Loading...
HomeMy WebLinkAboutBuilding permit application (2) r "'F4?vf 9 2160 SW Poma Drive Palm City, FL 34990 S772)872-8034 n� 4€ ', t7}R�..� u..M....±......._.... ��� fJ f A S ,n . ,.. Compliant with Florida Building Code 2017 (61' ed.) �RC EiVP-� Compliant with Florida Product Approval Rule#611320 3 Compliant: Keystone Certifications MAY 14 c.t 20 1 ST. Lucie county, Permitting Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min..15/32" plywood or Wood Deck w/ min.0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, &4 Attachment):#10 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min.thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. See Fastener attachment specifications above Install Details:.Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16"ox. 16"ox. 8"O.C. 6"ox. FASTENER SPACING (ALONG Panel width) 12"ox. 12"ox. -12"o.c. 12"ox. 'FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING,INC.TST ID#: 1527 UL 580-06& 1897-041 Test Report EM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY--UL 1897-04 is equivalent to test standard UL 1897-1�f I *Design pressure margin of safety 2;1 r, Locke Bowden,P.E.does not have,not will acquire a financial int�TTir;assgl4�m��Wfacturing or distributing products under this evaluation. . Locke Bowden,P.E.is not owned;operated,or control atly coatpat'0prribbtif atures,or distributing products under this report. 6 — 4 /'4 v m ,, CODE C®MPL.I C1Jr� fl. �a, r FILE C®pl( . �. ST. �UCIE CO NTY ��,s,�Ng�1 ra�����e�.��``.,• FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details Limitations:' 1. Underlayment to be compliance with current Florida Building Code(FBC)2017 6t'ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6t'ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report. Fasteners- #9 x 1-1/2"Min.or #10 x 1-1/2°Min.perTsWs'Al for Row 5-v Crimp Roof Panel Spacing and Design Pressums Hexwasher Head Wood Screws Q' ,lm .9 Dedc 15132'or greater Plywood,or -Wood plank 'l: Panel Profile Nominal 12" Nominal 12" O.C. O.C. Fasten _E9 x f-71/2"Min. or #10 x 1-1/2"Min.per Table"A" Hex Washer Head Screw Spaced 12"o.c.across the Panel Wdth Panel Refer to Table"A"for Spacing Along Panel Overlap Length Deck-15/32"or greater Plywood,or -Wood plank i i MIAMI-DADE � t MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 A ----- ���___�.._' T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCEO w. � . 1 E.I.DuPont De Nemours & Co.,Inc. 5401 Jefferson Davis Highway,Donnelly Building MAY Richmond VA.23234 ST. Lucie County, � ferrr)itting , SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: DuPoni-'TyvekQ ProTec 120,DuPont Tyvekg ProTec 160,DuPont Tyvek ProTec 200. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has-been no change in the applicable building code negatively affecting the performance of this product. TERAHNATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or ils is "butors and shall be available for inspection at the job site at the request of the Building Offi This NOA consists of pages 1 through 4. IF COMPI-� VY 111 The submitted documentation was reviewed by Freddy Semino ®®� e ® -f �S-1a ��GJ 801G MIAMI•DADE COUNTY 0.: 19-0109.07 F`� ration Date: 04/21/21 Approval Date: 03/14/19 Page 1 of 4 i i ROOFING COMPONENT APPROVAL Cateaory Roofing Sub-Cateeory: Underlayment Material: Polypropylene SCOPE: This approves DuPont"'Tyvek®ProTec 120,DuPont""TyveV ProTec M 160,DuPont""Tyvek®ProTec""200 as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: Test Product Product Dimensions Specification Description DuPont'"'Tyvek® 48"x 250'rolls ASTM D226 Type Woven synthetic polymer underlayment with two ProTecTM 120 26 lbs:per roll I&H sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. DuPontTyveV 48"x 250'rolls ASTM D226 Type Woven synthetic polymer underlayment with two ProTec'160 32 lbs.per roll I&II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. DuPont'TyveV 