Loading...
HomeMy WebLinkAboutProduct approvals, Door Masonite 2/10/2020 Florida Building Code Online Business & /Y1 Il ttF Professional Regulation 'I BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search b' pr `�' Product Approval � USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF FL# FL22513-R2 SECRETARY Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800) 663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 04/16/2018 Date Validated 04/18/2018 Date Pending FBC Approval https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnH3%2f4ffe95AGs%2fx%2fSZXm2lgg%3d%3d 1/3 2/10/2020 Florida Building Code Online Date Approved 04/24/2018 Summary of Products FL# Model,Number or Name Description 22513.1 HPC Wood-edge Steel Side-Hinged 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.01-111.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0212.pdf Building Code,including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R2 AE 514008.pdf Door top rails stamped"HPC". See DWG-MA-FL0212 for details. Created by Independent Third Party: Yes 22513.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S or O/S Single Door Unit Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II F1_0215.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0"x 8'-0" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not FL22513 R2 AE 514009.pdf required. See DWG-MA-FL0215 for details. Created by Independent Third Party: Yes 22513.3 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +45/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code,including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R2 AE 514007.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0215 for details. 22513.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +50/-45 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R2 AE 514007.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0215 for details. 22513.5 Wood-edge Steel Side-Hinged Door 8'-0"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.06.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0217.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R2 AE 514007.pdf See DWG-MA-FL0217 for details. Created by Independent Third Party:Yes 22513.6 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single Door https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnH3%2f4ffe95AGs%2fx%2fSZXm2lgg%3d%3d 2/3 2/10/2020 Florida Building Code Online Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0211.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0"x 6'-8" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not FL22513 R2 AE 514010.pdf required. See DWG-MA-FL0211 for details. Created by Independent Third Party: Yes 22513.7 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +55/-55 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0211.pdf Building Code,including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R2 AE 514008.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party:Yes DWG-MA-FL0211 for details. 22513.8 Wood-edge Steel Side-Hinged Door 6'-8"3/4-Lite Glazed I/S or O/S Single or Double Door w/o Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.03-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II 1`1_0214.pdf Building Code,including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R2 AE 514008.pdf See DWG-MA-FL0214 for details. Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® 0J Credit Card Safe https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnH3%2f4ffe95AGs%2fx%2fSZXm2lgg%3d%3d 3/3 �+ In MASO �ITE. 149" MAX. OVERALL FRAME WIDTH O � ,. V p 0 WOOD-EDGE STEEL DOOR UNIT 21 MAX PANEL " MAx. 0 n D.L.O. -�- PANEL WIDTH 37.5" MAX. Q QQ 6-8 DOUBLE DOOR WITH/WITHOUT SIDELITES W/ASTRAGAL FRAME WIDTH J _ cf) GENERAL NOTES Z � ® � 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE � a- _U REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM Z DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, _ DOES NOT EXCEED THE DESIGN PRESSURES LISTED. ;� o IW- L U 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON � N Z OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELITES. � 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, _ Q F- Q Ld EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), OCb HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED 4, ON PANELS WITH NON-IMPACT GLASS. �o Z 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 L a AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING: =o TEST DESCRIPTION DESIGNATION LITE FRAME o Q o � o z SELF IGNITION TEMP ASTM D1929 842 'F > 650 'F a o,;; r¢z RATE OF BURNING ASTM D635 1.28 IN/MIN ~ J SMOKE DENSITY ASTM D2843 70.2% ,�,o u.jN W TENSILE STRENGTH* ASTM D638 1.8% DIFF m i w a�' * � COMPARATIVE TENSILE STRENGTH AFTER WEATHERING v 4500 HOURS XENON ARC METHOD 1 DOUBLE DOOR UNIT WZSIDELITES o •`" o � a C_ a z: m N J O * • • • W Ln jElo 01 11 0 O L.