HomeMy WebLinkAboutProduct Approval (2) 5/12/2020 Florida Building Code Online
Business & Professional Regulation
u.acrsHome I 1pg M I User Registraapn I HOTppla I SubmitSurcharge I Stab&Fads! Pubil.Upns I Cp Ud Us aQS Sbe Map I links s—ch
d � r Product Approval
use¢:Pamlc user
aim
PmEud --1 1-,>PrpOud pr Rgpiirarlon Search>egpicatlpn LISL>Appriotipn Derail
FL 3 FL12328-118
_ Application Type Revision
Code Version - 2017
Application Status Approved
Comments
Archived
- Product Manufacturer TAMKO Building Products LLC
Address/Phone/Email PO Box 97
Galena,KS 66739
(417)624-6644 Ext 2305
kerrLeden@tamko.com
Authorized Signature Kerri Eden
karrLeden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
_ (417)624-6644 Ext 2305
kerrLeden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
0 Evaluatlon Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Report Zachary R.Priest
Florida License PE-74021
Quality As Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By Locke Bowden P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL12328 R8 COI TBP34001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf
Referenced Standard and Year(of Standard) Standard - Year
ASTM D1970 2015
ASTM D226 2009
ASTM 04869 2016
ASTM D6380 2003 .
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated - 10/19/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
12328.1- ASTM Slate Surfaced Roll Roofing Roll mofing surfaced with mineral granules
Limits of Use Installation Instructions
Approved for use in HVHZ:YesFI t 2328 RB iI TBP34001.4 2017 FBC Eva]Report TAMKO Underlayments final.p�(
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. Fl created
RB de endent h 4 2017 FBC Eval Reoort TAMKO Underlayments final.psl[
Created by Independent Third Party:Yes
12328.2 ASiM Tile Untlerlayment Coated organic underlayment
Limits of Use - Installation Instructions
Approved for use in HVHZ:Yes FU2328 R8 II TBPT4001 4 2017 FBC Eval Reoort TAMKO Underlayments final.pr�f
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A EvaluationReports
I t
Other:See evaluation report for limits of use. F 2328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO Underlayments nnal.29
Created by Independent Third Party:Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=vvGEVXQwtDgtF2Aezuarjg0lAram DGm5ebt5wRW28J8d8c61CFKFGNQ%3d%3d 1/2
5/12/2020 Florida Building Code Online
12328.3 Master Smooth Asphalt saturated organic underlayment.
Limits-of
Use Installation Instructions
Approved for use in HVHZ:No FI t 7378 RB II TBP14001 4 2017 FBC Eval Reoort TAMKO Underlayments final.p�
Approved for use outside HVHZ:Yes - Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A - Evaluation Reports
Other:See evaluation report for limits of use. EI+737R RB AE TBP14001 4 2017 FBC Eval Report TAMKO Underlayments Bnal.P-df
Created by Independent Third Party:Yes
12328.4 Moisture Guard A self-adhering modified bitumen underlayment.
Limits of Use Installation Ins
Approved for use in HVHZ:Yes F 12328 R8 11=1 4 2017 FBC Eval Report TAMKO Underlayments final.pdf
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. FI+7378 RR AF TBP14001.4 2017 FBC Eval Report TAMKO Underlayments Final.pdf
Created by Independent Third Party:Yes
12328.5 No.15 ASTM Asphalt saturated organic felt
Limits of Use Installation Ins .
