DESIGN CRITERIA:
The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design,
Chapter 20 Aluminum, and Chapter 23 Wood.
AA ASM 35 and AA ADMl Specifications for Aluminum Structures, Part 1-A of the
Aluminum Design Manual prepared by The Aluminum Association and the AAF Guide to
Aluminum construction in High Wind Areas.
ASCE 7-10.
105.1
2. Dead Load:2 PSF
3. Wind Load:
3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Categor , 1.
3.2. Ultimate Design Wind Speed: VULT =150 MPH Nominal Design Wind Speed: VASD
=116 MPH
3.3. Exposure Category, Section 1609.4.3: Exposure C
3.4. Screen Enclosure Secfion2002.4
4. Building Category for Aluminum Structures, Section 2002.6: Cateeory Tvce 1 - Screen
Room /Alum Shed: Non -Habitable, Unconditioned
WIND SPEED AND EXPOSURE HAVE
BEEN DETERMINED USING THE ADVANCED
TECHNOLOGY COUNCIL'S WEBSTTE
AND GOOGLE EARTH.
Roof Tvce
1. Roof Type: MONOSLOPE
2. Roof Material: 3" x 48" x 0.024" composite panel Elite 2000, 1.0# density foam. Florida :F
Product Approval Number FL 7561-R4.
f-t-
The following specifications are applicable to this project:
1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any
other applicable local codes and regulations.
2. Aluminum extrusions shall be 6005 T5 Alloy. Due in quality control issues, no manufacturer
substitution is acceptable without the specific written, signed and sealed authoriration of
Florida Aluminum Engineering, Inc.
3. Screen material shall be 18114 screen unless approved by Florida Aluminum Engineering, Inc.
4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to
ASTM B633, or coated stainless steel series "300", or uncoated stairdess steel series "400".
5. Approved concrete screw anchors to be Simpson Titen-ED or equivalent.
6. All Self Mating Beam Sections are m be stitched with either #14 screws 6" from ends and 24"
center to center or #12 screws 6" from ends and 12" center to center.
7. Door location shall be determined by contractor in the field.
S. Where concrete specifications are required, whether in the screen enclosure scope or not, by
one or more regulatory agency, the following specifications are applicable:
a. Concrete shall conform to ASTM C94 for the following components:
i. Portland Cement Type 1,- ASTMC 150
ii. Aggregates - Large Aggregate 314" max - ASTM C 33
iii. Air entraining +/-1%-ASTMC 260
iv. Water reducing agent - ASTM C 494
v. Clean Potable water
vi. Other admixtures not permitted
b. Metal accessories shag conform to:
I. Reinforcing Bank - ASTMA615, grade 60
ii. Welded who fabric - ASTM Al85
C. Concrete slump at discharge chute not less than 3" or more than 5". Water added after
bitching is not permitted
d. Prepare and place concrete per American Concrete Institute Manual of Standard
Practice, Parts 1, 2, and 3 including hot weather mcommendations.
e. Moist cure or polyethylene curing permitted.
f. Prior to placing concrete, treat the entire subsurface area for termites in compliance
with the FBC.
g. Concrete shall be placed ever a polyethylene vapor barrier.
h. AR aluminum components embedded within concrete shall be coated with a
bituminous paint or epoxy.
9. AR lumber and plywood shall have grade marks and treatment identification and Shall
conform to the following:
a Framing lumber shall be minimum no. 2 southenfyellow pine and have a maximum
moisture content of 15%.
b. Pressure treatments shall be osmosalts, carouse k-33, womansalts or celcure, as
recommended for the we condition. Pressure treated lumber shall be impregnated with
a cca salt treatment in accordance with fs. tt-w-571 and bear the American Wood
Preservatives Institute quality mark Ip-2.
c. Wall Sheathing: APA rated Sheathing, thickness as indicated, Exposure 1.
d. Aluminum members that are uncoated shall be separated from PT lumber by 30# felt
paper, 10 mil polyethylene sheet or equivalent material.
10. Contractor shall provide Florida Product Approval information as to the exact window
being utilized for this project, including manufacturers specifications, and installation methods
for anchoring the submitted windows to alum members and specific aim as indicated on A-1.
11. Contractor shall provide any additional backing (aluminum, wood etc..) and anchors as
required by the window manufacturers recommended procedures.
12. AB glass panels within 24" of a door opening shall be of tempered glass per FBGR308.4
13. All flashing and weatherproofing shall be provided by the contractor.
14. Use of these plans acknowledges and accepts a limit of liability not to exceed design and
engineering fee.
