Loading...
HomeMy WebLinkAbout630 FT PIERCE - 01 CS Coversheet4946 S 25TH ST FORT PIERCE FL 34981 POPEYES LOUISIANA KITCHEN LK 1246-DL SAILORMEN VERDAD REAL ESTATE, INC 1211 SOUTH WHITE CHAPEL BLVD SOUTHLAKE TX 76092 CONTACT: JOE MANN SR. PHONE: 985-705-3305 VERIFY ALL SERVICE REQS. W/ THE LOCAL UTILITY CITY AGENCIES. WASTE SERVICE: 4" DIAM. FIXTURE UNIT COUNT: 80 FU 1,600 GALLONS/DAY LANDSCAPING: (VERIFY WITH OWNER IF USED) SIZE PER ZONE - REFER TO PLAN FOR DESIGN. WATER SERVICE:1 1/2" DIAM. FIXTURE UNIT COUNT: 38 FU WATER SERVICE:2,000 GALLONS/DAY 2" CONDUIT 25 PAIR WIRE (OWNER REQUIREMENT) POWER: 208V / 3 PHASE /4W / 800 AMPS. TOTAL CONNECTION LOAD: 345.16 KVA TOTAL DEMAND LOAD: 247.74 KVA NOTE: SEE SHEET E3 FOR BREAKDOWN OF THE ELECTRICAL SERVICE CONNECTED LOAD LIS ARCHITECTURE 2572 WEST STATE ROAD 426 SUITE 2064 OVIEDO, FL 32765 CONTACT: GEORGE MELLA PHONE: 321-244-0402 LIS ENGINEERING 2572 WEST STATE ROAD 426 SUITE 2064 OVIEDO, FL 32765 CONTACT: CLARK STILWELL PHONE: 321-244-0402 LIS ENGINEERING 2572 WEST STATE ROAD 426 SUITE 2064 OVIEDO, FL 32765 CONTACT: ROBERT CASE PHONE: 321-244-0402 KITCHEN (NET):984 S.F. WALK-IN (NET):157 S.F. DINING/RESTROOM (NET):1,006 S.F. TOTAL (NET):2,147 S.F. TOTAL BUILDING AREA:2,265 S.F. BUILDING HEIGHT:40'-0" ALLOWABLE 19'-8" PROVIDED TOP CHORD (ROOF) DEAD LOAD:10 psf LIVE LOAD:20 psf ADDT. EQUIP. LOAD:AS SHOWN BOTTOM CHORD (CLG) DEAD LOAD:10 psf TOTAL DESIGN LOAD:40 psf WIND SPEED:(VERIFY W/ STRUCTURAL DRAWINGS) DINING AREA DOOR #1 @ 6'-0" = 72" DOOR #3 @ 3'-0" = 36" KITCHEN DOOR #4 @ 3'-6" = 42" REQUIRED (PER OCCUPANTS)PROVIDED MEN WOMEN MEN WOMEN WC 1/75 1/75 WC 1 1 LAV 1/200 1/200 LAV 1 1 EQUIPMENT WASSERSTROM ALICIA O'NEAL 614-737-8570 SIGNAGE CAPITAL SIGNS AND AWNINGS JUDY CHENEVERT 318-346-9898 SEATING SEATING CONCEPTS KERRY STUDER 815-730-7980 X2223 SITE LIGHTING SECURITY LIGHTING WHITNEY ILG 800-544-4848 X131 VICINITY MAP "H" COUNTER:14 BOOTH SEATING:18 WALL BENCH:7 TABLES/CHAIRS:8_ TOTAL SEATING:47 BOHLER ENGINEERING 2255 GLADES ROAD BOCA RATON, FL 33431 CONTACT: CHRISTOPHER ROGERS, P.E. PHONE: 561-571-2080 NAME:ST. LUCIE COUNTY PLANNING AND DEVELOPMENT DEPARTMENT - PERMITTING/ZONING ADDRESS:2300 VIRGINIA AVENUE, FT. PIERCE, FL 