Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE GRAND CARLTON IMPACT BuilderName: WYNNE BUILDING COPR. Street: l9'1 ";;\ �C'1 PermitOffice: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, ` PennitNumber. Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY DesignLocaton: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types.(1442.0 sgft.). Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int lnsul, Exterior R=4.1 1250.00ft2 b. Frame -Wood, Adjacent R=11.0' 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d•N/A R= ft2 5. Is this a worst case? Yes 10.Celling Types (1476.0 sgft,) Insulation Area a. UnderAttic(Vented). R=30.0 1446.00ft' 6. Conditioned floorarea above grade(ft2) 1446 b. Knee Wall(Vented) R=19.0 30.00 ft2 Conditioned floorareabelowgrade(ft2) 0 c. WA R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=1.04 101.25 ft' SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtumr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 It. Area Weighted Average SHGC: 0.284 14..Hot water systems 8. FloorTypes (1446.6 sgft.) Insulation Area a. Electric Cap:40gallons a. Slab -On -Grade Edgelnsulation R=0.0 1445650 ft2 b. Conservation features EF: 0.970 b. NIA R= ft- None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0,098 Total Proposed Modified Loads: 47.50 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this p Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: vx'�"r11/ Before construction is completed r� 4 DATE: 1-9-2D this building will be inspected for y compliance with Section 553:908 hereby certify that this building, as designed, is in compliance Florida Statutes. !„ with the Florida Energy Code. 'b 'WS " OWNER/A E BUILDING OFFICIAL: DATE: DATE: - Compliance.requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealedin accordance with R403.3.2.1. y� - Compliance requires an Air Barrier and Insulation Inspection Ctieckllst in ac c wi 02gr.1:T nOr Itt requires an envelope leakage test report with envelope leakage, no greater than 7.00 AC 50 1 REVIEWED FOR CODE COMPLIANCE 118/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) FyTqa&AM E COUNh'Mof5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Titte: WYNNE THE GRAND CARLT Bedrooms: 2 Address Type: StreetAddress Building Type: User ConditionedArea: 1446 Lot# OwnerName: WYNNE BUILDING CROP TotalStodes: 1 Block/Subdivlsloh: #of Units: 1 Worst Case: Yes PlatBook: .. BullderName: WYNNE BUILDING COPR. RotateAngle: 180 Street: Permit Office: ST. LUCIE COUNTY CrossVentllation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL, New/6dsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V Designi-ocation TMYSite 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 EntireHouse 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1636 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # FloarType Space Perimeter PedmeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edgelnsulation BEDROOM 52 ft 0 301 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulation WIC tft 0 63ft' ___ 0 1 0 3 Slab-On-GradeEdgeinsuiation M.BATH 8ft 0 56 ft- 0 1 0 4 Slab -On -Grade Edge Insulation KITCHEN 1ft 0 192 ft2 ____ 0 1 0 5 Slab -On -Grade Edgelnsulation BATH 5ft 0 451? ____ 0 1 0 .6 Slab-On-GtadeEdgelnsula0on BEDROOM 32.2ft 0 203.5 112 0 1 0 7:Slab-On-Grade Edge Insulation ENTRY 7ft 0 56 ft2 ____ 0 1 0. 1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2of5 FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 8SIab-On-GradeEdgelnsulation LAUNDRY 6ft 0 42 ft2 ---- 0 1 0 9SIab-On-GmdeEdgelnsulat1on GREAT/DINING 46ft 0 488ft' ---- 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 GableorShed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 UnderAtfic(Vented) WIC 30 Blown 63 ft' 0.1 Wood _ 3 UnderAttic(Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 UnderAttic(Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood _ 5 UnderAttic(Vented) BATH 30 Blown 45 ft2 0.1 Wood _ 6 UnderAtBc(Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood _ 7 UnderAtic(Vented) ENTRY 30 Blown 551t2 0.1 Wood 8 UnderAtfic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood _ 9 UnderAt9c(Vented) GREAT/DINING 30 Blown 488112 0.1 Wood 10 KneeWall(Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity, Wldlh Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block- Int Insul BEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block- Int Insul BEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 _3 NW=>SEExterior Concrete Block - Int Insul BEDROOM 4.1 14 0 8 0 112.0ft' 0 0 OA 0 _ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH 4.1 8 0 8 0 64.0 fN 0 0 OA 0 _ 5 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block- Int lnsuBEDR00M 2 4.1 16 0 8 0 128.0 f12 0 0' 0.4 0 _ 7 SE=>NW Exterior Concrete Block- Int lnsuBEDR00M 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 2 0 8 0 16.0 ft- 0 0 0.4 0 10 SE=>NW Exterior Concrete Block -Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 112 0 0 0.4 0 _12 SW=>NE Exterior Concrete Block -Int Insul LAUNDRY 4.1 6 0 8 0 48.0 f12 0 0 0.4 0 _13 NE=>SW Exterior Concrete Block-Int lnsuGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 OA 0 14 KV=>SE Exterior Concrete Block- IntlnsuGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/8/20204:18 PM-EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5 FORM R405-2017 ' INPUT SUMMARY. CHECKLIST REPORT WALLS Adjacent 15 N=>S Garage Frame -Wood Spars Cavity Width KITCHEN 11 24 8 Height Sheathing Framing Solar Below o . 