RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential
Simulated Performance method shall include:
This Checklist
A FORM 405 report that documents that the Proposed Design complies with Section R405.3 of the Florida
Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail
status along with summary areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual completing the compliance
report (one page).
An input summary checklist that can be used for field verification (usually 4 pages/may be greater).
Energy Performance Level (EPL) Display Card (one page)
HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
Mandatory Requirements (five pages)
Required prior to CO for the Performance method:
Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1 - one page)
A completed Form 2017 Envelope Leakage Test Report (usually one page). Section R402.4 or R402.4.1.2
exceptions may apply.
If FORM R405 duct leakage type indicates anything other than "default leakage", then a completed FORM R405
Duct Leakage Test Report (usually one page).
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
FORM R405-2017
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-Energy® Florida 2017Right-Suite® Universal 2019 19.0.17 RSU27054 Page 2...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Groza Builders, IncBuilder Name:Hutchings ResidenceProject Name:
Permit Office:4800 Seagrape DrStreet:
Permit Number:Fort Pierce, FL 34982City, State, Zip:
St LucieJurisdiction:Hutchings ResidneceOwner:
St Lucie (Florida Climate Zone 2)County:FL, St Lucie Co IntlDesign Location:
1. New construction or existing New (From Plans)Area (ft²)Insulation (R)9. Wall types (1452 ft²)
2. Single family or multiple family Single-Family 210.0011.0Frm Wall, 1/2" DW Ext, R-11 Cava.
1242.209.0Blk Wall, Stucco Ext, 8" Thk, R-b.3. Number of units, if multiple family 1 N/Ac.
4. Number of bedrooms N/Ad.3
Area (ft²)Insulation (R)10. Ceiling types (1444 ft²)5. Is this a worst case?Yes 1444.2530.0Attic, Shinglel Roof, R-30 Ceila.
6. Conditioned floor area above grade (ft²)1444.25 N/Ab.
N/Ac.0Conditioned floor area below grade (ft²)
Area (ft²)R11. Ducts7. Windows (171 ft²)Description Area (ft²)407.746.0Sup: House Attic, Ret: House Attic, AH: (Unconditioned)a.
b.68.93Dbl Impact, 0.320a. U-Factor:
0.22SHGC:
EfficiencykBtu/hr12. Cooling systems9.00Dbl Impact, 0.250b. U-Factor:
SEER: 16.028.6Split air conditionera.0.21SHGC:
b.56.33Dbl Impact, 0.300c. U-Factor:
EfficiencykBtu/hr13. Heating systems0.17SHGC:AFUE: 100.019.2Electric stripa.36.40Dbl Impact, 0.320d. U-Factor:b.0.19SHGC:
14. Hot water systemsft5.072Area Weighted Average Overhang Depth:
Cap: 40 galElectric conventional (40 gal)a.0.197Area Weighted Average SHGC:
EF: 0.96
8. Floor types (1444.25 ft²)Insulation (R)Area (ft²)Conservation featuresb.
(None)1444.250.0On grade depth, Tile flr fnsha.
N/Ab.
None15. CreditsN/Ac.
44.80Total Proposed Modified Loads:Glass/Floor area:0.118 PASS46.25Total Baseline Loads:
Review of the plans and specificationsI hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed,
this building will be inspected forPREPARED BY:____________________________compliance with Section 553.908
Florida Statutes.DATE:____________________________________
I hereby certify that this building, as designed, is in
compliance with the Florida Energy Code.
