Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Plans
Dos r%' ys 32 n Channel drain Flat Crate Anti -Entrapment Suction Outlet Cover and Three -Part Manufactured Sump Y G B Series The AquaStar lime of,suction millet covers, compliant with tht Product Speclficatlon'Sheet Virginia Graeme-Baker Pool and Spa Safety Act %SMEJANSI , Features The U!1 b[©Ckab[e!'" A;sWoo, unbEDckable suetIon Q1ltlet'.that evrrtx&<tl,w mw Vr:R mand;Nro and ASMEF WATERLINE I BASIN it 3.9 fps t 2.6fps 3f,ja at 1.5 fog opeD;rf(i toot wawa 0do superior sneered )wtynw rs tom 2*- OD, do 2.a"threaded FPra nhEacltiirinelad With stamp (concrete pOOIS)- Model # 32CDFLXXX GRADE 151 24N OVERFLOW TO FRENCH DRAIN Feet Of Head Two Dra[ns, in 'One!l! -Also available fOr AwWfiberVWs nnadoI B 32CDrLVXxu ANSI-7/15 REC. PUMPIWATER FEATURE PUMP = 1.65 JANDY VARIABLE SPEED LOW SPEED - 36 GPM MAX HIGH SPEED = 97 GPM @ 22 TDH 3" SUCTION PIPE @ 97 GPM = 4.95 FT/SEC. (8 FT./SEC. MAX. - SUCTION LINES) 3" BRANCH PIPE @ 48 GPM = 2.97 FT.ISEC. (6 FT./SEC. MAX. - PRESSURE LINES) 2.5" PRESSURE PIPE @ 97 GPM = 7.18 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) 340 SQ. FT. CARTRIDGE FILTER X 0.375 = 127.50 GPM BACKWASH VALVE NO THERAPY PUMP = 2HP JANDY PHPM JET PUMP LOW SPEED = 36 GPM MAX. HIGH SPEED = 135 GPM @ 54 TDH 3" SUCTION PIPE @ 135 GPM = 5.81 FT./SEC. (8FT./SEC. MAX. - SUCTION LINES) 2.5" PRESSURE PIPE @ 135 GPM = 9.18 FT./SEC. 110 FT_/SFC_ MAX. - PRESSURE LINESI SPA , A_ RETURN LINES FOR • FIRST TEE APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI II APPROVED WITH THE 2017•" • •ING CODE FOR RESIDENTIAL• • 2013 FOR•AVOIDANCE ,rrrrr .rrrrr .rrrrr rrrrrUNBLOCKABLE :rrrrr .rrrrr •rrrrr _________ _ •rrrrr o_�_rrrrr-r�_�_rrrrr�_rrrr�rr.�-rrrrrrrrrr•, /rrrrrrrr ■ ■ ■ rrrrrrrrr_ezrrrr�rrrrv--rrr �. rrrrrrrr rrrrrrrr-r��rrrvrrrr-arrrrrw�wr-rrrrr ' rrrrrrrrrrr��rrr �rrrrr�rrrr► N&rrrrrrr rrrrrrrrrrrr �rrr.�rrrr\{r-rrr �r\{rrrrrr rrrrrrrrrr-rrrarr �rrrr\.rrrr �rr•.rrr-r -rrrrrrrrrrrrrv-r�rrrrr.�rrr �r.{Ir rrrrr ' rrr-rrrrrrrr-rr,.�rr.�r-re.+n.rrr �rr�r.rrr rrrrrrrrrrrrrrrr-arc-�I6L.wx.�rr r rrrrc�rrr - rrrrrr-rrrrrrrrr\rr.��rrlau-�{rr �namtraa rrrrrrrrrrrrr-rrr.�r�{rrrrrrr �mrne!Hr-rrr ' r \ter /rrrr\\ ' ixrrrrrrerrrrrrrrrrc{rN�rrrr�^r .rrrrrrrr Trrrrrrrrrrrrrrrrrr•�rrrrrrn ter------- ' -• ' irrrrrrrrrrrrrrrrrrr�A{rrrrr rrrrrrrrrES �i17rfF'PHEMim rV M SUMPWIT' TEE _ _________ Jandy" PlusHP^ Series High Head Pumps Full Rated (PHPF) and Max -Rated (PHPM) SPA JET PUMP romffmgm 4 181 G.P.M- 1 0 f- 8 FPS MAX 0 20 90 60 80 tU0 131 100 i60 180 .'