HomeMy WebLinkAboutProduct approvals Florida Building Code Online Page 1 of 4 rn T [it ^ ness & Professional Regulation i BCIS Home Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search dbor FL20468.5 THERMATRU FIBER CLASSIC AND SMOOTH STAR . Product Approval Nominal 8'0"Impact"Opaque Composite Edge Fiberglass USER:Public User Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL20468-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,OH 43517 (419)298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King,P.E. 9 Validation Checklist-Hardcopy Received Certificate of Independence FL20468 R3 COI (c)Certificate of Independence.odf Referenced Standard and Year(of Standard) Standard Year AAMA/W D MA/CSA 101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1886 2002 ASTM E1996 2009 ASTM E1996 2006 ASTM E1996 2002 ASTM E1996 2005 ASTM E330 2002 TAS 202 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL20468 R3 Epuiv EQUIVALENCY OF STANDARDS.pdf https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJ... 5/13/2020 Florida Building Code Online Page 2 of 4 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/09/2018 Date Validated 10/11/2018 Date Pending FBC Approval 10/21/2018 Date Approved 12/11/2018 Summary of Products FL# Model,Number or Name Description 20468.1 a.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.1 for Design Pressure Ratings,any FL20468 R3 AE (c)Eval 20468.1.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.2 b.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.2 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.2.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"I" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.3 c.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.3 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.3.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.4 d.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.4 for Design Pressure Ratings,any FL20468 R3 AE (c)Eval 20468.4.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.5 e.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJ... 5/13/2020 Florida Building Code Online Page 3 of 4 Lim:within Use Installation Instructions Apd for use in HVHZ:No FL20468 R3 II (e)Inst 20468.5.pdf Apd for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 ImResistant:Yes Created by Independent Third Party:Yes Deressure:N/A Evaluation Reports Otee INST 20468.5 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.5.pdf add use limitations,installation instructions and product Created by Independent Third Party:Yes P. (For Fiber Classic and Smooth Star Door and Sidanels,this product approval requires the use of"I" parters for these doors,which have been stained or paiithin six months of installation.) 20468.6 f.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.6 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.6.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"I" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.7 g.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.7 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.7.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.8 h.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.8 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.8.pdf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.9 FThe -Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass tar Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.9.