Approved for use in HVHZ:Yes FI+7328 RS j=,.4 2017 FBC EVal Report TAMKO Underlayments final.k(
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. FL12328 RS AE TBP14001 4 2017 FBC Eval Report TAMKO Underlayments flnal.pf[
Created by Independent Third Party:Yes
12328.6 No.15 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL72328 R8 II
TBP34001 4 2017 FBC Eval Report TAMKO Underlavmen[s Flnal.p�f
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Parry:Yes
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. FL12328 RB AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdF
Created by Independent Third Party:Yes
12328.7 No.30 A— Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 IT TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. F1,12328 R8 AE TBP14001.4 2017 FBC F.val ReportTAMKO Underlayments flnal.pdf
Created by Independent Third Party:Yes
12328.8 No.30 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 RB II TBP74001.4 2017 FBC Eval Report TAMKO UnAerlaymen[s FlnaLOf -
Approved for use outside HVHZ:Yes Verified By:Zachary R.Pries[74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other.See evaluation report for limits of use. FL12328 RB AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.2df
Created by Independent Third Party:Yes
12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 iI TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.odf
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest PE-74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. FL12328 R8 AE TBP14001.4 2017 F8C Eval Report TAMKO Underlayments Flnal.Pdf
Created by Independent Third Party:Yes
12328.10 TW Metal and Tie Underlayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 lI TBP34001.4 2017 FBC Eval Report TAMKO Underlayments Final.pdf -
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A _ Evaluation Reports
Other:See evaluation report for limits of use. FL12328 RB AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.PAf
Created by Independent Third Party:Yes
12328.11 TW Underlayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14007.4 2017 FBC Eval Reoort TAMKO Underlayments Final.pd
Approved for use outside HVHZ:Yes Verified By:Zachary R.Priest 74021
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. FL12328 R8 AE TBP140D1.4 2017 FBC Eval Report TAMKO.Underlayments final.pd
Created by Independent Third Party:Yes
earx naxe
Coated Us::3601 Blair Ston.Road.Tallahassee FL 32399 Phone:850-487-IB24
The Stele 91 Fladtla Is an AA/EEO employer.Cop)'d9ht 200J-2013 State of Fbrlda.::PELStatement::AcrnsslW11W Stat—Int::Refund statement
Under Rodda law,email addresses are public recalls.Iryou do notwantyour e-mail address ret amd In response w a pubbcrecords request,da not send eleRnnlc mall to this entity.Instead,cantatt the amps by phone er by tradltlonal mall I/you have ,
any questions,eusA Iforsomclalacemm5 u—ton the Umn[am eHowav rSemJaill eddRorie.
resses atatute.. ffii m public remrd.If yopiser 1,u do notO12,wishlice—asi licensed under to supply a personal addpiew,tpl ass,F.S.must prowide me ro,lda the Im airmentw N a, mail address wmail
hich mn be mzaaaa.liable to no malls p.bll.'i dad
may determine if you are a licensee under chapter 455,ES,please dickebt@• Impairment pu
Product Approval A.pb
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5ebt5wRW28J8d8c6lCFKFGNQ%3d%3d 2/2
Certificate of Authorization No. 29824
CREEK 17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
htto://www.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO®ASTM Slate ASTM D 6380, Class M,Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO®ASTM Tile ASTM D 6380, Class M,Type.11 underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both.sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO®No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.15 UL ASTM D 226, Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.30 UL ASTM D 226, Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®TW Metal and Self-adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKO@ TAM-FELT Alternate to ASTM D 226,Type I and Type II underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the .
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1i8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO@ TW Metal and Tile Underlayment and TAMK00 TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO@ Moisture Guard@ shall be 35°F.
The minimum roof slopeshall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments.shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMK00 TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof -. ',.Mineral' Wood
, Asphalt' .Panels and; Surlaced,Roll Shingles and Slate, Clay and
Underly meet: . Shin les. ,..�Shiin les ' Roofin Shakes 'Shingles :Concrete Tile"
TAMKOO ASTM Slate Y1 N N N N Y
Surfaced Roll Roofing
TAMKO@ ASTM Tile N N N N N Y
Underlayment
TAMKO@ Master Smooth Y' N N N N N
TAMKOO Moisture Guard@ Y N N N N N
TAMKO@ No.15 ASTM
Asphalt Saturated Organic Y Y Y Y2 N N
Felt.
TAMKOO No.15 UL Asphalt Y Y Y YZ Y N
Saturated Organic Felt
TAMKOO No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKO@ No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKOO TW Metal and Tile Y Y N N N Y
Underlayment
TAMKO@ TW Underlayment Y Y N N N N
TAMKOO TAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001.4" FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
CREAK TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed.in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-21.4-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01. ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D'1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
� � TAMKO BUILDING PRODCUTS;INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
2017.10.19
. No 74021 12:15:58
�., _• . r
z .. ...a u.,....�....._
sU �_ —04'00'
STATE O F
Zachary R. Priest, P.E.
C?N_�`� Florida Registration No. 74021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. .
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.