Loading...
HomeMy WebLinkAboutEnergy CodeBraden & Braden, AIA, PA RECEIVED JAN 2 4 2020 IBA&P& GodAf3 � Fern [,C #AAC000032 N 417 Coconut Ave. Stuart, FL 34996 • (772) 287-8258 ®� o w�'�c�i 0LU0 St. Lucie County Budding Dept. �= V L Wynne Development Date: \�\�\a -c) Address: CaA�-R Permit #: 'C\ To whom it mag concern. This detail applies to the insulation in the ends of the vaulted ceilings. If you have any questions please feel free to call me at 7i2-287-8258 Zn rRBraden AIA Braden t Braden AIA PA 0 R-19 Cellin Trusses at 2-4" o.c. re shop drawings bg others ceiling transition '� ded using metal studs erdy exact configuration .es translti a v LU J LL R-30 Batts —19 batts Drywall ceiling see typical section nts Jr. P4+,% 27, sri o 3 .. ISat1 c& � w • �i FILE COPY . /. MIN, SETBACK REQ. FRONT SIDES- I S/s CNR SIDES REAR QnCI U!c{CI ',TECH. 'Adu/ae FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: \!i�_ (o, \,,S Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, �" Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST: LUCIE COUNT`( _ Design Location: FL, Fart Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d.WA R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1476.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned floor area above grade.(115 1446 b. Knee Wall (Vented) R=19.0 30.00 ft' Conditioned floor area below grade (ft'j 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor. Sgl, U=0.54 101.25 112 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.55 40.00 ft' 12. Cooling systems kBtufhr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor. WA ft' SHGC: 13. Healing systems kStufhr Efficiency d. U-Factor. WA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. " Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1445.5 sgft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features b. NIA R= ft' None c. NIA R= ft' 15. Credits Patel Glass/Floor Area: 0.098 Total Proposed Modified Loads: 46.72 PASS PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of the plans and F SHES$q� this calculation are in compliance with the Florida Energy specifications covered by this y0 _ _ Code. calculation indicates compliance �A0 with the Florida Energy Code. f^ Nm '. 'M. ;; PREPARED BY: Before construction is completed w DATE: 1-8-20 this building will be inspected for compliance with Section 553.908 l� - I hereby certify that this building, as designed, is in compliance Florida Statutes. !,y with the Florida Energy Code. OWNER/A4(ENT• BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope, leakage test report with envelope leakage no greater than 7.00 CHIP J5,W.4.1.2). I���IEw�b 7'GJC't CODE COMPLIANCE ST. LUCIE � COUNTY 1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes20t47F8( Qr2 ition (2017) Comrams eCO Page 1 of 5 'FORM R40572017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlalBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: ' Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1636 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREATIDINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52ft 0 301 ft' 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 It, 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 W — 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft- — 0 1 0 5SIab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' — 0 1 0 7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' _ 0 1 0 1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R,Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft' ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 _ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pilch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) BEDROOM 30 Blown 3011t' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood _ 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood _ 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood _ 9 Under Attic (Vented) GREATIDINING 30 Blown 488 112 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _ 2 SW=>NE EMedar Concrete Block - Int Insr6EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 _ 3 NW=>SE Exterior Concrete Block- Int Insu8EDR00M 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 _ 6 NE=>SW Extedor Concrete Block - Int InsEKEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 _ 7 SE=>NW Exterior Concrete Block- Int InsBEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block - Int InsSEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block - Int InsMOROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block -Inl Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 _ 11 SW=>NE Extedor Concrete Block- Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 _ 12 SW=>NE Exterior Concrete Block- Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Int InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block- Int lns2REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 'FORM R405-2017 INPUT. SUMMARY.'CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame -Wood .KITCHEN 11 24 .8 192.0 ft' 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation _> changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal _ 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal _ 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 5 in Drapesiblinds 0.54 0.25 N 6.9 ft' 1 ft 0 in 1 ft 5 in None 0.54 0.25 N 24.0 ft' 6 ft 0 in 1 ft 5In None 0.54 0.25 N 37.5 ft' 1. ft 0 in 1 ft 5 In None 0.55 0.25 N 40.0 W 8 ft 0 in 1 ft 5 In Drapeslblinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall;Perimeter Avg. WaIGHeight Exposed Wall Insulation 1 315 ft' 315 ft' 24ft lift 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.84 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:6:5 34.8 kBtuthr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency ..Capacity Air Flow SHR Block Ducts 1 Central Unill Split Singl SEER: 15 34.8 kBtuthr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SelPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None 1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / —Supply— —Return Air AFM 25, CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft- Attic 65 ft2 Default Leakage Attic (Default) : (Default). 1 1 TEMPERATURES i Programable'Thermostal: Y Ceiling Fans: Cooling�]] Jan [[ �Feb HeatinIxl Jan [x] Feb [[ �Mar (x] Mar [ 7 Apr [ ] Ap` [[` May �XI Jun [ t Jun �c] Jul [ ] Jul [x] Au [.] Aug- [X1 ( Se ]Oct ] Sep LJ .Nov rD('1 Dec Venting [[ 11 Jan [[ II Feb [(fix]) Mar [xl l [ May I ) Jun [ 1 Jul [ ) Aug [) Sep lxl Oct Xm Nov [ ]Dec ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling.(WD) AM n 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68. 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area - Thickness Furniture Fraction Space Default(8 lbslsq.fL 0 112 0 ft 0.3 GREAT ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 lbs/sq.fL ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3' CLST. Default(8 lbslsq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Defauit(8.lbslsq,ft. ft2 ft 0.3 JUNIOR M. BED Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. 112 ft 0.3 POWDER Default(81bs/sq.fL ft2 ft 0.3 NOOK Default(8 lbs/sq.ft. ft2 ft' 0.3 LAUNDRY Default 81bs/s .ft, ft2 ft 0.3 ENTRY 1/8/2020 2:47 PM EnergyGaugeED USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition(2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY = Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Cellinglattic The air barrier in any dropped ceilingisoffit shall be aligned with /soffit' wiling/soffit' The insulation in an droppedg the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier, Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sit] plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having athernal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope. insulation for framed wails shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambsand framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installedoo (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where, provided instead of floor Insulation, Insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures Installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the. drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or Insulation that on Installation readily conforms to available space shall extend behind pinina and rina Showerltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400. 1/812020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower. the Energy Performance Index, the more efficient the home. 1. New home or, addiflon 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b). Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity i 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c), Concrete, raised (R-value) 9c: a) Electric resistance EF 0.97 b). Gas fired; natural gas EF 10. Wall type and insulation: c), gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b)Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy savingfeatures which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: =7=- Date: Address of New Home"�`<<� �� S City/FL Zip: FT. PIERCE, FL. 1/8/2020 2:47:26 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1