Loading...
HomeMy WebLinkAboutEnergy CodeBBraden & Braden, AIA, PA AL, Y" #AAc000032 417 Coconut Ave. Stuart, FL 34996•(772) 287-8258 St. Lucie County Building Dept. Wynne Development Date. \�� \-;i� Address.\ �,D �-e Permit #, <) I P'�- To whom it mag concern, This detail applies to the insulation in the ends of the vaulted ceilings. If you have any questions please feel free to call me at -1-12-28-1-8258 R-19 S Braden ! LRECEIVED] CL 2 4 '0runtrf'E Trusses at 24" o.c. V shop drawings bg others ceiling transition kf'� ded using metal studs erifil exact configuration es W CCZN OQ5 W W O i� yVED WWJ �O� O R-30 Batts 9 batts Drywall ceding see typical section Ceiling transition Insulation Detail nts b M. MIN; SETBACKREO. FRONT IO SIDES IL CNR SIDES _A REAR O erJ LUAU d (rwli w ZNG. e . 1. TECH. x' " Qt FILE C®PYAN as FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE MANOR IMPACT ^ Builder Name: WYNNE BUILDING CORP. Street: THE MANOR 71 �R.�.,•"..,, , _ Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. .PIERCE, FL, ` '•� Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1664.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insui, Exterior R=4.1 1374.20 ft' b. Frame - Wood, Adjacent R=11.0 280.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. WA R= ft' G. Is this a worst case? Yes 10. Ceiling Types (1754.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1724.00 ft' 6. Conditioned floor area above grade (ft=) 1724 b. Knee Wall (Vented) R=19.0 30.00 ft' Conditioned floor area below grade (ft= 0 c. N/A R= fN 11. Ducts R ft' 7. Windows(153.4 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 150 a. U•Factor: Sgl, U=1.04 113.35 ft' SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft' 12. Cooling systems - kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: WA ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted AverageOverhangDepth: 3.010 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1723.5 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1723.50 ft b. Conservation features EF: 0.950 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.089 Total Proposed Modified Loads: 53.45 PASS Total Baseline Loads: 54.12 I hereby certify that the plans and specifications covered by Review of the plans and TiiESTq this calculation are in compliance with the Florida Energy specifications covered by this z p Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed r "' DATE: 1-9-20 this building will be inspected for compliance with Section 553.908 a hereby certify that this building, as designed, is in compliance Florida. Statutes. with the Florida Energy Code.Cal1.WE Tg OWNER/AG NI: BUILDING OFFICIAL: DATE: K! DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and insulation Inspection Ch l�ac nc� this project requires an envelope leakage test report with envelope leakage no greater. tha�A�TH502gt.1.2p REVIEWED FOR COPE COMPLIANCE 1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 F C 6th di io 1 C m i o e Page 1 of 6 S1 L[7619 66b Y BOCC FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE MANOR IMPA Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1724 Lot # Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Bldck/Subdivislon: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 270 Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range _ FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1724 14774.8 SPACES .Number Name. Area Volume Kitchen Occupants Bedrooms In611D Finished Cooled Heated 1 GREAT ROOM 546 5350.8 No 0 1 Yes Yes Yes 2 MASTER BEDROO 354 2832 No 2 1 1 Yes Yes Yes 3 WIC 77 616 No 0 1 No Yes Yes 4 CLST. 35 280 No 0 1 No Yes Yes 5 M BATH 54 432 No 0 1 Yes Yes Yes 6 KITCHEN 180 1440 Yes 0 .1 Yes Yes Yes 7 JUNIOR M. BED 198 1584 No 0 1 1 Yes Yes Yes 8 BATH 50 400 No 0 1 No Yes Yes 9 POWDER 35 280 No 0 1 Yes Yes Yes 10 NOOK 42 336 No 0 1 Yes Yes Yes 11 LAUNDRY 49 392 No 0 1 Yes Yes Yes 12 ENTRY 104 832 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Insulatio GREAT ROOM 47 ft 0 546 ft2 0 1 0 2 Slab -On -Grade Edge Insulatio MASTER BEDRO 46 ft 0 354 fV 0 1 0 3SIab-On-GradeEdge Insulatio WIC 1ft 0 77 ft' s_ 0 1 0 4SIab-On-Grade Edge Insulatio CLST. 1 ft 0 35 ft' _ 0 1 0 5 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 54 ft- _ 0 1 0 1/8/2020 4:31 PM EnergyGaugeO USA 0.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS V. # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 180 ft' _ 0 1 0 7SIab-On-Grade Edge Insulatio JUNIOR M. BED 14 ft 0 198 ft' ____ 0 1 0 8SIab-On-Grade Edge Insulatio BATH 1 It 0 50 ft' _ 0 1 0 9 Slab -On -Grade Edge Insulatio POWDER 5 It 0 35 ft' ___ 0 1 0 10SIab-On-Grade Edge Insulatio " NOOK E ft 0 42 ft' 0 1 0 _ 11Slab-On-Grade Edge Insulatio LAUNDRY 17 ft 0 49 ft' _ 0 1 0 12SIab-On-Grade Edge Insulatio ENTRY 5.9 ft 0 103.6 ft' _ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emilt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1817 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 300 1724 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) GREAT ROOM 30 Blown 546 ft' 0.1 Wood 2 Under Attic (Vented) MASTER BEDRO 30 Blown 354 ft' 0.1 Wood 3 Under Attic (Vented) WIC 30 Blown 77 ft' 0.1 Wood 4 Under Attic (Vented) CLST. 30 Blown 35 ft' 0.1 Wood 5. Under Attic (Vented) M BATH 30 Blown 54 ft' 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) JUNIOR M. BED 30 Blown 198 fF 0.1 Wood 8 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 9 Under Attic (Vented) POWDER 30 Blown 35 ft' 0.1 Wood 10 Under Attic (Vented) NOOK 