HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE GRAND CARLTON IMPACT
BuilderName: WYNNE BUILDING COPR.
Street: l9'1 ";;\ �C'1
PermitOffice: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, `
PennitNumber.
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
DesignLocaton: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types.(1442.0 sgft.).
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int lnsul, Exterior
R=4.1 1250.00ft2
b. Frame -Wood, Adjacent
R=11.0' 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d•N/A
R= ft2
5. Is this a worst case? Yes
10.Celling Types (1476.0 sgft,)
Insulation Area
a. UnderAttic(Vented).
R=30.0 1446.00ft'
6. Conditioned floorarea above grade(ft2) 1446
b. Knee Wall(Vented)
R=19.0 30.00 ft2
Conditioned floorareabelowgrade(ft2) 0
c. WA
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor. Sgl, U=1.04 101.25 ft'
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtumr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. WA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 It.
Area Weighted Average SHGC: 0.284
14..Hot water systems
8. FloorTypes (1446.6 sgft.) Insulation Area
a. Electric
Cap:40gallons
a. Slab -On -Grade Edgelnsulation R=0.0 1445650 ft2
b. Conservation features
EF: 0.970
b. NIA R= ft-
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0,098 Total Proposed Modified Loads: 47.50
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
p
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: vx'�"r11/
Before construction is completed
r� 4
DATE: 1-9-2D
this building will be inspected for
y
compliance with Section 553:908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
!„
with the Florida Energy Code.
'b 'WS "
OWNER/A E
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance.requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealedin accordance with R403.3.2.1. y�
- Compliance requires an Air Barrier and Insulation Inspection Ctieckllst in ac c wi 02gr.1:T nOr Itt requires
an envelope leakage test report with envelope leakage, no greater than 7.00 AC 50 1
REVIEWED FOR
CODE COMPLIANCE
118/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) FyTqa&AM E COUNh'Mof5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Titte: WYNNE THE GRAND CARLT Bedrooms: 2
Address Type:
StreetAddress
Building Type: User ConditionedArea: 1446
Lot#
OwnerName: WYNNE BUILDING CROP TotalStodes: 1
Block/Subdivlsloh:
#of Units: 1 Worst Case: Yes
PlatBook:
.. BullderName: WYNNE BUILDING COPR. RotateAngle: 180
Street:
Permit Office: ST. LUCIE COUNTY CrossVentllation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/6dsting: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design
DailyTemp
V Designi-ocation TMYSite 97.5% 2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 EntireHouse 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1636 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# FloarType Space Perimeter PedmeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edgelnsulation BEDROOM 52 ft 0
301 ft2
____
0 1
0
2 Slab -On -Grade Edge Insulation WIC tft 0
63ft'
___
0 1
0
3 Slab-On-GradeEdgeinsuiation M.BATH 8ft 0
56 ft-
0 1
0
4 Slab -On -Grade Edge Insulation KITCHEN 1ft 0
192 ft2
____
0 1
0
5 Slab -On -Grade Edgelnsulation BATH 5ft 0
451?
____
0 1
0
.6 Slab-On-GtadeEdgelnsula0on BEDROOM 32.2ft 0
203.5 112
0 1
0
7:Slab-On-Grade Edge Insulation ENTRY 7ft 0
56 ft2
____
0 1
0.
1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2of5
FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood Carpet
8SIab-On-GradeEdgelnsulation LAUNDRY 6ft
0
42 ft2
----
0
1
0
9SIab-On-GmdeEdgelnsulat1on GREAT/DINING 46ft
0
488ft'
----
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 GableorShed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (I in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# CeilingType Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented) BEDROOM
30
Blown
301 ft'
0.1
Wood
2 UnderAtfic(Vented) WIC
30
Blown
63 ft'
0.1
Wood
_ 3 UnderAttic(Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 UnderAttic(Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
_ 5 UnderAttic(Vented) BATH
30
Blown
45 ft2
0.1
Wood
_ 6 UnderAtBc(Vented) BEDROOM
30
Blown
204 ft2
0.1
Wood
_ 7 UnderAtic(Vented) ENTRY
30
Blown
551t2
0.1
Wood
8 UnderAtfic(Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
_ 9 UnderAt9c(Vented) GREAT/DINING
30
Blown
488112
0.1
Wood
10 KneeWall(Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity, Wldlh
Height
Sheathing Framing Solar
Below
_ 1 NE=>SW Exterior Concrete Block- Int Insul BEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block- Int Insul BEDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.4
0
_3 NW=>SEExterior Concrete Block - Int Insul BEDROOM
4.1 14
0 8
0
112.0ft'
0
0
OA
0
_ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH
4.1 8
0 8
0
64.0 fN
0
0
OA
0
_ 5 NE=>SW Exterior Concrete Block-Int Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
6 NE=>SW Exterior Concrete Block- Int lnsuBEDR00M 2
4.1 16
0 8
0
128.0 f12
0
0'
0.4
0
_ 7 SE=>NW Exterior Concrete Block- Int lnsuBEDR00M 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 2
0 8
0
16.0 ft-
0
0
0.4
0
10 SE=>NW Exterior Concrete Block -Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block-Int Insul ENTRY
4.1 1
0 8
0
8.0 112
0
0
0.4
0
_12 SW=>NE Exterior Concrete Block -Int Insul LAUNDRY
4.1 6
0 8
0
48.0 f12
0
0
0.4
0
_13 NE=>SW Exterior Concrete Block-Int lnsuGREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
OA
0
14 KV=>SE Exterior Concrete Block- IntlnsuGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
1/8/20204:18 PM-EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5
FORM R405-2017 ' INPUT SUMMARY. CHECKLIST REPORT
WALLS
Adjacent
15 N=>S Garage Frame -Wood
Spars Cavity Width
KITCHEN 11 24 8
Height Sheathing Framing Solar Below
o .