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.9 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.9.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.10 j.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.10 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.10.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJ... 5/13/2020 Florida Building Code Online Page 4 of 4 this product approval requires the use of"I"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.11 FkThermaTru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass ooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.11.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.11 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.11.Ddf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"I" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.12 FITherma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass ooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.12 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.12.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"I" part numbers for these doors,which have been stained or painted within six months of installation.) Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Z IL J eC6eck M Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJ... 5/13/2020 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product / Report Report / 0468 Deceinher 5,2017 Product Sub Category Manufacturer Product Name Category Therma Tru Corporation Fiber-Classic and Smooth-Star Exterior Swinging Exterior Door 118 Industrial Drive Composite Edge Opaque Fiberglass Single Door w/Sidelites Doors Assemblies Edgerton,OH 43517 Inswing/Outswing Phone 419.298.1740 "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E.for Therma Tru Corporation based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017) Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM El996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468.5 require further engineering analysis by a licensed engineer or registered architect. 6. Fiber-Classic&Smooth-Star Door and Sidelite panels require the use of"J"part numbers and must be stained or painted within six months of installation 7. See drawing FL-20468.5 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 06-0831-1 AAMA/WDMA/CSA101/I.S.2/A440-05 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E1886-02, E1996-02 TEL 01460274 ASTM E1886-05, E1996-05 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E330-02, E331-00 TEL 01460440A ASTM E1886-05, E1996-06, E330-02 Testing Evaluation Lab.,lnc. V.K.Wright TEL 01460131 ASTM E1886-02, E1996-02 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E330-02, E331-00 TEL 01461612 ASTM E1886-05, E1996-09 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E330-02, E331-00 TEL 01461939 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc V.K.Wright ASTM E1886-05, E1996-09 2. Miami Dade NOA Materials Testing 16-1117.01 Butacite®PVB Interlayer(Kuraray) 17-0712.05 Saflex®PVB Interlayer(Eastman Chemical Company) 3. Drawing No. Prepared by Signed&Sealed by 4. Cal ul ti0ons 5 Prepared bRW yConsultants, Inc. (CA#9813) ,0000�� ��F•efd�r���a�®A Signed&Sealed by Lyndon F.Schmidt, P.E. e fir' •' ^a Anchoring RW Building Consultants, Inc. (CA#9813) �� ;•�,�C S� �.