34982 CONTACT:MONICA GRAZIANI - MANAGER BUILDING & CODE REGULATIONS PHONE:772-462-1553 EMAIL:GRAZIANIM@STLUCIECO.ORG REVIEW:FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION DIVISION OF HOTELS AND RESTAURANTS (DBPR) ADDRESS:2601 BLAIR STONE ROAD TALLAHASSEE, FL 32399 CONTACT:CALL TO SWITCHBOARD - REVIEWER WILL BE ASSIGNED WHEN PLANS ARE SUBMITTED PHONE:850-487-1395 FAX:850-921-8267 EMAIL:DHR.PLANREVIEW@MYFLORIDALICENSE.COM REVIEW:ST LUCIE COUNTY FIRE DISTRICT ADDRESS:5160 NW MINER DR, PORT ST LUCIE, FL 34983 CONTACT:KELLY MACHADO PHONE:772-621-3400 FAX:772-621-3604 EMAIL:KMACHADO@SLCFD.ORG BUILDING CODE: 2017 FLORIDA BUILDING CODE, 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE, 6TH EDITION 2012 NFPA 101 ELECTRICAL: NATIONAL ELECTRICAL CODE, 2011 EDITION PLUMBING: 2017 FLORIDA BUILDING CODE, PLUMBING, 6TH EDITION MECHANICAL: 2017 FLORIDA BUILDING CODE, MECHANICAL, 6TH EDITION GAS:2017 FLORIDA BUILDING CODE,FUEL GAS CODE, 6TH EDITION ENERGY: 2017 FLORIDA BUILDING CODE,ENERGY CONSERVATION, 6TH EDITION ACCESSIBILITY: 2017 FLORIDA BUILDING CODE, ACCESSIBILITY, 6TH EDITION OCCUPANCY CLASSIFICATION:ASSEMBLY A-2 (RESTAURANT) BUILDING OCCUPATION LOAD:54 (BASIS: SEATING, EMPLOYEES CONSTRUCTION CLASSIFICATION:TYPE V-B - UNPROTECTED, UNSPRINKLERED NAME:CITY OF FORT PIERCE UTILITIES AUTHORITY ADDRESS:206 S 6TH ST., FORT PIERCE, FL 34950 CONTACT:EILEEN M. SNOBERGER PHONE:772-466-1600 X3283 FAX:772-467-3115 EMAIL:KEYMAIL@FPUA.COM NAME:SOUTH FLORIDA WATER MANAGEMENT DISTRICT (SFWMD) ADDRESS:3301 GUN CLUB RD, WEST PALM BEACH, FL 33406 CONTACT:JAYNE BERGSTROM PHONE:772-223-2600 X3602 EMAIL:JBERGSTR@SFWMD.GOV NAME:AT&T ADDRESS:11760 U.S. HWY 1 N, PALM BEACH GARDENS, FL 33408 CONTACT:DINO FARRUGGIO PHONE:561-998-0240 EMAIL:DF1979@ATT.COM NAME:ST. LUCIE COUNTY FIRE DISTRICT ADDRESS:5160 NW MINER DR, PORT ST LUCIE, FL 34983 CONTACT:LISA HANNOLD PHONE:772-621-3352 EMAIL:LHANNOLD@SLCFD.ORG NAME:FLORIDA POWER & LIGHT ADDRESS:1401 SE MONTEREY RD, STUART, FL 34994 CONTACT:ARMLIGHT MARJAN PHONE:772-337-7025 EMAIL:ARMLIGHT.MARJAN@FPL.COM REVIEW:ST. LUCIE COUNTY ROAD DEPARTMENT ADDRESS:3071 OLEANDER AVE, FT PIERCE, FL 34982 CONTACT:LINDA BUCHANAN PHONE:772-462-1707 EMAIL:BUCHANAN@STLUCIECO.ORG