HomeMy WebLinkAboutEnergy CodeBraden & Braden, AIA, PA RECEIVED
JAN 2 4 2020
IBA&P&
GodAf3 � Fern
[,C #AAC000032 N
417 Coconut Ave. Stuart, FL 34996 • (772) 287-8258 ®� o
w�'�c�i
0LU0
St. Lucie County Budding Dept. �= V
L
Wynne Development
Date: \�\�\a -c)
Address: CaA�-R
Permit #: 'C\
To whom it mag concern.
This detail applies to the insulation in
the ends of the vaulted ceilings.
If you have any questions please feel
free to call me at 7i2-287-8258
Zn
rRBraden
AIA
Braden t Braden AIA PA
0
R-19
Cellin
Trusses at 2-4" o.c.
re shop drawings bg others
ceiling transition '�
ded using metal studs
erdy exact configuration
.es
translti
a
v
LU
J
LL
R-30 Batts
—19 batts
Drywall ceiling
see typical section
nts
Jr.
P4+,%
27, sri o
3 .. ISat1
c&
� w •
�i FILE COPY
. /.
MIN, SETBACK REQ.
FRONT
SIDES- I S/s
CNR SIDES
REAR QnCI U!c{CI
',TECH.
'Adu/ae
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
Street: \!i�_ (o, \,,S
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, �"
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST: LUCIE COUNT`(
_
Design Location: FL, Fart Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d.WA
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft'
6. Conditioned floor area above grade.(115 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft'
Conditioned floor area below grade (ft'j 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor. Sgl, U=0.54 101.25 112
SHGC: SHGC=0.25
b. U-Factor. Sgl, U=0.55 40.00 ft'
12. Cooling systems
kBtufhr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor. WA ft'
SHGC:
13. Healing systems
kStufhr Efficiency
d. U-Factor. WA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
"
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1445.5 sgft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft'
b. Conservation features
b. NIA R= ft'
None
c. NIA R= ft'
15. Credits
Patel
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 46.72
PASS
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
F SHES$q�
this calculation are in compliance with the Florida Energy
specifications covered by this
y0 _ _
Code.
calculation indicates compliance
�A0
with the Florida Energy Code.
f^ Nm '. 'M. ;;
PREPARED BY:
Before construction is completed
w
DATE: 1-8-20
this building will be inspected for
compliance with Section 553.908
l� -
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!,y
with the Florida Energy Code.
OWNER/A4(ENT•
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope, leakage test report with envelope leakage no greater than 7.00 CHIP J5,W.4.1.2).
I���IEw�b 7'GJC't
CODE COMPLIANCE
ST. LUCIE � COUNTY
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes20t47F8( Qr2 ition (2017) Comrams eCO Page 1 of 5
'FORM R40572017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
#of Units: 1 Worst Case: Yes
PlalBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street: '
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1636 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREATIDINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52ft 0
301 ft'
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 It,
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 W
—
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft-
—
0 1
0
5SIab-On-Grade Edge Insulatio BATH 5 ft 0
45 ft-
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft'
—
0 1
0
7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
_
0 1
0
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R,Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft'
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft
0
488 ft2
_
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pilch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
_ 1 Under Attic (Vented) BEDROOM
30
Blown
3011t'
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
_ 4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
_ 8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
_ 9 Under Attic (Vented) GREATIDINING
30
Blown
488 112
0.1
Wood
10 Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft'
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 2 SW=>NE EMedar Concrete Block - Int Insr6EDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
_ 3 NW=>SE Exterior Concrete Block- Int Insu8EDR00M
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
_ 5 NE=>SW Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
_ 6 NE=>SW Extedor Concrete Block - Int InsEKEDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.4
0
_ 7 SE=>NW Exterior Concrete Block- Int InsBEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 8 S=>N Exterior Concrete Block - Int InsSEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block - Int InsMOROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block -Inl Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
_ 11 SW=>NE Extedor Concrete Block- Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
_ 12 SW=>NE Exterior Concrete Block- Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int InsGREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block- Int lns2REAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
'FORM R405-2017 INPUT. SUMMARY.'CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
15 N=>S Garage Frame -Wood
.KITCHEN 11 24 .8 192.0 ft' 0.23 0.4
0
DOORS
# Omt
Door Type
Space
Storms U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1 6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation _> changed to Worst Case.
/ Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
_ 2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
_ 4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 5 in Drapesiblinds
0.54 0.25 N 6.9 ft' 1 ft 0 in 1 ft 5 in None
0.54 0.25 N 24.0 ft' 6 ft 0 in 1 ft 5In None
0.54 0.25 N 37.5 ft' 1. ft 0 in 1 ft 5 In None
0.55 0.25 N 40.0 W 8 ft 0 in 1 ft 5 In Drapeslblinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall;Perimeter Avg. WaIGHeight Exposed Wall Insulation
1 315 ft'
315 ft'
24ft lift 11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.84 .1233 7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1 Electric Heat Pump/
Split
Sing] HSPF:6:5 34.8 kBtuthr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency ..Capacity Air Flow SHR Block
Ducts
1 Central Unill
Split
Singl SEER: 15 34.8 kBtuthr cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SelPnt Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg None
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System
Model #
Collector Model
#
Area Volume
FEF
None None
ft2
DUCTS
/ —Supply—
—Return
Air
AFM 25, CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT ON
RLF
Heat Cool
1 Attic
6 250 ft-
Attic
65 ft2
Default Leakage
Attic
(Default) : (Default).
1 1
TEMPERATURES
i
Programable'Thermostal: Y
Ceiling Fans:
Cooling�]] Jan [[ �Feb
HeatinIxl Jan [x] Feb
[[ �Mar
(x] Mar
[ 7 Apr
[ ] Ap`
[[`
May
�XI Jun
[ t Jun
�c] Jul
[ ] Jul
[x] Au
[.] Aug-
[X1
(
Se ]Oct
] Sep LJ
.Nov
rD('1 Dec
Venting [[ 11 Jan [[ II Feb
[(fix]) Mar
[xl
l
[
May
I ) Jun
[ 1 Jul
[ ) Aug
[)
Sep lxl Oct Xm
Nov
[ ]Dec
ThermostatSchedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling.(WD) AM
n
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68.
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
-
Thickness
Furniture Fraction
Space
Default(8 lbslsq.fL
0 112
0 ft
0.3
GREAT ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 lbs/sq.fL
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3'
CLST.
Default(8 lbslsq.ft.
ft2
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Defauit(8.lbslsq,ft.
ft2
ft
0.3
JUNIOR M. BED
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
112
ft
0.3
POWDER
Default(81bs/sq.fL
ft2
ft
0.3
NOOK
Default(8 lbs/sq.ft.
ft2
ft'
0.3
LAUNDRY
Default 81bs/s .ft,
ft2
ft
0.3
ENTRY
1/8/2020 2:47 PM EnergyGaugeED USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition(2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
=
Design Location: FL, Fort Pierce
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Cellinglattic
The air barrier in any dropped ceilingisoffit shall be aligned with
/soffit'
wiling/soffit'
The insulation in an droppedg
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier,
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sit] plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having athernal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope. insulation for framed
wails shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambsand framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installedoo
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where, provided instead of floor Insulation, Insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the. drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or Insulation that on
Installation readily conforms to available space shall
extend behind pinina and rina
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400.
1/812020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower. the Energy Performance Index,
the more efficient the home.
1. New home or, addiflon
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b). Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
i
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c), Concrete, raised (R-value)
9c:
a) Electric resistance EF
0.97
b). Gas fired; natural gas EF
10. Wall type and insulation:
c), gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b)Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
savingfeatures which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: =7=- Date:
Address of New Home"�`<<� �� S City/FL Zip: FT. PIERCE, FL.
1/8/2020 2:47:26 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1