30 Blown 42 ft' 0.1 Wood 11 Under Attic (Vented) LAUNDRY 30 Blown 49 ft' 0.1 Wood 12 Under Attic (Vented) ENTRY 30 Blown 104 ft' 0.1 Wood 13 Knee Wall (Vented) GREAT ROOM 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height She Framing Solar Below n 1 SW=>SE Exterior Concrete Block- Int InSGRE4T ROO 4.1 26 ' 0 9 10 255.7 ft- 0 0 0.3 0 2 NW=>S Exterior Concrete Block - Int InsOREAT ROO 4.1 21 0 9 10 206.5 ft' 0 0 0.3 0 3 NE=>NW Exterior Concrete Block- Int Ins81ASTER BE 4.1 25 0 8 0 200.0 ft' 0 0 0.3 0 1/8/2020 4:31 PM EnergyGauge® USA 6.0.02(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY GHFCKI 1ST RFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 -4 SW=>SE Exterior Concrete Block- Int InSNASTER BE 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 5 NW=>S Extedor Concrete Block- Int InsttEASTER BE 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 8 NE ->NW Exterior Concrete Block - Int Insul M BATH 4.1 9 0 8 0 72.0 ft' 0 0 0.3 0 7SW=>SE F)der or Concrete Block- Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 8 NE=>NW Exterior Concrete Block- Int InsdUNIOR M. B 4.1 14 0 8 0 112.0 ft' 0 0 0.3 0 _9 SW=>SE Exterior Concrete Block -Int lnsulPOWDER 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 _10 SW=>SE Exterior Concrete Block- Int Insul NOOK 4.1 6 0 8 0 48.0 ft' 0 0 0.3 0 11 NE=>NW Exterior Concrete Block- Int Insul-AUNDRY 4.1 3 0 8 0 24.0 ft' 0 0 0.3 0 _ 12 SE=>NE Exterior Concrete Block- Int Insul-AUNDRY 4.1 7 0 8 0 66.0 ft' 0 0 0.3 0 _13 SW=>SE Exterior Concrete Block- Int Insul-AUNDRY 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 _ 14 SE=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 R' 0 0 0.3 0 _15 N=>W Garage Frame -Wood ENTRY 11 35 8 280.0 ft' 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NE Insulated ENTRY None .32 3 6 8 20 ft' WINDOWS Orientation shown Is the entered orientation => changed to Worst Case. / Wall Overhang , V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 SW=>SE 1 Metal Low-E Single Yes 1.04 0.29 N 46.4 ft' 1 ft 0 in 1 ft 5 in None None 2 NW=>SW 2 Metal Low-E Single Yes 1.11 027 N 40.0 ft' 8 It 0 in 1 It 5 In None None 3 NW=>SW 5 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft' 1 It 0 In 1 ft 5 In None None 4 NE=>NW 6 Metal Low-E Single Yes 1.04 0.29 N 6.9 it' 1 ft 0In 1 ft 5In None None 5 NE=>NW 8 Metal Low-E Single Yes 1.04 029 N 16.2 IF 1 ft 0 in 1 ft 5In None None 6 SW=>SE 9 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in None None 7 SE=>NE 12 Metal Low-E Single Yes 1.04 0.29 N 4.7 ft' 7 It 0 in 1 ft 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft 440 ft' 35 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000272 1231.2 67.59 127.12 .097 5 1/8/2020 4:31 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singi HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singi SEER:15 34.8 kBtulhr 1044 drn 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SelPnt Conservation _ 1 Electric None Garage 0.95 =50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 i12 Attic 451P Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablfe,Thermostat: Ceiling Fans: ��Y r ]] Heating Jan [X] Feb Mar [ ] l J [ ] �X I May rl Jun rj Jul [ Aug [X] [ ]Sep Oct t Nov Dec Venting [ 1 Jan [[ 11 Feb IX Mar l l l lnl r [ Jun [ 1 Jul I Aug f.) Sep l�l Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 68 68 68 PM 68 68 68 66 68 68 66 66 Healing (WEH) 68 68 68 68 68 PM 68 68 68 68 68 66 66 MASS Mass Type - Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Defsult(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(B lbs/sq.ft. ft2 ft 0.3 LAUNDRY 1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 1182020 4:31 PM EnergyGauge® USA 6.0.02:(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MANOR IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. WYNNE BUILDING CORP. Jurisdiction: w Design Location: FL, Fort Pierce X COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a. continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The Insulation in any dropped ceilin dro ed soffit 9l the insulator and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wail doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambsand framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous Insulation Installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, Insulation a Class I vapor retarderwith overlapping joints taped. shall be permanently attached to the cravdspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities - cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and Wrino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids glates and walls or cell*nos- u cuummy uwpcumu m my wain Clldll WC III dU6UIUGIIW wlul Ulu plulfiwun5 ur i dr UU. 1/8/2020 4:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 5. Is this a worst case? (yes/no) 5. Yes 6. Conditioned floor area (sq. ft.) 6. 1724 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 c) Area 7c. 153.4 8. Skylights a) U-factor.(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floortype, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unittPTAC EER e) Other 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 8.50 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10B1. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. \ Builder Signature: Date: Address of New Home: THE MANOR 71 V,.A r City/FL Zip: FT. PIERCE, FL 1/8/2020 4:36:22 PM EnergyGaugeO USA 6.0.04 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compllant Software Page 1 of 1