CS GM HDH COVER SHEETARCHITECT / ENGINEERCLIENT NAMEPROJECT NAMESHEET TITLESEAL RELEASE PROJECT NO. ISSUE DATE DRAWN SHEET NO.LIS EXPRESSLY RESERVES ITS COPYRIGHT AND ALL OTHER PROPERTY RIGHTS TO THESE DOCUMENTS AND THEIR DESIGN, HENCE, THEY ARE NOT TO BE REPRODUCED.DATE CHECKED21430 Palm Beach BlvdAlva, FL 33920Phone: (239) 693-9244Facsimile: (239) 693-98282572 West State Road 426Suite 2064, Oviedo, FL 32765Phone: (321) 244-0402Facsimile: (321) 244-9419ARCHITECTUREENGINEERINGAA 26002040 CA NO.: 6853 LB1057LISLAND INVESTMENT SERVICES, LLC2018-002 12/21/18POPEYESLK 1246-DL SAILORMEN4946 S 25th STFORT PIERCE, FL 34981VERDAD REAL ESTATE, INC1211 SOUTH WHITE CHAPEL BLVDSOUTHLAKE TX 76092COMMENT RESPONSE 03/28/19 KITCHEN REVISION 06/26/19 OWNER REVISION 01/02/20 CIVIL COORDINATION 02/21/20 EDGE PROTECTION 04/29/20 VENDOR COORD.05/05/20 HAROLD DANIEL HUTTER III FL. REG. 98913 LEGEND BRACKET COVER BY P.O.S. VENDOR A.F.F. EL. 9'-4" S.S. STEEL BRACKET MONITOR MONITOR ASSEMBLY 2. 1. (NOT SHOWN) CONCEAL SLEEVE TO POWER CORDS CHANNELS & WHT. PLASTIC ATTACH BOLTS W/ (2) 1/4" BRACKET MONITOR CHANNEL OUTER STEEL CEILING TILE PLATE FLASHING INNER STEEL CHANNEL (2) 1/2" U-BOLTS OR JOISTS TOG.C. TO ROOF TRUSSES "U" HANGERS @ EA. END TO RAFTER PLATE W/ SIMPSON DBL. 2X4 BLOCKING NOTES: MONITOR BRACKETS TO BE SUPPLIED AND INSTALLED BY P.O.S. VENDOR. G.C. TO SUPPLY 2x4 BLOCKING AND TO SECURE BLOCKING AT LOCATION PER P.O.S. VENDOR DIRECTION. VERIFY W/ P.O.S. VENDOR BEFORE INSTALLATION REGISTER CONNECTIONS 1.CABLES SHALL BE COAX. 2.BUMP BARS SHALL BE MOUNTED TO DELIVERY SYSTEM AT AREAS MARKED "BB". 3.BUMP BAR CABLES SHALL BE RUN THROUGH DELIVERY SYSTEM FROM MOUNT UP THROUGH WALLS TO ABOVE THE CEILING AND BACK TO THE MANAGER STATION. 4.CRT MONITORS SHALL BE MOUNTED ON CEILING BRACKETS PROVIDED BY REGISTER SYSTEM. 5.WHERE CABLING IS INSTALLED IN WALLS, IT SHALL BE ROUTED IN A 1" CONDUIT THROUGH WALL TO ABOVE ACCESSIBLE CEILING. BUMP BAR WIRING VIDEO MONITOR AND POS WIRING SECURITY WIRING BB - BUMP BARS V1 = VIDEO 1 V2 = VIDEO 2 V3 = VIDEO 3 POS- POINT OF SALE TERMINAL CRT ABOVE CEILINGSPEAKER POST MENU BOARD LV JUNCTION BOX J COORDINATE DSL CONNECTION UNDERGROUND CONDUIT FOR HEADSET CABLING. CABLE