�ndon F. Schmidt, P.E. 5. Quality Assurance No 43409 /•� e Q Certificate of Participation issued by National Accreditation and Management Institute, certifying that Therma Tru Corporation is 3-yndon F.Schmidt,P.E. manufacturing products within a quality assurance program that complies �� 1 FL PE No.43409 with ISO/IEC 17020 and Guide 53. STATE OF a:�o 12/14/2017 Sheet 1 of 1 ��T r" • 1. .` fiS.L O R t�7.. °�.tee. ERMAI TH TRtJ DOORS �':: z ;:o Fiber-Classic. & Smooth-Star. � o``,`•`` � � m00 co r r� U N Cp Z N 01. .0 U x Z Q O Ea Z m m U COMPOSITE EDGE 76"MAX.FRAME WIDTH 114.25"MAX.FRAME WIDTH a (n M 5 q r m It, 0. 0. U. co OPAQUE FIBERGLASS SINGLE DOOR 0.75" 0.75" 0.75" o ko CD 37.75'MAX. 37.5'MAX. 37.5"MAX. 37.75'MAX. v°Lj Z W/ SIDELITE(S). FRAME WIDTH FRAME WIDTH FRAME WIDTH' FRAME WIDTH o _>j,a INSWING/OUTSW/NG Z "IMPACT" 93 ,,� ,�� LA ;�� o N GENERAL NOTES _ ' �o o Z z z N 1. This product has been evaluated and is in compliance with the 6th Edition(2017) Florida `tom ¢0 Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone" q ` �g m �' m (HVHZ). O �m ¢U � = a a Q 0 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment W o ci��„ to base material shall be beyond wall dressing or stucco. o W � _ ® o a a with FBC 3. When used in areas requiring wind bome debris protection,this product complies w Q o Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This Y Y m product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996 and m FBC Sections 1609.1.2.2&R301.2.1.2.1. z N 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown z QLn m for 2x buck masonry construction. o° Z G NW IN (n 0 5. Site conditions that deviate from the details of this drawing require further engineering z z analysis by a licensed engineer or registered architect. ; �, a w o z N OD J W N 6. Fiber-Classic&Smooth-Star Door and Sidelite panels require the use of"J"part numbers o o w o and must be stained or painted within six months of installation. oo � � 2 TABLE OF CONTENTS �, o z o� Ej C cC ¢ ¢ � z SHEET# DESCRIPTION ao n 1 Typical Elevations,Design Pressures&General Notes ^ w 2 Door Panel Details DESIGN PRESSURE(PSI) DESIGN PRESSURE(PSI) o'� �_ �-- c 3 Sidelite Panel Details INSWING OUTSWING CONFIGURATION " 5 Horizontal&Vertical Cross Sections(2X Buck) POSITIVE NEGATIVE POSITIVE NEGATIVE ')a o 0 Z v F 6 Horizontal&Vertical Cross Sections(1 X Buck) ( 50.0 -50.0 50.0 -50.0 �� 8/02 16 W 7 Horizontal&Vertical Cross Sections Direct to Masonry) XO OX OXO ♦ + Z sue: N.T.S. < B Vertical Cross Sections(Thresholds) W 9 Buck Anchoring DWG. JK m' 10 Frame Anchoring See Sheet 4 for Hardware Specifications cHK. BY: LFS 3 11 Hardware Details DRAWING NO.: 12 Glazing Details FL-20468.5 i0 13 Components o cu 14 Bill of Materials sH�r 1 of 14 O U ``��iiill►tt��j EXTERIOR EXTERIOR ��'. • o `� m 0.5" 3.6' _ g:o' 0.406' 3.6" = U u=i 'k : 0.7' 0.5 0. " 0.406" N:: z �C:�cpwO "- ... •, °� j °> is // I• • �iGV-`ti Z U aj00 t') 00 rn 11100 0 0 _ COMPOSITE COMPOSITE r N z CAP CAP o ° o x z a N COMPOSITE HINGE STILE LOCK STILE COMPOSITE HINGE STILE LOCK STILE 00. c 0 o m c w CAP (ENGINEERED WOOD) INTERIOR (ENGINEERED WOOD) CAP (ENGINEERED WOOD) (ENGINEERED WOOD N 5 o z m ) a INTERIOR � m n aLL O C O 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION w N J LL Z Lli U _J CC Q N TOP RAILco (COMPOSITE/ENGINEERED 36.0"MAX. 35.813"MAX. 35.813"MAX. WOOD) w� w °¢- DOOR DOOR DOOR — �m o 3 PANEL WIDTH PANEL WIDTH PANEL WIDTH O a o 01 2 2 2 v 01 a a 0 0 � m FOAM CORE (POLYURETHANE- � Z o 1.9 PCF MIN.) z ci ¢ m ' ooz � INTERIOR EXTERIOR 10 a^ o o W W W INTERIOR EXTERIOR o ^ z o 0 w uj o w coD W W 2 Z 2 • ,i'.t � Jwco W Z Q p q p O to N ¢ 2 2 a 2 0:: Lou p LO p L6 p oa ';..;'_; ' `\\� FIBERGLASS SKIN Oq o o to o a p o (0.082 THK.) �.'" �' �i o z 0 o a x O X O x O +''' rr ¢ ¢ o z a O O O t � ^ ul o `^ � Q F o LO u� `o LO LO a BOTTOM RAIL o o LL —.