BUILDING OFFICIAL:______________________OWNER/AGENT:___________________________
DATE:__________________________________DATE:____________________________________
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
03/16/2020
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
5/4/2020
FORM R405-2017
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 3...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
Building Input Summary Report
PROJECT
Street addressAddress type:3Bedrooms:Hutchings ResidenceTitle:Lot#:2Bathrooms:FLAsBuiltBuilding Type:Block/Subdivision:1444Conditioned Area:Hutchings ResidneceOwner:Platbook:1Total Stories:1# of Units:4800 Seagrape DrStreet:YesWorst Case:Groza Builders, IncBuilder Name:St LucieCounty:0Rotate Angle:Permit Office:Fort Pierce, FL 34982City, State, Zip:NoCross Ventilation:St LucieJurisdiction:NoWhole House Fan:Single-FamilyFamily Type:Ocean/LakeTerrain:New (From Plans)New/Existing:SuburbanShielding:Year Construct:Comment:
CLIMATE
Daily TempDesignHeatingInt Design TempDesign TempIECC
RangeMoistureDegree DaysSummerWinter2.5 %97.5 %ZoneTMY SiteDesign Location
Low57486757090412FL_Fort_PierceFL, St Lucie Co Intl
BLOCKS
VolumeAreaName#
f t³12283.00ft²1444.25House1
SPACES
HeatedCooledFinishedInfil IDBedroomsOccupantsKitchenVolumeArea#
YesYesYes100Noft³396.00ft²49.50Laundry1 YesYesYes100Noft³624.00ft²78.00M Bath2 YesYesYes100Noft³552.00ft²69.00WIC3 YesYesYes110Noft³2420.00ft²275.00Master Suite4 YesYesYes100Noft³198.00ft²24.75M Hall5 YesYesYes102Noft³1626.75ft²180.75Great Room6 YesYesYes100Noft³450.00ft²50.00Foyer7 YesYesYes102Yesft³2504.25ft²278.25Kitchen/DR8 YesYesYes100Noft³60.00ft²7.50Linen9 YesYesYes110Noft³1524.00ft²190.50Bed 210 YesYesYes100Noft³480.00ft²60.00Bath 211 YesYesYes100Noft³208.00ft²26.00Hallway12 YesYesYes110Noft³1240.00ft²155.00Bed 313
(Total Exposed Area = 1444 sq.ft.)FLOORS
CarpetWoodTileU-FactorAreaR-ValuePerimeterSpaceFloor Type#
001.00.989ft²49.500ft0LaundryOn grade depth, Tile flr fnsh1 001.00.989ft²78.000ft13M BathOn grade depth, Tile flr fnsh2 001.00.989ft²69.000ft18WICOn grade depth, Tile flr fnsh3 001.00.989ft²275.000ft19Master SuiteOn grade depth, Tile flr fnsh4 001.00.989ft²24.750ft0M HallOn grade depth, Tile flr fnsh5 001.00.989ft²180.750ft15Great RoomOn grade depth, Tile flr fnsh6 001.00.989ft²50.000ft5FoyerOn grade depth, Tile flr fnsh7 001.00.989ft²278.250ft20Kitchen/DROn grade depth, Tile flr fnsh8 001.00.989ft²7.500ft0LinenOn grade depth, Tile flr fnsh9 001.00.989ft²190.500ft29Bed 2On grade depth, Tile flr fnsh10 001.00.989ft²60.000ft6Bath 2On grade depth, Tile flr fnsh11 001.00.989ft²26.000ft0HallwayOn grade depth, Tile flr fnsh12 001.00.989ft²155.000ft26Bed 3On grade depth, Tile flr fnsh13
ROOF
PitchDeckEmittEmittSASolarRoofGableRoof
(deg)Insul.TestedTestedAbsor.ColorAreaAreaMaterialsType#
230No0.90No0.75Medium1565 f t²RoofAsphHip1 230No0.90No0.75Medium433 f t²RoofAsphHip2
ATTIC
IRCCRBSAreaVent Ratio (1 in)VentilationType#
NNft²1444.25300VentedFull attic1 NNft²399.75300VentedFull attic2
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 4...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
(Total Exposed Area = 1444 sq.ft.)CEILING
Truss TypeFraming FractionAreaU-FactorR-ValueSpaceCeiling Type#
Wood0.10ft²49.500.03430LaundryAttic, Shinglel Roof, R-30 Ceil Ins,1 Wood0.10ft²78.000.03430M BathAttic, Shinglel Roof, R-30 Ceil Ins,2 Wood0.10ft²69.000.03430WICAttic, Shinglel Roof, R-30 Ceil Ins,3 Wood0.10ft²275.000.03430Master SuiteAttic, Shinglel Roof, R-30 Ceil Ins,4 Wood0.10ft²24.750.03430M HallAttic, Shinglel Roof, R-30 Ceil Ins,5 Wood0.10ft²180.750.03430Great RoomAttic, Shinglel Roof, R-30 Ceil Ins,6 Wood0.10ft²50.000.03430FoyerAttic, Shinglel Roof, R-30 Ceil Ins,7 Wood0.10ft²278.250.03430Kitchen/DRAttic, Shinglel Roof, R-30 Ceil Ins,8 Wood0.10ft²7.500.03430LinenAttic, Shinglel Roof, R-30 Ceil Ins,9 Wood0.10ft²190.500.03430Bed 2Attic, Shinglel Roof, R-30 Ceil Ins,10 Wood0.10ft²60.000.03430Bath 2Attic, Shinglel Roof, R-30 Ceil Ins,11 Wood0.10ft²26.000.03430HallwayAttic, Shinglel Roof, R-30 Ceil Ins,12 Wood0.10ft²155.000.03430Bed 3Attic, Shinglel Roof, R-30 Ceil Ins,13
(Total Exposed Area = 1452 sq.ft.)WALLS
Below
Grade%
Solar
Absor.
