Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 1 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Load Short Form Mar 16, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hutchings Residnece, Groza Builders, IncFor: 4800 Seagrape Dr, Fort Pierce, FL 34982 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond 14ACXS030-230A** AHRI ref Coil CBA27UHE-030-230*++TDR AHRI ref 10259390 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW5.6 Sensible cooling Btuh20020 Heating output Btuh19194 Latent cooling Btuh8580 Temperature rise °F18 Total cooling Btuh28600 Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.052 Air flow factor cfm/Btuh0.048 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.78 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Laundry 50 414 931 22 45 M Bath 78 1547 683 80 33 WIC 69 1762 709 92 34 Master Suite 275 2571 2107 134 101 M Hall 25 0 0 0 0 Great Room 181 2281 4541 119 219 Foyer 50 592 318 31 15 Kitchen/DR 278 2730 5820 142 280 Linen 8 0 0 0 0 Bed 2 191 3052 2318 159 112 Bath 2 60 643 326 33 16 Hallway 26 0 0 0 0 Bed 3 155 2726 2049 142 99 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 2 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N House d 1444 18319 19802 953 953 Other equip loads 1416 752 Equip. @ 0.95 RSM 19609 Latent cooling 5924 TOTALS 1444 19735 25533 953 953 2020-Mar-17 07:05:15 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 1 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Building Analysis Mar 16, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hutchings Residnece, Groza Builders, IncFor: 4800 Seagrape Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 16.833232.6Walls 7.815339.0Glazing 0.4773.7Doors 7.214261.0Ceilings 21.642592.92.9Floors 14.929362.4Infiltration 24.14764Ducts 00Piping 00Humidification 7.21416Ventilation0Adjustments 100.019735Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 12.525742.0Walls 13.9286716.8Glazing 0.4783.7Doors 12.625971.8Ceilings 000Floors 3.97970.6Infiltration 26.15370Ducts 3.7752Ventilation 26.95520Internal gains 00Blower 0Adjustments 100.020554Total Latent Cooling Load = 5924 Btuh Overall U-value = 0.084 Btuh/ft²-°F Data entries checked. 2020-Mar-17 07:05:15 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 1 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Component Constructions Mar 16, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hutchings Residnece, Groza Builders, IncFor: 4800 Seagrape Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Block R-9 Wall: Blk Wall, Stucco Ext, 8" Thk, R-9 Foam Fill, 1/2" DW 4662.589.00.089181n 3912.16 5202.166202.589.00.089241e 4972.165932.589.00.089230s 8602.1610272.589.00.089399w 22682.1627072.589.00.0891051all Partitions Frm Wall, 1/2" DW Ext, R-11 Cav Ins, 1/2" DW Int Fnsh, 2"x4" Wood Frm, 16" OC STUD 3061.466172.9411.00.101210 Windows Impact, Low-e: Impact, Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (1.5 ft window ht, 1 ft sep.); 6.7 ft head ht 586.47657.2500.2509n Impact, TEMP: Impact, TEMP; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (2 ft window ht, 1 ft sep.); 6.7 ft head ht 467.59569.2800.3206n Impact, Low-e: Impact, Low-e; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.7 ft head ht 75620.83389.2800.32036e Impact, Low-e: Impact, Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.1 ft window ht, 1 ft sep.); 6.7 ft head ht 40123.01629.2800.32017e 40123.01629.2800.32017w 80223.03239.2800.32035all Impact, Low-e: Impact, Low-e; NFRC rated (SHGC=0.17); foreground = green grass (0.23); 21 ft overhang (6.5 ft window ht, 1 ft sep.); 6.7 ft head ht 17710.21518.7000.30017s Impact, Low-e: Impact, Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 8 ft overhang (3 ft window ht, 1 ft sep.); 6.7 ft head ht 1039.591009.2800.32011w 2020-Mar-17 07:05:15 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 2 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N Impact, Low-e: Impact, Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.7 ft head ht 39923.01619.2800.32017w Impact, Low-e: Impact, Low-e; NFRC rated (SHGC=0.17); foreground = green grass (0.23); 8 ft overhang (6.5 ft window ht, 1 ft sep.); 6.7 ft head ht 3488.913398.7000.30039w Doors Door, Mtl Fbrgl Type 783.73773.697.00.12721e Ceilings Attic, Shinglel Roof, R-30 Ceil Ins, 5/8" DW 1444 25971.8014260.9930.00.034 Floors On grade depth, Tile flr fnsh 00425928.700.989149 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 1 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Project Summary Mar 16, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hutchings