- (COMP.) N 01 1.71" 1.71" ^ Z U M N uj 3 VERTICAL CROSS SECTION 4 VERTICAL CROSS SECTION DATE: 08102116 2 SCAM N.T.S. o DWG. Bar: JK D D D cHK. sir: LFS _ DOOR PANEL DRAWING NO.- DOOR DOOR PANEL DOOR PANEL 42 FL-20468.5 0 BOOK Hybrid Door U1 Door SHEET 2 of 14 N _ OO v — — U K EXTERIOR �'` I •dam 0.66" G1 O.bb" TOP RAIL 1 =U• (COMP) z , 10 J > u)— In fL, + • z o ,t �t co o 0te) ODz o, t0' U N 0 x Z 4 OO -0 v STILE(WOOD) STILE(WOOD) FOAM CORE E E a o m v 3 INTERIOR (POLYURETHANE- C V o a 0 1.9 PCF MIN.) a Enm a a 14:co 1 HORIZONTAL CROSS SECTION `` o c�3 =z N O =W 0 J D. z uj v 36"MAX. cn C PANEL WIDTH —'—Q N �p `° Z w <t w 3 EXTERIOR INTERIOR m o / v c o / o �n 0 F a a a G1 M a �0 o � 6 4 is (U �] O c;0 = w d N W N U) O °a o 3 z "'°¢ W v ko << (<L to C> m CN J to O Q i O W W m a 0 0 4 n � Q Q D z t FIBERGLASS SKIN ��/ (0.082 THK.) o o �. Li o BOTTOM RAIL z LL (COMP) ro N z 0 z n DATE: 08102116 z z SCALE: N.T.S. xDWG. BY. X m 2 VERTICAL CROSS SECTION CHK. BY. LFS F DRAWING NO.: 50 S►DELtTE PANEL 3 m FL-20468.5co 0 N SHEET 3 DF 1 4 v u ``��{11111►/ll� I 3 3 3 4 4 4 3 3 3 4 4 4 _ g'`�' Lh 5 6 7 5 6 7 5 6 7 5 6 7 Z ©~ - (� �� �• �� Q 0ILA 1111 � M J j/ /%/ /// ���► i 11co z c O o O to z a m +, UN .. 2 0 p xZq v 5 ° C0 0 0 v aNM =' oaa 1 v 2 a.r2 � maam 5 6 5 v 5 E oZ N 2 5 2 0 �a 6 70 0 6 1 2 7 ® 6 7 Cr C� 6 N X 5 X 5 po z 0 k �V) Q � W .3 O . 0 0 v a a .N E- �c �c >- D 4 D 4 D 4 � m p d v C 1 2 3 4 5 6 1 2 3 4 5 b or $ 8 8 8 8 8 8 $ 8 8 8 8 zm Ln v p O Z rz K SEE HARDWARE CHART SEE HARDWARE CHART h-C d N O •- z z 's 41u� o W co Q J W N DrM f20 Of J O W I.- 0 Q' Q 0 0 CL HARDWARE TABLE Q Q Z _ _ MANUFACTURER MQDEL o Q � a SCHLAGE KNOB: F51 ^ o a d DEADBOLT: B60 "' N z o z DATE: 08/02/16 z Z KNOB: SIGNATURE SERIES o N.T.S.Fiber-Classic/Smooth-Star Door Panel Options KWIKSET DEADBOLT: SIGNATURE SERIES(980) SCALE. Products approved include all embossed and recessed panel doors. DWG. X m Similar opaque panel configurations are allowed. HOPPE MULTIPOINT:MPDGART CHK. BY: LFS Panels shown are for illustration and are representative only. (THERMA-TRU) (3 pt.Manual Tongue) DRAWING No.: FL-20468.5 - SHEET 4 of 14 v d 1.15"MIN. Notes: EMB. (TYP.) 1.Sidelite assembly screws located 6'from Z.Q; •.•'fig f E each end and 6 more screws equally spaced Z Z s:�W E between(8 screws total per side jamb). = g: A ©� =, to B C 2.Sidelite assembly screws located 3"from each = W. o * < �i--Z d 8 end&at centerline(3 screws along head jamb). ; Z '�� rn y� ►� orn o4 0.15"C-SINK C6 4 D ♦i♦♦♦ • 0 ! > (TYP) 0.15 C-SINK _ Il�� 1111 �� � ►� d (TYP) D p p v ° C° O M °° Z z D Em Z m U p D ° p .p °p. ..v Y tl't 0 C W e ° SEE NOTE 1 ° ° p a N 5 d d m 6 _ y � o INTERIOR 25 .. / VD ' Z CL 3 V :�t IndC Li +� a: N d-p ° _ 0 Jan. p n� ° ° w L O . ° d 23 24 EXTERIOR 40 41 42 �� m ¢� 50 D 7 1 N w0 W ' =o: En ov) EMB.