Frm.U-Sheathing
R-Value
HeightWidthCavityAdjacent
To Frac.FactorAreaInFtInFtR-ValueSpaceWall TypeOrnt#
00.750.250.1010ft²72.0080911LaundryFrm Wall, 1/2" DWPartition-1 00.750.220.0890ft²104.0080139M BathBlk Wall, StuccoExteriorN2 00.750.250.1010ft²48.0080611M BathFrm Wall, 1/2" DWPartition-3 00.750.220.0890ft²92.0086119WICBlk Wall, StuccoExteriorN4 00.750.220.0890ft²48.008069WICBlk Wall, StuccoExteriorW5 00.750.220.0890ft²39.6108649Master SuiteBlk Wall, StuccoExteriorS6 00.750.220.0890ft²127.61086149Master SuiteBlk Wall, StuccoExteriorW7 00.750.250.1010ft²36.0086411M HallFrm Wall, 1/2" DWPartition-8 00.750.220.0890ft²130.5096149Great RoomBlk Wall, StuccoExteriorE9 00.750.250.1010ft²54.0090611Great RoomFrm Wall, 1/2" DWPartition-10 00.750.220.0890ft²45.009059FoyerBlk Wall, StuccoExteriorE11 00.750.220.0890ft²175.5096199Kitchen/DRBlk Wall, StuccoExteriorW12 00.750.220.0890ft²96.0080129Bed 2Blk Wall, StuccoExteriorS13 00.750.220.0890ft²132.0086169Bed 2Blk Wall, StuccoExteriorW14 00.750.220.0890ft²48.008069Bath 2Blk Wall, StuccoExteriorE15 00.750.220.0890ft²92.0086119Bed 3Blk Wall, StuccoExteriorE16 00.750.220.0890ft²112.0080149Bed 3Blk Wall, StuccoExteriorS17
(Total Exposed Area = 21 sq.ft.)DOORS
HeightWidth AreaInFtInFtU-ValueStormsSpaceDoor TypeOrnt#
f t²21.007030.127NoneFoyerDoor, Mtl Fbrgl TypeE1
(Total Exposed Area = 171 sq.ft.)WINDOWS
InteriorOverhangWall
ScreeningShadeSeparationDepthAreaImpactSHGCU-FactorNFRCPanesFrameIDOrnt#
outdoorBlinds 4 5°1 ft 0 in1 ft 0 inft²6.0Yes0.220.320YesDouble (Tinted)Vinyl2N1 outdoorBlinds 4 5°1 ft 0 in1 ft 0 inft²9.0Yes0.210.250YesLow-E DoubleVinyl4N2 NoneNone1 ft 0 in21 ft 0 inft²17.3Yes0.170.300YesLow-E DoubleVinyl6S3 outdoorBlinds 4 5°1 ft 0 in1 ft 0 inft²17.3Yes0.220.320YesLow-E DoubleVinyl7W4 outdoorBlinds 4 5°1 ft 0 in1 ft 0 inft²36.4Yes0.190.320YesLow-E DoubleVinyl9E5 outdoorBlinds 4 5°1 ft 0 in8 ft 0 inft²10.8Yes0.220.320YesLow-E DoubleVinyl12W6 NoneNone1 ft 0 in8 ft 0 inft²39.0Yes0.170.300YesLow-E DoubleVinyl12W7 outdoorBlinds 4 5°1 ft 0 in1 ft 0 inft²17.4Yes0.220.320YesLow-E DoubleVinyl14W8 outdoorBlinds 4 5°1 ft 0 in1 ft 0 inft²17.4Yes0.220.320YesLow-E DoubleVinyl16E9
GARAGE
Exposed Wall InsulationAvg. Wall HeightExposed Wall PerimeterCeiling AreaFloor Area#
01
INFILTRATION
ACH 50ACHEqLAELACFM 50SLAMethodScope#
7.000.53148.078.8214330.000379SimplifiedWholehouse1
HEATING SYSTEM
DuctsBlockCapacityEfficiencySubtypeSystem Type#
sys#1119.2 kBtu/hrAFUE: 100.0Electric strip1
COOLING SYSTEM
DuctsBlockSHRAir FlowCapacityEfficiencySubtypeSystem Type#
sys#110.70953 cfm28.6 kBtu/hrSEER: 16.0Split air conditioner1
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 5...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
HOT WATER SYSTEM
ConservationSetPntUseCapEFLocationSubtypeSystem Type#
None120 °F60 gal40 gal0.96Electric conventional1
DUCTS
HVAC #PercentCFM 25AirReturn------------------Supply ------------------
CoolHeatRLFQNLeakageOutHandlerLeakage TypeAreaLocationAreaR-ValueLocation#
116.00(Default)(Unconditioned)Default Leakage206 f t²House Attic408 f t²6.0House Attic1
TEMPERATURES
Ceiling Fans:YProgrammable Thermostat:
Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Cooling
Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Heating
Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Venting
HoursFlorida Building Code, 6th Edition
(2017)
Thermostat Schedule:
121110987654321Schedule Type
757575757575757575757575AMCooling (WD)
757575757575757575757575PM
757575757575757575757575AMCooling (WEH)