192.0 ft2 0.23 0.4 0
DOORS
# Omt
DoorType
Space Storms
U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY None
.39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown isthe entered orientation => chari ed to Worst Case.
Wall
# Omt ID Frame
Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation
ImShade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
_ 3 SE=>NW7 Metal
_ 4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.11 0.27 Y
32.9 ft' 1 ft 0 in 1 ft 5 in
6.9 ft' 1 ft 0 in 1 ft 5 in
24.0 ft' 6ft0in 1ft5 in
37.5 ft2 1ft0in 1ft5in
40.0 ft' 8110ln 1ft5 in
Drapes/blinds
None
None
None
Drapes/blinds
Fxtedor5
None
None
None
Extedor5
GARAGE
# FloorArea
CeilingArea ExposedWallPerimeter
Avg.WaIIHelght ExposedWalllnsulation
1 315 ft'
315ft2 24ft
8ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000356 1349.6 74.09 139.34 .1233
7
HEATING SYSTEM
# Syslem Type
Subtype Speed Efficiency
Capacity
.Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 CentralUnit/
Split Single SEER:15
34.8 kBlu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
System Type
SubType
Location EF Cap
Use SetPnt
Conservation
1 Electric
None
Garage 0.97 40 gal 60.9 gal 120deg
None
1/8/20204:18 PM EnergyGauge0 USA 6.0.02 (Rev. 1) - FlaRes2D17 FBC 6th Edition(2017) Compliant Software Page 4of5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
System
Model* CollectorModel#
Area Volume
FEF
None None
ft=
DUCTS
—Supply--
--Return—
Air
CFM 25 CFM25
HVAC#
V # Location R-Value Area
Location
Area
LeakageType
Handler
TOT OUT ON RLF
Heat Cool
1 Attic
6 175 ft'
Attic
65 ft=
Defaultl-eakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programable[[T��hermostat::[
C[ellling Fans:
]]Y
Pleating HanIX] Feb
H Mar
]
E ]
[
] May
[Xj �X
[ ].Jun Jul
IX]
I I Aug
�X]
[
j ] r(�'
]Sep l l
Nov
1 ac
Venting [[ 11 Jan [[ 11 Feb
X Mar'
[X) Apr
[
]
[ 1 Jun ]]1 Jul
E
[ ]PAug
[
1 Sep lxl Oc�l [X]
Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5 6
7
8
9 10
11
12
Cooling(WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78-
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78, 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heatin9(WD)
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating(WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness FumitureFraction
Space
Default(8lbs/sq.ft.
0 ft=
0 ft
0.3
BEDROOM
Default(8lbs/sq.ft.
ft=
ft
0.3
WIC
_ Defauit(8 lbs/sq.fL
ft'
ft
0.3
M: BATH
Default(8lbs/sq.fL
fN
ft -
0.3
KITCHEN
Default(81bs/sq.fL
ft=
ft
0.3
BATH
Default(8lbs/sq.ft.
ft.
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft,
ft=
ft
0.3
ENTRY
Defaull(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY -
Default 8lbs/s .fL
ft=_
ft
0.3 .
GREAT/DINING
1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) • FlaRss2017 FBC Bth Edition (2017) Compliant Software - Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
addition pe on of log wails shall b
Street: PermitOfflce: ST.LUCIE.000NTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
V
COMPONENT,
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A: continuous air barrier shall be Installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a. continuous air barrier.
not be usedas a sealin material.
g
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier In any dropped ceiling/soffit shall be aligned with
The Insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.,
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shallbesealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee wails shall be sealed.
,per inch minimum.
Exterior thermal envelope Insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
.Rim joists
Rim joists shall include the air barter.
Rim joists shall be insulated.
Floors.
The air barrier shall beinstalled at any exposed edge of
Floor framing cavity insulation shall be Installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom.to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor Insulation, Insulation
a Class i vapor retarder with overlapping joints taped.
'shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by Insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures Installed In the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
'Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls. adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs. -
be insulated.
Electrical/phone box oi
The air barrier shall, be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAO.register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the subAoor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed, in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a In IfI
-
'
ICC400.
1/8/2020 4:19 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th'Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location 8, insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEERIGOP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER .
e) Other
7. Windows, type and area
a) U-facton(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c,
a) Electric resistance EF
0.97
b) Gas fired; natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior,
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
9 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b)Single assembly
11b.
c) Wholehousefan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: (� Date:
rt1 Kt.
Address of New Home \
A 4 City/FL Zip: FT. PIERCE. FL
1/8/2020 4:19:34 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1