented) Family Room
30
Batt
338 ft'
0
Wood
7
Under Attic (Vented) Foyer
30
Batt
72 ft'
0.1
Wood
8
Under Attic (Vented) Dining Room
30
Batt
182 ft'
0.1
Wood
9
Under Attic (Vented) Breakfast Nook
30
Batt
62 ft'
0.1
Wood
10
Under Attic (Vented) Breakfast Nook
30
Batt
84 ft2
0
Wood
11
Under Attic (Vented) Kitchen
30
Batt
224 ft'
0
Wood
12
Under Attic (Vented) Laundry
30
Batt
96 ft'
0.1
Wood
13
Under Attic (Vented) AHU
30
Batt
18 ft'
0.1
Wood
14
Under Attic (Vented) WIC
30
Batt
63 ft'
0.1
Wood
15
Under Attic (Vented) Master Bath
30
Batt
108 ft'
0.1
Wood
16
Under Attic (Vented) Master Bedroom
30
Batt
255 ft'
0.1
Wood
17
Under Attic (Vented) Toilet
30
Batt
24 ft'
0.1
Wood
18
Under Attic (Vented) Hall 1
30
Batt
92 ft'
0.1
Wood
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing Solar
Below
_ 1
N
Exterior Concrete Block - Ext InstBedroom 4
4.1
14
0 8
0
112.0 ft'
0
0
0.6
0
_ 2
W
Exterior Concrete Block - Ext InstBedroom 4
4.1
14
0 8
0
112.0 ft'
0
0
0.6
0
_ 3
W
Exterior Concrete Block - Ext Insul Bath
4.1
6
0 8
0
48.0 ft'
0
0
0.6
0
_ 4
E
Exterior Concrete Block - Ed Insul Hall 2
4.1
1
0 8
0
8.0 ft2
0
0
0.6
0
_ 5
W
Exterior Concrete Block- Ext InstBedroom 3
4.1
16
0 8
0
128.0 ft2
0
0
0.6
0
_ 6
E
Exterior Concrete Block - Ext Inst8edroom 2
4.1
15
0 8
0
120.0 ft'
0
0
0.6
0
_ 7
S
Exterior Concrete Block - Ext InstBedroom 2
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
_ 8
W
Exterior Concrete Block - Ext InsdIedroom 2
4.1
15
0 8
0
120.0 ft'
0
0
0.6
0
_ 9
N
Exterior Concrete Block - Ext ImItAmily Room
4.1
10
2 10
3
104.2 ft2
0
0
0.6
0
_ 10
S
Exterior Concrete Block - Ed Insul Foyer
4.1
8
0 10
0
80.0 ft2
0
0
0.6
0
_ 11
S
Exterior Concrete Block - Ext In501ning Room
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
_ 12
W
Exterior Concrete Block - Ed InsiDining Room
4.1
5
0 10
0
50.0 ft'
0
0
0.6
0
_ 13
N
Exterior Concrete Block - Ext InsWeakfast No
4.1
5
2 9
4
48.2 ft2
0
0
0.6
0
_ 14
NE
Exterior Concrete Block - Ext Indideakfast No
4.1
3
10 9
4
35.8 ft2
0
0
0.6
0
_ 15
E
Exterior Concrete Block - Ext Ins&eakfast No
4.1
2
7 9
4
24.1 ft'
0
0
0.6
0
_ 16
W
Exterior Concrete Block - Ed InsWeakfast No
4.1
2
7 9
4
24.1 ft'
0
0
0.6
0
17
NW
Exterior Concrete Block - Ext InsWeakfast No
4.1
3
10 9
4
35.8 ft2
0
0
0.6
0
18
E
Exterior Concrete Block- ExtInsul WIC
4.1
7
0 8
0
56.0 ft2
0
0
0.6
0
_ 19
E
Exterior Concrete Block - Ed InsMaster Bath
4.1
6
0 8
0
48.0 ft2
0
0
0.6
0
20
N
Exterior Concrete Block - Ext Indd9ster Bedro
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
_21
E
Exterior Concrete Block - Ext Inddkster Bedro
4.1
17
0 8
0
136.0 ft'
0
0
0.6
0
22
E
Exterior Concrete Block - Ext Insul Toilet
4.1
6
0 8
0
48.0 ft'
0
0
0.6
0
12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
23 E
Garage
Frame - Wood
WIC
11 9
8
72.0 ft2
0.23 0.6
0
_ 24 E
Garage
Frame
- Wood
Laundry
11 12
8
96.0 ft'
0.23 0.6
0
25 N
Garage
Frame - Wood
Dining Room 11 4
8
32.0 ft'
0.23 0.6
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
_ 1
N
Wood
Family Room
None
.39
2
10
6 10
19.4 ft'
2
S
Wood
Foyer
None
.39
3
6 10
20.5 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Vinyl
Low-E Single
Yes
0.33 0.23
N
15.0 ft'
2 ft 0 in
0 ft 7 in
None
None
2
W
5
Vinyl
Low-E Single
Yes
0.33 0.23
N
15.0 ft'
2 ft 0 in
0 ft 7 in
None
None
3
S
7
Vinyl
Low-E Single
Yes
0.33 0.21
N
30.0 ft'
2 ft 0 in
4 ft 5 in
None
None
4
N
9
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 112
2 ft 0 in
0 ft 7 in
None
None
5
S
10
Vinyl
Low-E Single
Yes
0.33 0.23
N
10.0 ft'
2 it 0 in
1 ft 4 in
None
None
6
S
10
Vinyl
Low-E Single
Yes
0.33 0.23
N
13.7 ft'
2 it 0 in
1 ft 4 in
None
None
7
S
11
Vinyl
Low-E Single
Yes
0.33 0.21
N
12.0 ft2
2 it 0 in
1 ft 0 in
None
None
8
S
11
Vinyl
Low-E Single
Yes
0.33 0.21
N
30.0 ft2
2 ft 0 in
1 ft 0 in
None
None
9
N
13
Vinyl
Low-E Single
Yes
