HomeMy WebLinkAboutWind Load CalcsNewSouth
WINDOW SOLUTIONS
2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC 1330822
Property Information
Building
Information
Owner: George & Juliana Knevett
Wind Zone:
170 MPH.
Address: 7602 Eden Rd
Exposure Category:
C
Fort Pierce, FL 34951
Minimum Building Dimension: 25 ft.
Mean Roof Height:
15 ft.
Device
Risk Category:
11
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 0th Edition (2017) Florida Building Code.
Page 1 of 1
Design
Pressure Calculations
Opening
P g
Location
Device
Device Device
Max Positive
Max Negative
g
Number
Zone
Width (in)
Height (in) Elevation (ft)
Pressure (psf)
Pressure (psf)
I
Int
104.50
60.75 7
34.2
-37.4
Int
72
61 7
35.1
-38.3
3
Int
72
61 7
35.1
-38.3
4
Int
35
36 7
37.8
41.0
5
Int
72
61 7
35.1
-38.3
6
Int
25
36 7
37.8
41.0
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 0th Edition (2017) Florida Building Code.
Page 1 of 1