HomeMy WebLinkAboutProduct Identificationy i
MATERIAL SAFETY DATA SHEET
THERMOPLASTICS (PVC RAILING, FENCING & SHEDS) FILE NO.: BOL-PL-001
MSDS DATE: 04/09/2010
SECTION 1: PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NAME THEMOPLASTICS (PVC RAILING, FENCING & SHEDS)
SYNONYMS: POLYVINYL CHLORIDE, VINYL, PVC
PRODUCTCODES:
MANUFACTURER: BARRETTE OUTDOOR LIVING, INC
DIVISION: PLASTICS
ADDRESS: 740 N MAIN STREET, BULLS GAP, TN 37711
EMERGENCY PHONE: 423-601-7300
CHEMTREC PHONE:
OTHER CALLS: 423-601-7300
FAX PHONE:
CHEMICAL NAME- WA
CHEMICAL FAMILY: WA
CHEMICAL FORMULA: WA
PRODUCT USE: FENCING, RAILING, STORAGE SHED
PREPARED BY: EHS DEPT
SECTION 2: HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW: This product Is considered non -hazardous when used as intended
ROUTES OF ENTRY- None expected
EFFECTS OF OVEREXPOSURE:
There are no significant health hazards from vinyl compound at ambient temperature. Inhalation of decomposition or combustion products,
especially hydrogen chloride, will cause irritation of the respiratory tract, eyes and skin. Depending on the severity of exposure, physiological
response will be coughing, pain and inflammation. Individuals with bronchial asthma and other types of chronic respiratory diseases may
develop bronchspasm If exposure Is prolonged.
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: WK
CARCINOGENICITY
OSHA: NO ACGIH: NO NTP: NO IARC: NO
SECTION 3: COMPOSITIONIINFORMATION ON INGREDIENTS
INGREDIENT., All ingredients are bound -up In the manufacturing process and are not expected to create any hazard In handling or use.
Finished goods are inert
Fence, Railing, Sheds, Lineal Fence Parts.
SECTION 4: FIRST AID MEASURES
If irritation persists from exposure to decomposition products, remove the affected individual from the area. Provide protection before reentry
SECTION 5: FIRE -FIGHTING MEASURES
Flashpoint: Not applicable to solid products.
Ignition Temperature: PVC> 7301F (>388°C)
Flammable Limits in AG (% by volume): Lower— WA; Upper— WA
Extinguishing Media: Water spray, ABC dry chemical, AFFF, protein type air foams. Carbon dioxide maybe Ineffective on larger fires due to a
lack of cooling capacity, which may result in mignition.
Firefighting Instructions: Wear positive pressure self-contalned breathing apparatus (SCBA). Personnel not having suitable respiratory
protection must leave the area to prevent significant exposure to toxic combustion gases from any source. In enclosed or poorly ventilated
areas, wear SCBA during clean-up Immediately after a fire as well as during the attack phase of firefighting operations.
Unusual Fire and Explosion Hazards: None known.
Hazardous Decomposition Products: CO, CO2 hydrogen chloride and small amounts of benzene and aromatic and aliphatic hydrocarbons.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Material is InerL Place into a container for reuse or disposal.
Water Disposal Method: Dispose of waste in accordance with federal, state and local regulations. For waste disposal purposes these
products are not defined or designated as hazardous by current provisions of the Federal Resources and Recovery Act (RCRA) 40CFR261.
SECTION 7: HANDLING AND STORAGE
PAGE 1 OF 2
-BB ---We-
re MATERIAL SAFETY DATA SHEET
THERMOPLASTICS (PVC RAILING, FENCING & SHEDS) FILE NO.: BOL-PL-001
INSDS DATE: 04/09/2010
As the user has the responsibility to provide a safe workplace, all aspects of an Individual operation should be examined to determine if, or
where, precautions, in addition to those described herein. Any health and safety information contained herein should be passed on to your
customers or employees, as the case may be.
SECTION 8: EXPOSURE CONTROLSIPERSONAL PROTECTION
Ventilation:
Provide efficient exhaust at all operations capable of creating fumes or vapors. Cutting or sawing, machining, heat welding,
thermofolding and other operations Involving heat sufficient to result In degradation should be examined to ensure adequate ventilation.
Respiratory Protection:
Not normally required. If overheating results in decomposition resulting in smoke or fumes a NIOSHIMSHA approved combination high
efficiency particulate filter with organic vapor cartridge can be used. Gross decomposition may require the use of a positive pressure self-
contained breathing apparatus.
Protective Equipment
Wear safety glasses.
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
Boiling Point WA
Melting Point NIA
Vapor Pressure: WA
Vapor Density: NIA
Solubility In Water. Insoluble
% Volatile by Weight: WA
Specific Gravity. (1-120=1)1.35-1.55
Appearance and Odor. No odor.
SECTION 10: STABILITY AND REACTIVITY
CHEMICAL STABILITY: Stable
HAZARDOUS POLYMERIZATION: Will not occur
SECTION 11: TOXICOLOGICAL INFORMATION
TOXICOLOGICAL INFORMATION: WA
SECTION 12: ECOLOGICAL INFORMATION
ECOLOGICAL INFORMATION: WA
SECTION 13: DISPOSAL CONSIDERATIONS
WASTE DISPOSAL METHOD: Dispose of in accordance to federal, state and local regulations. Product is not considered hazardous waste.
SECTION14: TRANSPORT INFORMATION
For domestic transportation purposes, these products are not defined or designated as a hazardous material by the
U.S. Department of transportation under Title 49 of the Code of Federal Regulations, 1983 Edition,
DOT Proper Shipping name: NIA
DOT Hazard Class: Not hazardous
DOT label: None required
UNINA Hazard No,: WA
SECTION 15: REGULATORY INFORMATION
U.S. FEDERAL REGULATIONS: NIA
STATE REGULATIONS: NIA
INTERNATIONAL REGULATIONS: WA
SECTION 16: OTHER INFORMATION '
The information contained herin is based on data available and is believed to be correct; however, Barrette Outdoor Living makes no
warranty, expressed or Implied, regarding the accuracy of this data. No liability is assumed for injury from the use of the product described
herein.
PAGE 2 OF 2