757575757575757575757575PM
727272727272727272727272AMHeating (WD)
727272727272727272727272PM
727272727272727272727272AMHeating (WEH)
727272727272727272727272PM
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
FORM R405-2017
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 6...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New home or addition 12. Ducts, location & insulation levelNew (From Plans)1. _______________
6.0R______________a. Supply ducts:
2. Single-family or multiple-family Single-Family2. _______________6.0R______________b. Return ducts:
(Unconditioned)______________c. AHU location:
3. Number of units, if multiple-family 13. _______________
28.6Capacity_______________13. Cooling systems
4. Number of bedrooms 16.00SEER______________a. Split system:34. _______________
SEER______________b. Single package:
5. Is this a worst case? (yes/no)Yes5. _______________SEER/COP______________c. Ground/water source:
EER______________d. Room unit/PTAC:
6. Con dition ed floor area (ft²)1444.256. _____________________________e. Other:
7. Windows, type and area*19.2Capacity____________14. Heating systems
HSPF______________a. Split system heat pump:Dbl Impact, 0.3207a. ______________a. U-Factor:
HSPF______________b. Single package heat pump:0.227b. ______________b. Solar Heat Gain Coefficient (SHGC):
100.00COP_______________c. Electric resistance:68.937c. ______________c. Area (ft²)
AFUE______________d. Gas furnace, natural gas:
8. Skylights AFUE______________e. Gas furnace, LPG:
______________f. Other:8a. ______________a. U-Factor:
8b. ______________b. Solar Heat Gain Coefficient (SHGC):
15. Water heating systems
9. Floor type, insulation level 0.960EF______________a. Electric resistance:
EF______________b. Gas fired, natrual gas:0.09a. ______________a. Slab-on-grade (R-value):
EF______________c. Gas fired, LPG:9b. ______________b. Wood, raised (R-value):
EF______________d. Solar system with tank:9c. ______________c. Concrete, raised (R-value)
EF______________e. Dedicated heat pump with tank:
10 Wall type and insulation:______________HeatRec%f. Heat recovery unit:
______________g. Other:a. Exterior:
10a1. ____________1. Wood frame (Insulation R-value):
16. HVAC credits claimed (Performance Method)910a2. ____________2. Masonry (Insulation R-value):
______________a. Ceiling fans:b. Adjacent:
______________b. Cross ventilation:1110b1. ____________1. Wood frame (Insulation R-value):
______________c. Whole house fan:10b2. ____________2. Masonry (Insulation R-value):
______________d. Multizone cooling credit:
11. Ceiling type and insulation level ______________e. Multizone heating credit:
Yes______________f. Programmable thermostat:30.011a. _____________a. Under attic (R-value):
11b. _____________b. Single assembly (R-value):
11c. _____________c. Knee walls/skylight walls (R-value)
11d. _____________d. Radiant barrier installed
*Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features
which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: _________________________Date: ______________________
Address of New Home: _____________________4800 Seagrape Dr Fort Pierce, FL 34982City/FL Zip: _________________
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
5/4/2020
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 7...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
PERMIT #:4800 Seagrape DrADDRESS:
Fort Pierce, FL 34982
MANDATORY REQUIREMENTS - See individual code sections for full details.