(TYP.) L 29 40 41 42 1-1/4"MIN. EXTERIOR INTERIOR � '" ~ Cn 6 oL" o EMB. (TYP.) o Z) o 2:0 Of 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION x 3 VERTICAL CROSS SECTION 5 Shown w/2X Buck 5 Shown w/2X Buck Shown w/2X Buck a Outswingshown (Inswing similar Y } ( 9 ) Outswing shown (Inswing similar) Outswing shown (Inswing similar) > > m U Id 88 1 88 D o m 1 1 ` 1 L FY E p p p O$ Z Q OLU ZN Z G p p v ° 41 [] W SEE NOTE 1 SEE NOTE 1 v a w o 0 7 25 o v, '� N 25 b B z CO o_ fo 40 41 42 L 000 a `W o a � �= ¢ ¢ � C z F O 25 Q Q SEE NOTE 2 � o a NI IZIU 50 z DATE: O8 o2/1 6 i UJ L 50 -- 50 23 24 27 25 U scatE N.T.S. ° 40 41 42 EXTERIOR INTERIOR �' V DWG. BY: ,JK m 29 3 � cHK. Br: LFS 5 HORIZONTAL CROSS SECTION 4 VERTICAL CROSS SECTION Q HORIZONTAL CROSS SECTION DRAWING NO Outswing shown (Inswing similar — — 5 Shown w/2X Buck FL-20468.5 N 5 9 ( 9 ) 5 Outswing shown (Inswing similar) Outswing shown (Inswing similar) SHEET 5 OF 14 v Notes: `��'�.• � .t���; 1.Sidelite assembly screws located 6"from each end and 6 more screws equally spaced J =_: ' o'; ,•1: between (8 screws total per side jamb). _ (�:c �r (fit ; n 2.Sidelite assembly screws located 3"from each N;7 ZLL �o �:p r end &at centerline(3 screws along head jamb). E ° o o ��;., •;r yy`(A a (�CO z Opp 6 _ a U N Z CD A C z � o E z 0o A `2 aso 00° E `LLm, n _� o oa C E ° m o: a � O 0 O 00 00 40 41 42 E Z .� l v C lil C) C o >a w as D o° 7 1 J ° Um D' 1 EXTERIOR INTERIOR ¢� Q�X 50 D 6 3 VERTICAL CROSS SECTIONap G INTERIOR 6 Shown w/ 1X sub-buck =W U) ow Cn Outswing shown (Inswing similar) �-m Q Nv) o a U 0 Oo a v a a D v CC] a a ° E ° EXTERIOR 7 23 25 0 ° o o ° - °: o o m z v) SEE NOTE 1 ° n ° ° ►`z o zooms 1-1/ "MIN. 40 41 42 A MIN. 29 0 o z fff ~= o EMB. (TYP.) 1 O N Z N z 1-1/4"MIN. -- w T a ' o 00 EMB. (TYP.) A C nz¢ U) CD 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION W o cn oow �o 6 Shown w/ 1 X sub-buck 6 Shown w/ 1 X sub-buck 25 "' o o Outswing shown (Inswing similar) Outswing shown (Inswing similar) a SEE NOTE 2 o �iozo a Q Q z CO N 0 1 w z Q J EXTERIOR INTERIOR o N z U L DAT: 08102116 z 4 VERTICAL CROSS SECTION scAIE: N.T.S. J a5 Shown w/ 1 X sub-buck DWG. BY: JK m 2 Outswing shown (Inswing similar) cHK. BY: LFS 3 E DRAWING NO.: FL-20468.5 0 cq SHEET 6 of i 4 �`1111Ai vs ttl MAX. MAX. =g:4 o ..i= to E w MIN. E w MIN. W.: z° tc';: O r r v t 1 11� 11 o M CO z° C C ak .� VN .. n o .0 :2 Z X Z Q E 0> NQ C r Crp O 40 41 42 a CO25 o WV ko lzrSEE NOTE 2 Z 0 C W J EXTERIOR INTERIOR EXTERIOR INTERIOR a z Ui 0= v QO 3 HORIZONTAL CROSS SECTION 4 VERTICAL CROSS SECTION o N Shown Direct to Mason 7 Shown Direct to Masonry oo � 7 Outswing only w/6-9/16"jamb Outswing only w/b-9/16'jamb �o �,o LL Notes: 5 �Le Cn 1.Sidelite assembly screws located 6"from each end plus 6 more =w v equally spaced between (8 screws total per side jamb). 0 2.Sidelite assembly screws located 3"from each end&at centerline (3 screws along head jamb). o =o y a a o C CL o z zV � m o z � �s O d N W N (!1 O O � D INTERIOR a a Z `�° d ¢ -J W 0En Ca N N 40 41 42 SO o w o oaDE a M p N CQ < z 00 N N z 2 cc to a C p 0O t` En G N o` 4 Z EXTERIOR z 1-1/4"MIN. SEE NOTE 1DATE., 8 02 16 z EMB.(TYP.) 1-1/4"MIN. sue. o 2 VERTICAL CROSS SECTION EMB.