48"x 250'rolls ASTM D226 Type Woven synthetic polymer underlayment with two ProTec 200 35 lbs.per roll I&H sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. MANUFACTURING LOCATION: 1. Qindao,China EVIDENCE SUBMITTED:. Test Agency Test Identifier Test Name/Report Date Intertek Testing Services 101866009COQ-002A Physical Properties 11/19/14 101866009COQ-001 ASTM D 226 11/17/14 JL.MIAMbDADE COUNTY NOA No.: 19-0109.07 Expiration Date: 04/21/21 Approval Date: 03/14/19 Page 2 of 4 INSTALLATION SPECIFICATIONS: (Single Laver: Slopes of 2:12 or greater) DuPont"'Tyvek@ ProTec"'120,DuPont"Tyvek®ProTec"'160,DuPont'Tyvek®ProTec 200 Roof Underlayment 1. DuPont'"Tyvek®ProTec'" 120,DuPont"'Tyvek®ProTec'" 160,DuPont" Tyvek®ProTec"'200 Roof Underlayments shall be installed in strict compliance with applicable Building Code. 2. DuPont""Tyveko ProTec"' 120,DuPont""Tyveke ProTec' 160,DuPont'"Tyvek®ProTec'200 Roof Underlayments shall be installed with a minimum 4-inch horizontal lap and 6-inch vertical laps in a shingle layer fashion. Vertical laps in a succeeding course shall be staggered from those in preceding course by minimum 6-feet. 3. DuPont"'Tyvek®ProTec' 120,DuPont'"Tyveke ProTec'" 160,DuPont`"Tyveke ProTec'"200 Roof Underlayments shall be fastened,with approved roofing nails and tin-caps spaced 6"o.c.at all laps and three staggered rows fastened 12"o.c. in the field of the roll. 4. DuPont"Tyvek®ProTec' 120,DuPont'Tyvek®ProTec' 160,DuPont'"Tyvek®ProTec'200 Roof Underlayments may be used with Asphaltic shingles,Wood shakes and shingles,Non-structural metal roofing,and quarry slate. 5. For fire classification of specific roof assemblies using D.uPont7 Tyvek' ProTec' 120, DuPont'" Tyvek® ProTec' 160, DuPont'" Tyvek® ProTec' 200 Roof Underlayments refer to a current Approved Roofing Materials Directory for fire ratings of this product. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LmTATiONS: 1, Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3, DuPont'"Tyvek®ProTec'" 120,DuPont'"Tyvek®ProTec' 160,DuPont'"Tyvek®ProTec'200 Roof Underlayments shall be applied to a smooth,clean and dry surface with deck free of irregularities.All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. DuPont"'Tyveke ProTec"' 120,DuPont'"Tyvek®ProTec' 160,DuPont"'Tyvek®ProTec'200 Roof Underlayments shall not be hot mopped,refer to manufacturer's published literature for product compatibility. 5. DuPont'Tyvek®ProTec' 120,DuPont'"TyvekO ProTec' 160,DuPont'"Tyvek®ProTec'200-Roof Underlayments shall not be applied over an existing roof membrane as a recover system. 6, DuPont'"Tyveke ProTec'" 120,DuPont''Tyvek®ProTec' 160,DuPont'Tyvek®ProTec:,200 Roof Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application. NOA No.: 19-0109.07 MIAMMADE COUNTY= Expiration Date: 04/21/21 NEW Approval Date: 03/14/19 Page 3 of 4 .�` .. ,. . r .. �. . 7. DuPont"Tyvek®ProTec" 120,DuPont"Tyvek®ProTec" 160,DuPont''Tyvek®ProTec"200 Roof Underlayments are components used in roof system assemblies.Roof system assemblies are approved under a specific Notice of Acceptance.Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. $, DuPont""Tyvek®ProTec" 120,DuPont?Tyvek®ProTec" 160,DuPont"Tyvek®ProTec'200 Roof Underlayments may be used with any approved roof covering Notice of Acceptance listing DuPont"'Tyvek® ProTec" 120,DuPont"Tyvek®ProTec" 160,DuPont'Tyvek®ProTec"200 Roof Underlayments as a component part of an assembly in the Notice of Acceptance. If DuPont?Tyvek®ProTec'' 120,DuPont' Tyvek®ProTec' 160,DuPont'Tyvek®ProTec"200 Roof Underlayments are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind' uplift resistance,and fire testing results. 9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. CMIAMIj-�DAMDECO=UNTY END OF THIS ACCEPTANCE NOA No.: 19-0109.07 MIAMI-DAD,COUNTY Expiration Date: 04/21/21 Approval Date: 03/14/19 Page 4 of 4