Loading...
HomeMy WebLinkAboutEnergy Code7 !' FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential PYFfo"gtMVPood-- Project Name: Adams Homes - 2320 Model - 8505 Waterstone Builder Name: Adams Homes FEB 19 2020 Street: 8505 Waterstone Boulevard Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34951 Permit Number: ST. Lucie County, Permitting Owner: Adams Homes - 2320 Model Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1900.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1700.20 ft2 b. Frame - Wood, Adjacent R=11.0 200.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2332.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2332.00 ft2 6. Conditioned floor area above grade (ft2) 2332 b. N/A R= ft2 Conditioned floor area below grade (ft� 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(238.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 6 105 a. U-Factor: Sgl, U=0.33 166.03 ft' SHGC: SHGC=0.23 b. U-Factor: Sgl, U=0.33 72.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 40.0 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 40.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.224 14. Hot water systems 8. Floor Types (2332.0 sqft.) Insulation Area a. Electric Cap: 50 gallonsEF: a. Slab -On -Grade Edge Insulation R=0.0 2332.00 ft2 b. Conservation features 0.950 b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF. Pstat Total Proposed Modified Loads: 71.91 Glass/Floor Area: 0.102 PASS Total Baseline Loads: 72.49 I hereby certify that the plans and specifications covered by Review of the plans and STgl� this calculation are in compliance with the Florida Energy specifications covered by this oF'fA$ y Code. calculation indicates compliance �O with the Florida Energy Code. nnr "," °� i ;;•`°, PREPARED BY: Before construction is completed ,` DATE: 12-18-19 this building will be inspected for'"a compliance with Section 553.908 a * , I hereby certify that this building, as designed, is in compliance Florida Statutes. �. with the Florida EnSay Code.C'Op yyfi'tt�vy OWNER/AGFNT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th EditionFR pro ey Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Adams Homes - 2320 Model - Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2332 Lot # Owner Name: Adams Homes - 2320 Model Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Adams Homes Rotate Angle: 0 Street: 8505 Waterstone Soule Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Inl Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2332 20612.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Bedroom 4 175 1400 No 1 1 1 Yes Yes Yes 2 Bath 60 480 No 0 1 Yes Yes Yes 3 Hall 118 944 No 0 1 Yes Yes Yes 4 Bedroom 3 151 1208 No 1 1 1 Yes Yes Yes 5 Bedroom 2 210 1680 No 1 1 1 Yes Yes Yes 6 Family Room 338 3447.6 No 2 1 Yes Yes Yes 7 Foyer 72 720 No 0 1 Yes Yes Yes 8 Dining Room 182 1820 No 2 1 Yes Yes Yes 9 Breakfast Nook 146 1357.8 No 2 1 Yes Yes Yes 10 Kitchen 224 2307.2 Yes 2 1 No Yes Yes 11 Laundry 96 768 No 0 1 No Yes Yes 12 AHU 18 144 No 0 1 No Yes Yes 13 WIC 63 504 No 0 1 Yes Yes Yes 14 Master Bath 108 864 No 0 1 Yes Yes Yes 15 Master Bedroom 255 2040 No 2 1 1 Yes Yes Yes 16 Toilet 24 192 No 0 1 Yes Yes Yes 17 Hall 92 736 No 0 1 No Yes Yes 12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 - FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio Bedroom 4 28 ft 175 ft2 1 0 0 2 Slab -On -Grade Edge Insulatio Bath 6 ft 60 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulatio Hall 2 1 ft 118 ft2 — 1 0 0 4 Slab -On -Grade Edge Insulatio Bedroom 3 16 ft 151 ft2 __ 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 2 44 ft 210 ft2 ___ 1 0 0 6 Slab -On -Grade Edge Insulatio Family Room 13 ft 338 ft2 _ 1 0 0 7 Slab -On -Grade Edge Insulatio Foyer 8 ft 72 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Dining Room 18 ft 182 ft2 ___ 1 0 0 9 Slab -On -Grade Edge Insulatio Breakfast Nook 20.9 It 146 ft2 — 1 0 0 10Slab-0n-Grade Edge Insulatio Kitchen 1 ft 224 ft2 _- 1 0 0 11SIab-On-Grade