(TYP.) DWG. BY: N JK m' 1 HORIZONTAL CROSS SECTION 7 Shown Direct to Masonry 7 Shown Direct to Masonry Outswing only w/6-9/16'jamb CHK. BY: LFS 3 Outswing only w/6-9/16'jamb DRAWING NO.: FL-20468.5 0 SHEET 7 OF 14 u Notes: ./�V49 1.Sill Item#'s 17, 18,32,34,35,36,37,38&39 are attached to jambs w/(3) #8 X 2-1/2"pfh screws at each end. Q;• ; ' t''� Sill Item#'s 16&33 are attached to jambs w/(2) #8 X 2-1/2"pfh screws at each end. CD ,t;. Sill Item#15 is attached to jambs utilizing (2) #10 X 2"pph SMS at each end. ' �: ` � •,� M 2.Sidelite assembly screws located 3 from each end&at centerline(3 screws along sill). N', d • °��•,,z ..'� Z p Z ,. •'i �• • GJ C rn 0; 00 INTERIOR EXTERIOR INTERIOR — EXTERIOR '��!<< •• • • ©` N > M i Co Z 0 °° z0 AA EXTERIOR INTERIOR o - � Z o Z v 40 41 42 40 41 42 9 '°' m 3 8 7 16 17 18 U) ° c 0. 0. 40 41 42 m a a Co Co 38 39 32 33 34 35 36 37 E oZ N SEE NOTE 1 SEE NOTE 1 Q Jaw SEE NOTE 1 E E E vL=L Cn �,- R' VO o p o' °c p u ° °° p .. o �0 N(_ o °, ° p c ° v o ° ° u � 00 m En CC C Z D � ~_m 'Q : O 3 D Z 1 VERTICAL CROSS SECTION ` m 2 VERTICAL CROSS SECTION 3 VERTICAL CROSS SECTION W 0 ii W $ Inswing Sill W $ Inswing Sill $ Outswing Sill � > > m INTERIOR EXTERIOR m N ZV ZC; a K EXTERIOR INTERIOR SEE NOTE 2 25 50 EXTERIOR INTERIOR O N N w cn o zo Z 3: 32 41 42 77 75 32 33 34 35 36 37 38 39 SEE NOTE 2 25 5fl 16 17 18 Q o o ..., w 0 En N 10 aoWo o' 15 76 00 � � E Q D. E E �uoza SEE NOTE 2 ^ a = N 00 o T ^ w z ^ ~ F rl- Ul Z op d o p M N LU DATE 08102116 Z Z Z � sc&E: N.T.S. Uj p DWG. BY.- JK M �+°OCL CHK. BY: LFS 3 w �I W DRAWING NO.: VERTICAL CROSS SECTION m 5 VERTICAL CROSS SECTION 6 VERTICAL CROSS SECTION $ Public Access Sill W $ Inswing Sill $ Outswing Sill FL-20468.5 N SHEET 8 OF 14 CU Iw vl� Q: 'o rn �j:•� -' rn -z co OD f�J zz � °' z m U N •• ol O 0 o II Z x Z tJ MULLION MULLION 4„ TYP. EL c o 0 0° c w 4"(TYP.) 4"(IYP.) 4"(TYP.) ( } a � m a - cl E o , . d . 8 (TYP.) . d o 'z ° d7 P d o Cw 00 Jd I I I I i l CL N II II II { I HEAD&JAMBS I I HEAD&JAMBS 0 11 I I I I I� Y (TYP.) I I (TYP.) z I { I I �"' m II II w iI iI I1I1 II II D rvC> w U N a =m2X BUCK an (TYP.) o ro ii Il ii o a II it Y�- v E II II II 1 1 _ 0 + + ZOU I I Xp: I { II Q � OLjF= �i Id If Q � II I I ::E z Q it ir� (j I { I 06 ZOOZ ^ II N I I O I I I I F N J N II n uV ll II II O Z z II Il 11 W W 0 it II o { I z F- d r.. t!S II II II Q OtWn � � � `a <a I I I I 00 L N � � II II OL�i 71 ¢ W4W -, II II II Opp LL ci CL [IZA— w z o p p 0 U ED MASONRY xo�ox OX° O(TYP.) rj DATE: 08/02/16 SCALE: N.T.S. 0 W Q DWG. BY: JK m W 2X BUCK ANCHORING cHK. BY: LFS 3 DRA1YtNG NO.' m FL-20468.5 cu 0 SHEET 9 OF 14 IN i2 v e 4.5 i to aj ou JAMB TO HEAD DETAIL w z O m o DIRECT TO DIRECT TO (TYP.) ° 0� 0.a . z o o c� z ti MASONRY MULLION MASONRY E 0 z 00 HEAD 4' TYP. HEAD —7 TYP. ° U)It M 5 q .°c m (TYP.) (TYP.) T'(TYP.) (TYP.) MULLION ( ) .s � m a a a d: 8"(TYP.) 3"(TYP.) 4"(TYP.) 3"(TYP.) c z c . E 0 n e < W a a o Z CL -7/ �o oCLco � � o _ U N L 2X BUCK `O BUCK L 2X BUCK — "D �� m Q 1 X BUCK (TYP.) j 1 X BUCK �m c Q 01 HEAD&JAMBS .— — HEAD&JAMBS — — — ,- (TYP.) DIRECT TO (TYP.) � MASONRY N DIRECT TO a a MASONRY N � � u JAMBS — JAMBS T m (TYP.) (TYP.) L oU L ,_ — THRU MULLION — — Z " m 2 p O h THRU MULLION (TYP.) �v , N (TYP) Q n: FRAME Q °- z z m (TYP.) z "' W O � — — — — Ln Lq — SILL v � SILL ^ O '`�'' w N (TYP.) (TYP.) o o U IC-) a: J Q y av ev � W W O D 0: Q 0. a 0 1 1 I I 1 1 I 1 1 1 l i 11 1 1 N m ui F. � ° v` • v` O � ^ Q FJa' a Q O O h N xo/ox oxo - N z U W DATE 08/02/16 z SCAS: N.T.S. DWG. BY: X m 2 FRAME ANCHORING CHK. BY: LFS DRAWING NO.: FL-20468.5 