IS SUITABLE FOR WET LOCATIONS. E4 P.O.S. WIRING DIAGRAME4 1 E4 2 ARCHITECT / ENGINEERCLIENT NAMEPROJECT NAMESHEET TITLESEAL RELEASE PROJECT NO. ISSUE DATE DRAWN SHEET NO.LIS EXPRESSLY RESERVES ITS COPYRIGHT AND ALL OTHER PROPERTY RIGHTS TO THESE DOCUMENTS AND THEIR DESIGN, HENCE, THEY ARE NOT TO BE REPRODUCED.DATE CHECKED21430 Palm Beach BlvdAlva, FL 33920Phone: (239) 693-9244Facsimile: (239) 693-98282572 West State Road 426Suite 2064, Oviedo, FL 32765Phone: (321) 244-0402Facsimile: (321) 244-9419ARCHITECTUREENGINEERINGAA 26002040 CA NO.: 6853 LB1057LISLAND INVESTMENT SERVICES, LLC2018-002 12/21/18POPEYESLK 1246-DL SAILORMEN4946 S 25th STFORT PIERCE, FL 34981VERDAD REAL ESTATE, INC1211 SOUTH WHITE CHAPEL BLVDSOUTHLAKE TX 76092COMMENT RESPONSE 03/28/19 KITCHEN REVISION 06/26/19 OWNER REVISION 01/02/20 CIVIL COORDINATION 02/21/20 EDGE PROTECTION 04/29/20 VENDOR COORD.05/05/20 FLORIDA PE. #44643 ROBERT WAYNE CASE P.O.S. WIRING DIAGRAM 24"x60" 4-TIER 24"x60" 4-TIER 24"x72" 5-TIER 24"x60"4-TIER24"x54"5-TIER24"x48" 5-TIER 21"x54"5-TIER24"x60" 5-TIER 24"x60" 5-TIER ELECTRICAL REQUIREMENTS ELECTRICAL SUPPLY ALL 120 VAC FOR CAMERA SYSTEM AND BURGLAR ALARM SYSTEM SUPPLY 120 VAC FOR ALL CCTV HEAD END EQUIPMENT. SUPPLY 120 VAC FOR BURGLAR ALARM PANEL. FOR OUTDOOR CAMERAS ALL TRENCHING, CONDUIT AND PULL STRINGS, AS WELL AS A BACK BOX MOUNTED ON THE POLE FOR ELECTRICAL AND COAX CONNECTIONS. SECURITY CO. SUPPLY AND INSTALL ALL SECURITY EQUIPMENT RUN ALL LOW VOLTAGE CABLE FOR THE SECURITY SYSTEM. SET UP, TEST AND TRAIN ON CCTV AND BURGLAR ALARM SYSTEMS. SPECIFY ALL LOCATIONS OF DEVICES. VERIFY LOW VOLTAGE PERMIT REQUIREMENTS HOLD-UP BUTTON M-12 S/S MANAGER'S DESK CCTV CAMERA DEVICE LEGEND SYMBOL QTY.NOTE DVR DVR 15 1 ALL CAMERA CABLES RUN BACK TO DVR SECURITY PLAN1Scale: 1/4"=1'-0" PANIC BUTTON5 ARCHITECT / ENGINEERCLIENT NAMEPROJECT NAMESHEET TITLESEAL RELEASE PROJECT NO. ISSUE DATE DRAWN SHEET NO.LIS EXPRESSLY RESERVES ITS COPYRIGHT AND ALL OTHER PROPERTY RIGHTS TO THESE DOCUMENTS AND THEIR DESIGN, HENCE, THEY ARE NOT TO BE REPRODUCED.DATE CHECKED21430 Palm Beach BlvdAlva, FL 33920Phone: (239) 693-9244Facsimile: (239) 693-98282572 West State Road 426Suite 2064, Oviedo, FL 32765Phone: (321) 