- 9'-5^
3X3X0.093
POST 1
V(TYP2TX�2I
GRT
) 20
1X2
V-11"
71
A-3
A-3
8 -0" 8 -0"
8 -0"
-
- - -
2X5-
4THSWALL_
S-4 3X2X0.050
EDGE BEAM
A-3 END BEAM
3X2XO.050
0
END BEAM 3"X48"XO.024"
I
1.0$ DENSITY
FOAM
COMPOSITE
PANEL
io
1
3X2XO.O5O
2x3PBO
AA-3EDGE BEAM
A-3 16" O.C.
A-4
A-4
16'-0"
` 1'-0.
3"X48"XO.024"
1.0# DENSITY FOAM
COMPOSITE PANEL
M
ME
` •(y.:•y
0
I
J
3" REC CHANNEL
TOP PLATE
�1/2" PLYWOOD
HOUSE WRAP
VINYL SIDING
F--- W I W-13:
•e
M
colet0
r
n v
"t
LU
S.
d
rrn Qv
"•,
9,-5"
3X3XO.093
COPY
COMPONENTS & CLADDING - Vwm
DESIGN PRESSURES FOR WINDOWS / DOORS:
+24.3 PSF / -32.0 PSF
ADJUSTED CO-EFFICIANT FOR EXP C - 1.21
+29.4 PSF / -38.70 PSF
EVI M FOR
CODE COMPLIANCE
LLACIE C/OU %V
K ]l.l
W
w p
Z m
z tFW to
to
W Z z
z aZ
O a W
H CQC V
LL G
O O
z H
a
2 c-
ZZS
5 zrwm�
LU nag
Q W i>mm
o z
� C9
Ow$
U-
W
rr% Z
LU
Q J
Lu
U ul U
-1 W_
�LUoam
O�N��
a �0
TP
04/01 /20
A-1
InUblq�ej
„,,p�1111
wo-
LL b 2y's
REVIEWED FOR
Q z o
O o• =_
CODE COMPLIANCE
3a :w 10
w a: ¢c
#14 x 4"SMS W/
10�
d) '
a o z
1 1 /2” DIA. NEOPRENE
FACED WASHER ®6"D.C•
�1'�`
®. Ll7CI^■^E/^�C/\OIIN''X
a
••
�V :
\
C7
i Z
Ia-k'v.Y\�..r wn v S,,r!+,1L��°ii Iviyia
`y+s*lr`1ilL y.�l w'✓
FLASHING
BV OTHERS
�I 'J°
i�IF"A
... Q•04 \\\
3„x 3"x0.093"
N:r.,.
x�R 1yf9.vn'lits
POST
��:,rn33��`•'y }^"�
`,1,,:.:$•..
isw%�����
(�3/6"DIA CONCRETE
. .. r
3" COMPOSITE
SCREWANCHORS
ROOF PANEL
(3" CONIC. EMBED)
3" COMPOSITE
C ni
ROOF PANEL
h ?
T h. 5
W
W a
E-GUTTER VJ/#12 1T'O.C.
^�if rJM1 I
r n� 'N''j,'JJy{. •�+il
Z m
1"x T OB W/ NCRETE
WTE TERNAL
TOP & EDT. 3 PER PANEL 1"x i"x 1/8" ALUM
( )
u"•
f,.1, mot•., ,,^: h' - �•
Lu
SCREW ANCHOR B"
EWAN
"x 118"
3"%3"%1/8"EXTRUDED
ANGLE W/(3)#12Z
w
FROM UPRIGHT & ®
24"
POST BASE W/ (2) 3/6'
x 3/4" SMS EACH SIDE
#14 4° SMS W/ I
W z O
�L
O.C. (MIN. 3" EMBED.)
DIA. THRU BOLTS
(2)1/4"D10. 3"x2'x0.050'
THRU BOLTS
x
11/T DIA NEOPRENE EXISTING�I
J =
Q < O
z
FACED WASHER ® 4" O.C. BUILDING
z
— — — — —
UPRIGHT OR POST
SEE BHT FOR AOD'L
3 318" DIA
Q C W
•p
MEMEBQ21NF0.
THRU BOLTS
Ln W
LU
y
'
2"z5'SMB
LL
0 O
• xd'.!