SECTION R401 GENERAL
The building official shall require that an energy performance level (EPL)R401.3 Energy Performance Level (EPL) display card (Mandatory).
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans
and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix RD.
The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements ofR402.4 Air leakage (Mandatory).
Sections R402.4.1 through R402.4.5.
Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted toException:comply with Section C402.5.
The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealingR402.4.1 Building thermal envelope.
methods between dissimilar materials shall allow for differential expansion and contraction.
The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordanceR402.4.1.1 Installation.
w ith the man uf ac turer’s ins tructions a nd th e criteria listed in Ta ble 4 02.4.1.1, a s ap plica ble to the metho d of cons truct ion. Where requ ired
by the code official, an approved third party shall inspect all components and verify compliance.
The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven airR402.4.1.2 Testing.
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existingException:buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. WhereR402.4.2 Fireplaces.
using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm perR402.4.3 Fenestration air leakage.
square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Site-built windows, skylights and doors.Exception:
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
FORM R405-2017
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 8...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
MANDATORY REQUIREMENTS - (Continued)
In Climate Zones 3 through 8, where open combustion air ducts provide combustion air toR402.4.4 Rooms containing fuel-burning appliances
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirementsof Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakageR402.4.5 Recessed lighting.
between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls
At least one thermostat shall be provided for each separate heating and cooling system.R403.1.1 Thermostat provision (Mandatory).
Heat pumps having supplementary electric-resistance heat shall have controlsR403.1.3 Heat pump supplementary heat (Mandatory).
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
All ducts, air handlers, filter boxes and building cavities that form the primary air containment passagewaysR403.3.2 Sealing (Mandatory).
for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7),
Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
A ir hand lers shall have a ma nuf a cture r’s d esign ation f or a n air leaka ge o f no more than 2 pe rcentR403.3.2.1 Sealed air handler.
of the design air flow rate when tested in accordance with ASHRAE 193.
Ducts shall be pressure tested to determine air leakage by one of the following methods:R403.3.3 Duct testing.
1. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
Building framing cavities shall not be used as ducts or plenums.R403.3.5 Building Cavities (Mandatory).
Me chan ical s yste m pip ing c apab le of carry ing f luids abov e 105 °F (4 1°C)R403.4 Mechanical system piping insulation (Mandatory).
or below 55°F (13 °C) s hall b e ins ulate d to a min imum of R-3.
Piping insulation exposed to weather shall be protected from damage, including thatR403.4.1 Protection of piping insulation.
caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
Heated water circulation systems shall be inR403.5.1 Heated water circulation and temperature maintenance systems (Mandatory).
accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
Heated water circulation systems shall be provided with a circulation pump. The system return pipeR403.5.1.1 Circulation systems.
shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systemsR403.5.1.2 Heat trace systems.
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
FORM R405-2017
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 9...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
MANDATORY REQUIREMENTS - (Continued)
Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heatR403.5.5 Heat traps (Mandatory).
traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as
possible to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1 Storage water heater temperature controls.
Service water heating systems shall be equipped with automatic temperature controls capableR403.5.6.1.1 Automatic controls.
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
se tting r ange sha ll be f rom 1 00°F to 1 40°F (38°C to 6 0°C).
A separate switch or a clearly marked circuit breaker shall be provided to permit the power suppliedR403.5.6.1.2 shut down.
to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
Water heating equipment installed in residential units shall meet the minimum efficiencies ofR403.5.6.2 Water heating equipment.