244-0402Facsimile: (321) 244-9419ARCHITECTUREENGINEERINGAA 26002040 CA NO.: 6853 LB1057LISLAND INVESTMENT SERVICES, LLC2018-002 12/21/18POPEYESLK 1246-DL SAILORMEN4946 S 25th STFORT PIERCE, FL 34981VERDAD REAL ESTATE, INC1211 SOUTH WHITE CHAPEL BLVDSOUTHLAKE TX 76092COMMENT RESPONSE 03/28/19 KITCHEN REVISION 06/26/19 OWNER REVISION 01/02/20 CIVIL COORDINATION 02/21/20 EDGE PROTECTION 04/29/20 VENDOR COORD.05/05/20 FLORIDA PE. #44643 ROBERT WAYNE CASE E5 SECURITY PLAN 24"x60" 4-TIER 24"x60" 4-TIER 24"x72" 5-TIER 24"x60"4-TIER24"x54"5-TIER24"x48" 5-TIER 21"x54"5-TIER24"x60" 5-TIER 24"x60" 5-TIER ELECTRICAL REQUIREMENTS ELECTRICAL SUPPLY ALL 120 VAC FOR CAMERA SYSTEM AND BURGLAR ALARM SYSTEM SUPPLY 120 VAC FOR ALL CCTV HEAD END EQUIPMENT. SUPPLY 120 VAC FOR BURGLAR ALARM PANEL. FOR OUTDOOR CAMERAS ALL TRENCHING, CONDUIT AND PULL STRINGS, AS WELL AS A BACK BOX MOUNTED ON THE POLE FOR ELECTRICAL AND COAX CONNECTIONS. SECURITY CO. SUPPLY AND INSTALL ALL SECURITY EQUIPMENT RUN ALL LOW VOLTAGE CABLE FOR THE SECURITY SYSTEM. SET UP, TEST AND TRAIN ON CCTV AND BURGLAR ALARM SYSTEMS. SPECIFY ALL LOCATIONS OF DEVICES. VERIFY LOW VOLTAGE PERMIT REQUIREMENTS HOLD-UP BUTTON M-12 S/S MANAGER'S DESK CCTV CAMERA DEVICE LEGEND SYMBOL QTY.NOTE DVR DVR 15 1 ALL CAMERA CABLES RUN BACK TO DVR SECURITY PLAN1Scale: 1/4"=1'-0" PANIC BUTTON5 ARCHITECT / ENGINEERCLIENT NAMEPROJECT NAMESHEET TITLESEAL RELEASE PROJECT NO. ISSUE DATE DRAWN SHEET NO.LIS EXPRESSLY RESERVES ITS COPYRIGHT AND ALL OTHER PROPERTY RIGHTS TO THESE DOCUMENTS AND THEIR DESIGN, HENCE, THEY ARE NOT TO BE REPRODUCED.DATE CHECKED21430 Palm Beach BlvdAlva, FL 33920Phone: (239) 693-9244Facsimile: (239) 693-98282572 West State Road 426Suite 2064, Oviedo, FL 32765Phone: (321) 244-0402Facsimile: (321) 244-9419ARCHITECTUREENGINEERINGAA 26002040 CA NO.: 6853 LB1057LISLAND INVESTMENT SERVICES, LLC2018-002 12/21/18POPEYESLK 1246-DL SAILORMEN4946 S 25th STFORT PIERCE, FL 34981VERDAD REAL ESTATE, INC1211 SOUTH WHITE CHAPEL BLVDSOUTHLAKE TX 76092COMMENT RESPONSE 03/28/19 KITCHEN REVISION 06/26/19 OWNER REVISION 01/02/20 CIVIL COORDINATION 02/21/20 EDGE PROTECTION 04/29/20 VENDOR COORD.05/05/20 FLORIDA PE. #44643 ROBERT WAYNE CASE E5 SECURITY PLAN