Wx3"x0.093"
-�
_
POST
^
J
B'I
\COMPOSITE ROO
LROOFLO POST CONNECTION
3" x 3" POST TO CONCRETE CONNECTION
DETAIL
SCENTS
A_3
S-I COMPOSITE ROOF TO POST 04TH WALL DETAIL
Z Z
e o
(,7h§R- -
SCALE: MS
A-3
z t a
m��
A-3 SCALE: NTS
s
a Lu m
z 1;5 a
oz$
W
3" COMP ROOF PANEL SELF -MATING BEAM
u_
#14x4"SMSW/
11/2"CIA
r..r.�xr.. ,+, ,r.. r�•p-G,Y.'•:u•ni. ..
yn�T-'7."1 ;T
.NEOPRENE
FACED WASHER @ W O.C.
3"COMPOSITE
ROOF PANEL�4,•5r-J_:.4ytrt:},/s;W:ilLwvsin..:�e.
#14 SMS x 1" MIN. LONGER
fST�'j,�,y�y-S,r'Ti{.:V'i`!C�~`'_-,'i `�'rh.+µ•:7Ya4o •^'°='S+
'vey,.,+y r",t•'S5e•yt�,r1;t!'�+�.':: ��rnl'¢•`;,j.;�`;:'J�>}„
FLASHING
THAN PANEL W/ 1 1/2"DIA
�:: S.y ,�,
i • in;fy 1.•.>;SK r,„?.: n,1,Po-kTr{„�. .t•',v?±`,r,-,�H,. .S;a-S; >1>�a.
074 SINS z T' MIN. LONGER
By OTHERS
#14 x 4" SMS W/
t 1 NEOPRENE FACED WASHER
DIA NEOPRENE
— — — — — — — — -'
THAN PANEL W/ 7 72"DIA
FACED WASHER S' O.C. OF1A O.C. BO�NGMS LENGTH
W
NEOPRENE FACED WASHER 3" COMPOSITE
Q 17' O.C. ALONG LENGTH ROOF PANEL
7
w
OF ALL END BEAMS
. +.•,4
"'+r.
. •
•C/'i' Y5 k•+T\•iiUl: i
....+y •fib . �l"L.,.+YYy4N d�"'.�v:
ti';,s.�tn•tiy,;. +µ, 'a4: " + °.
I _ — _ _ _
z
N W
w, { ,4w�lYN�,•,,W..i.:in
V�
d '�i,)v
I
>>'VS;'N=� :+''s'+i f �: �i
Y.N 4�l i ri4 5 )(L(fiJ •vAi f+"?i1,,.%J,y'�4(i. r4fl t
a^4 AIL �i •\S,L� �6� PM1 �.�J*Y'i.- 4yk W(N .lis!'%•.5V
_ _ _
• 0 O
ULI
P1>,�
t1�J �{V�i'�� Y-41
\1�T, fl1'1'T
'
� Q
=Yh
•
\\
I
3END ZBEAM
M•
\
LLI
3"x 2'x0.050" •
i/��/ /
EXIS-ING�I
\ \
\
of LU
Q W 0
END BEAM •
BUILDING
�° — -- —' "_ -""' - -
'—
\
J
- '— _ — — _ ._
E-GUTTER W/ 012 @17' O.C. • -
\ 1 '
\
w_
0_
TOP & GOT. (3 PER PANEL)
2" x 3" x 0.05G' \ \
W m
11/8" x 212'x 111S` x 0.125"
I
71/2"x2118" x 11Y1'x 0.087'x 3"LONG
KNEE BRACE \ \ UPRIGHT
Q J M LL, M
ALUM RECEIVING CHANNEL
W/ (O x 3/4" SMS EACH
I
ALUM RECEIVING CHANNEL W/ (3)
3"x2"x 0.050" #14x 3/4"SMS EACH SDEOF
\ e
w _ ^ 0 J
d � N LL LL
SIDE OF BEAM 8 (2) 3/8" DIA
B
EDGE BEAM BEAM 8 (2) 3/8" DIA. THRU BOLTS
•
DRAWN BY
THRU BOLTS INTO THE POST
UPRIGHT OR POST INTO POST
71/2"x21/8"x 11/Y'x
LT
3/6" DIA THRU BOLT
I
SEE SHT FOR ADD'L
0.062" % 3" LONG ALUM
TP
(3 TOTAL)
I
MEMEBER INFO. i"xi"x1/8"ALUM
ANGLE W/ (3) #12
REOEVING CHANNEL W/ (3)
#12 x 3/4" SMS EA. FACE &
DATE DRAWN
2" x 5" S
z 3/4" SMS EACH SIDE
(3) 012 x 3/4" INTO POST
04/0 1 /20
3"x 3'•x 0.083" --
J
REVISION
POST
S-Z ROOF TO CORNER POST Cil 4TH
WALL DETAIL
S-3 COMPOSITE ROOF TO POST (0, CORNER CONNECTION
S-4 KNEE BRACE CONNECTION DETAIL
A 3 SCALE NTS
_COMP.