0.33 0.23
N
20.0 ft2
2 ft 0 in
0 ft 7 in
None
None
10
NE
14
Vinyl
Low-E Single
Yes
0.33 0.23
N
8.7 ft2
2 ft 0 in
0 ft 7 in
None
None
11
NW
17
Vinyl
Low-E Single
Yes
0.33 0.23
N
8.7 ft2
2 ft 0 in
0 ft 7 in
None
None
_ 12
N
21
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft2
2 ft 0 in
0 It 7 in
None
None
13
E
22
Vinyl
Low-E Single
Yes
0.33 0.23
N
15.0 ft2
2 it 0 in
0 ft 7In
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
462 ft2
462 ft2
25 ft
8 it
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000393
2404.8 132.02
248.28
.1418
7
12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 5 of 7
- FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.2
40 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit'
Split
SEER: 14.5 40 kBtu/hr
cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SelPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ff'
DUCTS
/ — Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heal Cool
1 Attic 6 105 ft'
Attic
25 ft' Default Leakage
AHU
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
(rX
fr
rr Nov
rr
Venting Jan Feb MaDec
r
f Apr
May Jun ri Jul
Aug
4
Sep
�X�
Oct
Nov
lXl [ lnl
X� [
[
[x�
[x�
[Xi
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM 66
66 fib
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
Bedroom 4
Default(8 lbs/sq.ft.
ft'
ft
0.3
Bath
Default(8 lbs/sq.ft.
ft'
ft
0.3
Hall
Default(8 Ibs/sq.ft.
ft'
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft'
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
Family Room
Default(8 lbs/sq.ft.
ft'
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft'
ft
0.3
Dining Room
Default(8 Ibs/sq.ft.
ft'
ft
0.3
Breakfast Nook
Default(8 lbs/sq.ft.
ft'
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft'
ft
0.3
Laundry
Default(8 lbs/sq.ft.,
ft'
ft
0.3
AHU
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft'
ft
0.3
Master Bath
Default(8 lbs/sq.ft.
ft'
ft
0.3
Master Bedroom
Default(8 lbs/sq.ft.
ft'
ft
0.3
Toilet
Default 8 Ibs/s .ft.
ft'
ft
0.3
Hall 1
12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts,.. location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
AHU
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
40.0
a) Split system SEER
14.5
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2332
d) Room'uniVPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.330
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.224
14. Heating system: Capacity
40.0
c) Area
7c. 238.0
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081. 11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before
final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
i
Builder Signature
Date:
Address of New Home: 8505 Waterstone Boulevard
City/FL Zip: Fort Pierce, FL 34951
12/18/2019 2:12:22 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Adams Homes - 2320 Model - 8505 Waterston Builder Name: Adams Homes
Street: 8505 Waterstone Boulevard Permit Office: St. Lucie County
City, State, Zip: Fart Pierce , FL , 34951 Permit Number:
�
Owner: Adams Homes - 2320 Model Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
x
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ed ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the lop plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be Installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts In narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by Insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind n ping an wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that Is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire j2ci[lkj?[ gover plates and walls or ceilings,
uamoiy inspection of log walls snail be in accomance with one provisions or IGG-400.
12/18/2019 2:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1