Residnece, Groza Builders, IncFor:4800 Seagrape Dr, Fort Pierce, FL 34982 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh13555 Structure Btuh14432 Ducts Btuh4764 Ducts Btuh5370Central vent (44 cfm) 1416 Btuh Central vent (44 cfm) Btuh752 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh19735 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh19609 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2619 Ducts Btuh1588Central vent (44 cfm) Btuh1717 CoolingHeating Outside air14441444Area (ft²) Equipment latent load Btuh5924 1228312283Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh25533 Equiv. AVF (cfm) 4792 Req. total capacity at 0.70 SHR ton2.3 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond 14ACXS030-230A**AHRI ref Coil CBA27UHE-030-230*++TDR AHRI ref 10259390Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW5.6 Sensible cooling Btuh20020Heating output Btuh19194 Latent cooling Btuh8580 Temperature rise °F18 Total cooling Btuh28600Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.052 Air flow factor cfm/Btuh0.048Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15Right-Suite® Universal 2019 19.0.17 RSU27054 Page 1...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Right-J® Worksheet Mar 16, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Laundry 2 Exposed wall 148.5 ft 0 ft 3 Room height 8.5 dft 8.0 heat/coolft 4 Room dimensions ft5.5x9.0 5 Room area 1444.3 ft²49.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 2.162.16 196 181 466 391 0 0 0 0 .GG Impact, Low-eImpact, Low-e 0.2500.250 nn 7.257.25 6.476.47 9 0 65 58 0 0 0 0 .GG Impact, TEMPImpact, TEMP 0.3200.320 nn 9.289.28 7.597.59 6 0 56 46 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 2.162.16 316 241 620 520 0 0 0 0 11 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 20.7620.76 36 0 338 756 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 23.0223.02 17 0 162 401 0 0 0 0 DD Door, Mtl Fbrgl Type 0.127Door, Mtl Fbrgl Type 0.127 ee 3.693.69 3.733.73 21 21 77 78 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 2.162.16 248 230 593 497 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ss 8.708.70 10.1810.18 17 35 151 177 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 2.162.16 483 399 1027 860 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 9.599.59 11 22 100 103 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 17 0 162 401 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 17 0 161 399 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ww 8.708.70 8.918.91 39 68 339 348 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 210 210 617 306 72 72 212 105 CC Attic, Shinglel Roof 0.034Attic, Shinglel Roof 0.034 --0.990.99 1.801.80 1444 1444 1426 2597 50 50 49 89 FF On grade depth, Tile 0.989On grade depth, Tile 0.989 --28.6828.68 0.000.00 1444 149 4259 0 50 0 0 0 6 c) AED excursion 179 -47 Envelope loss/gain 10619 8116 260 147 12 a) Infiltration 2936 797 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 4600 500 Subtotal (lines 6 to 13)13555 14432 260 647 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 46 32 14 Subtotal 13555 14432 307 679 15 Duct loads 35%37%4764 5370 35%37%108 252 Total room load 18319 19802 414 931 Air required (cfm)Air required (cfm)953 953 22 45 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15Right-Suite® Universal 2019 19.0.17 RSU27054 Page 2...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Right-J® Worksheet Mar 16, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name M Bath WIC 2 Exposed wall 13.0 ft 17.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft13.0x6.0 ft11.5x6.0 5 Room area 78.0 ft²69.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 2.162.16 104 98 252 212 92 83 214 179 .GG Impact, Low-eImpact, Low-e 0.2500.250 nn 7.257.25 6.476.47 0 0 0 0 9 0 65 58 .GG Impact, TEMPImpact, TEMP 0.3200.320 nn 9.289.28 7.597.59 6 0 56 46 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 2.162.16 0 0 0 0 0 0 0 0 11 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 20.7620.76 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 DD Door, Mtl Fbrgl Type 0.127Door, Mtl Fbrgl Type 0.