A-3 SCALENTS
A-3 SCALE: NTS
SHEET NO:
A-3
i\
�� .•�
LL
�'-
=ei
°
Ca
O Q=
W W
p_cp
fi
Z [l
FrW
z
W Z
J
a Z
Z
O d LU
z
-c
w
s
O O J
REVIEWED FOR
a '-
CODE COIMPLIAN
F
r
ST. LUCIE COUNT
z $
! oor,
Z
_
3" COMPOSITE #14 x 4"SMS W
ROOF PANEL 112" CIA NEOPRENE
FACED WASHER C 6' O.C.
cmlil
"
p....:
GRADE
GRADE
4„ "•
`r:'F"��tilti��rGa
'� • °' a
VINYL SIDING
•
°PER
INSTALL ERS
MANUFACTURER'S
112"x 3"x 112"x 0.052'
��' 4 '
^
'4
SPECIFICATIONS
CHANNEL W/ 012 x SM"
�)
B" ♦
° •
-
SMS EACH SIDE
•- •' (2) #5 CONT 31"OVERLAP;
�'
INFILTRATION BARRIER
#5 CONT 31" OVERLAP
. . AT JOINTS ON Y CHAIRS
OVER 1/2" PLYWOOD FASTEN
AT JOINTS ON 3" CHAIRS
I
@ PANEL EDGES W/ 910
x1"@EV'O.C.&Q 12" O.C. Q�j
2" x 3" x 0.045"
HOLLOW®1S'O.C.
TYPE II
t---$.—i
INTERMEDIATE SUPPORTS
MODERATE SLOPE FTG
2:12- 3:12
TYPE II
MODERATE SLOPE FTG
2:12-312
NOTES FOR ALL FOUNDATION TYPES.
1.
THE FOUNDATIONS SHOWN ARE BASED ON AMIN SOIL BEARING PRESSURE
NOTES FOR ALL FOUNDATION TYPES
112"x 3"x 112"x 0.032'
OF1,500PSF.
1.
THE FOUNDATIONS SHOWN ARE BASED ON A MIN SOIL BEARING PRESSURE
HANNEL VW(2)#12 x314'
2.
THE SLAB/FOUNDATION SHALL BE CLEARED OF DEBRIS, ROOTS AND
OF 1,500 PSF.
SMS EACH SIDE
COMPACTED PRIOR TO PLACEMENT OF CONC.
2.
THE SLAB/FOUNDATION SHALL BE CLEARED OF DEBRIS, ROOTS AND
3.
CONCRETE SHALL BE PER SPECIFICATIONS ON SHEET Al.
COMPACTED PRIOR TO PLACEMENT OF CONC.
4.
FIBERMESH MAY BE USED IN LIEU FOR WELDED W RE MESH.
3.
CONCRETE SHALL BE PER SPECIFICATIONS ON SHEET Al.
5.
VAPOR BARRIER NEED NOT BE INSTALLED FOR EXTERIOR NON -HABITABLE
4.
FIBERMESH MAY BE USED IN LIEU FOR WELDED WRE MESH.
1/4" x 2 V4" CONC.
•
CONCRETE FLAT WORK
5.
VAPOR BARRIER NEED NOT BE INSTALLED FOR EXTERIOR NON -HABITABLE
SCREW ANCHOR
4 1
CONCRETE FLAT WORK
®1B"OC
i• a
A
TYPE II FOOTING
SCALE:
A-4
A -'I TYPE II FOOTING
SCA
S-5_ WALL
ASSEMBLY & CONSTRUCTION DETAIL
A-4
A-4
SCALE:NTS
wa
z
Z)
I a4
= a
J LLmm
Q W wamm
z
Q W z $d •'
(D
Oz�
a
st
LL lJJ
LL C
IE
W
CN LU
H
W Q
J
I< Ir W
(J J W
ULJ Lu
L
DRAWN BY
TP
DATE DRAWN
04/01 /20
REVISION
1 -
A
A-4
.F(LE COPY
a :•I t /•
^ — �b