HomeMy WebLinkAboutHealth Dept. final approvalSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Kari Rohan AGENT: Brian Davis (Brian Davis Septic) PROPERTY ADDRESS: 7204 Shanas Trl Port Saint Lucie, FL 34952 APPLICATION #:AP1428308 PERMIT #:56 -SF -1982013 DOCUMENT #:F11424944 DATE PAID:08/12/2019 FEE PAID:545.00 RECEIPT #:56 -PID -4052302 LOT: BLOCK: 2 SUBDIVISION: St. Lucie Gardens ID#: 3414-501-1008-200-3 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS 100 FT [ ] [04] MULTI-CHAMBERED [LZJ N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL -68 [ ] [31] IRRIGATION WELLS 61 FT [ ] [06] LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 56 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 6 FT ( ] [08] LEVEL [ ] [34] PROPERTY LINES 54 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] (10] AREA [1] 667.88 [2] SQFT [ ] [36] DRAINFIELD COVER ( ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 6.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 05/12/2020 [ ] [14] DRAINLINE SLOPE [ ] (15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOw ]BM 1.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS ( ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR Brian Davis (Brian Davis Sept [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED ( ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. / St. Lucie CHD DATE: 02/21/2020 CONSTRUCTION I APPROVED DISAPPROVED Environ ntal Specially rian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM ( APpROVED / DISAPPROVED ]: St. Lucie CHD DATE: 05/12/2020 Environmental Spec iali I Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1428305 EID1982013 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1428305 PERMIT #:56 -SF -1982013 DOCUMENT #: FI 1424944 DATE PAID:08/12/2019 FEE PAID: 545.00 RECEIPT #:56 -PID -4052302 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 5x10+1x9 long DF installed. No violations, system ok to cover. Contractor notified by email. Needs final inspection for mound system, gutters, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1428305 EID1982013