- Ll 11 L_ I 1 11 1 L I I I[ w cn o w Q � SINGLE DOOR UNIT DOU13LE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT W/SIDELITES DOUBLE DOOR UNIT W/SIDELITES WITH ,SIDELITE WITH SIDELITE ao � w co a 0 WHERE WATER INFILTRATION PERFORMANCE IS d DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S HIGH DAM 0 S T4 0 S HP BUMP 0 S X 37.5 +70.0 -70.0 +70.0 -70.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 +50.0 -50.0 +50.0 -50.0 XX 74 +55.0 -55.0 +55.0 -55.0 N/A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 N A N A < O z OX or XO 75 +55.0 -55.0 +55.0 -55.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 N A N A OXO 112.5 +55.0 -55.0 +55.0 -55.0 N/A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 N/A N A OXXO 149 +55.0 -55.0 +55.0 -55.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 N A N A DATE: 5126117 �1aw" / SCALE: N.T.S. TABLE OF CONTENTS AddWatoNA '^ DWG. BY: SWS CHK. BY: SHEET # DESCRIPTION KURT BALTHAZOR DRAWING NO.: 1 TYPICAL ELEVATIONS & GENERAL NOTES FLORIDA P.E. 2 ANCHORING LOCATIONS & DETAILS owd!� #56533 DWG-MA-FL0211-17 3 ANCHORING LOCATIONS & DETAILS SHEET 1 of 3 cc � 6" " SEE DETAIL 3" "6" U Q � "E" 3" 3 3" 3,. 3 3" O J I I I I I I I Q (n p — � 6' 6" 'I n 6" 6" 6" U L 6 3" co o I r Z C U M N ri L _ ^ 1- In U c, O +� I— a a SEE DETAIL co (n _ _ W J J Q SEE DETAIL _ W a SEE DETAIL w _ C B �w Of Lo A O 8 G H PoH � a � z U Cn 6" 3" _ 6" 6" I I I I f Qg$' a � 'd " o „ 3 I i 3" 3" JF3 3" 3" I� 3" 6" '1 �'i 6" 0 a SEE DETAIL #8 x 2" �m ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH #8 x 2" #10 x 5/8" THE THRESHOLD & INTO THE o STRUCTURE DEEP ENOUGH = #8 x 2„ #10 x 5/8" FOR A 1 .375" THROW w of #10 x 1 " DETAIL "E" ASTRAGAL DETAIL "F" ASTRAGAL Z #10 x 2-1/2 ATTACH ASTRAGAL RETAINER BOLT p #10 x 1 STRIKE PLATE TO FRAME w #10 x 5/8" AS SHOWN. DETAIL "C" DETAIL "D" 00 w 1 HOT MELT 0.962"1 "fT!&-7M ELASTOMER 1.375" 1 1.437 �/ #6 X 1-1/2" PHS T T T �, ,,,.. Q o INSWING THRESHOLD BUMPER 0 S THRESHOLD T4 0 'S THRESHOLD HOT MELT �� a. t/2" BITE Afendum.tuNO Z ELASTOMER `�~""�• S/26/17 1 ti R gy ' DATE: .,. ,"7 INTERIO oft SCALE: N.T.S. 1.482" 1.75" 11.047" 1.437" Egg DWG. BY: SWS TYPICAL GLAZING DETAIL T T T NON—IMPACT GLASS CHK. BY: DRAWING NO.: Z—SERIES O.ZS THRESHOLD HIGH DAM O/S THRESHOLD HP O/S THRESHOLD DWG—MA—FLO211-17 SHEET 2 OF 3 Lo SEE DETAIL 3„ 6" 6" � DO "E" SHT. 2 " 3,. " 3" � 3 3., � 3} 0O 6 — � CD Il 1 I ll I 0c 6 -� � ., 6" 6" 6" ff �I 6„ �I ;n x co cc Lo a SEE DETAIL a IW— U-) V (n „ o_ } D" SHT. 2 — — cn O � t } cl) GO SEE DETAIL � c3r "C„ SHT. 2 l J w — — w ry Li8 o m A M q � G � � Fi B e � 6" 6" — _ a W O O m O Q I O O II II 11 Il I ' � � 3" f " "� sow N o .8 3 I � o ¢ 3" 'I 3„6 6 3„ f'"' 3 SEE DETAIL co o ¢z "F" SHT. 2 6" 6,. g" 0 F- 0 a HARDWARE SCHEDULE a ° In 1 . KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND �m SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. o ATTACHMENT DETAIL 1.25" , '�- : ; 2. 4" X 4" FULL MORTISE BUTT HINGES. o MIN # Ir . S. _ 1 . ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, ~M;vC 1"x1/2" CORRUGATED #10X2" WOOD SCREW w SIGNED AND SEALED BY ROBERTO LOMAS, PE SHIM 3" FROM EACH END 6" FROM EACH ENDof (FLORIDA #62514) WITH THE LOWEST (LEAST) AND 7" OC AND 12" OC Z FASTENER RATING FROM THE DIFFERENT FASTENERS CL ~I I+ '; w o o BEING CONSIDERED FOR USE. JAMB, HEAD, AND ACRYLIC o THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CAULK #10 WOOD SCREWS OR 1/4 TAPCONS. A PHYSICAL TYPICAL MASONRY ACRYLIC SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR ANCHOR INSTALLATION LATEX — 00 w LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". CAULK _ CL � a WOOD SCREW EDGE DISTANCE MIN 3/4". o •;o: v _ COMBINATION WOOD COMBINATION WOOD 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM 1.50" a g MULLION (BOXED) MULLION (BOXED) ANSI/AF&P,A NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT MIN Mom" (3) #10X2-1/2" ¢zo OF 1 -1/2 MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE SHIM WOOD SCREWS MINIMUM EMBEDMENT OF 1 -1/4". I EACH END AbmdntoNAM CL If � DATE: Jr/ZB11 7 .:. 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO ® Rev�C8fpf9E�0�1.NQedBy: SCALE: N.T.S. TRANSFER LOADS TO STRUCTURE. 0 now ( DWG. BY: SWS 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. ® ® CHK. BY: TYPICAL WOOD BUCK ANCHOR INSTALLATION DRAWING NO.: INTEGRAL WOOD DWG-MA-FLO211-17 MULLION (CHS) SHEET 3 OF 3