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment
installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the
appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1.
Solar systems for domestic hot water production are rated by the annual solar energyR403.5.6.2.1 Solar water heating system.
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
The building shall be provided with ventilation that meets the requirements of the FloridaR403.6 Mechanical ventilation (Mandatory).
Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including:
Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the
ventilation system is not operating.
When installed to function as a whole-house mechanicalR403.6.1 Whole-house mechanical ventilation system fan efficacy.
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered byException:an electronically commutated motor.
Residential buildings designed to be operated at a positive indoor pressure of for mechanicalR403.6.2 Ventilation air.
ventilation shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise.
R403.7 Heating and cooling equipment (Mandatory).
Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on theR403.7.1 Equipment sizing.
equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculation
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
AIRFLOW RATE MAXIMUMMINIMUM EFFICACY (a)AIRFLOW RATE MINIMUMFAN LOCATION
CFMCFM/WATTCFM
Any2.8 cfm/wattAnyRange hoods
Any2.8 cfm/wattAnyIn-line fan
< 901.4 cfm/watt10Bathroom, utility room
Any2.8 cfm/watt90Bathroom, utility room
(a) When tested in accordance HVI Standard 916For SI: 1 cfm - 28.3 L/min.
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 10...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
MANDATORY REQUIREMENTS - (Continued)
Cooling only equipment shall be selected so that its total capacity is not lessR403.7.1.1 Cooling equipment capacity.
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Se ction 403.7, or the c loses t ava ilable size prov ided by th e ma nuf ac ture r’s pr oduc t lines . The cor respo ndin g late nt ca pacit y of t he
equipment shall not be less than the calculated latent load.
Th e pub lishe d value f o r A HRI tota l cap acity is a nominal, r ating-test value and shall not b e us ed f o r equ ipme nt siz ing. Manu f actu rer’s
expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity is
less than the calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, the
capacity of equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
Heat pump sizing shall be based on the cooling requirements as calculated according to SectionR403.7.1.2.1 Heat pumps
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
Electric resistance furnaces shall be sized within 4 kW of the designR403.7.1.2.2 Electric resistance furnaces.
requirements calculated according to the procedure selected in Section R403.7.1
The capacity of fossil fuel heating equipment with natural draft atmospheric burnersR403.7.1.2.3 Fossil fuel heating equipment.
shall not be less than the design load calculated in accordance with Section R403.7.1.
Residences requiring excess cooling or heating equipment capacity on anR403.7.1.3 Extra capacity required for special occasions.
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
Systems serving multiple dwelling units shall comply with SectionsR403.8 Systems serving multiple dwelling units (Mandatory).
C4 03 an d C4 04 of the IECC—Commer cial Provis ions in lieu of S ectio n R40 3.
Snow- and ice-melting systems, supplied through energy service to the building,R403.9 Snow melt and ice system controls (Mandatory).
sh all inc lude automatic cont rols c apab le of shut ting o f f the sys tem w hen the p avement tempe ratu re is abov e 50°F (10 °C), a nd n o
pre cipita tion is f alling a nd an auto matic or manua l con trol t hat w ill allow s hutof f w h en th e out door temp eratu re is abov e 40°F (4.8°C).
The energy consumption of pools and permanent spasR403.10 Pools and permanent spa energy consumption (Mandatory).
shall be in accordance with Sections R403.10.1 through R403.10.5.
The electric power to heaters shall be controlled by a readily accessible on-off switch that is anR403.10.1 Heaters.
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
Time switches or other control methods that can automatically turn off and on according to a preset scheduleR403.10.2 Time switches.
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operations.
2. Pumps that operate solar- and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or atR403.10.3 Covers.
the water surface or a liquid cover or other means proven to reduce heat loss.
Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recoveredException:energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required.
All gas- and oil-fired pool and spa heaters shall have a minimum thermalR403.10.4 Gas- and oil-fired pool and spa heaters.
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 11...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
MANDATORY REQUIREMENTS - (Continued)
Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordanceR403.10.5 Heat pump pool heaters.
with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
The energy consumption of electric-powered portable spas shall be controlled by theR403.11 Portable spas (Mandatory).