Edge Insulatio Laundry 1 ft 96 ft2 ___ 1 0 0 12SIab-On-Grade Edge Insulatio AHU 1 ft 18 ft2 _ 1 0 0 13SIab-On-Grade Edge Insulatio WIC 7 ft 63 ft2 _ 1 0 0 14SIab-On-Grade Edge Insulatio Master Bath 6 ft 108 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulatio Master Bedroom 32 ft 255 ft2 _ 1 0 0 16SIab-On-Grade Edge Insulatio Toilet 6 ft 24 ft2 _ 1 0 0 178Iab-On-Grade Edge Insulatio Hall 1 1 ft 92 ft2 ___ 1 0 0 ROOF _ / Roof Gable Roof Red Solar SA Emift Emift Deck Pilch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2608 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2332 ft2 N N 12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Bedroom 4 30 Batt 175 ft' 0.1 Wood 2 Under Attic (Vented) Bath 30 Batt 60 ft' 0.1 Wood 3 Under Attic (Vented) Hall 30 Ball 118 ft2 0.1 Wood 4 Under Attic (Vented) Bedroom 3 30 Batt 151 ft' 0.1 Wood 5 Under Attic (Vented) Bedroom 2 30 Batt 210 ft' 0.1 Wood 6 Under Attic (Vented) Family Room 30 Batt 338 ft' 0 Wood 7 Under Attic (Vented) Foyer 30 Batt 72 ft' 0.1 Wood 8 Under Attic (Vented) Dining Room 30 Batt 182 ft' 0.1 Wood 9 Under Attic (Vented) Breakfast Nook 30 Batt 62 ft' 0.1 Wood 10 Under Attic (Vented) Breakfast Nook 30 Batt 84 ft2 0 Wood 11 Under Attic (Vented) Kitchen 30 Batt 224 ft' 0 Wood 12 Under Attic (Vented) Laundry 30 Batt 96 ft' 0.1 Wood 13 Under Attic (Vented) AHU 30 Batt 18 ft' 0.1 Wood 14 Under Attic (Vented) WIC 30 Batt 63 ft' 0.1 Wood 15 Under Attic (Vented) Master Bath 30 Batt 108 ft' 0.1 Wood 16 Under Attic (Vented) Master Bedroom 30 Batt 255 ft' 0.1 Wood 17 Under Attic (Vented) Toilet 30 Batt 24 ft' 0.1 Wood 18 Under Attic (Vented) Hall 1 30 Batt 92 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Ext InstBedroom 4 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 _ 2 W Exterior Concrete Block - Ext InstBedroom 4 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 _ 3 W Exterior Concrete Block - Ext Insul Bath 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 _ 4 E Exterior Concrete Block - Ed Insul Hall 2 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 _ 5 W Exterior Concrete Block- Ext InstBedroom 3 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 _ 6 E Exterior Concrete Block - Ext Inst8edroom 2 4.1 15 0 8 0 120.0 ft' 0 0 0.6 0 _ 7 S Exterior Concrete Block - Ext InstBedroom 2 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext InsdIedroom 2 4.1 15 0 8 0 120.0 ft' 0 0 0.6 0 _ 9 N Exterior Concrete Block - Ext ImItAmily Room 4.1 10 2 10 3 104.2 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ed Insul Foyer 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 _ 11 S Exterior Concrete Block - Ext In501ning Room 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ed InsiDining Room 4.1 5 0 10 0 50.0 ft' 0 0 0.6 0 _ 13 N Exterior Concrete Block - Ext InsWeakfast No 4.1 5 2 9 4 48.2 ft2 0 0 0.6 0 _ 14 NE Exterior Concrete Block - Ext Indideakfast No 4.1 3 10 9 4 35.8 ft2 0 0 0.6 0 _ 15 E Exterior Concrete Block - Ext Ins&eakfast No 4.1 2 7 9 4 24.1 ft' 0 0 0.6 0 _ 16 W Exterior Concrete Block - Ed InsWeakfast No 4.1 2 7 9 4 24.1 ft' 0 0 0.6 0 17 NW Exterior Concrete Block - Ext InsWeakfast No 4.1 3 10 9 4 35.8 ft2 0 0 0.6 0 18 E Exterior Concrete Block- ExtInsul WIC 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 _ 19 E Exterior Concrete Block - Ed InsMaster Bath 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 20 N Exterior Concrete Block - Ext Indd9ster Bedro 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 _21 E Exterior Concrete Block - Ext Inddkster Bedro 4.1 17 0 8 0 136.0 ft' 0 0 0.6 0 22 E Exterior Concrete Block - Ext Insul Toilet 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 23 E Garage Frame - Wood WIC 11 9 8 72.0 ft2 0.23 0.6 0 _ 24 E Garage Frame - Wood Laundry 11 12 8 96.0 ft' 0.23 0.6 0 25 N Garage Frame - Wood Dining Room 11 4 8 32.0 ft' 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In _ 1 N Wood Family Room None .39 2 10 6 10 19.4 ft' 2 S Wood Foyer None .39 3 6 10 20.5 