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 2.162.16 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ss 8.708.70 10.1810.18 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 2.162.16 0 0 0 0 48 48 124 104 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 9.599.59 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ww 8.708.70 8.918.91 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 48 48 141 70 0 0 0 0 CC Attic, Shinglel Roof 0.034Attic, Shinglel Roof 0.034 --0.990.99 1.801.80 78 78 77 140 69 69 68 124 FF On grade depth, Tile 0.989On grade depth, Tile 0.989 --28.6828.68 0.000.00 78 13 373 0 69 18 502 0 6 c) AED excursion -37 -38 Envelope loss/gain 899 431 973 427 12 a) Infiltration 246 67 331 90 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1145 498 1304 517 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1145 498 1304 517 15 Duct loads 35%37%402 185 35%37%458 192 Total room load 1547 683 1762 709 Air required (cfm)Air required (cfm)80 33 92 34 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15Right-Suite® Universal 2019 19.0.17 RSU27054 Page 3...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Right-J® Worksheet Mar 16, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Suite M Hall 2 Exposed wall 19.0 ft 0 ft 3 Room height 8.8 heat/coolft 8.0 heat/coolft 4 Room dimensions ft275.0x1.0 ft5.5x4.5 5 Room area 275.0 ft²24.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 2.162.16 0 0 0 0 0 0 0 0 .GG Impact, Low-eImpact, Low-e 0.2500.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0 .GG Impact, TEMPImpact, TEMP 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 2.162.16 0 0 0 0 0 0 0 0 11 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 20.7620.76 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 DD Door, Mtl Fbrgl Type 0.127Door, Mtl Fbrgl Type 0.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 2.162.16 40 22 57 48 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ss 8.708.70 10.1810.18 17 17 151 177 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 2.162.16 128 110 284 238 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 9.599.59 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 17 0 161 399 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ww 8.708.70 8.918.91 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 36 36 106 53 CC Attic, Shinglel Roof 0.034Attic, Shinglel Roof 0.034 --0.990.99 1.801.80 275 275 272 494 25 25 24 44 FF On grade depth, Tile 0.989On grade depth, Tile 0.989 --28.6828.68 0.000.00 275 19 545 0 25 0 0 0 6 c) AED excursion 46 -7 Envelope loss/gain 1470 1402 130 90 12 a) Infiltration 395 107 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1865 1509 130 90 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 38 26 -130 -90 14 Subtotal 1903 1536 0 0 15 Duct loads 35%37%669 571 35%37%0 0 Total room load 2571 2107 0 0 Air required (cfm)Air required (cfm)134 101 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15Right-Suite® Universal 2019 19.0.17 RSU27054 Page 4...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Right-J® Worksheet Mar 16, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Great Room Foyer 2 Exposed wall 14.5 ft 5.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft180.8x1.0 ft10.0x5.0 5 Room area 180.8 ft²50.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 2.162.16 0 0 0 0 0 0 0 0 .GG Impact, Low-eImpact, Low-e 0.2500.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0 .GG Impact, TEMPImpact, TEMP 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 2.162.16 131 94 242 203 45 24 62 52 11 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 20.7620.76 36 0 338 756 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 DD Door, Mtl Fbrgl Type 0.127Door, Mtl Fbrgl Type 0.127 ee 3.693.69 3.733.73 0 0 0 0 21 21 77 78 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 2.162.16 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ss 8.708.70 10.1810.18 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 2.162.16 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 9.599.59 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ww 8.708.70 8.918.91 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 54 54 159 79 0 0 0 0 CC Attic, Shinglel Roof 0.034Attic, Shinglel Roof 0.034 --0.990.99 1.801.80 181 181 178 325 50 50 49 90 FF On grade depth, Tile 0.989On grade depth, Tile 0.989 --28.6828.68 0.000.00 181 15 416 0 50 5 143 0 6 c) AED excursion -29 -17 Envelope loss/gain 1333 1334 332 203 12 a) Infiltration 308 84 106 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 1400 0 Subtotal (lines 6 to 13)1642 3277 438 232 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 46 32 0 0 14 Subtotal 1688 3309 438 232 15 Duct loads 35%37%593 1231 35%37%154 86 Total room load 2281 4541 592 318 Air required (cfm)Air required (cfm)119 219 31 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15Right-Suite® Universal 2019 19.0.17 RSU27054 Page 5...