HomeMy WebLinkAboutCreek Technical Services Evaluation ReportCREEK Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, C EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS
Issued September25, 2017
220 West Street
Joplin, MO 64801
(417) 624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Y
��
Frederick, MD
FILE
I
Dallas, TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: - Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1,1507.2.5. 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Enli
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP-D43-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-051.02.01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-114-02.01
TA8100
1995
PRI Construction Materials Technologies (TST5878)
TAP-117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-165-02-01
TAS100
1995
PRI Construction Materials Technologies (TST5878)
TAP-280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-307-02.01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-315-02.01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP-317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03898
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
OSNK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
10CA5D498
ASTM D 3462
201 DA
UL LLC (TST9628)
1 OCA64882
ASTM D 3161
2016
UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110643
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787D43752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669) -
TSP15001.3
Calculations
2017
TEP15001.4
FL18355-R4
Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal®
(Frederick, Joplin &
Tuscaloosa)
Glass -Seal
(Frederick &
Tuscaloosa)
Glass -Seal
(Joplin)
?LHe g0---'
(D'a(las, Frederick,
Joplin, Phillipsburg &
Tuscaloosa)
`Heritage® Premium
(Dallas, Frederick,
Phillipsburg &
Tuscaloosa)
Heritage® Premium
(Frederick)
Heritage® Vintage®
(Phillipsburg)
Heritage® Woodgate
(Dallas & Frederick)
Heritage& Woodgate
(Frederick)
Hip and Ridge Shingles
(Frederick & Joplin)
Vintage® Hip and Ridge
(Phillipsburg)
TAMKO BUILDING PRODUdTS
Asphalt Shingles
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
ceramic granules complying with ASTM D 3462.
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 34ab
asphalt shingle with fiberglass mat coated an both sides with asphalt and surfaced with
ceramic granules complying with ASTM D 3462.
12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
mat coated on'both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
13-114" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
12" x 36-318", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
shingle surfaced with mineral granules complying with ASTM D 3462.
12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FI-1835S114 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G203. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
INSTALLATION
Elite GlassSeal®
Basic Wind Speed (V e):
(Frederick, Joplin &
Basic Wind Speed (V w)
Tuscaloosa)
Deck (HVHZ):
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ)
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-1/84nch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern' or "6 Nail Pattern" detailed below.
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattem (Ndn-HVHZ only)
NAILS
Bult Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nall Pattern
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
Heritage®
Basic Wind Speed (Vwt):
(Dallas, Frederick, Joplin,
Basic Wind Speed (V,,d)
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
Heritage® Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Deck (Non-HVHZ):
&
Heritage® Woodgate
(Dallas & Frederick)
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ)
6
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern' detailed
below.
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattem° or "6 Nail Pattern" detailed below.
NAILZONE
BOND
EXPOSURE 6-6/9'
12-1 /2" -+- 12-318" - - 12-1
Figure 3. Heritage% Heritage® Premium, and Heritage® Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
1"
FASTENERS
NAIL ZONE
COMMON
BOND
EXPOSURE 6_5W
I
L01 �11-10
Figure 4. Heritage® & Heritage® Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
1. ]-112'- -7.1/2 +4/8 7.1/21►�F7=i/1 �—V
Figure S. Heritage® Woodgate
6 Nall Pattern
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Common Bond
Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate
Alternate 6 Nall Pattern
7-1
Figure 7. Heritage® (Tuscaloosa)
Expanded Nall Zone
Nall patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-114 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Premium Basic Wind Speed (Vut):
(Frederick) Basic Wind Speed (Vasa):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 160 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 In. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and In accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 In. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either °4 Nail
Pattern" or "6 Nail Pattern" detailed below.
5e
Figure 6. Heritage® Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
Figure 9. Heritage® Premium (Frederick)
6 Nail Pattern
ZONFJ
WON BOND
-
TBP15001.4 FL18355-114 Page 6 of 11
This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty. installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
Heritage® Woodgate Basic Wind Speed (Vo):
(Frederick) Basic Wind Speed (V w):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (Non-HVHZ):
5-1}°
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 In. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern* or "6 Nail Pattern" detailed below.
EXPOSURE 5e
1'i—rl 11e +.12-Vg'-- - 11" —4 �-1"
Figure 10. Heritage® Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
S
!Kul
1"-� 1 _ 9.1/2" �►�3' 9�418 9N�M 9.11r -4 �4-
Figure 11. Heritage® Woodgate (Frederick)
6 Nail Pattern
7 of 11
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage® Basic Wind Speed (V�a):
(Phillipsburg) Basic Wind Speed (Vad):
Deck (HVHZ):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"5 Nail
Pattern' or T Nail Pattern" detailed below.
Figure 12. Herltage® Vintage®
5 Nail Pattern (non-HVHZ only)
Figure 13. Heritage® Vintage®
6 Nail Pattern
TBP16001.4 FL1 a355-114 Page 8 of 11
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
E CREEK
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (V x):
(Frederick & Joplin) Basic Wind Speed (Vew):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max.194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
exposure
Figure 1
�� to
Fastener
Figure 2
Figure 14. Hip & Ridge (Frederick & Joplin)
FL1
ufposure
9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer snail notlry UKttK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
Vintage® Hip & Ridge Basic Wind Speed (Vwo:
(Phillipsburg) Basic Wind Speed (Va.e):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment•
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max.150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements',
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
exposure
Figure t
n
so
{ VFstener
12"
u =Kposure
1/2"
Figure 2 r" Figure 3
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
FL18355-R4
10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 It in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to undedayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers
published application Instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6 h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
�����pPV rR�tNi
ENs'Fs%
2017.09.25
' No 740211.-11:31:41
-04 00
L9 STATE OF : Q?
0�0T' P,.' ��C
Zachary R. Priest, P.E.
Registration No. 740
E��`�,,
ONAIFlorida
Organization No. A E1166921
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the
product.
END OF REPORT
FL18355-R4
11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer snail nary UJILLK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.