°'.RmadFww(Gw)-,. "T'O-'JET PUMP HEATER (ELECTRIC HEAT PUMP) - 3-#6 THHN CU WITHIN t6/P TONDUIT GAS HEATER W/341( THHN 2HP JANDY PLUS HP PUMP MOTOR & CU WITH -IN Yz' CONDUIT 1HP VS FLOPRO PUMP W/BUILT-IN OVERLOAD SWITCH W13-#10 THHN CU 80 AMP POOL PANEL WITHIN IZ" MIN. CONDUIT W/(3) - #6 THHN CU WITHIN B/A" ELECTRICAL CONDUIT �I.j 4I7 #8 SOLID CU GROUND WIRE MANUAL MOTOR SWITCH VARIABLE SPEED FLOPRO PUMP MOTOR O TO EXISTING PANEL W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH -IN %" CONDUIT TIME CLOCK S.P.S.T. TOGGLE j W.P. DISCONNECT SWITCH VARIABLE SPEED FLOPRO PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3-#10 THHN CU WITH -IN %" CONDUIT (4) POOL LIGHTS O (GFI NOT REQUIRED) STIME CLOCK DISCONNECT (1) SPA LIGHT IF APPLICABLE JANDY SALT SYTEM (GFI NOT REQUIRED) TIME CLOCK ID _EQUIPMENT LAYOUT N.T.S. 8 FPS MAX. -- --► TO FILTER PUMP W.P. DISCONNECT 9 LEGEND 1. 2.5" WATER FEATURE RETURN LINE 2. 2.5" WATER FEATURE SUCTION LINE A. JANDY 1.65 V.S. FLO PRO W/APPR HAIR & LINT STRAINER 1. ALL ELECTRICAL TO COMPLY WITH 2O17 NATIONAL ELECTRIC CODE. 3.2.5" SPA JET RETURN B. JANDY 1.65 V.S. FLO PRO WIAPPR HAIR & LINT STRAINER S 4. 3" SPA MAIN DRAIN LINE C. 1.5" TO WASTE OR TO GROUND 2.3412 THHN CU WITHIN %" MIN. CONDUIT FOR POOL LIGHT ( ) S. 2" SKIMMER LINE D. JANDY 2.0 P.H.P.M JET PUMP W/APPR HAIR 8 LINT STRAINER 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. S. 2.5" POOL MAIN DRAIN LINE E. VALVES (TYP) 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 B 7. 2" VACUUM LINE F. JANDY CS200 CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE ( ) 8. 2.5" DRAIN FROM SPA G. ELECTRIC HEAT PUMP ELECTRICAL DIAGRAM 9.2.5"SPA RETURN H. JANDY JXI PROPANE GAS HEATER -_.. - ---. -_ - - - -.-- 10. 2.5" POOL RETURN LINE TO FIRST TEE 1. JANDY "AQUA -PURE SALT SYSTEM 18" MIN. ( ENTIRE PERIMETER) PIPING SCHEMATIC MISC. NOTES - - (NO SCALE) PAVER DECK OR CONCRETE DECK i- ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY W L 2. HAND HOLD TO BE INSTALLED AT AREA WHERE DECK RAISED .6- ABOVE POOL �T-- #8 GROUND WIRE RETURN LINE .SOIL I HANDRAIL BONOMG DETAIL 712"MAX. WHERE APPLICABLE WASA� 48" MAX WATER PER NATIONAL ELECTRICAL CObE ABSOLIDCOPPERBOND _ WIRE Wl APPR. CLAMPS DEPTH. (ONE ON EACH SIDE OF - I-10"MIN. c SKIMME POOL 4 TOTAL ) 8 GAUGE SOLID COPPER WIRE- CP o STEP DETAIL 1.TREAD15MIN.OFUrWIDE. (1)CF�ANNEL 2. RISER NOT GREATER THAN USED- 1. DRAIN, - e IF MORETHANTREADS ARE USED. 3. ALL STEPS TO BE SOLID EQUIPOTENTIAL BONDING GRID DETAIL MINIMUM 18" FROM EDGE OF POOL NO FURTHER THAN GUNITE am PSI. 24" AROUND ENTIRE POOL PERIMETER BURIED W TO 6" PER N.E.C. 2017 SEC. 680.26 DEEP STEP DETAIL % (WHERE ADOPTED) N-Ts. F_OOTER DETAIL (2) #3 REBAR CONTACT WITH AN APPROVED CORROSION -RESISTANT CONDUCTIVE SURFACE THAT EXPOSES NOT LESS THAN 9 INCHES (5800 MM) OF SURFACE AREA TO THE POOL WATER AT ALL TIME. MUST HOLD 35 PSI FOR AT NOTE: POOL PUMP MOTOR LOCATED ABOVE EAST30MIN. ELECTRICAL DIAGRAM AND GFI GRADE. PROVIDE SEPARATE CIRCUIT FOR OUTLET PER 2017 NEC PUMP MOTOR(S)AND HEATER(S) ETC NOTE: REMOVE GRATE & (NO SCALE) WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP - RAIN TIGHT OUTDOOR NOTE: INSTALL 125V 1.5 LINE WHEN EMPTYING POOL - -ELECTRICAL PANEL AMP WEATHERPROOF 6"X6" TILE (SIZED PER LOAD) DUPLEX RECEPTACLE AT • TO MAIN SERVICE PANEL IN APPROVED ONDUIT SIZED G F 1 LEAST 1W AWAY AND OUTLET NOT MORE THAN 20' INTERIOR PER LOAD) GRATE SHALL FINISH rOOOR TIME-C KFROM THE INSIDE WALL BE SECURED IN WRING TO POOLIIGHTIN OF POOL ;GAUGE) APPROVED CONDUIT PUMP PLACE SO MOTOR THAT TOOLS ULAPPROVEDDECKBOX ARE REQUIRED FOR DIRECT CONNECT1 TO WET NICHE NOTES: (1)POOL PANELHE FOR REMOVAL INSI EWALLTCHES FTBE OLEAST 5' FROM THE INSIDE WALL OF THE POOL (2) ALL ELECTRICAL WIRING AND EQUIPMENTPOOLU HISWITCHMUST INSTALLED IN ACCORDANCE WITH THE UNDERWATER EITHER INDOOR OR 2017EDITIONOFTHE NAT10NALELECTRICAL THREADE LIGHT OUTDOOR CODE HAIR & LINT APPROVED WIRING IN 1" ' PLUG SCH 0 PVC WI LIB (3) PROVIDE PROPER WORKING CLEARANCE CATCHER BONDING CONDUCTOR SPACES FOR ELECTRICAL EQUIPMENT AS PER TOPUMP -► (COMPONENT OF PUMP) HO-26 OF NFPA 70 GRAVEL BED 1/4" PER FT. SLOPE -�� WATER LEV�E�L VERTINEPOQ� 10 g TYPICAL WALL SECTION 8L UNDERWATER 1 WELL POINT LlGrlr (NO SCALE) FEEL-TEX FORM R KRAFT WALL @ 12" O.C.B.W. UPPER AND LOWER MATT POOL FINIS O-� 'P9y2Fo c POOL PATIO 1 NIrL6 r6Y6-LnE- ,3.5' FROM R 1" LIGHT POWER #3 REBAR 12 O1C CONDUIT SUPPLY FLOOR SLOP_01 1 UNDERWATER FLOOR eE REASONABLY UNIFORM AND LIGHT DETAIL COMPLY WITH ARTICLES 5.61 (NO SCALE) TMH115.6.J CYCOLAC MAIN DF GROUND CLAMP THE SLOPE OF THE FLOOR FROM 27P THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL inIINUOUS BOND WIRE NOTEXCEEDIFOOTIN7F K 1- 30. )MMON TO POOL STEEL, RAILS & EQUIPMENT TYPICAL SECTION THRU POOL (NO SCALE) • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 61h EDITION SPECIFICATIONS MAX. WIDTH 20' MAX. LENGTH 30' _ MIN. DEPTH 3.5' MAX. DEPTH 6' SHAPE CUST ELEVATION T B.D_ FILL FROM EXCAVATION NA TILE GEM FINISH GEM FILTER CS200 - -_ _ - --- PU_MP MAKE PER FBC 4501.20 PUMP HP: PoOLr WATER FEATURE IX5 FLO PRO TIMER INCL SPA 2.0 PHPM LIGHTS POOL (4) COLOR LED$PA 1 COLOR LED TRNFORM: POOL 1 300 WATT SPA 100 WATT SPA SIDE CONTROLLER INCL REMOVE EXISTTING CONCRETE NA_ PUMP POOL PATIO NA SCREEN ENCLOSURE PIONEER SCREENS ELECTRICAL ED'S ELECTRIC POOL PATIO TRAVERTINE PATIO EXISTING PATIO REMOVE EXISTING, INSTALL TRAVERTINE DECK DRAIN INC GALLON CAPACITY -POOL 18,680 GAL. GALLON CAPACITY -SPA 880 GAL. TURN -OVER TRERATE_ _ 6 hrs TERMITE AT INC gARR1ERINA MAX. WATER VELOCITY - 6 ft./s FROM TRUNK LINES TO 8 ft./S SUCTION LINES,-10n0fps MAX RETURN LINE SKIMMER MIN. FLOW 25 GPM GENMALNOTES: CLAMMING POOLPANSTIN CIIOX TOCOMWLY WIFu. BLaG CODEMOmm ALL LOCAL ORDINANCES AND MNING BEGMATIOxS. R.SWIMMSLPo0.NBFAROH ROGM ORMSNRBEp6 ARN WpLLSA,M FLOOR6 SMALL BE GIMIIEO ORPoOREp MJAIACE ROMPED IMHAMIRAMS P$AMANCRETEMgi60AY81 COXPRISMVESIREXGTN. S.E NDIRSMALLBEXOTRIEOC SOLLBEPPMXS L.5TXANMBODF.EMVCN.SILTORL008E. 60FTBOIL ISFgIND.ASOTEARAWNOCPPPCR MU'L P.6.F.XP6BEEN YBEp WTMEpESgN. X.REMPORCMGBARS SHAM. B. NEWDB_ET, haw!MD. S.ALLPJAB PWMGTOBEP.tlF.SCNEDBLEXS MIN. AXD BEARTIINSF. PPPROVAL. BACMYiP6M.L.AMRSMPLMNCENRMLOGLONp,XANCES. T. DRPoEALOFR. WPIERSIULLMO SMLLLTPLOROMAk BUg ANC Ep kSXPLLCONTAM WPTERVATMMPROPERMALS.PoNOINGSNALLHpTP ATTFORMMiETNANONENOVR B. WATERSVPPLYS DRPO.S R PATERREMBTALLEO60 T,PTTXEREIe XOCRO66COXHEC1gX N1TX P OpMEeTICWRIERSRANWiWATERAFMEAL8Y5 4X S. HAR ALIMS DRAMSMALLNAVEp FI6EEPREPOF1FTHEAREAOFTHE6FRUARI TUIHER65MALLXAVEP REMOVABLE SCREEN WIAAYNIMVMFgEE PpEi OF iXTMEAREP DF TXESULTEXLAM. LE 11.ECIACARWPLINSTALL WIMNG SOEVILEE PSSXOWN M "POM DATA" HEREON. 41GNi COHNECMN M CONFORM TO HATN,NPL ELECIIULPLCODFIAIEST EMIpN. OCEPER iL ALL METYIIC COXMIR6. PMS6O EYeIEM& REMFORCEp SLEEL YOMI FMTURES B IpU3 W G. L@FAL PPRR CF LA W ER& MAHMULA DIVMG BOAg05 S 6UPPORI6 TO BE BGHOEL TIX3ETIFP & 6ROuxom Ta w COMMONGRNMAO BON DWOLONDUCTORBXALL NOTBE S1MIlPR'111RXM COPPER 1S. XPmioeFAOOPEM WIRE OVER PWL WATER. M. CARIRIOOE FILTER SXPLL NPVE P FILTRATION RATE NOT TO EFCEw J D.P.M. I B.F.OF FILTER AREA. NO BAcgaAsx MEAYIREp. B.CONIWCM MALL VERIFY ALL DIMENSIONS AND CIXEASTONE AT SIZE BEFORE ETARTNGIME PROJECT, CONTRACTOR SHALL V EMY LOCATION OF ELECTRICAL SERVICE BY FJRAL COMPANY. 16. SPEMAL ATTENTION SMALL BE S EN TO EXISTING FOUNDATION TO PMYENT UNDERMINING. A. ALLEN ENGINEERING LLC, CA NO. 33042, 2367 7TH STREET, LA VERNE, CA, 91760 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY MINIMUM BUILDING CODES. J of Aaron H. Allen PE. FL Reg, No. 86620 FL JOB NAME: SIX RESIDENCE ADDRESS: 8208 KIAWAH TRACE PERMIT NO.: DATE DRAWN: JANUARY 20, 2020 DRAWN BY: TRAVIS LEONARD DESIGNER APPROVAL: CHECKED BY: AARON H. ALLEN SCALE: 1l4" = 1' i rCONC 1�8TE POOLS, �14C. 1 ROW OF WATERLINE 3' 1/2" THICK WAS SHALL NOT SLOPE GREATER THANII