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Right-J® Worksheet Mar 16, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Kitchen/DR Linen 2 Exposed wall 19.5 ft 0 ft 3 Room height 9.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft278.3x1.0 ft2.5x3.0 5 Room area 278.3 ft²7.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 2.162.16 0 0 0 0 0 0 0 0 .GG Impact, Low-eImpact, Low-e 0.2500.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0 .GG Impact, TEMPImpact, TEMP 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 2.162.16 0 0 0 0 0 0 0 0 11 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 20.7620.76 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 DD Door, Mtl Fbrgl Type 0.127Door, Mtl Fbrgl Type 0.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 2.162.16 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ss 8.708.70 10.1810.18 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 2.162.16 176 126 324 271 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 9.599.59 11 11 100 103 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ww 8.708.70 8.918.91 39 34 339 348 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shinglel Roof 0.034Attic, Shinglel Roof 0.034 --0.990.99 1.801.80 278 278 275 500 8 8 7 13 FF On grade depth, Tile 0.989On grade depth, Tile 0.989 --28.6828.68 0.000.00 278 20 559 0 8 0 0 0 6 c) AED excursion 234 -1 Envelope loss/gain 1597 1456 7 13 12 a) Infiltration 415 113 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 2200 0 Subtotal (lines 6 to 13)2012 4228 7 13 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 8 14 -7 -13 14 Subtotal 2020 4242 0 0 15 Duct loads 35%37%710 1578 35%37%0 0 Total room load 2730 5820 0 0 Air required (cfm)Air required (cfm)142 280 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15Right-Suite® Universal 2019 19.0.17 RSU27054 Page 6...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Right-J® Worksheet Mar 16, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Bath 2 2 Exposed wall 28.5 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft190.5x1.0 ft10.0x6.0 5 Room area 190.5 ft²60.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 2.162.16 0 0 0 0 0 0 0 0 .GG Impact, Low-eImpact, Low-e 0.2500.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0 .GG Impact, TEMPImpact, TEMP 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 2.162.16 0 0 0 0 48 48 124 104 11 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 20.7620.76 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 DD Door, Mtl Fbrgl Type 0.127Door, Mtl Fbrgl Type 0.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 2.162.16 96 96 247 207 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ss 8.708.70 10.1810.18 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 2.162.16 132 115 295 247 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 9.599.59 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 17 0 162 401 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ww 8.708.70 8.918.91 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shinglel Roof 0.034Attic, Shinglel Roof 0.034 --0.990.99 1.801.80 191 191 188 342 60 60 59 108 FF On grade depth, Tile 0.989On grade depth, Tile 0.989 --28.6828.68 0.000.00 191 29 817 0 60 6 172 0 6 c) AED excursion 78 -17 Envelope loss/gain 1710 1276 355 195 12 a) Infiltration 539 146 113 31 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 0 Subtotal (lines 6 to 13)2249 1672 468 226 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 10 17 7 12 14 Subtotal 2259 1690 476 238 15 Duct loads 35%37%794 629 35%37%167 88 Total room load 3052 2318 643 326 Air required (cfm)Air required (cfm)159 112 33 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Mar-17 07:05:15Right-Suite® Universal 2019 19.0.17 RSU27054 Page 7...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Right-J® Worksheet Mar 16, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Hallway Bed 3 2 Exposed wall 0 ft 25.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft4.0x6.5 ft155.0x1.0 5 Room area 26.0 ft²155.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 2.162.16 0 0 0 0 0 0 0 0 .GG Impact, Low-eImpact, Low-e 0.2500.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0 .GG Impact, TEMPImpact, TEMP 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 2.162.16 0 0 0 0 92 75 192 161 11 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 20.7620.76 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 17 0 162 401 DD Door, Mtl Fbrgl Type 0.127Door, Mtl Fbrgl Type 0.