Loading...
HomeMy WebLinkAboutTile NOAMIAMI-DADE COUNTY MIAMI- Q14DE PRODUCT CONTROL SECTION •ing 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or- the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Estate "S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 18-0829.03 and consists of pages I through 7. The submitted documentation was reviewed by Freddy Semino NOA No. 19-1021.03 Expiration Date: 08/23/21 Approval Date: 11/21/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Estate `IS" Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Boral Estate `S' Roof Tile Length = 16-1/2" TAS 112 Low profile, interlocking, extruded Width = 13" Type 1b concrete roof tile equipped with two nail Class III hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for w = varies use at hips, rakes, ridges and valley varying thickness terminations. Manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polysee AH -160 TILE BOND' Roof Tile Adhesive DAP Foam Touch N Seal StormBond(-k) 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam, Inc. NOA No. 19-1021.03 Expiration Date: 08/23/21 Approval .Date: 11/21/19 Page 2 of 7 2.3 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 PA 102 Dec. 1991 7161-03 PA 102(A) Dec. 1991 7161-03 PA 108 Dec. 1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, PA 108 Aug. 1994 1994 Professional Service Industries, Inc. 224-47099 PA 112 Sept. 1994 The Center for Applied 94-060B PA 101 March, 1994 Engineering, Inc. 94-084 PA 101 May 1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 PA 102 Oct. 1994 25-7094-4 PA 102 Oct. 1994 Project No. 307025 PA 100 Oct. 1994 Test #MDC -76 25-7183-1 PA 102 Feb. 1995 25-7183-2 PA 102 Feb. 1995 25-7214-2 PA 102 March, 1995 25-7214-6 PA 102 March, 1995 Celotex Corporation Testing Services 528454-2-1 PA 101 Sep. 1998 520109-2 Dec. 1998 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 IBA Consultants, Inc. 2381-264 TAS 112 01/08/08 American Test Lab of South Florida RT1210.03-15 TAS 112 12/17/15 PRI Construction Material DAPF-004-02-05 TAS 101 07/26/18 Technologies DAPF-004-02-07 Static Uplift Resistance 07/26/18 (Adhesive Set) 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with. TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Minimum slope 4/12 for mechanically attached tile. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No. 19-1021.03 MIAMI -DAD' COUNTY Expiration Date: 08/23/21 A � Fg Approval Date: 11/21/19 Page 3 of 7 3.7 All products listed herein shall have a duality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Boral Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight -W (Ibf) Length -I (ft.) Width -w (ft.) 3oral Estate 'S' Roof Tile 10.0 1.375 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile ). (ft3) ). (ft3) Profile Batten Application Direct Deck Application Boral Estate 'S' Roof Tile 0.267 0.289 2-10d Ring Shank Nails' 43.0 67.5 1 50.9 NOA No. 19-1UM-W MIAMIDARE- Expiration Date: 08/23/21 I Approval Date: 11/21/19 Page 4 of 7 Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf) Tile 3••:12" 4":12" 5":12" 6":12" Greater than 7":12" Profile =Tile Direct Deck 6.74 Battens Direct Deck 5.82 6.64 Battens Direct Deck 5.70 6.50 Battens Direct Deck 5.56 6.33 Battens Direct Deck 5.40 6.14 Boral Estate `S' Roof Tile 2-10d Ring Shank Nails 1-10d Smooth or Screw Shank Nai12 2-10d Smooth or Screw 2-10d Ring Shank Nails' 43.0 67.5 1 50.9 NOA No. 19-1UM-W MIAMIDARE- Expiration Date: 08/23/21 I Approval Date: 11/21/19 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Direct Deck (min 15132" plywood) Direct Deck (min. 19/32" plywood) Battens Tile Profile Fastener Type 27.8 8.8 37.4 11.8 28.8 4.1 Boral Estate `S' Roof Tile 2-10d Ring Shank Nails 1-10d Smooth or Screw Shank Nai12 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw2 2 #8 Screw 1-10d Smooth or Screw 25.8 47.1 24.3 25.8 47.1 24.3 22 9 49.1 24.2 Shank Nail (Field Clip)2 1-10d Smooth or Screw 19.0 19.0 22 1 Shank Nail Eave Clip)2 2 -10d Smooth or Screw 35.5 35.5 34.8 Shank Nails (Field Clip) 2-10d Smooth or Screw 31.9 31.9 32 2 Shank Nails (Eave Clip) 2-10d Ring Shank Nails' 43.0 67.5 1 50.9 NOA No. 19-1UM-W MIAMIDARE- Expiration Date: 08/23/21 I Approval Date: 11/21/19 Page 4 of 7 I Installation with a 4" the headlap and fasteners are located a min. of 2'/2" from head of tile. 2 When using only one fastener use the hole that is approximately 4-3/4" away from interlocking edge. Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Boral Estate 'S' Roof Tile Adhesive 3 See manufactures component approval for installation requirements. 4 The Dow Chemical Co. TILE BONDTm Roof Tile Adhesive weight per patty 11.4 grams. 26.1 5 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset@ AH -160 Two -Component weight per patty 8 grams 26.1 6 DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 8 grams. 35.0 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Boral Estate `S' Roof Tile Adhesive? 7 See manufactures component approval for installation requirements - 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH -160 Two -Component weight per patty 54 grams. 86.61 9 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH -160 Two -Component weight per patty 24 grams 45.5 10 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 60 grams. 60.0 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Mortar or Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Boral Estate 'S' Roof Mortar Set 20.60 Tile NOA No. 19-1021.03 MIAMI-DADE cau� Expiration Date: 08/23/21 Approval Date: 11/21/19 Page 5 of 7 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". n OR 7��7 C IN T IE IU IR [A 7��7 BORAL ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No. 19-1021.03 Expiration Date: 08/23/21 Approval Date: 11/21/19 Page 6 of 7 Nail Holes M- PROFILE DRAWING BoRAL ESTATE "S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No. 19-1021.03 Expiration Date: 08/23/21 Approval Date: 11/21/19 Page 7 of 7