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None 2 W 5 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None 3 S 7 Vinyl Low-E Single Yes 0.33 0.21 N 30.0 ft' 2 ft 0 in 4 ft 5 in None None 4 N 9 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 112 2 ft 0 in 0 ft 7 in None None 5 S 10 Vinyl Low-E Single Yes 0.33 0.23 N 10.0 ft' 2 it 0 in 1 ft 4 in None None 6 S 10 Vinyl Low-E Single Yes 0.33 0.23 N 13.7 ft' 2 it 0 in 1 ft 4 in None None 7 S 11 Vinyl Low-E Single Yes 0.33 0.21 N 12.0 ft2 2 it 0 in 1 ft 0 in None None 8 S 11 Vinyl Low-E Single Yes 0.33 0.21 N 30.0 ft2 2 ft 0 in 1 ft 0 in None None 9 N 13 Vinyl Low-E Single Yes 0.33 0.23 N 20.0 ft2 2 ft 0 in 0 ft 7 in None None 10 NE 14 Vinyl Low-E Single Yes 0.33 0.23 N 8.7 ft2 2 ft 0 in 0 ft 7 in None None 11 NW 17 Vinyl Low-E Single Yes 0.33 0.23 N 8.7 ft2 2 ft 0 in 0 ft 7 in None None _ 12 N 21 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft2 2 ft 0 in 0 It 7 in None None 13 E 22 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft2 2 it 0 in 0 ft 7In None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 462 ft2 462 ft2 25 ft 8 it 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000393 2404.8 132.02 248.28 .1418 7 12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 5 of 7 - FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 40 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit' Split SEER: 14.5 40 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SelPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ff' DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heal Cool 1 Attic 6 105 ft' Attic 25 ft' Default Leakage AHU (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: (rX fr rr Nov rr Venting Jan Feb MaDec r f Apr May Jun ri Jul Aug 4 Sep �X� Oct Nov lXl [ lnl X� [ [ [x� [x� [Xi [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 fib 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 Bedroom 4 Default(8 lbs/sq.ft. ft' ft 0.3 Bath Default(8 lbs/sq.ft. ft' ft 0.3 Hall Default(8 Ibs/sq.ft. ft' ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft' ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft' ft 0.3 Family Room Default(8 lbs/sq.ft. ft' ft 0.3 Foyer Default(8 Ibs/sq.ft. ft' ft 0.3 Dining Room Default(8 Ibs/sq.ft. ft' ft 0.3 Breakfast Nook Default(8 lbs/sq.ft. ft' ft 0.3 Kitchen Default(8 lbs/sq.ft. ft' ft 0.3 Laundry Default(8 lbs/sq.ft., ft' ft 0.3 AHU Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 Master Bath Default(8 lbs/sq.ft. ft' ft 0.3 Master Bedroom Default(8 lbs/sq.ft. ft' ft 0.3 Toilet Default 8 Ibs/s .ft. ft' ft 0.3 Hall 1 12/18/2019 2:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts,.. location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 40.0 a) Split system SEER 14.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2332 d) Room'uniVPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.224 14. Heating system: Capacity 40.0 c) Area 7c. 238.0 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. i Builder Signature Date: Address of New Home: 8505 Waterstone Boulevard City/FL Zip: Fort Pierce, FL 34951 12/18/2019 2:12:22 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Adams Homes - 2320 Model - 8505 Waterston Builder Name: Adams Homes Street: 8505 Waterstone Boulevard Permit Office: St. Lucie County City, State, Zip: Fart Pierce , FL , 34951 Permit Number: � Owner: Adams Homes - 2320 Model Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce x v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the lop plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be Installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by Insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind n ping an wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that Is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire j2ci[lkj?[ gover plates and walls or ceilings, uamoiy inspection of log walls snail be in accomance with one provisions or IGG-400. 12/18/2019 2:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1