0 SHEEP 10 of 14 N U K `�t►►►�>Ilull/ � $Xt °; '�' M � � p N' 7d JO ¢ z m SEE HINGE N O N O �i, ✓��� a 0 r DETAIL(TYP.) t o cn ao O M z ma, r U N .. • v U o p O xz a 0 o E a, z m ci (, 26 m of cc a. 5 Q r q -- --p W m a. a. LO 0- CL co __ -!'z 0 �� p SEE TONGUE v ;n ;� O O a = O STRIKE DETAIL z v° CD N ❑ +i CN m pLei p (TYP.) o 3,a J 25 +� " J 27 z _ 00 LU j � CV LATCH&DEADBOLT DETAIL a- a- ce o otl�C. KWkset 31 OOO q Uin Ln� Nm pNp �cn W � , m TONGUE STRIKE DETAIL Ezw � 3 SEE LATCH&DEADBOLT Mu tipoin Lock °�° a z DETAIL p = o 8 L Ne 0 0 -m O SEE LATCH w a Q Security Sub ;n Q Op o Op 8 DEADBIL OLT a a Strike Plate N I= `V > > m t 1 ro 28 o o $ z � gm oC; z � 0 22 L a CV W "' U? p O '- z Z m STRIKE JAMB HINGE JAMB STRIKE JAMB $Q z ,n ¢ w o n N 2� ❑ 27 Latch and Deadbolt Multipoint Lock o � cc ca U- O � W � 2X BUCK $ o 29 CL G 1 X BUCK LATCH&DEpADBOLLT DETAILMultioint Lock p p p a LATCH&DEADBOLT DETAIL Q Schlage M DIRECT TO ro F a MASONRY Q o J O O ^ U3 u LATCH & DEADBOLT STR►KE DETAILS 24 23 MULTIPOINT LOCK STRIKE DETAILS N z z DAB= 08/02/16 z Ste: N.T.S. ° a DWG. BY: JK m HINGE DETAIL CHK. BY: LFS 3 DRAWING NO.: FL-20468.5 0 m SHEET 11 OF 14 N v EXTERIOR o 11�% ,a A `� 0) to CELLULAR 1/2"GLASS BITE N�, 6 * � � M GLAZING TAPE _ 1"THK.GLASS %�'�'•. �y� o 1/8"TEMPERED GLASS o m 00 1/2"AIR SPACE11CO o M ao z° 5/32"ANNEALED GLASS N3 OmPo rn o N :2 ZQ (DZ O ®UEn maDOW 995 0.090"PVB INTERLAYER o OR (SAFLEX OR KURARAY BUTACITE) WROUGHT IRON INSERT °; m n ii °�° SIKA 552 INTERNAL GRID(GBG) 0 1/8"ANNEALED GLASS v Z N O j W #10 X 1-1/2"PPH SMS o° 'n: W INTERIOR 3A SWIGGLE GLAZING SPACER w cc v C GLAZING DETAIL o co G1 Aluminum Impact Lite Frame �7 Door Panels&Sidelites m N w� w z 20.88"D.L.O. DECORATIVE INSERT COEn WIDTH PRIVACY INSERT o � � D o o 1" LAMINATED INSULATED IMPACT GLASS INSERT OPTIONS a � > > m U Id iL � — U Q � � E2 Ln �7- Z �' 1.53" V z ° Z o � F = o ~ 1 0 (ff" N W N (/) Uj 3 O 00 O Z c V) Vim- J a J LtJ - W N F _ Cr (Ll t/) O LY W ►— WW CU O Q ^ #10 X 1-1/2"PPH SMS ° ¢ E z t (TYP.) ao ^ m g PO � z ALUMINUM FRAME3Q Aluminum Impact We Frame U N Door Panels&Sidelites ^ z o° 4 KS N DATE: 8102116 z 13 < 4" s=E: N.T.S. W (TYP.) -- DWG. BY. JK m ch CHK. BY: LFS 3 a DRAWING NO.: v ALUMINUM LITE FRAME FL-20468.5 SHEET 12 OF 14 v v d %`0111111111// /& V49 C7 ` - o�,• � ; toco tfill, o ` z 0 ao 0 �2.36" -I C �+ v N z INSWING THRESHOLD 37 INSWING THRESHOLD 32 Inswing Basic Fixed 7-1/2"Sill WOOD JAMB o ° z o z° Inswing Basic Composite Adjustable Sill 7-1/7' a U o m w 3 a u)v) q c 5 .Om " 5.83 C w 4.56 4.56" _ E `0 0 z N 3 LO ct NSWING THRESHOLD OUTSWING THRESHOLD o 0o z INSWING THRESHOLD _ _ _ _ 33 Inswing Basic Fixed Sill *Ilns\,ving Composite Adjustable Sill 6 Composite Sill z v ¢V) N !S m CL r7j 5.76' W o 5.77' = 4.56" ��m -Ti! 0 o - = O Ln r V 7 O ►— Y Y? 0 CL INSWING THRESHOLD m Inswing Moderate Climate Sill 1-3/8" 39 INSWING THRESHOLD w z V CL Inswing Basic Composite Adjustable Sill OUTSWING THRESHOLD o o17 m (i�YComposite/Aluminum Sill Z ci E_ L _ zCS0 5.75" 6.0 ZN 5.75" CL `� co Ir qo to o EO � Q � w >>— a rn `O Lei Ncc U- U 0 Q 45)INSWING THRESHOLD $ OUTSWING THRESHOLD 0 n o a Inswing Moderate Climate Sill PUBLIC ACCESS THRESHOLD Composite/Aluminum Sill Cr ¢ Q z 5 — (Thermal Break) o ^ Q H 5.75" o o 2.18" �214' t � � . 2.13" ,,._p o LO o � � � N Z U o DATE: 08102 16 ? u? `' a MALEN.T.S. 00 so c' DWG. BY: JK m INSWING THRESHOLD --1.79"—�I f�-1.9z, _ ..