192.0 ft2 0.23 0.4 0 DOORS # Omt DoorType Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown isthe entered orientation => chari ed to Worst Case. Wall # Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation ImShade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal _ 3 SE=>NW7 Metal _ 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Yes 1.04 0.29 Y Yes 1.04 0.29 Y Yes 1.04 0.29 Y Yes 1.04 0.29 Y Yes 1.11 0.27 Y 32.9 ft' 1 ft 0 in 1 ft 5 in 6.9 ft' 1 ft 0 in 1 ft 5 in 24.0 ft' 6ft0in 1ft5 in 37.5 ft2 1ft0in 1ft5in 40.0 ft' 8110ln 1ft5 in Drapes/blinds None None None Drapes/blinds Fxtedor5 None None None Extedor5 GARAGE # FloorArea CeilingArea ExposedWallPerimeter Avg.WaIIHelght ExposedWalllnsulation 1 315 ft' 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # Syslem Type Subtype Speed Efficiency Capacity .Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER:15 34.8 kBlu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120deg None 1/8/20204:18 PM EnergyGauge0 USA 6.0.02 (Rev. 1) - FlaRes2D17 FBC 6th Edition(2017) Compliant Software Page 4of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model* CollectorModel# Area Volume FEF None None ft= DUCTS —Supply-- --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft' Attic 65 ft= Defaultl-eakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable[[T��hermostat::[ C[ellling Fans: ]]Y Pleating HanIX] Feb H Mar ] E ] [ ] May [Xj �X [ ].Jun Jul IX] I I Aug �X] [ j ] r(�' ]Sep l l Nov 1 ac Venting [[ 11 Jan [[ 11 Feb X Mar' [X) Apr [ ] [ 1 Jun ]]1 Jul E [ ]PAug [ 1 Sep lxl Oc�l [X] Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78- 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78, 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heatin9(WD) 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.ft. 0 ft= 0 ft 0.3 BEDROOM Default(8lbs/sq.ft. ft= ft 0.3 WIC _ Defauit(8 lbs/sq.fL ft' ft 0.3 M: BATH Default(8lbs/sq.fL fN ft - 0.3 KITCHEN Default(81bs/sq.fL ft= ft 0.3 BATH Default(8lbs/sq.ft. ft. ft 0.3 BEDROOM 2 Default(8lbs/sq.ft, ft= ft 0.3 ENTRY Defaull(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY - Default 8lbs/s .fL ft=_ ft 0.3 . GREAT/DINING 1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) • FlaRss2017 FBC Bth Edition (2017) Compliant Software - Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. addition pe on of log wails shall b Street: PermitOfflce: ST.LUCIE.000NTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce V COMPONENT, AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A: continuous air barrier shall be Installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a. continuous air barrier. not be usedas a sealin material. g Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier In any dropped ceiling/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier., Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shallbesealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee wails shall be sealed. ,per inch minimum. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. .Rim joists Rim joists shall include the air barter. Rim joists shall be insulated. Floors. The air barrier shall beinstalled at any exposed edge of Floor framing cavity insulation shall be Installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom.to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor Insulation, Insulation a Class i vapor retarder with overlapping joints taped. 'shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by Insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures Installed In the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall 'Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls. adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. - be insulated. Electrical/phone box oi The air barrier shall, be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAO.register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the subAoor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed, in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a In IfI - ' ICC400. 1/8/2020 4:19 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th'Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location 8, insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERIGOP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER . e) Other 7. Windows, type and area a) U-facton(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c, a) Electric resistance EF 0.97 b) Gas fired; natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior, d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 9 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b)Single assembly 11b. c) Wholehousefan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit 0 Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: (� Date: rt1 Kt. Address of New Home \ A 4 City/FL Zip: FT. PIERCE. FL 1/8/2020 4:19:34 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1