Loading...
HomeMy WebLinkAboutPiling Design Analysisz Cool and Cobb Engineering Company Date: 1 15 20 Job: Carol Bailey Location: 6514 Student Way Ft. Pierce, FL 34951 PILING DESIGN ANALYSIS JAN 2-2 1028 Permitting Departmen� St. Lucie Co. -ef•- The load requirements for the pilings designed to assist in supporting the identified areas of the subject residence were determined. The selected piling locations and the specific piling are identified on the Pier Identification and Location Plan attached. The calculated total loads on the piles in the specific location, including both dead and live loads are documented in the attached table which is designated as Attachment "A". Based on the total load requirements for each of thesepiles, the push pier driver is to be employed. The push pier driver should be employed with a calculated load of 12,000 lbs., which will provide pile capacity, including the 2 to 1 safety factor of 24,000 lbs. which is greater than the maximum calculated total load of 12,000 lbs. which occurs on the pile identified as no. A-1 . Based on this analysis, the use of the push pier driver for the helical piles with a specific load of 24,000 lbs. and a minimum depth of 15' is approved and certified as meeting all the requirements of the Florida Building Code 2017 61h Edition, and good engineering practice. This is not to be the primary support structure, but a supplement support to assist in support of the weight of the structure, which will reduce the total pressure on the existing soils. After completion of installation, Cool and Cobb Engineering Company shall be supplied with a drilling log of the location and depths of each pile installed so they can evaluate the installation and prepare the "As Built" drawings. General Notes: 1. All piles to be installed in accordance with ICC ES AC 358 2. A log of each pile to be kept by Contractor noting depth for each pile. 3. Piles installed less than 48" apart are to be battered 10° away from each other. 4. This design is based on the loads of the structure placed on the shallow soils under the structure. 5. No deep soils geotechnical testing information was provided for this design. 6. This design does not address any possible sink hole activity as defined in Florida Statute § 627.706. 1 15 20 Carl Cool, P.E. _ State of Florida " Professional Engineer"No. 16921 zl�4/ 203 W. Main St. Avon Park, FL 33825 CA No. 29713 File C"Py Office: (863) 657-2323 Fax: (863) 657-2324 ** MAX SPACIN( MIN SPACING A-7 A-6 A-5 A-J A-3 LFGEND: o A-1 -A-11 HELICAL PILES NOTES. ONE STORY RESIDENTIAL File COPY _ CMU W/ STUCCO Date: 1/15/2020 Sheet 2 of 4 Seal: - Project: Carl Cool, P.E. Coal & Cohh Engineering Company FLA LICENSE NO 16921 Carol Bailey 203 West Main St. Certificate of Authorization #29713 6514 Student Way Avon Park, FL 33825 (863) 657-2323 Office Ft. Pierce, FL 34951 (863)657-2324 Fax carl@coolandcobb.com 1/15/2020 Cool and Cobb Engineering Company Date: 1/15/2020 Job: Carol Bailey Location: 6514 Student Way Ft. pierce, FL 34951 Attachment "A" Total Load on Pile (Live Load + Dead Load) PILE NO. TOTAL CALCULATE LOAD A_I 12,000 Ibs __. A 2 12,000 Ibs A 3 12,000 Ibs _ A-q — 12,000 Ibs A-5 12,000 Ibs _..._.�—_..�.. A 6 12,000 Ibs A 7 12,000 lbs — A 8 12,000 Ibs A-9 12,000 Ibs 12,000 Ibs Maximum Total Load on Pile: 12,000 Ibs &If!%JG1/'� Cool and Cobb Engineering Co. 1/15/2020 203 W. Main St. Carl E. Cool, P.E. - Avon Park, FL 33825 PE# 16921 CA# 29713 Ale cwy i -Push Pier System Lift Brackets TMG Manufacturing offers 4 different foundation brackets designed to meet the needs of any foundation support application. Choose between our heavy duty lift bracket or our medium duty lift bracket. Both brackets are also available for grout injection. All of our brackets are made from high -tensile strength steel and comprised of CNC machined parts, ensuring precision and accuracy. In addition, all brackets are robotically welded guaranteeing a quality product every time. All brackets have been field and lab tested and can be powder -coated or galvanized. Push Pipe TMG Manufacturing offers several types of foundation support piers, designed to be installed directly to load bearing strata. All piers are used in conjunction with our lift brackets to stabilize and strengthen existing foundations. All pins are engineer certified and field and lab -tested. Can be galvanized or powder -coated. • .. e - '4 .3 i '. 'b .f. i 5$ p }j R. y.rp 'SFd t 6} d t .5 . $'a ` GryC✓y 14 ' 4 ^ 87 t50(1 00 5#and8rti Ft�sfi1 f?Ip8TRa<,' �`' 217,, A262 „ Puffh rr „�s,s0o"x 27s aon nt Duty Ply w 28�5 Standarn�ec#fOrajushPzp'fi �2 t µ 44,5ot `26201)0° x 2t}75 HeavyDutyYlnfeCtronPustt�Alpe � w ��08� tit `2s�5'���* f"a'{1u�69oo°t�° 1 1 v1Nn'iv>dS z-' rsd _ 31 1/15/2020 Carl E. Cool, P.E. PE# 16921 Foundation / Stem Wall Top Plate Bottom Plate racket Tube File Cop c Ulde Sleeve Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 CA# 29713 TMG Manufacturing • Tampa, Florida • Telephone: (813) 464-2299 • info@tmgmfg.com • w Amgmfg.com