—2.061 0 0 CHK. BY: LFS 3 36 Inswing Basic Fixed 5 3/4"Sill to a i;o 9 "It o DRAWING NO.: v � SWEEP SWEEP SWEEP ca SIDELITE SPACER � SIDEltTE SPACER �W7 PACER � 75 Inswing o 7 Outswing FL-Z0468.5 0 Moderate Climate Thresholds 13 of 14 N � — — OO U `�� BILL OF MATERIALS BILL OF MATERIALS ITEM# DESCRIPTION MATERIAL REM# DESCRIPTION MATERIAL =a o 1 p J- u°'i M A 1 X BUCK (SG >= 0.42) WOOD 25 #$x 2-1/2" PFH WOOD SCREW STEEL N', j z0 O B 2X BUCK (SG >= 0.42) WOOD 26 #8 x 5/8" PFH WOOD SCREW STEEL �v►;,- y``� C 1/4„MAX.SHIM SPACE - 27 LATCH STRIKE PLATE STEEL �, // '�ki�� F o �F) D 1/4 X 2-3/4 PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE STEEL �,, ��� _ > QR M M E MASONRY-3,000 PSI MIN. CONCRETE CONFORMING TO ACI CONCRETE 28A DEADBOLT SUB STRIKE PLATE STEEL ilt00 z o co 0 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 29 4'X 4' HINGE STEEL o ` � v N o Q F #10 X 2" PFH WOOD SCREW STEEL 30 LATCH & DEADBOLT STRIKE PLATE (TONGUE SYSTEM) ALUM/COMP " ® E o) o m W G 3/16 X 3-1/4 ITW CONCRETE SCREW STEEL 31 MULTIPOINT STRIKE PLATE (TONGUE SYSTEM) ALUM/COMP a Cn M 5 q = m I 1/4"X 1-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 32 INSWING THRESHOLD ALUM/COMP o m o 0- `` J 1/4"X 3-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP ; �Z N L #10 X 2-1/2" PFH WOOD SCREW (1.15"MIN. EMBEDMENT) STEEL 34 INSWING THRESHOLD ALUM/COMP o �a M 3/16"X 2-1/4' ITW CONCRETE SCREW STEEL 35 INSWING THRESHOLD ALUM/COMP N 3/16"X 2-3/4' ITW CONCRETE SCREW STEEL 36 INSWING THRESHOLD ALUM/COMP 1 JAMB (FINGER JOINT PINE ) WOOD 37 INSWING THRESHOLD ALUM/COMP 6 WEATHERSTRIP (MEDIUM REACH) FOAM 38 INSWING THRESHOLD ALUM/COMP o Q co 7 WEATHERSTRIP (LONG REACH) FOAM 39 INSWING THRESHOLD ALUM/COMP q� Q N g 8 SWEEP VINYL 40 DOOR PANEL (BOOK) - m 9 SWEEP (USE w/ MODERATE CLIMATE THRESHOLD) VINYL 41 DOOR PANEL (HYBRID) - tiW in CA 10 SWEEP (USE w/ PUBLIC ACCESS THRESHOLD) VINYL 42 DOOR PANEL (U1) - 15 PUBLIC ACCESS THRESHOLD ALUM 50 SIDELITE (FULL LITE) - o O 16 OUTSWING THRESHOLD ALUM/COMP 75 SIDELITE SPACER (INSWING) PVC X 17 OUTSWING THRESHOLD ALUM/COMP 76 SIDELITE SPACER (OUTSWING) PVC E- Y Y >- 18 OUTSWING THRESHOLD ALUM/COMP 77 SIDELITE SPACER (INSWING) -MODERATE CLIMATE SILL PVC � ' 00 Q 22 #8 x 3/4" PFH WOOD SCREW STEEL 88 1 X MULLION (SG>= 0.55) WOOD w o 23 #10 x 3/4' PFH WOOD SCREW STEEL r m 24 #10 x 1" PFH WOOD SCREW STEEL oC5a — �r o D NW N U3 Z Z CONCRETE ANCHOR NOTES: z "' a w _o 1. Concrete anchor locations at the corners may be adjusted to maintain the min. a o N - CD edge distance to mortar joints. o w o 2. Concrete anchor locations noted as'MAX. ON CENTER"must be adjusted to °o i w w omaintain the min. edge distance to mortar joints,additional concrete anchors a may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. o z a CrgQ � z < 3. Concrete anchor table: o N ^ N ANCHOR ANCN..O MIN. . . MIN.CLEARANCE MIN. CLEARANCE ^ UJ z TO MASONRY TO ADJACENT mo r .- TYPE " SIZE EMBEDMENT Q o EDGE:: .:ANCHOR o o � � m z a TAPCON0 1/4" 1-1/4" 2" 4"ITW "' N " z 0 ELCO OATE- 08/02/16 z ® 1/4" 1-1/4" 1" 4" ULTRACON scALE: N.T.S. ' ITW ® 3/16" 1-1/4" AS SHOWN 1-1/2" M. BY: JK m TAPCON CHK. BY: LFS 3 WOOD SCREW INSTALLATION NOTES: DRAWING NO.: CU 1.Maintain a minimum 518"edge distance, 1"end distance, & I"o.c.spacing of FL-20468.5 wood screws to prevent the splitting of wood. 0 sHEEr 14 of 14 0 v