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
Not less than 75 percent of the lamps in permanently installed lighting fixtures shall beR404.1 Lighting equipment (Mandatory).
high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps.
Low-voltage lighting.Exception:
Fuel gas lighting systems shall not have continuously burning pilot lights.R404.1.1 Lighting equipment (Mandatory).
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
FORM R405-2017
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 12...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Groza Builders, IncBuilder NameHutchings ResidenceProject Name:Permit Office:4800 Seagrape DrStreet:Permit Number:Fort Pierce, FL 34982City, State, Zip:St LucieJurisdiction:Hutchings ResidneceOwner:FL, St Lucie Co IntlDesign Location:
INSULATION INSTALLATION CRITERIAAIR BARRIER CRITERIACOMPONENT
A continuous air barrier shall be installed in theGeneral
requirements Air-permeable insulation shall not be used as abuilding envelope. The exterior thermal envelope sealing material.contains a continuous barrier. Breaks or joints in theair barrier shall be sealed.
The insulation in any dropped ceiling/soffitThe air barrier in any dropped ceiling/soffitCeiling/attic
shall be aligned with the air barrier.shall be aligned with the insulation and any
gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doorsto unconditioned attics paces shall be sealed.
Cavities with corners and headers of frame wallsThe junction of the foundation and sill plateWalls
shall be insulated by completely filling the cavityshall be sealed.The junction of the top plate
with a material having a thermal resistance of R-3and the top of exterior walls shall be sealed.
per inch minimum.Knee walls shall be sealed.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier
The space between window/door jambs and framing,Windows, skylights and skylights and framing shall be sealed.and doors
Rim joists shall be insulated.Rim joists are insulated and include an air
barrier.Rim joists
Floor framing cavity Insulation shall be installedThe air barrier shall be installed at any exposedFloors (including
to maintain permanent contact with the undersideedge of insulation.above-garage and
of subfloor decking, or floor framing cavitycantilevered floors)
insulation shall be permitted to be in contact
with the top sideof sheathing, or continuous
insulation installed on the underside of floor
framing and extends from the bottom to the top of
all perimeter floor framing members.
Where provided in lieu of floor insulation,Exposed earth in unvented crawl spaces shall beCrawl space
insulation shall be permanently attachedcovered with a Class I vapor retarder withwalls
to the crawlspace walls.overlapping joints taped.
Duct shafts, utility penetrations, and flue shaftShafts, penetrations
openings to exterior or unconditioned space shall
be sealed.
Batts in narrow cavities shall be cut to fit, orNarrow cavities
narrow cavities shall be filled by insulation that
on installation readily conforms to the available
cavity spaces.
Air sealing shall be provided between the garageGarageand conditioned spaces.separation
Recessed light fixtures installed in theRecessed light fixtures installed in the buildingRecessed
building thermal envelope shall be air tightthermal envelope shall be sealed to the drywall.lighting
and IC rated.
Batt insulation shall be cut neatly to fit aroundPlumbing and wiring and plumbing in exterior walls, orwiring
insulation that on installation readily conforms
to available space shall extend behind piping
and wiring.
Exterior walls adjacent to showers and tubsThe air barrier shall be installed behindShower/tub on
shall be insulated.electrical or communication boxes or air-sealedexterior wall
boxes shall be installed.
The air barrier shall be installed behindElectrical/phone
electrical or communication boxes or air-sealedbox on exterior
boxes shall be installed.walls
HVAC register boots that penetrate buildingHVAC register
thermal envelope shall be sealed to the subfloorboots
or drywall.
When required to be sealed, concealed fireConcealed
sprinklers shall only be sealed in a manner thatsprinklers
is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be
used to fill voids between fire sprinkler cover
plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 13...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Permit Number:St LucieJurisdiction:
Job Information
Lot:Community:Groza Builders, IncBuilder:
Unit:4800 Seagrape DrAddress:
34982Zip:FLState:Fort PierceCity:
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method.
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceedingPRESCRIPTIVE METHOD 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2.
The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or
R406-2017 (ERI), section labeled as Infiltration, sub-section ACH50.
PERFORMANCE or ERI METHOD
7.000ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI):
Method for calculating building volume:12283_________ x 60 ÷ _______________ = _________
ACH(50)Building VolumeCFM(50)Retrieved from architectural plans
PASS Code software calculated
Field measured and calculatedWhen ACH(50) is less than 3, Mechanical Ventilation installation
must be verified by building department.
Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.R402.4.1.2 Testing.
(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals
licensed as set forth in Section 489.105(3)(f), (g), or (i) or and approved third party. A written report of the results of the test shall be
signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping orother infiltration control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: ___________________________________ Phone: __________________
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: ____________________________________ Date of Test: _____________
Printed Name of Tester: __________________________________________________________
License/Certification #: __________________________ Issuing Authority: _________________
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
FORM R405-2017
2020-Mar-17 07:08:52Section 405.4.1 Compliant SoftwareRight-En ergy ® Florid a 201 7Right-Su ite® U niv er sal 20 19 19 .0.17 RSU2 7054 Page 14...C\4800 Seagrape Dr -Hutchings Residence GBI.rup Calc = MJ8 Front Door faces: N
Duct Leakage Test Report
Residential Perscriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Permit Number:St LucieJurisdiction:
Job Information
Lot:Community:Groza Builders, IncBuilder:
Unit:4800 Seagrape DrAddress:
34982Zip:FLState:Fort PierceCity:
Duct Leakage Test Results
cfm25 (Total)Prescriptive Method_______ cfm25System 1
To qualify as "substantially leak free" Qn Total must be less
than or equal to 0.04 if air handler unit is installed. If air handler
unit is not installed, Qn Total must be less than or equal to
0.03. This testing method meets the requirements in
accordance with Section R403.3.3.
_______ cfm25System 2
_______ cfm25System 3
Is the air handler unit installed_______ cfm25Sum of any
(<= 0.04 Qn)YESadditional systems
(<= 0.03 Qn)NOduring testing?Total of all _______ cfm25systems
cfm25 (Out or Total)Performance / ERI Method
To qualify using this method, Qn must be not greater than the
proposed duct leakage Qn specified on Form R405-2017 or
R406-2017.
1444_________ ÷ _______________ = _________ Qn
Total Conditioned
Square Footage
Total of all
systems
Qn specified on Form R405-2017Leakage Type selected on Form
(Energy Calc) or R406-2017R405-2017 (Energy Calc) or R406-2017FAILPASSDefault Leakage
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set
forth in Section 489.105(3)(f), (g) or (i), Florida Statues.
Testing Company
Company Name: ___________________________________ Phone: __________________
I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: ____________________________________ Date of Test: _____________
Printed Name of Tester: __________________________________________________________
License/Certification #: __________________________ Issuing Authority: _________________
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3
Reference Home Characteristics
Hutchings Residnece Title: 4800 Seagrape Dr -Hutchings Residence GBI TMY City: FL_Fort_Pierce4800 Seagrape DrFort Pierce, FL 34982 FLBase2017
0.084Above-grade Walls (Uo)
0.75Above-grade Wall Solar Absorptance
0.90Above-grade Wall Infared Emittance
n/aBasement Walls (Uo)
n/aAbove-grade Floors (Uo)
0.0Slab Insulation R-Value
0.030Ceilings (Uo)
0.75Roof Solar Absorptance
0.90Roof Infared Emittance
4.81Attic Ve nt Ar ea (ft²)
n/aCrawlspace Ven t Are a (ft²)
368.80Exposed Mason ry Fl oor Area (ft²)
2.0Carpet & Pad R-Value
0.00Door Area (ft²)
n/aDoor U-Factor
0.00North Wind ow Area (ft²)
42.67South Wind ow Area (ft²)
42.67East Windo w Ar ea (ft²)
42.67West Windo w Area (ft²)
0.400Window U-Factor
0.2169Window SHGC (Heating)
0.2169Window SHGC (Cooling)
7.00ACH50
64585Internal Gains * (Btu/day)
60.00Water heater gallons per day
120.00Water Heater set point temperature
0.95Water heater efficiency rating
HSPF = 8.2Labeled Heating System Rating and Efficiency
SEER = 14.0Labeled Cooling System Rating and Efficiency
0.88Air Distribution System Efficiency
ManualThermostat Type
72.0 (All hours)Heating Thermostat Settings
DocuSign Envelope ID: 0DE4E540-6E07-439D-9445-C37AA7165FC3