HomeMy WebLinkAboutTile NOAMIAMI-DADE COUNTY
MIAMI- Q14DE PRODUCT CONTROL SECTION
•ing 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in
Miami -Dade County) and/or- the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Estate "S" Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 18-0829.03 and consists of pages I through 7.
The submitted documentation was reviewed by Freddy Semino
NOA No. 19-1021.03
Expiration Date: 08/23/21
Approval Date: 11/21/19
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Boral Estate `IS" Concrete Roof Tile, as manufactured by Boral Roofing, LLC in
Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building
Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by
applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127
using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Dimensions
Test
Product
Applicant
Specifications
Description
Boral Estate `S' Roof Tile
Length = 16-1/2"
TAS 112
Low profile, interlocking, extruded
Width = 13"
Type 1b
concrete roof tile equipped with two nail
Class III
hole and double roll ribs. For direct deck
or battened nail -on, mortar or adhesive
set applications.
Trim Pieces
1= varies
TAS 112
Accessory trim, concrete roof pieces for
w = varies
use at hips, rakes, ridges and valley
varying thickness
terminations. Manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 PRODUCTS MANUFACTURED BY OTHERS
Product Name
ICP Adhesives Polysee AH -160
TILE BOND' Roof Tile Adhesive
DAP Foam Touch N Seal
StormBond(-k) 2 Roof Tile Adhesive
Product Description
Two component polyurethane
foam adhesive.
Single component polyurethane
foam roof tile adhesive.
Two component polyurethane
foam adhesive.
Manufacturer
(With Current NOA)
ICP Adhesives and Sealants, Inc.
The Dow Chemical Company
Dap Foam, Inc.
NOA No. 19-1021.03
Expiration Date: 08/23/21
Approval .Date: 11/21/19
Page 2 of 7
2.3 EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Redland Technologies
7161-03
PA 102
Dec. 1991
7161-03
PA 102(A)
Dec. 1991
7161-03
PA 108
Dec. 1991
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
P0631-01
PA 108
July 1994
Letter Dated Aug. 1,
PA 108
Aug. 1994
1994
Professional Service Industries, Inc.
224-47099
PA 112
Sept. 1994
The Center for Applied
94-060B
PA 101
March, 1994
Engineering, Inc.
94-084
PA 101
May 1994
25-7094-1
PA 102
Oct. 1994
25-7094-7
PA 102
Oct. 1994
25-7094-4
PA 102
Oct. 1994
Project No. 307025
PA 100
Oct. 1994
Test #MDC -76
25-7183-1
PA 102
Feb. 1995
25-7183-2
PA 102
Feb. 1995
25-7214-2
PA 102
March, 1995
25-7214-6
PA 102
March, 1995
Celotex Corporation Testing Services
528454-2-1
PA 101
Sep. 1998
520109-2
Dec. 1998
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
IBA Consultants, Inc. 2381-264 TAS 112 01/08/08
American Test Lab of South Florida RT1210.03-15 TAS 112 12/17/15
PRI Construction Material DAPF-004-02-05 TAS 101 07/26/18
Technologies DAPF-004-02-07 Static Uplift Resistance 07/26/18
(Adhesive Set)
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with. TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 Minimum slope 4/12 for mechanically attached tile.
3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
NOA No. 19-1021.03
MIAMI -DAD' COUNTY Expiration Date: 08/23/21
A
� Fg
Approval Date: 11/21/19
Page 3 of 7
3.7 All products listed herein shall have a duality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Boral Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile Weight -W (Ibf) Length -I (ft.) Width -w (ft.)
3oral Estate 'S' Roof Tile 10.0 1.375 1.08
Table 2: Aerodynamic Multipliers - X (ft3)
Tile ). (ft3) ). (ft3)
Profile Batten Application Direct Deck Application
Boral Estate 'S' Roof Tile 0.267 0.289
2-10d Ring Shank Nails' 43.0 67.5 1 50.9
NOA No. 19-1UM-W
MIAMIDARE- Expiration Date: 08/23/21
I Approval Date: 11/21/19
Page 4 of 7
Table 3: Restoring
Moments
due to Gravity - Mg
(ft.-lbf)
Tile
3••:12"
4":12"
5":12"
6":12"
Greater than
7":12"
Profile
=Tile
Direct
Deck
6.74
Battens Direct
Deck
5.82 6.64
Battens Direct
Deck
5.70 6.50
Battens Direct
Deck
5.56 6.33
Battens Direct
Deck
5.40 6.14
Boral Estate
`S' Roof Tile
2-10d Ring Shank Nails
1-10d Smooth or Screw
Shank Nai12
2-10d Smooth or Screw
2-10d Ring Shank Nails' 43.0 67.5 1 50.9
NOA No. 19-1UM-W
MIAMIDARE- Expiration Date: 08/23/21
I Approval Date: 11/21/19
Page 4 of 7
Table 4: Attachment Resistance
Expressed as a Moment - Mf (ft-lbf)
for Nail -On Systems
Direct Deck
(min 15132" plywood)
Direct Deck
(min. 19/32" plywood)
Battens
Tile
Profile
Fastener Type
27.8
8.8
37.4
11.8
28.8
4.1
Boral Estate
`S' Roof Tile
2-10d Ring Shank Nails
1-10d Smooth or Screw
Shank Nai12
2-10d Smooth or Screw
16.4
21.9
7.1
Shank Nails
1 #8 Screw2
2 #8 Screw
1-10d Smooth or Screw
25.8
47.1
24.3
25.8
47.1
24.3
22 9
49.1
24.2
Shank Nail (Field Clip)2
1-10d Smooth or Screw
19.0
19.0
22 1
Shank Nail Eave Clip)2
2 -10d Smooth or Screw
35.5
35.5
34.8
Shank Nails (Field Clip)
2-10d Smooth or Screw
31.9
31.9
32 2
Shank Nails (Eave Clip)
2-10d Ring Shank Nails' 43.0 67.5 1 50.9
NOA No. 19-1UM-W
MIAMIDARE- Expiration Date: 08/23/21
I Approval Date: 11/21/19
Page 4 of 7
I Installation with a 4" the headlap and fasteners are located a min. of 2'/2" from head of tile.
2 When using only one fastener use the hole that is approximately 4-3/4" away from interlocking edge.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Boral Estate 'S' Roof Tile
Adhesive
3 See manufactures component approval for installation requirements.
4 The Dow Chemical Co. TILE BONDTm Roof Tile Adhesive weight per patty 11.4 grams. 26.1
5 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset@ AH -160 Two -Component weight per patty 8 grams 26.1
6 DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 8 grams. 35.0
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Boral Estate `S' Roof
Tile
Adhesive?
7 See manufactures component approval for installation requirements -
8 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH -160 Two -Component weight per patty 54 grams. 86.61
9 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH -160 Two -Component weight per patty 24 grams 45.5
10 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 60 grams. 60.0
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf)
for Mortar or Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Boral Estate 'S' Roof
Mortar Set
20.60
Tile
NOA No. 19-1021.03
MIAMI-DADE cau� Expiration Date: 08/23/21
Approval Date: 11/21/19
Page 5 of 7
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
n
OR
7��7 C IN T IE IU IR [A 7��7
BORAL ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No. 19-1021.03
Expiration Date: 08/23/21
Approval Date: 11/21/19
Page 6 of 7
Nail Holes
M-
PROFILE DRAWING
BoRAL ESTATE "S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No. 19-1021.03
Expiration Date: 08/23/21
Approval Date: 11/21/19
Page 7 of 7