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 2.162.16 0 0 0 0 112 112 289 242 GG Impact, Low-eImpact, Low-e 0.3000.300 ss 8.708.70 10.1810.18 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 2.162.16 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 9.599.59 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3200.320 ww 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 GG Impact, Low-eImpact, Low-e 0.3000.300 ww 8.708.70 8.918.91 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shinglel Roof 0.034Attic, Shinglel Roof 0.034 --0.990.99 1.801.80 26 26 26 47 155 155 153 279 FF On grade depth, Tile 0.989On grade depth, Tile 0.989 --28.6828.68 0.000.00 26 0 0 0 155 26 731 0 6 c) AED excursion -3 17 Envelope loss/gain 26 44 1527 1099 12 a) Infiltration 0 0 482 131 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 250 Subtotal (lines 6 to 13)26 44 2009 1480 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -26 -44 8 13 14 Subtotal 0 0 2017 1493 15 Duct loads 35%37%0 0 35%37%709 556 Total room load 0 0 2726 2049 Air required (cfm)Air required (cfm)0 0 142 99 2020-Mar-17 07:05:16 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 1 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Duct System Summary Mar 16, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hutchings Residnece, Groza Builders, IncFor: 4800 Seagrape Dr, Fort Pierce, FL 34982 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.387 / 0.313 in H2O in H2O0.387 / 0.313 Lowest friction rate in/100ft0.102in/100ft0.102 Actual air flow cfm953cfm953 Total effective length (TEL) ft684 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3325.047.9VlFx0x04.00.1041940643hBath 2 st3325.052.4VlFx0x09.00.1031341913052hBed 2 st3325.050.4VlFx0x08.00.1031181702726hBed 3 st3325.047.3VlFx0x04.00.1041837592hFoyer st1225.034.5VlFx0x07.00.149131712270cGreat Room st1225.039.4VlFx0x07.00.146131712270cGreat Room-A st1225.043.8VlFx0x07.00.144112571940cKitchen/DR st3325.053.6VlFx0x07.00.102112571940cKitchen/DR-C st3325.045.9VlFx0x07.00.104112571940cKitchen/DR-D st2210.022.1VlFx0x04.00.1675426931cLaundry st2205.017.7VlFx0x06.00.17439971547hM Bath st2210.019.9VlFx0x06.00.16861801286hMaster Suite st4310.029.1VlFx0x06.00.11461801286hMaster Suite-A st4310.027.3VlFx0x07.00.115411101762hWIC Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 551 514 0.102 516 14.0 0x0 VinlFlx st1 st1 Peak AVF 751 888 0.102 636 16.0 0x0 VinlFlx st4 Peak AVF 190 102 0.114 431 9.0 0x0 VinlFlx st2 st2 Peak AVF 393 256 0.114 500 12.0 0x0 VinlFlx 2020-Mar-17 07:05:16 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 2 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb4 0x 1910 134 305.8 0.102 431 9.0 x0 0 VlFx rt2 rb3 0x 1700 118 298.2 0.105 385 9.0 x0 0 VlFx rt2 rb1 0x 2700 163 148.2 0.211 496 10.0 x0 0 VlFx rt1 rb2 0x 5120 729 42.4 0.737 522 16.0 x0 0 VlFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 361 252 0.102 459 12.0 0x0 VinlFlx rt1 rt1 Peak AVF 631 415 0.102 590 14.0 0x0 VinlFlx 2020-Mar-17 07:05:16 Right-Suite® Universal 2019 19.0.17 RSU27054 Page 1 ...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N 694Job:Manual S Compliance Report Mar 16, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hutchings Residnece, Groza Builders, IncFor: 4800 Seagrape Dr, Fort Pierce, FL 34982 Cooling Equipment Design Conditions °F76.8Entering coil DB:Btuh20554Sensible gain:°F90.4Outdoor design DB: °F64.0Entering coil WB:Btuh5924Latent gain:°F77.4Outdoor design WB: Btuh26479Total gain:°F75.0Indoor design DB: cfm953Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: 14ACXS030-230A**+CBA27UHE-030-230*++TDRModel:LennoxManufacturer: cfm953Actual airflow: % of load97Btuh20020Sensible capacity: % of load145Btuh8580Latent capacity: %70SHR:% of load108Btuh28600Total capacity: Heating Equipment Design Conditions °F68.1Entering coil DB:Btuh19735Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm953Actual airflow: °F50Temp. rise:% of load97kW5.6Output capacity: Meets all requirements of ACCA Manual S. Job #: 694 Performed by Vicki Lynne Nisa for: Hutchings Residnece 4800 Seagrape Dr Fort Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 197 Page 1 Right-Suite® Universal 2019 19.0.17 RSU27054 2020-Mar-17 07:06:16 ... Dr -Hutchings Residence GBI.rup N Level 1 Garage Laundry M Bath WIC Master Suite M Hall Great Room Foyer Kitchen/DR Linen Bed 2 Bath 2 Hallway Bed 3 30 x 18 729 cfm 10 x 6 110 cfm 10 x 6 97 cfm 8 x 8 80 cfm 8 x 8 80 cfm14 x 14 270 cfm 6 x 6 40 cfm 12 x 12 170 cfm 12 x 8 191 cfm 12 x 12 191 cfm 10 x 10 112 cfm 10 x 10 112 cfm 10 x 10 131 cfm 10 x 10 131 cfm 8 x 4 37 cfm 10 x 10 112 cfm 6 x 6 54 cfm 12 x 8 170 cfm 16 " 14 " 10 " 12 " 9 " 9 " 6 "6 " 4 " 7 " 6 " 12 " 7 "16 " 7 " 7 " 9 " 7 " 14 " 4 " 7 " 4 " 9 " 8 "